• Title/Summary/Keyword: Facilities Standards

Search Result 1,130, Processing Time 0.036 seconds

A Study on the Safety Grounding for Prevention of Electric Shock Hazard in Construction of Industrial Plant in Maritime Landfill Area (해상 매립 지역 산업 플랜트 건설 시 감전 재해 예방을 위한 안전 접지에 관한 연구)

  • Kim, Hong-Yong;Jang, Ung-Burm
    • Journal of the Society of Disaster Information
    • /
    • v.13 no.3
    • /
    • pp.305-312
    • /
    • 2017
  • In our society, the advanced, advanced, and information industries have continued to grow and now live in the era of the fourth industrial revolution. As the industry develops, the load of the users has also increased so much that it is deepened by the energy shortage phenomenon and the construction of additional energy facilities is required. Therefore, energy plant construction work is being actively carried out in the coastal area. In particular, it is common to build a plant in the ground by filling the coast with soil in other regions, reflecting the fact that Korea is lacking in the country when constructing power plants, gas and petrochemical plants. Current domestic grounding designs are designed or constructed to suit only the use of grounding resistors based on the electrical equipment design technical standards. However, in the case of a plant facility constructed in the untested buried soil, when the lightning current and the abnormal current are inputted, the facility operator or the user due to the elevation of the ground potential is seriously exposed to the risk of electric shock disaster. In this paper, we analyze the ground resistivity of the landfilled soil and use a computer program (CDEGS) based on KS C IEC 61936-1, We analyze the contact voltage and stratification voltage and propose a grounding design optimized for plant installation.

Configuration of Test Field for Introduction of IEC 60364-4-44 to Domestic System (IEC 60364-4-44의 국내 도입을 위한 실증시험장 구성)

  • Nam, Kee-Young;Choi, Sang-Bong;Jeong, Seong-Whan;Lee, Jae-Duck;Ryoo, Hee-Suk;Kim, Dae-Kyeong;Jung, Dong-Hak
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.731-732
    • /
    • 2007
  • This paper presents the final configuration of test field and test items for the application of IEC 60364-4-44 in Korea. IEC 60364-4-44 provides rules for the protection against the effects of conducted and radiated disturbances on electrical installations. Especially this standard deals with the protection of low voltage facility against the ground fault in the high voltage side of power distribution system. Many countries define the regulations on the use of electrical facilities based on their own power system and technical references which are considered to be suitable for them. The background of circuit of IEC 60364-4-44 is based on the ungrounded system as most of European countries. However, domestic electric power distribution system is based on multi-grounding system different from European system. Therefore, it is necessary to evaluate or prove the effect of the IEC 60364-4-44 for introducing and applying it to the domestic grounding system as a national standard. The authors with KEA(Korea Electric Association) carried out a project on the application of IEC 60364-4-44 to Korean electrical installations of buildings sponsored by Korean ministry of commerce, industry and energy for three years(2004.4.1$\sim$2007.3.31). The test field is established in K.E.R.I.(Korea Electrotechnology Research Institute), which is the purpose of evaluating the formula to calculate touch voltage and stress voltage in the IEC standards. This paper presents some considerations and final configuration of test field to evaluate and introduce the IEC 60364-4-44 applicable to domestic rule for the protection against ground fault.

  • PDF

Analysis of the Current Situation and Improvement Method of Correctional Facility Libraries in Korea (한국의 교도소도서관 현황분석과 개선방안)

  • Kwon, Se-Hee;Yoon, Hye-Young
    • Journal of Information Management
    • /
    • v.40 no.3
    • /
    • pp.125-150
    • /
    • 2009
  • This study aims to investigate current situation and improvement method of correctional facility libraries in Korea. Thus this study made the following suggestions to improve the operation of correctional facility library and to facilitate its growth so that the inmates' basic right to know and access information could be guaranteed: First, there should institutional and legal grounds for the establishment and operation of correctional facility library such as standards, guidelines, and enactments; second, the government should provide enough budgets for human and material resources so that a prison library can equip itself with materials, facilities, and staff to run smoothly; third, the inmates' free access to the library service should be guaranteed in an open space; fourth, the library should introduce an automation system for lending, returning, and handling materials; fifth, a collaboration system with external resources should be set up to make effective use of lacking resources; sixth, programs should be researched and developed to analyze the size and composition of the inmates, the needs of the inmates, and available service; and finally, there should be staff with the qualification of a librarian to be responsible for the operation and management of a correctional facility library and to offer specialized library service to the inmates.

Extraction of Road Structure Elements for Developing IFC(Industry Foundation Classes) Model for Road (도로분야 IFC 확장을 위한 도로시설의 구성요소 도출)

  • Moon, Hyoun-Seok;Choi, Won-Sik;Kang, Leen-Seok;Nah, Hei-Sook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.2
    • /
    • pp.1195-1203
    • /
    • 2014
  • Since IFC (Industry Foundation Classes) 4 is based on the representation of 3D elements for an architecture project, and does not define standardized shapes for civil projects such as roads, bridges, and tunnels etc, it has limitations in securing interoperability for exchanging a shape information model for the civil projects. Besides, since road facilities have a linear reference, which is modeled along the center alignment, it is difficult the designers to create a standardized 3D road model. The aim of this study is to configure structure elements and their attribute for a road in the perspective of 3D design for developing a shape information model for the road. To solve these issues, this study analyzes the design documents, which consist of a road design handbook, guide, specifications and standards, and then extract shape elements and their attributes of road structures. Such shape elements are defined as an entity item and we review a hierarchical structure of a road shape defined by a virtual road model. The detailed elements and their attributes can be utilized as a 3D shape information model for constructing BIM (Building Information Modeling) environment for Infrastructures. Besides, it is expected that the suggested items will be utilized as a base data for extending to IFC for a road subdividing the detailed shapes, types and attributes for road projects.

Airport security supervisor's individual attitude effets on the screening equipment factors (공항보안감독관의 개인태도가 검색장비 운영요인에 미치는 영향)

  • Jung, Joo-Sub
    • Korean Security Journal
    • /
    • no.29
    • /
    • pp.279-300
    • /
    • 2011
  • Countries recognize seriousness and concern about aviation terrorism, try to stamp out of it but aviation terrorism has been increasing in the world. Airport security is completely up to the result of security screening for passengers, check-in baggages and cargo at the check point. To complete effectively human and physical screening at the airport, it is essential to secure modernized screening equipment and specialized security screener, and airport security supervisor to supervising them. In this study, A survey conducted to find out the effect on screening equipment operating factors of airport security supervisor's individual attitude. The results of the study are as follow First, the duty view of airport security supervisor meaningfully affect expertise of screening equipment operating factors, satisfaction, reliability, and education and training, national point of view meaningfullly doesn't affect screening equipment operating factors. Second, the working condition effects on the education and training, if the working condition is getting better, intent to change occupation is getting lower. Third, duty stress meaningfully effects on the intent to change occupation, now airport security supervisor works in poor condition. Therefore, airport security supervisor needs to be prude of protecting the airport from the terrorism and various attacks and various kinds of aviation security regulations and procedures and comply with operating standards and keep the life of the country and its people, and needs to change awareness. And It is nessasary for government or airport authority or airline to prepare countermeasure for the improvement of their labor conditions.

  • PDF

Characteristics of Unsold Land and Sites Needing Value Enhancement (미매각 토지의 원인진단 및 가치제고 사업지구 선정 방안)

  • Jeong, Yeun-Woo;Lee, Sang-Jun;Seong, Jang-Hwan
    • Land and Housing Review
    • /
    • v.4 no.3
    • /
    • pp.259-270
    • /
    • 2013
  • This paper defined the concept of unsold land and diagnosed the cause of unsold land of LH business site. The results are showing as follows. First, unsold land is defined as land could not be sold until the completion of the project, and plan to sell the unsold land can be changed partially. Second, the status of unsold land in the 226 project sites were analyzed. $146km^2$ area corresponding to 74.8% of the total capital area($195km^2$) are unsold. By purpose, co-residential($38km^2$), industry($21km^2$), exclusive residential($16.4km^2$), commercial business($12.5km^2$), education($10.2km^2$) was larger in order. Third, value enhancement target project sites were selected and its symptoms and the cause of unsold land were analyzed. For the project site over average unsold rate, 6 sites located in province and 2 sites located in capital region were selected through collecting the practitioners and expert opinion. These 8 sites are characterized that sale of land for medium and large co-residential, urban support facilities, block-shaped house and attached house was inactive. Also, these sites commonly experienced economic fluctuations, changes in market demand, supply and demand mismatch, inflexible planning standards.

Comparative analysis of caisson sections of composite breakwaters evaluated by Level I reliability-based design method (Level I 신뢰성 기반 설계법에 의해 산정된 혼성제 케이슨 단면의 비교 분석)

  • Lee, Cheol-Eung;Park, Dong Heon;Kim, Sang Ug
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.7
    • /
    • pp.543-554
    • /
    • 2018
  • A methodology has been presented for evaluating the partial safety factors on the sliding failure mode of vertical caissons of composite breakwaters and for determining the cross sections of those by Level I reliability-based design method. Especially, a mathematical model has been suggested for the sake of a consistency of code format as well as convenience of application in practical design, for which the uncertainties associated with buoyancy and its own weight can be taken into account straightforwardly. Furthermore, design criteria equation has been derived by considering accurately the effect of uplift pressure, so that the cross sections of caissons can be assessed which must be safe against the sliding failure. It has been found that cross sections estimated from partial safety factors proposed in this paper are in very good agreement with the results of Level II AFDA and Level III MCS under the same target probability of failure. However, partial safety factors of the Technical Standards and Commentaries for Port and Harbour Facilities in Japan and Coastal Engineering Manual in USA tend to estimate much bigger or smaller cross sections in comparison to the present results. Finally, many reliability re-analyses have been performed in order to conform whether the stability level of cross section estimated by Level I reliability-based design method is satisfied with the target probability of failure of partial safety factors or not.

A Study on the Improvement Plan of Electrostatic Safety Management Level through Injury Analysis (재해분석을 통한 정전기 안전관리 수준 향상 방안 연구)

  • Choi, Sang-won;Jeong, Seong-Choon;Park, Jae Suk;Yang, Jeong Yeol;Byeon, Junghwan
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.5
    • /
    • pp.37-45
    • /
    • 2019
  • The characteristic of fire and explosion related to electrostatic discharge is that it is difficult to reproduce the electrostatic charge and discharge phenomenon in addition to the large human and material damage. Therefore, in order to prevent accidents and disasters related to electrostatic in fire and explosion hazard areas, it is important to manage the level of electrostatic in a safe manner from the perspective of system between industrial facilities and human bodies. Rule 325 of the Occupational Safety and Health Regulations, "Prevention of Fire / Explosion due to Electrostatic", requires the use of grounding, conductive materials, humidification and electrification in order to prevent the risk of disaster caused by static explosion and electrostatic in the production process. In order to comply with these measures, related technologies, standards and systems are needed from the viewpoint of preventive measures related to electrostatic in fire and explosion hazard areas, but in Korea, it is still insufficient. Therefore, technical, institutional and managerial measures are needed as a precautionary measure to improve the level of ESD safety in fire and explosion hazard areas and prevent electrostatic related injury. In Korea, we analyzed the current status and characteristics of electrostatic related disaster by using the statistics of industrial accident and fire statistics of the Ministry of Employment and Labor. We also analyzed the current status and characteristics of electrostatic related disasters in Japan using JNIOSH accidents and disasters investigation cases and JNIOSH fire accident data of Japan Fire Bureau. The purpose of this study is to compare and analyze the current status of electrostatic related accidents and disasters in Korea and Japan in order to improve the safety management of electrostatic in fire and explosion hazard areas. In order to prevent accidents and disasters in the industrial field, The technical, institutional, and managerial measures to manage the level of electrostatic in a safe state were derived from the system point of view.

Current Status and Needs Assessment for Obesity Prevention and Management Project at Public Health Centers (보건소 비만예방관리 사업 현황 및 요구도 분석)

  • Park, Jiyoung;Im, Mihae;Baek, Seolhyang;Park, Chongwon;Hwang, Gahui;Kim, Wansoo;Oh, Yumi;Cho, A Ra;Jo, Jieun
    • Research in Community and Public Health Nursing
    • /
    • v.32 no.3
    • /
    • pp.368-381
    • /
    • 2021
  • Purpose: The obesity prevention and management program led by public health centers are important in the community. This study aims to identify the current status of obesity prevention and management programs at public health centers and perceptions regarding facilitators and barriers when implementing programs. Methods: This study used a concurrent mixed methods design. A survey was conducted to investigate the current status and infrastructure of the obesity prevention and management program at eighty-three public health centers nationwide. Nine program managers and six local residents with experience in the program were interviewed by using a semi-structured questionnaires. Results: Most of the infrastructure facilities for the program were inadequate, and insufficient budgets and lack of professional staff were identified as barriers. Facilitators included diversification of program delivery methods, operator competence, and visible outcomes and rewards. For the effectiveness of the program, it is vital to have adequate assistants, a sufficient budget, various promotional methods, and connections with various institutions in the community. On this basis, it is acknowledged that the public health center serves as a platform for preventing and managing obesity in the community. Conclusion: It is expected that infrastructure improvements in public health centers and the link with community resources are needed. In addition, there is an urgent need to set standards for obesity prevention and management programs implemented in public health centers to 'resolve regional disparities'.

A Study on Energy Efficiency Improvement through Building Insulation Diagnosis (건축물 단열 진단을 통한 에너지 효율 개선에 관한 연구)

  • Cho, Kwangmoon
    • Journal of Internet of Things and Convergence
    • /
    • v.7 no.3
    • /
    • pp.9-14
    • /
    • 2021
  • This paper discovers the energy loss factors through the insulation diagnosis of houses or buildings, and proposes directions for energy efficiency improvement. The energy efficiency factor of a building consists of insulation diagnosis, thermal bridge diagnosis, window diagnosis, airtight diagnosis, and equipment diagnosis. Among the residents and facilities in the energy welfare blind spot, an energy efficiency diagnosis was conducted for one senior citizen building located in Naju-si, Jeollanam-do, and energy efficiency diagnosis was conducted after insulation was installed. Energy measurement, diagnosis and analysis were performed using the IoT-based integrated wired/wireless energy diagnosis platform, Energy Finder. As a result of comparison, an overall energy saving rate of 16.38% was achieved. Annual heating energy consumption per unit area decreased from 333.51kWh before construction to 277.35kWh after construction, and annual cooling energy consumption per unit area decreased from 5.51kWh before construction to 5.22kWh after construction. The annual primary energy consumption per unit area decreased from 464.52kWh before construction to 403.69kWh after construction, and the annual energy cost was reduced from 3,063,307.14 won before construction to 2,641,072.49 won after construction. The additional improvement work is needed on the standards affecting energy efficiency other than insulation.