• Title/Summary/Keyword: Facility Capacity

Search Result 633, Processing Time 0.036 seconds

A Study on the Optimization of Power Supply Equipment for Plate Mill Plant in Steelworks (제철소 후판공장 전원공급설비의 용량 최적화에 관한 연구)

  • Ko, Hyun-Ok;Park, Ji-Ho;Kim, Dong-Wan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.9
    • /
    • pp.1300-1305
    • /
    • 2014
  • In this paper, we suggest an optimization method which can save about 5[%] of the cost though the optimizing of configuration and capacity for the facility. To achieve this goal, we compared the design data of the power, motor and drive system with the actual operation data of the plate mill plant in K-Steelworks. Therefore we measured the actual loading data by facilities considering the operating conditions of the plate mill plant in K-Steelworks, after that analyzed these data. In addition, we review the optimal capacity for transformer, switchgear and drive, and also reconfigured the electrical room and power single line diagram through the validation of motor data by equipment and the confirmation of process data considering the load characteristics. Consequently, the optimization method of capacity for the facilities shall have effectiveness in building new plate mill plant to further reduce costs at future.

Methods of WAP Gateway Capacity Dimensioning and Traffic Forecasting (WAP 게이트웨이 용량 산출과 트래픽 예측 기법)

  • Park, Chul-Geun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.4B
    • /
    • pp.576-583
    • /
    • 2010
  • Wireless Internet is the network which provides wireless access in order to serve the Internet connections and data communication through the mobile handsets. To get efficient wireless access to the Internet, we need the WAP (Wireless Application Protocol) gateway that performs protocol translation and contents conversion between two different networks. We need the capacity dimensioning of the WAP gateway system in order to provide the wireless Internet service stably and cost-effectively. We also need the traffic engineering methods including traffic modelling and forecasting for the economical facility investment. The existing method of WAP gateway capacity dimensioning was intuitive and qualitative. But in this paper, we deal with the capacity dimensioning analytically and quantitatively on the basis of WAP traffic description parameters and traffic forecasting method.

An Experimental Investigation of Thermodynamic Performance of R-22 Alternative Blends

  • Kim, Chang-Nyeon;Park, Young-Moo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.6
    • /
    • pp.36-44
    • /
    • 1998
  • R-410a and R-407c which have the best potential among R-22 alternatives were tested as drop-in refrigerants against a set of R-22 baseline tests. The performance evaluations were carried out in a psychometric calorimeter test facility using the residential spilt type air conditioner under the ARI rating conditions. Except the lubricant and hand-operated expansion valve, the other parts of the air conditioner were the same with the commercial system. Performance characteristics were measured; compressor power, capacity, VCR, mass flow rate and COP. The tests showed that R-407c can be directly charged into the current refrigeration system because its vapor pressure and other thermochemical properties are similar to those of R-22. However, it is required to change the volume flow rate of compressor in order to achieve the volumetric capacity of R-22. This results from its relatively small VCR and capacity. Meanwhile, R-410a has vapor pressure values too high to be substituted for the current system and this resulted relatively low COP of R-410a compared to that of R-22.

  • PDF

An experimental investigation of thermodynamic performance of R-22 alternative blends (R-22 대체용 혼합냉매의 열역학적 성능에 대한 실험연구)

  • Hwang, E.P.;Kim, C.N.;Park, Y.M.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.1
    • /
    • pp.82-91
    • /
    • 1997
  • R-410a and R-407c witch have the best potential among the substances being considered as R-22 alternatives were tested as "drop in" refrigerants against a set R-22 baseline tests for comparison. The performance evaluations were carried out in a psychrometric calorimeter test facility using the residential split-type air conditioner under the ARI rating conditions. Other than the use of different lubricant and a hand-operated expansion valve, one of the commercial systems was selected for the experiment. Performance characteristics were measured; compressor power, capacity, VCR, mass flow rate and COP. The tests showed that R-407c can be directly applied to the existing refrigeration system because of its similar vapor pressure and other thermopysical properties with those of R-22. However, it required change to the volume flow rate of compressor in order to achieve the similar performance with R-22 because of its relatively small VCR and capacity. Meanwhile, R-410a has too high a vapor pressure to be applied to the existing system and this feature results in relatively low COP of the system compared to that of R-22. But this could be improved by changing compressor design considering R-410a's relatively high VCR and capacity compared to those of R-22.

  • PDF

An Investigation Study on the Coefficient of Occupants Density for Performance Evacuation Capacity Computation in Buildings (성능적 피난용량산정을 위한 대형할인마트의 재실자밀도 계수 조사연구)

  • Seo, Dong-Goo;Shin, Yi-Chul;Lee, Jae-Young;Kwon, Young-Jin
    • Fire Science and Engineering
    • /
    • v.23 no.5
    • /
    • pp.1-8
    • /
    • 2009
  • As the rapid and various changing of social aspects, the structures are getting bigger, higher and more complex. The importance of evacuation is on the rise as increased using frequency of multiplex sale facility and it's a high population density. According to the result of a survey with 4 domestic wholesales mart's population density, the maximum was 0.30, 0.46, 0.42, 0.38 人/$m^2$ in and 0.46 人/$m^2$). Considering evacuation dangerousness, the maximum value will be suitable for computation of evacuation capacity and this will be submitted as a basic DATA for computation of evacuation capacity.

Performance of Hygiene Management according to Capacity and Food Cost of Foodservice in Kindergartens (시설 규모 및 급식비에 따른 유치원 급식소 위생 관리 수행도)

  • Kim, Ok-Sun
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.24 no.5
    • /
    • pp.680-690
    • /
    • 2014
  • This study investigated the performance of hygiene management according to the capacity and food cost of foodservice in kindergartens as a measure of kindergartens foodservice hygiene management. Dietitians from the education office visited 50 kindergartens under the control of Dongbu District Office of Education during January, 2011. Kindergartens were 11 public and 39 private institutions. Over half of kindergartens (n=27) provided foodservice to 50~99 children. About 21 kindergartens had a foodservice cost per student per day of 2,000 won. Regarding personal hygiene, 'whether to wear an accessory or have a manicure' showed the best performance. 'Whether to have their health examined once every 6 months or keep their health records in 2 years' was rarely performed. For food materials, 'whether to buy food appropriate for the quality control standard of food materials' showed the highest performance. The highest performances for storage management of food materials and handling of food was 'whether to store goods within butlery at intervals more than 30 cm from the ground' and 'whether to heat and cook food more than $74^{\circ}C$', respectively. The highest performance for distribution of food and management of facilities was 'the hygienic management of cooking tools and facilities' and 'the proper installation of air-conditioning, heating and ventilation facilities', respectively. The results of this study show that capacity and food cost had the strongest effects on performance of personal hygiene. Especially, smaller facility size could increase performance of foodservice management.

The Study on Assessment of Protective Capacity of the Reinforced Concrete Box-type Artillery Positions (철근콘크리트조 박스형 포상의 방호성능 평가)

  • Baek, Jonghyuk;Kim, Suk Bong;Son, Kiyoung;Park, Young Jun
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.17 no.2
    • /
    • pp.275-281
    • /
    • 2014
  • Although self-propelled artilleries are mobile equipment, they need their own covered-positions for survival against preemptive strikes. The most important military requirement is enough protective capacity against blast pressure caused by explosion. This paper aims to assess the protective capacity of the newly-placed concrete box-type artillery positions using accurate structural geometric models as well as soil-structure interaction analysis. The commercial program is used to model the structural geometry of the positions. In order to describe the correct wave propagation in the backfill along with soil-structure interaction, used parameters in shock equation of state are selected based on the related studies as well as theories and then their final results are verified with the ones calculated with empirical equations in the US Unified Facility Criteria. In sum, it could be concluded that the protective capacity of the newly-built positions satisfies the protective structural requirement.

Performance Evaluation of R-22 Alternative Refrigerants with Hydrofluorocarbon and Hydrocarbon (HFC 및 탄화수소를 포함한 R-22 대체냉매의 성능평가)

  • 김창년;박영무;이병권;임종성
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.3
    • /
    • pp.315-324
    • /
    • 2000
  • R-410A, R-407C, and four refrigerant mixtures composed of R-32, R-l34a, R-l43a, R-l52a, R-600(butane), and R-600a(isobutane) were tested in an attempt to replace R-22 used in most of the residential air conditioners. The performance evaluation was carried out in a psychrometric calorimeter test facility using a residential spilt type air conditioner under the KS rating conditions. Except for the lubricant and hand-operated expansion valve, the other parts of the air conditioner were the same with the commercial system. Performance characteristics were measured; COP, capacity, compressor power, and VCR. R-410A was shown to have 5.5% higher COP and 3.5% lower capacity than R-22. R-32/134a/600a (42.8/ 46.0/11.2 wt%) mixture have the best performance among the four refrigerant mixtures composed of hydrofluorocarbon and hydrocarbon. This inixture have 3.0% lower COP and 1.6% lower capacity than R-22.

  • PDF

ANALYSIS OF THE TRANSPORTATION LOGISTICS FOR SPENT NUCLEAR FUEL IN KOREA

  • Lee, Hyo-Jik;Ko, Won-Il;Seo, Ki-Seok
    • Nuclear Engineering and Technology
    • /
    • v.42 no.5
    • /
    • pp.582-589
    • /
    • 2010
  • As a part of the back-end fuel cycle, transportation of spent nuclear fuel (SNF) from nuclear power plants (NPPs) to a fuel storage facility is very important in establishing a nuclear fuel cycle. In Korea, the accumulated amount of SNF in the NPP pools is troublesome since the temporary storage facilities at these NPP pools are expected to be full of SNF within ten years. Therefore, Korea cannot help but plan for the construction of an interim storage facility to solve this problem in the near future. Especially, a decision on several factors, such as where the interim storage facility should be located, how many casks a transport ship can carry at a time and how many casks are initially required, affect the configuration of the transportation system. In order to analyze the various possible candidate scenarios, we assumed four cases for the interim storage facility location, three cases for the load capacity that a transport ship can carry and two cases for the total amount of casks used for transportation. First, this study considered the currently accumulated amount of SNF in Korea, and the amount of SNF generated from NPPs until all NPPs are shut down. Then, how much SNF per year must be transported from the NPPs to an interim storage facility was calculated during an assumed transportation period. Second, 24 candidate transportation scenarios were constructed by a combination of the decision factors. To construct viable yearly transportation schedules for the selected 24 scenarios, we created a spreadsheet program named TranScenario, which was developed by using MS EXCEL. TranScenario can help schedulers input shipping routes and allocate transportation casks. Also, TranScenario provides information on the cask distribution in the NPPs and in the interim storage facility automatically, by displaying it in real time according to the shipping routes, cask types and cask numbers that the user generates. Once a yearly transportation schedule is established, TranScenario provides some statistical information, such as the voyage time, the availability of the interim storage facility, the number of transported casks sent from the NPPs, and the number of transported casks received at the interim storage facility. By using this information, users can verify and validate a yearly transportation schedule. In this way, the 24 candidate scenarios could be constructed easily. Finally, these 24 scenarios were compared in terms of their operation cost.

The effects of introduction of diesel passenger cars on the ventilation requirements for road tunnels (경유승용차 도입이 터널 소요환기량에 미치는 영향분석)

  • Kim, Hyo-Gyu;Song, Seok-Hun;Kim, Nam-Young;Lee, Chang-Woo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.9 no.3
    • /
    • pp.309-321
    • /
    • 2007
  • Since the first diesel passenger car hit the local road in late 2005, the share of diesel cars is growing significantly; possibly up to the level as in the western Europe. In this study, the effects of introduction of diesel passenger cars on the ventilation rate and facility capacity are analyzed for the three individual cases with different basic exhaust rate based on the vehicle age, the vehicle class percentage and the smoke exhaust rate. The target tunnel for this comparative study is a typical 2 km-long 2-lane highway tunnel. Case 1 assuming the current local design standards and the diesel vehicles comprising 40% of the total passenger cars on the road required more ventilation rate and facility capacity than in the case only with the current standards. Case 2 which is the real tunnel currently in the designing stage taking into account the vehicle age but ignoring the diesel vehicle ratio, and Case 3 on the contrary considering the both factors show similar level of ventilation characteristics as EURO-3 emission regulation. Application of the emission standard set by the Ministry of Environment for newly manufactured vehicles in the current local tunnel design standard indicates higher requirements than for EURO-2 regulation, whereas the emission standard came into effect in 2006 results in the ventilation characteristics similar to EURO-4. This study aims at providing fundamental information for assessing the basic emission rate and determining the optimal ventilation rate and facility capacity considering the growing percentage of diesel cars and gradually decreasing level of smoke emission forced by the relevant laws.

  • PDF