• Title/Summary/Keyword: Facade Design Factor

Search Result 29, Processing Time 0.025 seconds

Comparative Analysis on the Heating and Cooling Loads Associated with U-value, SHGC and Orientation of the Windows in Different Regions (창호의 열관류율, 일사취득계수와 향의 배치가 건물의 냉난방 부하에 미치는 영향에 관한 지역별 비교연구)

  • Choi, Min-Seo;Chang, Seong-Ju
    • KIEAE Journal
    • /
    • v.13 no.2
    • /
    • pp.123-130
    • /
    • 2013
  • The primary goal of this research is to identify the impacts of window design on the energy use in buildings which takes up about 25% of the total energy consumption. Recently, efficient use of energy is gaining more importance in buildings. Window design, especially being dependent on glazing performance choices, is an important factor for reducing energy consumption in most of the buildings. It also is influenced by the latitude of the site and window orientation. This paper aims at identifying the influence of Window performance indicators(U-value, SHGC), orientation and latitude on the building energy consumption with systematically designed simulations. Comparative study has been performed for five different locations; Greenland, Korea, Singapore, Argentina and Chile along with the different window U-value and SHGC values. The results show that optimum window system with properly coordinated window performance indicators(U-value, SHGC), orientation achieves dramatic reduction of energy consumptions. Windows with low U-value could reduce heating loads and high SHGC could reduce cooling loads. The study also verifies that the windows installed at south facade is more energy efficient in the northern hemisphere while windows facing north is more energy efficient in the southern hemisphere.

Space study on Lighting Performance For Residential Buildings By using Simulation Analysis (시뮬레이션 분석기법을 이용한 주거용 건물의 공간별 채광성능 연구)

  • Lim, Tae Sub;Lim, Jung Hee;Kim, Byung Seon
    • KIEAE Journal
    • /
    • v.13 no.3
    • /
    • pp.97-104
    • /
    • 2013
  • This proposed simulation-based design study is based on the design of residential high-rise buildings in South-Korea. the purpose of this study is to evaluate the amount of daylighting performance passing through building glazing according to sky conditions, orientation of windows and each space of Apartment buildings. The clear sky includes sunshine and is intense and brighter at the horizon than at the zenith, except in the area around the sun. Daylight received within a building is directly dependent upon the sun's position and the atmospheric conditions. Orientation of the building generally used to refer to solar orientation which is the siting of building with respect to solar access. Although any building will have different orientations for its different sides, the orientation can refer to a particular room, or to the most important facade of the building. north-facing windows receive twice the winter sun than east and west facing windows, allowing light and warmth into the home. They can be easily shaded from the high summer sun to help keep the house cool. Ideally, the glazing area should be between 10-25% of the floor area of the room. This paper was calculated by a Desktop Radiance program. The space dimensions were based on a unit module of real constructed apartment having divided into five sections such as living room, room1, room2, room3 and kitchen.

The Study on Robert Venturi's Contextual Approaches in his early theories and works (벤투리의 초기 이론과 작품에 나타난 맥락적 사고에 관한 연구)

  • Park, Hyung-Jin;Kim, Ja-Kyung
    • Korean Institute of Interior Design Journal
    • /
    • v.18 no.5
    • /
    • pp.49-58
    • /
    • 2009
  • Robert Venturi's theories like 'Complexity and Contradiction in Architecture' and 'Symbolism of Architecture' had a major impact on architects in postmodern culture and we could have his contextual understandings in those theories. In his early books, "Complexity and Contradiction in Architecture" and "Learning from Las Vegas", Robert Venturi showed theories related to context several times. But with looking at existing books or papers, we could barely see well-organized studies about his contextual understandings. So this study shows contextual approaches and thoughts with those theories, 'Complex and contradictory architecture', 'Architectural order and conventional architecture', 'Discontinuity in internal and external architecture', and 'Symbolism of architecture' in his two books. In those four theories, Venturi's contextual understandings are as fellows. To begin with, he developed contextual theories in architecture, understanding a whole building embracing each architectural factor, with architectural thoughts of complexity and contradiction. Second, he stressed architectural order to link each contradictory factor and used conventional architecture, as for existing common and ordinary things, to make available communication. Conventional factors were applied to urban viewpoints. Given the fact that contemporaries shared those factors, we could see contextual understandings in his approach. On top of that, unlike modern architects, he understood that functions of the inside and the outside were two different things. Based on contextual thoughts, he tried applying 'facade' that is one side providing an interface between in and out of a building to surroundings. Last, he wanted to express any meaningful connection between present and past, using symbolism in architecture. Presented by symbolism of architecture, architectural functions, architectural uses, historical meaning, ordinary factors, or something were also based on sharing in contemporary people. As the methodology to show these contextual factors, Venturi used an approach of symbolism.

A Study on the Style of 18th Century House at the Historic Place of Deerfield (미국 디어필드 18세기 주택의 표현특징)

  • Kim Jung-Keun
    • Journal of Families and Better Life
    • /
    • v.24 no.1 s.79
    • /
    • pp.287-297
    • /
    • 2006
  • The purpose of this study is to investigate the traditional American houses in eighteen century and their specific styles at the historic pace of Deerfield. The results of this study were as follow: First, Village of Deerfield is founded by Henry Flynt and PVMA(Pocumtuck Valley Memorial Association). Their preservation and restoration has been achieved from the efforts of collection constantly and the concrete research of old houses. So, It should be reflected their way of approach to preserve and restore for old houses in Korea. Second, the traditional eighteen century houses in Deerfield had generally Colonial Style. Style of Colonial houses had a "L"shape exterior view and a flat facade and the front door made a symmetry with sash windows. A chimney had been installed in the middle of the roof and it usually had a gable with natural materials in a simple manner. Third, the most important factor to design houses was a front door and it had been decorated in luxury and in a display. Lastly, the traditional American houses in eighteen century had been greatly influenced not by the that of British which is commonly taken but by the various cultural backgrounds which represented regional characteristics and was rather simple.

A Study on Characteristics of Indoor space and Food related of Japanese restaurant as successful model for globalizing Korean restaurants - Japanese restaurants in Hong Kong - (한식당 세계화를 위한 성공모델로서의 일식당 실내공간과 음식관련요소의 특성 연구 - 홍콩 소재 일식당 대상 -)

  • Lee, Ji-Hyun;Oh, Hye-Kung
    • Korean Institute of Interior Design Journal
    • /
    • v.18 no.1
    • /
    • pp.54-63
    • /
    • 2009
  • The present study is a basic research for promoting the globalization of Korean food, aiming to analyze Japanese restaurants in Hong Kong, an international city successful in globalization, focused on their spatial characteristics and food related characteristics and to use the results as basic materials. The results of this study are as follows. As to the characteristics of indoor spaces and food of Japanese restaurants in Hong Kong, first, the locations of Japanese restaurants were mostly easily accessible luxury hotels, office buildings or shopping malls. They displayed Japanese styles well and used conspicuous signs. Their trade names were given after traditional place names, food names, greetings, etc. Second, the spaces of Japanese restaurants expressed contemporary and, at the same time, traditional styles moderately and elegantly by applying emphatic articles such as traditional furniture, tools and folk paintings to contemporary spaces with traditional air, and by doing so, they showed various possibilities. Third, as to the characteristics of food culture, menus were diversified from traditional menus such as kaiseki to everyday menus such as vinegared rice, ramen, skewered roast meat and fusion dish, and at the same time, differentiated by concept. In addition, some restaurants succeeded in globalization and modernization with chains throughout the world. Furthermore, while table setting, food dishing and tableware image were harmonized with the concept of the restaurant space, if tradition needed to be displayed it was used at a minimum, showing the Japanese aesthetic sense through the restaurant space and food. In globalizing Korean restaurants based on the results of this study, we need to link trade name, facade, sign, menu and space with served food, and to plan a consistent story so that Korean culture and images are expressed. In addition, if a manual is made by benchmarking the Japanese government's support policies and relevant businesses' efforts and ideas and provided to Korean restaurants, it will be helpful for Korean restaurants, which spread Korean food culture, to be more competitive and graceful.

A Study on the correlation between a streetscape image and a signboard density - Focused on roadside buildings occupation density of signboard in the business area - (가로경관이미지와 간판밀도와의 상관관계에 관한 연구 - 상업지역 연도건물의 간판 점유밀도를 중심으로 -)

  • Kim, Yun-Hee;Rhee, Jae-Won
    • Archives of design research
    • /
    • v.18 no.4 s.62
    • /
    • pp.287-296
    • /
    • 2005
  • The street image in a business area is so much affected by Facade that the front side of a roadside building makes. Recently, for the indiscreet and intemperate advertising signboard of the front side of roadside buildings, a streetscape becomes more disordered than before, so now we need to do research about signboards of roadside buildings for a streetscape image. In this research, we focused on a streetscape with difference of occupation density of signboard in the business area via investigation and analysis about occupation density of signboards of the front side of roadside buildings, and we suggested optimum occupation density of signboards for supporting the road image positively. An object of research is the street in the business area that has many pedestrians and active passing zone of cars. We investigated and analyzed how to feel street images on the rate of occupation density of roadside building's signboards of in the chosen street. As a result of using an adjective that we use for estimating street view images for extraction of street images, we could know 2 factors. We named that one is the image of recognition, and the other is the image of feelings. We knew that signboard density of street of heavily recognized images is from 20% to 30% and, signboard density of street of heavily feeling images is from 50% to 60%. We also could know that people feel both images of recognition and images of feeling in specific density, 30 to 50%. Through this result of research, we can suggest Facade on signboard density with the recognition and the feeling and use images of the street view as materials to be more specific and more special.

  • PDF

The Development of the Simple SHGC Calculation Method in Case of a Exterior Venetian Blind Using the Simulation (시뮬레이션을 이용한 외부 베네시안 블라인드의 약식 SHGC 계산법 개발)

  • Eom, Jae-Yong;Lee, Chung-Kook;Jang, Weol-Sang;Choi, Won-Ki
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.2
    • /
    • pp.73-83
    • /
    • 2015
  • When it comes to these buildings for business use, cooling load during summertime was reported to have great importance which, as a result, impressively increased interest in Solar Heat Gain Coefficient (SHGC). Such SHGC is considered to be lowered with the help of colors and functions of glass itself, internal shading devices, insulation films and others but basically, these external shading devices for initial blocking that would not allow solar heat to come in from outside the buildings are determined to be most effective. Of many different external shading devices, this thesis conducted an analysis on Exterior Venetian Blind. As for vertical shading devices, previous researches already calculated SHGC conveniently using concepts of sky-opening ratios. However in terms of the Venetian Blind, such correlation is not possibly applied. In light of that, in order to extract a valid correlation, this study first introduced a concept called shape factor, which would use the breadth and a space of a shade, before carrying out the analysis. As a consequence, the concept helped this study to find a very similar correlation. Results of the analysis are summarized as follows. (1) Regarding SHGC depending on the surface reflectance of a shade, an average of 2% error is observed and yet, the figure can always be ignored when it comes to a simple calculation. (2) As for SHGC of each bearing, this study noticed deviations of 4% or less and in the end, it is confirmed that extraction can be achieved with no more than one correlation formula. (3) When only the shape factor and nothing else is used for finding a correlation formula, the formula with a deviation of approximately 5% or less is what one would expect. (4) Since the study observed slight differences in bearings depending on ranges of the shape factors, it needed to extract a weighted value of each bearing, and learned that the smaller the shape factor, the wider the range of a weighted value. The study now suggests that a follow-up research to extract a simple calculation formula by dealing with all these various inclined angles of shade, solar radiation conditions of each region (the ratio of diffuse radiation to direct radiation and others) as well as seasonal features should be carried out.

Analysis on Electricity Consumption Characteristics of Apartments based on Architectural Planning Factors - foused on Households with a total area of 132~165㎡ in Seoul- (공동주택 건축계획요소에 따른 전기 에너지 소비특성 분석 - 서울지역의 40평형(132~165㎡)의 단위세대 전기에너지 사용량을 중심으로 -)

  • Park, So-Yun;Lee, Yun-Jae;Lee, Hyun-Soo
    • KIEAE Journal
    • /
    • v.11 no.5
    • /
    • pp.107-117
    • /
    • 2011
  • This paper aims to analyze architectural planning factors that could contribute to reductions in electricity consumption in the household of apartments, to apply energy saving methods at the design phase. These six architectural planning factors were orientation, building type (flat, tower block), standard floor access type (corridor access type, stair case type, EV hall access type), household location (floor), household opening type (one side opening, right angle opening, two sides opening or three sides opening), and bay on the facade (one bay, two bays, three bays, four bays), and these were derived from literature review. Household electricity consumption data were gathered from 2168 households with a total area of 135~150$m^2$ of 6 apartment complexes over 1000 households in Seoul. The annual characteristics of electricity consumption according to architectural planning factors were analyzed. And, variances between groups with respect to the mean of summer, winter, and annual electricity consumption according to each architectural planning factors were analyzed using ANOVA and t-test. The results showed that an annual electric energy saving of over 1000kWh was facilitated by these planning factors. In addition, high energy efficiency architectural planning factors based on the analysis were as follows: southwest orientation, flat type, corridor access type and staircase type, household loation below the 20th floor, two sides opening and three sides opening, and 2 bays and 3 bays.

A Study on Analysis Method for Performance Evaluation of Double-leaf facade of Office Building (업무용 건물의 이중외피 성능평가를 위한 해석기법의 고찰 - 이중외피 설계안의 에너지 저감 성능 및 환기성능을 중심으로 -)

  • Chung, Hwan-Kyo;Chung, Kwang-Seop;Lee, Yong-Jun;Shin, Seung-Chul;Kim, Young-Il
    • Journal of Energy Engineering
    • /
    • v.21 no.2
    • /
    • pp.168-178
    • /
    • 2012
  • The objective of this study is applied to office buildings to evaluate quantitative evaluation method about performance of double-skin at design stage to establish the basis for the purpose of evaluation performance. Select the evaluation building about design plan for applying the double-skin using the dynamic heat load analysis program the annual heating and cooling load of before and after the double-skin. Using CFD to analyze wind factor and applied ventilation for realistic results. Effects of double-skin to apply, and control techniques that can be done more realistically proposed through to set and control for shade control mode of ventilator and inside cavity wall of double-skin. Apply for the building the double-skin due to interpretation of the annual heating and cooling loads applied to interpret the quantitative effect confirmed the possibility. According to the form of a double skin was confirmed cavity environmental changes.