• Title/Summary/Keyword: Fabrication Process

Search Result 4,344, Processing Time 0.047 seconds

Chip-level NFP Calibration and Verification Using Improved Probe for NFS Standardization (NFS 표준을 위한 개선된 프로브를 이용한 칩 수준 NFP 측정값 교정 및 검증)

  • Lee, Pil-Soo;Wee, Jae-Kyung;Kim, Boo-Gyoun;Choi, Jai-Hoon;Yeo, Soon-Il
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.49 no.6
    • /
    • pp.25-34
    • /
    • 2012
  • New calibration method for the near-field scanning (NFS) system is presented. The proposed calibration method consisted of a new near-field antenna (NFP) and newly devised patterns as circular patch patterns (CPPs) and meander patterns (MPs). The proposed patterns were used for improving spatial resolutions and simplifying a calibration procedure of the NFP compared to the conventional method defined in the IEC61967-3 and 6. Also, the effect of the length of NFPs on attenuation characteristics was investigated with length of 8mm and 30mm. For them, we designed and fabricated CPPs of diameter (D) = 20, 40, 60, and 100mm and MPs of various widths and spaces. We found the reverse relations between spatial resolutions and heights of measuring points by using simplified calibration procedure. The testing result shows that the spatial resolution of $120{\mu}m$ at height of $200{\mu}m$ was verified without complex correlation algorithms under 8GHz. For manufacturing cost all patterns and the NFP were realized with low-cost fabrication using PCB (FR-4) not by a conventional LTCC process. For verification of chip-level EMC from the results, near-field scanning system (NFSS) having step resolution of Sub-micron scale was produced and by using the proposed NFSS and proposed NFP measurement of chip shows accurately the shape of the resolution of $200{\mu}m$ patterns for securing a high level of chip-level EMC verification.

The Development of Classification System of Dental Services for Temporomandibular Joint Disorders (측두하악장애 의료행위분류에 관한 연구)

  • Song, Yun-Heon;Kim, Mee-Eun;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.30 no.2
    • /
    • pp.257-268
    • /
    • 2005
  • It is recently suggested in Korea that Resource-Based Relative Value Scale (RBRVS) is an alternative plan of Korean Dental Fee Schedule which has been operated on a fee-for-service basis since the introduction of the national health insurance program in 1977. RBRVS applicable to diagnosis and treatment for temporomandibular disorders (TMD), a common cause of orofacial pain, is needed to be estimated in Korea and the establishment of the standard terminology of dental procedures for TMD should be preceded. The purposes of this study were to develop a new classification system of health care service items for TMD and to investigate time needed for each item, which enables RBRVS to be estimated prior to establishment the payment system of health care services for TMD. The dental service items for TMD in this study were categorized through Delphi process which 10 TMD specialists were participated in and the time needed for each service item was investigated by work sampling and time study method with a stopwatch. The results of this study demonstrated the new classification system of dental services for TMD comprising 151 service items and exhibited the average time for each items ranging from 7.22 min for cold laser therapy to 171.71 min for direct fabrication of anterior repositioning splint. Conclusively, it is suggested that the classification system for TMD developed in this study, considering specific characteristics on basis of resources for health care service of dental procedures, should be helpful to estimate payment level for each service item.

Fitting accuracy of ceramic veneered Co-Cr crowns produced by different manufacturing processes

  • von Maltzahn, Nadine Freifrau;Bernhard, Florian;Kohorst, Philipp
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.2
    • /
    • pp.100-106
    • /
    • 2020
  • PURPOSE. The purpose of this in vitro study was to evaluate the fitting accuracy of single crowns made from a novel presintered Co-Cr alloy prepared with a computer-aided design and computer-aided manufacturing (CAD/CAM) technique, as compared with crowns manufactured by other digital and the conventional casting technique. Additionally, the influence of oxide layer on the fitting accuracy of specimens was tested. MATERIALS AND METHODS. A total of 40 test specimens made from Co-Cr alloy were investigated according to the fitting accuracy using a replica technique. Four different methods processing different materials were used for the manufacture of the crown copings (milling of presintered (Ceramill Sintron-group_cer_sin) or rigid alloy (Tizian NEM-group_ti_nem), selective laser melting (Ceramill NPL-group_cer_npl), and casting (Girobond NB-group_gir_nb)). The specimens were adapted to a resin model and the outer surfaces were airborne-particle abraded with aluminum oxide. After the veneering process, the fitting accuracy (absolute marginal discrepancy and internal gap) was evaluated by the replica technique in 2 steps, before removing the oxide layer from the intaglio surface of the crowns, and after removing the layer with aluminum oxide airborne-particle abrasion. Statistical analysis was performed by multifactorial analysis of variance (ANOVA) (α=.05). RESULTS. Mean absolute marginal discrepancy ranged between 20 ㎛ (group_cer_npl for specimens of Ceramill NPL) and 43 ㎛ (group_cer_sin for crowns of Ceramill Sintron) with the oxide layer and between 19 ㎛ and 28 ㎛ without the oxide layer. The internal gap varied between 33 ㎛ (group_ti_nem for test samples of Tizian NEM) and 75 ㎛ (group_gir_nb for the base material Girobond NB) with the oxide layer and between 30 ㎛ and 76 ㎛ without the oxide layer. The absolute marginal discrepancy and the internal gap were significantly influenced by the fabrication method used (P<.05). CONCLUSION. Different manufacturing techniques had a significant influence on the fitting accuracy of single crowns made from Co-Cr alloys. However, all tested crowns showed a clinically acceptable absolute marginal discrepancy and internal gap with and without oxide layer and could be recommended under clinical considerations. Especially, the new system Ceramill Sintron showed acceptable values of fitting accuracy so it can be suggested in routine clinical work.

Design of a radiation-tolerant I-gate n-MOSFET structure and analysis of its characteristic (I 형 게이트 내방사선 n-MOSFET 구조 설계 및 특성분석)

  • Lee, Min-woong;Cho, Seong-ik;Lee, Nam-ho;Jeong, Sang-hun;Kim, Sung-mi
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.10
    • /
    • pp.1927-1934
    • /
    • 2016
  • In this paper, we proposed a I-gate n-MOSFET (n-type Metal Oxide Semiconductors Field Effect Transistor) structure in order to mitigate a radiation-induced leakage current path in an isolation oxide interface of a silicon-based standard n-MOSFET. The proposed I-gate n-MOSFET structure was designed by using a layout modification technology in the standard 0.18um CMOS (Complementary Metal Oxide Semiconductor) process, this structure supplements the structural drawbacks of conventional radiation-tolerant electronic device using layout modification technology such as an ELT (Enclosed Layout Transistor) and a DGA (Dummy Gate-Assisted) n-MOSFET. Thus, in comparison with the conventional structures, it can ensure expandability of a circuit design in a semiconductor-chip fabrication. Also for verification of a radiation-tolerant characteristic, we carried out M&S (Modeling and Simulation) using TCAD 3D (Technology Computer Aided Design 3-dimension) tool. As a results, we had confirmed the radiation-tolerant characteristic of the I-gate n-MOSFET structure.

A Study of Process factors on the Recycling of Reactive Metal Scraps in Plasma Arc Remelting (Plasma Arc Remelting에서 활성 금속 Scrap 재활용에 미치는 공정인자의 연구)

  • Jung, Jae-Young;Sohn, Ho-Sang
    • Resources Recycling
    • /
    • v.26 no.6
    • /
    • pp.3-9
    • /
    • 2017
  • In this study, plasma arc remelting behaviors according to arc current, arc voltage, and types of plasma gas were investigated using Kroll processed Ti sponges as anode. In the discharge pressure range of vacuum pump ($200{\sim}300kgf/cm^2$), the arc voltage did not vary greatly with the increase of discharge pressure at a given arc length. This means that the pressure in the vacuum chamber during operation hardly changes and the atmospheric pressure maintains. Under various conditions of arc currents (700~900A), the arc voltage slightly increased with arc current. The effects of anode materials and operational variables on the arc length-arc voltage relationship were compared with the results in previous studies. When the atmospheric gas changed from argon to helium, double effect of improvement on the output of the steady state was observed. The increase of output in the plasma arc device was accompanied by an increase in the melting rate of the Ti sponge and the quality of the ingot surface was also improved. The plasma arc remelting of the new scrap titanium and the old scrap zirconium alloy could result in the fabrication of an ingot with high surface quality.

Design of a CMOS Tx RF/IF Single Chip for PCS Band Applications (PCS 대역 송신용 CMOS RF/IF 단일 칩 설계)

  • Moon, Yo-Sup;Kwon, Duck-Ki;Kim, Keo-Sung;Park, Jong-Tae;Yu, Chong-Gun
    • Journal of IKEEE
    • /
    • v.7 no.2 s.13
    • /
    • pp.236-244
    • /
    • 2003
  • In this paper, RF and IF circuits for mobile terminals which have usually been implemented using expensive BiCMOS processes are designed using CMOS circuits, and a Tx CMOS RF/IF single chip for PCS applications is designed. The designed circuit consists of an IF block including an IF PLL frequency synthesizer, an IF mixer, and a VGA and an RF block including a SSB RF mixer and a driver amplifier, and performs all transmit signal processing functions required between digital baseband and the power amplifier. The phase noise level of the designed IF PLL frequency synthesizer is -114dBc/Hz@100kHz and the lock time is less than $300{\mu}s$. It consumes 5.3mA from a 3V power supply. The conversion gain and OIP3 of the IF mixer block are 3.6dB and -11.3dBm. It consumes 5.3mA. The 3dB frequencies of the VGA are greater than 250MHz for all gain settings. The designed VGA consumes 10mA. The designed RF block exhibits a gain of 14.93dB and an OIP3 of 6.97dBm. The image and carrier suppressions are 35dBc and 31dBc, respectively. It consumes 63.4mA. The designed circuits are under fabrication using a $0.35{\mu}m$ CMOS process. The designed entire chip consumes 84mA from a 3V supply, and its area is $1.6㎜{\times}3.5㎜$.

  • PDF

Performance of CWDM Fabricated by the PLC-AWG Technology (평판형 AWG 기술을 이용한 광대역 파장다중화/역다중화 소자의 제작 및 특성)

  • Moon, H.M.;Kwak, S.C.;Hong, J.Y.;Lee, K.H.;Kim, D.H.;Kim, J.J.;Choi, S.Y.;Lee, J.G.;Lee, J.H.;Lim, K.G.;Kim, J.B.
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.3
    • /
    • pp.185-189
    • /
    • 2007
  • A novel technology for CWDM (Coarse Wavelength Division Multiplexer) utilizing a PLC (Planar Lightwave Circuit)-AWG (Arrayed Waveguide Grating) fabrication process is proposed. BPM (Beam Propagation Method) Simulation results on the employed parabolic-horn-type input slab waveguide of AWG and the performance of the 20 nm-channel spacing CWDM with flattened passband are presented. Waveguides of $0.75{\triangle}%$ have been used in this experiment and the insertion loss at the peak wavelength is 3.5 dB for a Gaussian spectrum and is 4.8 dB for a flat-top spectrum. The bandwidth at 3 dB is better than 10 nm and 13 nm for Gaussian and flat-top spectra, respectively.

Construction of a Silver(I) Ion-Selective Electrode Using Amine Phenol Ligand as Carrier and the Selective Determination of Silver in Actual Samples (수송체로서 아민페놀을 이용한 은(I)이온-선택 전극의 제조와 실제 샘플에서 은의 선택적 측정)

  • Xu, Wen-Ju;Chai, Ya-Qin;Yuan, Ruo
    • Journal of the Korean Chemical Society
    • /
    • v.55 no.1
    • /
    • pp.63-69
    • /
    • 2011
  • This work discusses the fabrication, development and potential response behaviors of $Ag^+$ ion-selective electrodes ($Ag^+$-ISE) based on N,N'-bis(2-hydroxybenzyl)-1,3-diaminopropane (L1) and N,N'-bis(2-hydroxybenzyl)-2,2-dimethyl-1,3-diaminopropane (L2) as carriers. The observations indicated that the resulting electrode based on L1 toward $Ag^+$ showed stable near-Nernst slope approaching 58.7 mV/dec and the optimum potential response characteristics in a linear range at least five orders of magnitude with a detection limit of $1.0{\times}10^{-6}M$. The proposed electrode displayed the preferential selectivity to $Ag^+$ against other tested cations. The excellent potential analytical characteristics could lead to the successful applications of silver assay in significant real samples, indicating that the proposed $Ag^+$-ISE showed a significant advancement of measurement capabilities. But for the electrode based on L2, the poor potential response characteristics were observed in total experiment process.

Development of 3-Dimensional Rebar Detail Design and Placing Drawing System (3차원 배근설계 및 배근시공도 작성 자동화 시스템 개발)

  • Choi, Hyun-Chul;Lee, Yunjae;Lee, Si Eun;Kim, Chee Kyeong
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.27 no.4
    • /
    • pp.289-296
    • /
    • 2014
  • The rebar detailing is an important work influencing the final performance and quality of RC structures. But it is one of the most irrational and illogical activity in construction site. Many groups of workers, including main contractors, structural engineers, shop drawers, rebar fabricators, and etc., participate in this activity. A loosely-organized process for this activity is apt to produce a big amount of rebar loss or even degraded structures. A 3-dimensional rebar auto-placing system, called as Rebar Hub, has been designed and implemented in this research. Rebar Hub provides a totally integrated service from 3D structural modeling of buildings to rebar auto-placing considering anchorage, splice, and the length of ordered rebar. In addition, Rebar Hub can recognize the 2D drawing CAD files and then build 3D structural models which are used for the start point of 3D rebar auto-placing. After rebar auto-placing, each members of the 3D structural model have rebar information belonging to them. It means that the rebar information can be used for the afterward works such as quantity-survey, manufacturing and fabrication of rebars. Rebar Hub is showing outstanding performance while applying to practical projects. It has almost five times productivity and reduces the rebar loss up to 3~8% of the initially-surveyed amount of rebar.

Fabrication of suction denture by using the individual tray duplicated an existing denture through scan and milling process: A case report (스캔 및 밀링을 통해 기존 의치를 복제한 개인트레이를 이용한 흡착식 의치 제작 증례)

  • Park, Minhyuk;Kee, Wonjin;Yang, Hongso;Park, Sang-Won;Yun, Kwi-Dug;Park, Chan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.3
    • /
    • pp.221-227
    • /
    • 2020
  • In the case of complete edentulous patients, as the mandibular alveolar bone absorption progresses, the maintenance and stability of the existing dentures, which had satisfactory functions in the past, are deteriorated. Despite of the need to fabricate new dentures, they often hesitate due to physical burdens on the duration and intensity of future treatment progress due to the effects of aging and systemic diseases. In the case of these completely edentulous patients, it is necessary to consider the treatment goals that can reduce the number of visits and the adaptation period for new dentures before starting the treatment. This case is a case of producing complete dentures of elderly patients with deteriorated physical ability. In addition to producing suction dentures through preliminary and definitive closed mouth functional impression suggested by Sato, CAD / CAM technique was used to transfer occlusal functional information of existing dentures to facilitate adaptation to new dentures.