• 제목/요약/키워드: Facilities and Data Standards

검색결과 268건 처리시간 0.034초

경남지역 고등학교시설의 생태환경 실태에 관한 사례 연구 (A Case Study on the Actual Conditions of Ecological Environment of the High School Facilities in Gyeongnam Area)

  • 양금석
    • 한국농촌건축학회논문집
    • /
    • 제12권1호
    • /
    • pp.57-64
    • /
    • 2010
  • This study is to clarify the actual conditions of high school of environment friendly architecture per ecological environment elements through extracting ecological environment elements which is possible to analyze in quantity certification standards of environment friendly architecture. As the method of the study, First, certification as an examination on certification system of environment-friendly architecture, summary of certification system of environment friendly architecture and certification high school, ecological environment elements which is possible for quantitative analysis of ecological environment certification standards were extracted. Second, actual condition of ecological environment elements per non-certification high school by collecting actual data of certification schools environment friendly architecture were analyzed and the results are as the follows. The average of ecological area ratio was 17.8 percent in case of non-certification school facilities it was analyzed that the natural based green area ratio was 17.5 percent, continuous green axis length ratio was 19.0 percent and roof green garden area ratio was 0 percent.

감염 예방을 위한 인공신장실 의료 환경에 대한 고찰 - 근거 기반의 디자인 중심으로 (A Review of Renal Dialysis Unit Environment for Infection Prevention - Focused on Evidence Based Design)

  • 한수하;윤형진
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제24권3호
    • /
    • pp.49-57
    • /
    • 2018
  • Purpose: The increase in patients requiring hemodialysis has resulted in an increase dialysis-associated infections risk. but there are no Renal Dialysis unit design standard meet specified safety and quality standards. Therefore, appropriate Establish standards and legal regulation is important for the provision of initial certification and maintenance of facility, equipment, and human resource quality. Methods: Literature survey on the design guideline and standards of Renal Dialysis unit design in Korea, U.S, Germany, Singapore, Hongkong, Dubai. Results: There are no established standards for facilities in dialysis units in Korea. To prevent infections in dialysis patients, necessary establish standards. Considering the domestic and overseas Health-care facilities standards, the major factors to be considered in the medical environment for Renal Dialysis Unit are as follows. First, planning to separate Clean areas(treatment area) from contaminated areas(medical waste storage area). Second, ensure sufficient space and minimum separation distance. Although there may be differences depending on the circumstances of individual institutions, renal dialysis unit consider the space to prevent droplet transmission. Third, secure infrastructure of infection prevention such as sufficient amount of hand hygiene sinks. Hand washing facilities for staff within the Unit should be readily available. Hand hygiene sinks should be located to prevent water from splashing into the treatment area. Fourth, Heating, ventilation and air conditioning (HVAC) system for Renal Dialysis Unit is all about providing a safer environment for patients and staff. Implications: The results of this paper can be the basic data for the design of the Renal Dialysis Units and relevant regulations.

다중이용시설별 실내공기 오염물질 농도분포 및 기준치 이상 값의 구성비 조사 (The Distribution of Indoor Air Pollutants by the Categories of Public-Use Facilities and Their Rate of Guideline Violation)

  • 전정인;이혜원;최현진;전형진;이철민
    • 한국환경보건학회지
    • /
    • 제47권5호
    • /
    • pp.398-409
    • /
    • 2021
  • Background: The types and effects of hazardous pollutants in indoor air may vary depending on the characteristics of the sources and pollutants caused by physical and chemical properties of buildings, the influence of outdoor air, and the exposure and use characteristics of residents. Objectives: This study was conducted to provide basic data on the establish of indoor air quality management for different classes of public-use facilities by presenting the characteristics of concentration distribution of hazardous pollutants by different public-use facilities and the status of the excess proportion of exceeding standards. Methods: This study analyzed self-measurement data from public-use facilities taken from 2017 to 2019 A total of 133,525 facilities were surveyed. A total of 10 types of pollutants that have maintenance and recommended standards stipulated in the Indoor Air Quality Control Act from the Ministry of Environment were investigated. The excess proportion and the substances exceeding the criteria for each type of public-use facilities for these pollutants were investigated. Results: As a result of the analysis of the proportion of exceeding the standard for each type of public-use facility, the facilities with the highest excess proportion of the standards for each hazardous pollutant were: PM10 in railway stations (8.93%), PM2.5 in daycare centers (7.36%), CO2 in bus terminals (2.37%), HCHO in postpartum care centers (4.11%), total airborne bacteria in daycare centers (0.69%), CO in museums (0.1%), NO2 in postpartum care centers (1.15%), Rn in museums (0.78%), total volatile organic compounds in postpartum care centers (7.20%) and mold in daycare centers (1.44%). Conclusions: Although uncertainty may arise because this study is a result of self-measurement, it is considered that this study has significance for providing basic data on the establishment in the future of indoor air quality management measures customized for each type of public-use facility.

무등산(無等山) 도립공원(道立公園) 시설물(施設物)의 관리상태(管理狀態) 평가(評價)와 개선방안(改善方案) (Evaluation of the Present Management Conditions for the Facilities in Moodeung-san Provincial Park)

  • 김상오;오광인
    • 한국산림과학회지
    • /
    • 제87권4호
    • /
    • pp.590-600
    • /
    • 1998
  • 본 연구에서는 규범적 접근방법을 이용하여 무등산 도립공원의 주요 시설물에 대한 평가기준을 설정하고, 설정된 평가기준을 토대로 공원의 현 시설물 관리상태를 평가하였으며, 여기에서 발견된 문제점을 해결하기 위한 개선방안을 제시하였다. 데이터는 1996년 8월 중 무등산 도립공원에서 현지설문조사와 우편설문조사에 의하여 수집되었으며, 총 1,173명의 조사대상자 중 519명(44.2%)이 본 연구의 분석에 이용되었다. 결과에 따르면, 선정된 5개 지표항목 중 '쓰레기통 충분여부'와 '등산로 안내시설 충분여부'를 제외한 3개 지표항목(화장실 충분여부, 화장실 청결상태, 대중교통수단을 이용하기 위하여 기다려야 하는 시간)에서 현 상황이 명가기준보다 불량한 것으로 나타났다. '등산로 안내시설 충분여부'에 대한 현 상황은 평가기준과 동일하였다. 문제점이 있는 것으로 밝혀진 지표항목에 대해서는 이를 개선하기 위한 관리대안을 제시하였으며, 이러한 자료들이 공원 시설물관리를 위하여 어떻게 이용될 수 있을 것인가를 소개하였다.

  • PDF

Study on efficient financial income elderly long-term care facilities size

  • Jeong, Seong-Bae
    • 한국컴퓨터정보학회논문지
    • /
    • 제21권10호
    • /
    • pp.157-166
    • /
    • 2016
  • The aims of this study are to contribute to efficient revenue management by analysis of the scale in elderly long-term care facilities. The data was used for input of the elderly long-term care costs Scale, and calculated the staffing standards and social welfare facilities workers with living wage guidelines in the Department of Health and Human Services. Revenue efficiency is the highest order of size are as follows. I8(98 people) \43,517,010, H6(86 people) \36,568,332, G8(78 people) \29,426,532, F8(68 people) \23,227,532, E8(58 people) \19,701,254, D8(48 people) \19,155,187, C6( 36) \14,389,109, B8(28 people) \9,920,031, A8(18 people) \3,721,031. It seems that its revenue efficiency even higher than the larger the scale. Meanwhile, The researchers focused on C6 (36 patients) model. Suggestion of this study are following; First, the arrangement can be provided based on needs of the elderly care facility staffing standards. Secondly, an elderly care facility selected wage guidelines. Thirdly, the elderly efficiency guidelines established by the size of a nursing facility. This study and other financial income factor are not the applicable limits.

원전 생애주기간 설계기준 정보관리를 위한 요건 분류체계 개발 (Development of Requirement Taxonomy for Design Bases Management during NPP lifecycle)

  • 김종명
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 추계 학술논문 발표대회
    • /
    • pp.134-135
    • /
    • 2018
  • Nuclear Power Plant consists of about 1.4 million facilities. and the design standards and design requirements for the continuos utilization and safety of facilities are complexly connected with the facilities. When a design change for facilities or design requirements is occurred at the time of construction or operation, there are a lot of facilities, design requirements, and design bases that are affected by the facilities or design bases being changed. The above design changes are so complex that the existing document-bases design change process is time-consuming and may also cause human error. In this study, we developed a design requirement taxonomy that can be applied to the data-centric design bases document that can improve it. To do this, we analyze the design elements from the highest level to the lowest level applied to the nuclear power plant, and classify the design elements according to the characteristics of the design elements.

  • PDF

사물인터넷 기반 전기안전 기술 및 표준화 동향 (Trends in standardization of IoT based electrical safety technology)

  • 안윤영;김성혜;정상진;강현주
    • 전자통신동향분석
    • /
    • 제35권1호
    • /
    • pp.49-59
    • /
    • 2020
  • This paper describes an IoT-based electrical safety management system for managing the electrical power distribution systems in factories or buildings and for managing private electrical devices in apartment complex. The IoT-based electrical safety management system collects IoT data from the electrical facilities or devices to provide various electrical safety services. In some cases, it uses an IoT adaptor to collect data from legacy facilities. By monitoring and analyzing the IoT data, it is possible to provide protection from and prevent electrical hazards. In addition, an IoT-based electrical safety management system can benefit from using the IoT identification system and standardized data model of the electrical facilities and devices. An IoT identification system is used to increase manageability of large-scale electrical facilities which consists of numerous IoT devices. A standardized data model is used to support interoperability. This paper also explores some international and Korean standards related to IoT-based electrical safety management.

항만 BIM 데이터의 상호운용성 확보를 위한 IFC 표준 개발 (Development of IFC Standard for Securing Interoperability of BIM Data for Port Facilities)

  • 문현석;원지선;신재영
    • 한국BIM학회 논문집
    • /
    • 제10권1호
    • /
    • pp.9-22
    • /
    • 2020
  • Recently, BIM has been extended to infrastructures such as roads and bridges, and the demand for BIM standard development for ports is increasing internationally. Due to the low level of utilization of classification system and drawing standards compared to other infrastructures, and the closed nature of national security facilities, ports have insufficient level of connection and sharing environment among external systems or users. In addition, since the standardization of data for port facilities is not made, it is still necessary to establish an independent DB for each system and to ensure interoperability of data between these systems since it does not have a shared environment among similar data. Therefore, the purpose of this study is to develop and verify IFC, the international standard for BIM, in order to cope with the BIM environment and to be commonly used in the design, construction, and maintenance of port facilities. To this end, we build a standard schema with port-specific Express Notation according to buildingSMART International's standard development methodology. First, domestic and international reference model standards were analyzed to derive components such as space and facilities of port facilities. Based on this, the components of the port facility were derived through the codification, categorization, and normalization process developed by the research team. This was extended based on the port BIM object classification system developed by the research team. Normalization results were verified by designers and associations. Then, IFC schema construction was based on Express-G data modeling based on IFC 4 * 2 Candidate, which is a bridge candidate standard based on IFC4 (ISO16739), and IFC 4 * 3 Draft, which is developed by buildingSMART International. The final schema was validated using the commercialized validation tool. In addition, in order to verify the structural verification of the port IFC schema, the transformation process was verified by converting the caisson model into a Part21 file. In the future, this result will not only be used as a delivery standard for port BIM products, but will also be applied as a linkage standard between systems and a common data format for port BIM platforms when BIM is used in the maintenance phase. In particular, it is expected to be used as a core standard for data exchange in the port maintenance stage.

학교시설에서의 건축용 유리의 안전사고 실태와 개선방안에 관한 연구 (A study on the risk of injury of architectural glass in educational facilities and the improvement of safety standards)

  • 노승범
    • 교육시설
    • /
    • 제10권4호
    • /
    • pp.21-30
    • /
    • 2003
  • The main goal of this study is to examine the current status of architectural glass in terms of its risk for inflicting injury in elementary schools, middle schools, and high schools. Through objective analysis of data contributed by the investigation of the cause, degree of seriousness, and bodily location of injury, the hazardousness of architectural glass in educational facilities will be evaluated. Most importantly, this study is an attempt to increase awareness of the need for establishing a safety standard in the installation of safety glass in order to prevent injuries inflicted by architectural glass in educational facilities.

실외 어린이 놀이터 놀이시설의 안전도에 관한 조사 (A Study on Playground Equipments′ Safety in the Outdoor Playground for Children)

  • 박은희;김현진;석주영;안옥희
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2000년도 학술발표대회논문집
    • /
    • pp.149-153
    • /
    • 2000
  • This study purposed to suggest basic data for establishing safety standards of play equipments by measuring actually the playground facilities which were installed at the playground and examining whether they were suitable to the standards or not. The results which investigated 59 outdoor playground locating in Taegu were as follow. As it examined in this study, the standards for swing and slide were established detailly and actual measurement's results were suitable to standards' value as well. Also the standards for seesaw and climber were not in detail and they were intend to design or install unsuitably in outdoor playground for children.

  • PDF