• 제목/요약/키워드: Facility Capacity

검색결과 627건 처리시간 0.033초

관외 빙착형 빙축열시스템의 운전방식에 따른 최소용량 비교 (Comparative analysis of the minimum capacity of an ice-on-coil thermal storage system for various operation strategies)

  • 이대영;정성훈;강병하
    • 설비공학논문집
    • /
    • 제11권3호
    • /
    • pp.401-413
    • /
    • 1999
  • An ice storage cooling facility with cooling capacity of 150㎾ has been constructed for the purpose of developing optimal design and control strategy for an ice storage system. As the first step to this purpose, a computer program has been developed to simulate the operation of the ice storage system and examined precisely by comparing the results with those measured from the test facility. With the simulation program verified from the comparison, a design procedure has been developed to determine the minimum capacity required for each operation strategy available commercially. It is shown that the minimum sizes of the chiller and the storage tank are strongly dependent on the control strategy, i.e., chiller priority or storage priority, but less affected by the arrangement method, i.e., chiller upstream or chiller downstream.

  • PDF

생활폐기물 소각시설의 운영 실태 분석을 통한 에너지회수 효율 개선방안 검토 (A Study on Improvement Measures of Energy Recovery Efficiency through Analysis of Operational Status of Municipal Solid Waste Incineration Facilities)

  • 박상진;배재근
    • 한국폐기물자원순환학회지
    • /
    • 제35권8호
    • /
    • pp.762-769
    • /
    • 2018
  • This study was carried out to examine the improvement plan by analyzing the characteristics of imported wastes, operation rate, and benefits of energy recovery for incineration facilities with a treatment capacity greater than 50 ton/day. The incineration facility capacity increased by 3,280 tons over 15 years, and the actual incineration rate increased to 2,783 ton/day. The operation rate dropped to 76% in 2010 and then rose again to 81% in 2016. The actual calorific value compared to the design calorific value increased by 33.8% from 94.6% in 2002 to 128.4% in 2016. The recovery efficiency decreased by 29% over 16 years from 110.7% to 81.7% in 2002. Recovery and sales of thermal energy from the incinerator (capacity 200 ton/day) dominated the operation cost, and operating income was generated by energy sales (such as power generation and steam). The treatment capacity increased by 11% to 18% after the recalculation of the incineration capacity and has remained consistently above 90% in most facilities to date. In order to solve the problem of high calorific value waste, wastewater, leachate, and clean water should be mixed and incinerated, and heat recovery should be performed through a water-cooled grate and water cooling wall installation. Twenty-five of the 38 incineration facilities (about 70%) are due for a major repair. After the main repair of the facility, the operation rate is expected to increase and the operating cost is expected to decline due to energy recovery. Inspection and repair should be carried out in a timely manner to increase incineration and heat energy recovery efficiencies.

Seismic capacity evaluation of fire-damaged cabinet facility in a nuclear power plant

  • Nahar, Tahmina Tasnim;Rahman, Md Motiur;Kim, Dookie
    • Nuclear Engineering and Technology
    • /
    • 제53권4호
    • /
    • pp.1331-1344
    • /
    • 2021
  • This study is to evaluate the seismic capacity of the fire-damaged cabinet facility in a nuclear power plant (NPP). A prototype of an electrical cabinet is modeled using OpenSees for the numerical simulation. To capture the nonlinear behavior of the cabinet, the constitutive law of the material model under the fire environment is considered. The experimental record from the impact hammer test is extracted trough the frequency-domain decomposition (FDD) method, which is used to verify the effectiveness of the numerical model through modal assurance criteria (MAC). Assuming different temperatures, the nonlinear time history analysis is conducted using a set of fifty earthquakes and the seismic outputs are investigated by the fragility analysis. To get a threshold of intensity measure, the Monte Carlo Simulation (MCS) is adopted for uncertainty reduction purposes. Finally, a capacity estimation model has been proposed through the investigation, which will be helpful for the engineer or NPP operator to evaluate the fire-damaged cabinet strength under seismic excitation. This capacity model is presented in terms of the High Confidence of Low Probability of Failure (HCLPF) point. The results are validated by the proper judgment and can be used to analyze the influences of fire on the electrical cabinet.

수산물 냉동냉장설비의 현황 및 분석 (Present Situation and Analysis of Cold Storage Facilities for Fisheries Products)

  • 손창효;오후규
    • 설비공학논문집
    • /
    • 제23권6호
    • /
    • pp.406-412
    • /
    • 2011
  • This paper describes the analysis on freeze and refrigeration capacity of cold storage facilities for fisheries products during the last 15 years. And based on the analysis results, we prospect the number and scale of cold storage facilities in the near future. The main analysis results are summarized by the followings; Under the present conditions, the number and scale of our facilities is 879 and 3,586,824 ton, respectively. In comparison of the present and last 15 years ago, the business number increases about 22%, the accommodation capacity increases approximately 80%. In the reported update reference with the related data during the last 15 years, the capacity of cold storage facilities in 2011 expects to reach up to 4,600,000 ton. The newlyestablished facility in 2011 has the function of a multi-purpose distribution center as well as the existing cold storage, but this facilities converges in the capital area. Therefore, in this paper, we provided the basic reference data for the present situation and prediction of our cold storage facilities. But it is necessary to investigate and analyse widely our cold storage facilities for fisheries products in the near future.

도시 물순환 건전화를 위한 빗물관리 계획요소 평가 (Assessment of Criteria for selecting Rainwater Management Strategies)

  • 이태구;한영해
    • KIEAE Journal
    • /
    • 제10권4호
    • /
    • pp.9-17
    • /
    • 2010
  • The purpose of this study is to draw out objective bases for selecting various applicable facilities in case of the establishment of rainwater management strategies. To do so, sixteen facilities were selected from decentralized rainwater management systems that induce rainwater infiltration and detention as well as centralized end-of-pipe type infiltration and detention facilities in local areas. With these facilities, it attempted to evaluate them in terms of sustainability, pollutant elimination, flood control capacity and costs and subsequently analyzed correlations between each characteristic. The outcomes of the analysis were as follows: First was the analysis of characteristics between decentralized rainwater management systems and end-of-pipe rainwater management systems. From the decentralized rainwater management systems, the mulden-rigolen system and grass swale at street level had the highest in the total of the four items while the totals of the underground detention tank and temporary detention site were highest in end-of-pipe rainwater management systems. After analyzing the correlation between different types of facilities and each variable, it can be said that decentralized rainwater management systems have a higher correlation than end-of-pipe rainwater management systems in terms of sustainability whereas the latter are better in flood control capacity than the former. Second, the analysis of correlation in variables of each facility is as follows: first, there is a negative correlation between sustainability value and flood control capacity value; and there is a positive correlation between flood control capability and pollutants elimination. In addition, it revealed that the higher the flood control and pollutant elimination capability the higher the facility costs. Based on these assessments, it is possible to use them as objective selection criteria for facility application in case of site development project or complex plan.

합리적인 지역 에너지 시스템(Community Energy System)의 구성과 경제성 검토 (An Optimal Configuration and Feasibility Study for Community Energy System (CES))

  • 기우봉;박용업;김황호;장성일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.123-125
    • /
    • 2004
  • This paper describes an optimal configuration of Community Energy System (CES) for the multi-energy consumers and analyzes economical feasibility for such system. The most of previous feasibility studies for Co-Generation plants of CES in Korea have shown negative results due to the abnormally low price of power rate in Korea. However, in order to overcome this situation a new approach was examined in this Paper. The efforts of this approach the selection of the low price but reliable facility and maximizing the capacity factor of the facility. MGT was selected in view of low price and good reliability. In order to maximize the capacity factor the system capacity should be quite lower than the actual required Electrical and Heat load of the subject entity. In this report 100 kW Co-Generation facility was selected in view of conservative analysis. The results of the analysis showed that pay back period may vary from 4 to 5 yens according to the application of LNG rates whether it is to-generation rate or the normal business rate. With the analysis in this paper we confirmed that CES is feasible even in Korea if we do not insist to select the capacity of CES to cover all the energy required but select a smaller size of CES compared to the actual requirement, which can allow full load operation of the system continuously.

  • PDF

영유아 보육시설의 조리실 시설 현황 조사 및 조리실 시설 설계 기준안 개발 (Assessment of the Child Care Centers' Foodservice Facility and Development of the Kitchen Facility Model based on the General Sanitation Standards and Guidelines)

  • 박영주;곽동경;강영재;정홍관
    • 대한영양사협회학술지
    • /
    • 제9권3호
    • /
    • pp.219-232
    • /
    • 2003
  • The purposes of this study were to assess the child care centers' foodservice facility, and to develop the kitchen facility model based on the general sanitation standards and guidelines in order to provide basic information for a plan review to build or renovate child care centers' foodservice facility. The scopes of the study include : 1) field assessment of the foodservice management practices and facilities in 8 public child care centers, and 2 private child care centers which they are subsidized from the government as public child care centers, 2) development of child care centers' kitchen facility model based on the General Sanitation Standards and Guidelines. The results of this study can be summarized as follows : 1. Field Assessment of the Child Care Centers' Foodservice Facility Average number of children in child care centers was 78.0$\pm$24.20, the average space of kitchen was 15.13$\pm$4.25($m^2$). Especially, the average space of kitchen was 18.49$\pm$4.35($m^2$) with enrollment capacity of 90~120 children in child care centers. The inventory level of most foods was relatively low except rice and kimchi. Kitchen facilities and equipments were similar to those of home kitchen and did not meet the standards of institutional practice. Therefore, the director in child care centers should recognize the importance of the sanitation management and pay more attention to the renovation of foodservice facilities as well as sanitation management practices. 2. Development of the Kitchen Facility Model based on the General Sanitation Standards and Guidelines The kitchen facility plan model with enrollment capacity of 100 children was developed based on the results of field assessment and literature review. Suggested kitchen space was 34.16$m^2$(6,100mm×5,600mm). This space was bigger than the results of field survey or precedent study, considered appropriate to implement the general sanitation standards. The main feature of the developed kitchen facility plan and model was product flow in one direction from the arrival of the raw material to the finished product in order to prevent cross contamination and to improve working efficiency.

  • PDF

공항 수용량의 지연시간 산출방식 비교 연구 (A Comparative Study on Delay Calculation Method of Airport Capacity)

  • 이효주;김도현
    • 한국항공운항학회지
    • /
    • 제28권2호
    • /
    • pp.47-52
    • /
    • 2020
  • Air transport demand is on a sharp rise due to growth in the aviation market. To prepare for this rapidly growing demand for aviation, airport operators are interested in the processing airport capacity. Airport throughput is determined to be the smallest of the facility capacities that make up the airport, but it is customary to determine the cost and time consuming runway capacity as airport capacity. Previous studies have shown that while recent studies have been conducted on airport capacity, there is little research on the criteria for determining capacity. In this study, we would like to determine the extent to which airport capacity is affected by the airport's operating hours and the resulting delays.

V2G를 이용한 전력계통 서비스 (Grid service using Vehicle-to-Grid)

  • 이현구;손홍관;하태현;배정효;김대경;이성준;김성철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.141-142
    • /
    • 2011
  • The increase in oil prices and the rising environmental concerns are boost the electric vehicle supply. Vehicle manufactures understand this trend quite well and plan to increase the production of electric vehicle(EV) such as Nissan LEAF and GM VOLT etc.. The growth of intermittent renewable energy sources such as solar and wind power requires utilities to find additional grid coupled energy storage and regulation capacity. EVs have a battery pack and a charger. The charger can be able to deliver power back to the grid from the vehicle's battery as well as charge the battery. The concept of deploying EVs to stabilize the electric power grid is generally referred to as Vehicle-to-Grid(V2G). We present the grid service using V2G.

  • PDF

도시 물 순환 개선을 위한 생태저류지의 최적설계용량 결정 (Determination of Optimum Design Capacity of Bio-retention for Improvement of Urban Water Cycle)

  • 이옥정;최정현;이정훈;김상단
    • Korean Chemical Engineering Research
    • /
    • 제55권6호
    • /
    • pp.745-753
    • /
    • 2017
  • 본 연구에서는 도시 개발에 따라 왜곡된 도시 물 순환을 LID 시설을 통하여 자연적인 물 순환으로 되돌리고자 하는 설계전략이 제안된다. 이는 도시 개발 전과 후의 유황곡선이 동일하게 유지되는 최적의 LID 시설 설계용량을 결정함으로서 구현된다. 부산 녹산 국가산업단지의 일부지역이 연구대상지역으로 선정되었으며, 다양한 토지이용시나리오 및 LID 시설 설계용량에 대한 강우유출수 모의를 위하여 EPA SWMM이 구축되었다. 연구대상지역이 개발이전에 임야지역 또는 농경지역이라 가정하였을 경우, 도시 개발 이후에도 유황곡선이 도시 개발 전과 동일하게 유지되기 위해서는 불투수지역의 7.3% 또는 5.5%를 생태저류지의 면적으로 할당해야 함을 확인하였다. 또한 지역별 강우특성에 따른 생태저류지 설계용량의 민감도 분석을 수행한 결과, 농경지역의 개발 시에는 불투수지역의 3.8~5.5% 정도의 설계용량이 필요한 것으로 나타남에 따라 지역별 강우특성에 따라 생태저류지의 최적용량이 유의하게 달라질 수 있음을 살펴볼 수 있었다. 반면에, 생태저류지 각 층별 깊이의 변화에 따른 설계용량의 민감도 및 처리대상구역의 크기에 따른 민감도를 분석한 결과, 생태저류지의 설계 제원 및 처리대상구역의 크기에 따른 최적설계용량의 민감도는 크지 않은 것으로 나타났다.