• 제목/요약/키워드: Fabricated report

검색결과 487건 처리시간 0.023초

특수모멘트골조 상세를 갖는 건식 프리캐스트 콘크리트 보-기둥 접합부의 내진성능평가 (Seismic Performance Evaluation of Dry Precast Concrete Beam-Column Connections with Special Moment Frame Details)

  • 김선훈;이득행;김용겸;이상원;여운용;박정은
    • 한국지진공학회논문집
    • /
    • 제27권5호
    • /
    • pp.203-211
    • /
    • 2023
  • For fast-built and safe precast concrete (PC) construction, the dry mechanical splicing method is a critical technique that enables a self-sustaining system (SSS) during construction with no temporary support and minimizes onsite jobs. However, due to limited experimental evidence, traditional wet splicing methods are still dominantly adopted in the domestic precast industry. For PC beam-column connections, the current design code requires achieving emulative connection performances and corresponding structural integrity to be comparable with typical reinforced concrete (RC) systems with monolithic connections. To this end, this study conducted the standard material tests on mechanical splices to check their satisfactory performance as the Type 2 mechanical splice specified in the ACI 318 code. Two PC beam-column connection specimens with dry mechanical splices and an RC control specimen as the special moment frame were subsequently fabricated and tested under lateral reversed cyclic loadings. Test results showed that the seismic performances of all the PC specimens were fully comparable to the RC specimen in terms of strength, stiffness, energy dissipation, drift capacity, and failure mode, and their hysteresis responses showed a mitigated pinching effect compared to the control RC specimen. The seismic performances of the PC and RC specimens were evaluated quantitatively based on the ACI 374 report, and it appeared that all the test specimens fully satisfied the seismic performance criteria as a code-compliant special moment frame system.

하악 부분 무치악 환자에서 Milled-bar와 ADD-TOC 부착 장치를 이용한 탈착 가능한 지르코니아 보철물 수복 증례 (Detachable zirconia prosthesis using Milled bar and ADD-TOC attachment in partial edentulous mandible: A case report)

  • 손민성;허중보
    • 대한치과보철학회지
    • /
    • 제61권1호
    • /
    • pp.90-99
    • /
    • 2023
  • 임플란트 피개의치는 골 흡수가 심한 완전 무치악 또는 부분 무치악 환자의 구강 기능 회복을 위한 치료 방법으로 널리 사용되고 있다. Milled bar를 이용한 임플란트 피개의치의 경우 bar가 임플란트 고정체를 연결 고정하므로 기계적으로 유리하며, bar에 추가적으로 부착 장치를 적용하면 임플란트에 가해지는 응력을 분산시킬 수 있다는 이점이 있다. 본 증례에서는 4개의 임플란트를 사용하여 임플란트 피개의치를 사용하던 환자가 의치의 반복적인 파절과 유지력의 약화로 인해 새로운 보철물 제작을 원하여 ADD-TOC 부착 장치가 부착된 milled bar와 탈착 가능한 지르코니아 보철물을 CAD-CAM 방식으로 제작하였고, 이를 통해 기능적, 심미적으로 만족할 만한 결과를 얻었다.

동적 교합을 나타내는 가상 환자의 형성을 통한 심미적인 전치부 보철 수복 증례 (Using dental virtual patients with dynamic occlusion in esthetic restoration of anterior teeth: case reports)

  • 구필준;최유성;이종혁;하승룡
    • 대한치과보철학회지
    • /
    • 제61권4호
    • /
    • pp.328-343
    • /
    • 2023
  • 최근 삼차원적 안면 스캔 (facial scan) 및 악운동 (jaw motion) 등의 데이터를 통합하여 동적 교합을 나타내는 가상 환자를 형성함으로써 심미적인 전치부 고정성 보철물을 제작하는 방법이 소개되고 있다. 이를 통해 진단과정에서 환자와의 원활한 소통이 가능하며, 심미적인 보철 치료의 예지성을 높일 수 있고, 교합조정의 가능성을 낮출 수 있다. 본 증례에서는 상악 전치부 심미 보철 수복이 필요한 환자에서 구강 스캔 데이터와 삼차원 (3D) 안면 스캔데이터, 환자의 악운동 기록을 computer-aided design (CAD) 소프트웨어 상에서 통합하여 동적 교합을 나타내는 가상 환자를 형성하였다. 이를 통해 치료의 결과를 시뮬레이션하고 심미적인 상악 전치부 고정성 보철물을 제작 및 수복하였다. 또한, 안정적인 교합관계를 회복하고 적절한 전방유도가 형성되었는지 확인하기 위하여 각각 치료 단계별로 환자의 교합을 비교 평가하였으며 심미적, 기능적으로 만족스러운 결과를 보였기에 이를 보고하는 바이다.

안면 스캔을 이용한 3회 내원 디지털 총의치 수복: 증례보고 (3-step digital complete denture restoration using facialscan: a case report)

  • 권영석;홍성진;백장현;배아란;김형섭;권긍록;노관태
    • 대한치과보철학회지
    • /
    • 제61권4호
    • /
    • pp.356-366
    • /
    • 2023
  • 의치의 지지, 유지, 안정은 무치악 환자의 총의치 수복 시 중요한 요소들이다. 최근 디지털 치의학의 발전으로 전통적인 치료방식을 대체하기 위한 시도들이 계속되고 있으며, 환자의 내원 횟수를 줄이고 높은 수준의 디지털 의치를 제작하려는 시도들이 계속되고 있다. 본 증례에서는 새롭게 고안된 고딕 아치 기록을 통한 중심위 채득이 가능한 tray와 안면 스캔을 이용하여 디지털 총의치로 수복하였다. 전통적인 총의치 수복방식을 대체하여 환자의 내원횟수를 줄이고 만족할만한 의치의 지지, 유지, 안정 및 심미적인 결과를 얻었기에 이를 보고하는 바이다.

안면스캔 데이터와 임시의치를 복제한 개인 트레이를 활용하여 CAD/CAM을 통한 monolithic disc로 제작한 총의치 수복: 증례 보고 (Fabrication of complete dentures made with monolithic discs through CAD/CAM using facial scan data and individual tray duplicating temporary denture: a case report)

  • 김주현;신수연
    • 구강회복응용과학지
    • /
    • 제39권3호
    • /
    • pp.158-167
    • /
    • 2023
  • 최근 치의학 분야에서 디지털 기술이 발달함에 따라 computer-aided design-computer-aided manufacturing (CAD/CAM)을 이용한 의치 제작 진료 단계의 변화를 가져왔다. CAD/CAM 기술을 이용한 의치 제작 방식은 제작기간과 내원 간격의 단축으로 임상적인 효율성과 편리함을 제공함과 동시에 기공을 단순화하여 오류 발생을 감소시켰다. 본 증례는 복잡한 병력과 신체적 장애를 가진 환자에게 기존의 임시의치를 디지털 방식으로 복제 및 출력하여 개인 트레이로 활용하였고, 부가중합형 실리콘 인상재로 채득한 최종 인상체에는 수직고경과 중심위, 상악 전치부의 각도 및 길이에 대한 정보가 포함되어 있으며 이를 통해 제작 기간과 내원 간격을 단축하여 환자의 만족도를 높일 수 있었다. 최종 의치는 밀링 방식 및 monolithic disc를 이용하여 제작하였고, 적절한 안정과 유지, 지지를 보여 기능적, 심미적으로 만족스러운 결과를 얻을 수 있었다.

불안정한 하악위를 가진 무치악 환자에서 치료의치와 디지털 기술을 이용한 치료 증례 (Using treatment denture and digital technology in patient with unstable mandibular movement: a case report)

  • 오은지;장우형;박찬;윤귀덕;임현필;박상원
    • 구강회복응용과학지
    • /
    • 제39권3호
    • /
    • pp.168-175
    • /
    • 2023
  • 부적합한 보철물을 장기간 사용하면 습관성 폐구위나 불규칙한 하악 운동을 보이는 경우가 빈발하다. 이러한 환자는 고정된 중심 위로 유도하는 것이 어려우므로 치료의치를 이용하여 근육과 TMJ를 안정 시키고 치료위로써 악간 관계 채득을 해야한다. 디지털 방식을 이용한 의치 제작은 전통적인 방식과 비교하여 치아 배열이 까다로운 증례에서 안정화된 치아 배열을 재현하여 수작업에 의한 오차를 최소로 하고, 의치 제작 시간을 감소 시킬 수 있다는 장점이 있다. 따라서 본 증례에서는 치료의치로 안정된 치료위, 수직고경 및 구순 지지도를 디지털 방식으로 이행하여 최종 의치를 제작하였으며, 만족스러운 결과를 얻었기에 이를 보고하는 바이다.

Induction of Peptide-specific CTL Activity and Inhibition of Tumor Growth Following Immunization with Nanoparticles Coated with Tumor Peptide-MHC-I Complexes

  • Sang-Hyun Kim;Ha-Eun Park;Seong-Un Jeong;Jun-Hyeok Moon;Young-Ran Lee;Jeong-Ki Kim;Hyunseok Kong;Chan-Su Park;Chong-Kil Lee
    • IMMUNE NETWORK
    • /
    • 제21권6호
    • /
    • pp.44.1-44.15
    • /
    • 2021
  • Tumor peptides associated with MHC class I molecules or their synthetic variants have attracted great attention for their potential use as vaccines to induce tumor-specific CTLs. However, the outcome of clinical trials of peptide-based tumor vaccines has been disappointing. There are various reasons for this lack of success, such as difficulties in delivering the peptides specifically to professional Ag-presenting cells, short peptide half-life in vivo, and limited peptide immunogenicity. We report here a novel peptide vaccination strategy that efficiently induces peptide-specific CTLs. Nanoparticles (NPs) were fabricated from a biodegradable polymer, poly(D,L-lactic-co-glycolic acid), attached to H-2Kb molecules, and then the natural peptide epitopes associated with the H-2Kb molecules were exchanged with a model tumor peptide, SIINFEKL (OVA257-268). These NPs were efficiently phagocytosed by immature dendritic cells (DCs), inducing DC maturation and activation. In addition, the DCs that phagocytosed SIINFEKL-pulsed NPs potently activated SIINFEKL-H2Kb complex-specific CD8+ T cells via cross-presentation of SIINFEKL. In vivo studies showed that intravenous administration of SIINFEKL-pulsed NPs effectively generated SIINFEKL-specific CD8+ T cells in both normal and tumor-bearing mice. Furthermore, intravenous administration of SIINFEKL-pulsed NPs into EG7.OVA tumor-bearing mice almost completely inhibited the tumor growth. These results demonstrate that vaccination with polymeric NPs coated with tumor peptide-MHC-I complexes is a novel strategy for efficient induction of tumor-specific CTLs.

회전삽입로 국소의치를 이용한 심미적 상악 전치부 수복 증례 (An Esthetic Restoration of the Missing Maxillary Anterior Teeth with the Rotational Path RPD: A Case Report)

  • 이지혜;임소민;정혜은;박찬진;조리라;김대곤
    • 구강회복응용과학지
    • /
    • 제27권2호
    • /
    • pp.209-222
    • /
    • 2011
  • 상실된 상악 전치부는 고정성 보철물이나 가철성 보철물 또는 임플란트 보철 등 다양한 방법을 통하여 수복할 수 있다. 이 중 적절하게 제작된 회전삽입로 국소의치는 경제적, 해부학적 한계를 가진 환자에서 기능적, 심미적으로 우수한 결과를 보일 수 있다. 회전삽입로 국소의치는 일반적 국소의치의 일직선 삽입로와는 달리 국소의치의 한 쪽 유지장치부가 먼저 장착된 뒤 회전하면서 반대쪽의 유지부가 삽입되어 의치가 안착된다. 이 때 언더컷 속에 위치하는 견고한 부연결장치에서 유지력을 획득하고 회전삽입로와 평행하게 긴 수로형 혹은 구미형(dovetail) 레스트 시트에서 지지 및 파지를 얻으므로 일반적인 가요성 유지암 및 파지암을 생략할 수 있어 심미적으로 우수하고 위생 관리에도 유리하다. 그러나 회전삽입로 국소의치에서 한번 제작된 견고한 유지부는 정교한 조절이 불가능해 상대적으로 기공작업이 어렵고 정밀한 보철물 디자인이 필요하므로 임상적인 성공을 위해서는 회전삽입로 국소의치의 원리에 대한 깊은 이해가 필요하다. 이번 증례보고는 회전삽입로 국소의치를 장착한 후 장기적인 유지관리의 어려움을 겪은 증례를 소개하고 이를 예방할 수 있는 이론적, 기공적 주의사항을 보고하고자 한다.

Carbon nanotube field emission display

  • Chil, Won-Bong;Kim, Jong-Min
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제12권7호
    • /
    • pp.7-11
    • /
    • 1999
  • Fully sealed field emission display in size of 4.5 inch has been fabricated using single-wall carbon nanotubes-organic vehicle com-posite. The fabricated display were fully scalable at low temperature below 415$^{\circ}C$ and CNTs were vertically aligned using paste squeeze and surface rubbing techniques. The turn-on fields of 1V/${\mu}{\textrm}{m}$ and field emis-sion current of 1.5mA at 3V/${\mu}{\textrm}{m}$ (J=90${\mu}{\textrm}{m}$/$\textrm{cm}^2$)were observed. Brightness of 1800cd/$m^2$ at 3.7V/${\mu}{\textrm}{m}$ was observed on the entire area of 4.5-inch panel from the green phosphor-ITO glass. The fluctuation of the current was found to be about 7% over a 4.5-inch cath-ode area. This reliable result enables us to produce large area full-color flat panel dis-play in the near future. Carbon nanotubes (CNTs) have attracted much attention because of their unique elec-trical properties and their potential applica-tions [1, 2]. Large aspect ratio of CNTs together with high chemical stability. ther-mal conductivity, and high mechanical strength are advantageous for applications to the field emitter [3]. Several results have been reported on the field emissions from multi-walled nanotubes (MWNTs) and single-walled nanotubes (SWNTs) grown from arc discharge [4, 5]. De Heer et al. have reported the field emission from nan-otubes aligned by the suspension-filtering method. This approach is too difficult to be fully adopted in integration process. Recently, there have been efforts to make applications to field emission devices using nanotubes. Saito et al. demonstrated a car-bon nanotube-based lamp, which was oper-ated at high voltage (10KV) [8]. Aproto-type diode structure was tested by the size of 100mm $\times$ 10mm in vacuum chamber [9]. the difficulties arise from the arrangement of vertically aligned nanotubes after the growth. Recently vertically aligned carbon nanotubes have been synthesized using plasma-enhanced chemical vapor deposition(CVD) [6, 7]. Yet, control of a large area synthesis is still not easily accessible with such approaches. Here we report integra-tion processes of fully sealed 4.5-inch CNT-field emission displays (FEDs). Low turn-on voltage with high brightness, and stabili-ty clearly demonstrate the potential applica-bility of carbon nanotubes to full color dis-plays in near future. For flat panel display in a large area, car-bon nanotubes-based field emitters were fabricated by using nanotubes-organic vehi-cles. The purified SWNTs, which were syn-thesized by dc arc discharge, were dispersed in iso propyl alcohol, and then mixed with on organic binder. The paste of well-dis-persed carbon nanotubes was squeezed onto the metal-patterned sodalime glass throuhg the metal mesh of 20${\mu}{\textrm}{m}$ in size and subse-quently heat-treated in order to remove the organic binder. The insulating spacers in thickness of 200${\mu}{\textrm}{m}$ are inserted between the lower and upper glasses. The Y\ulcornerO\ulcornerS:Eu, ZnS:Cu, Al, and ZnS:Ag, Cl, phosphors are electrically deposited on the upper glass for red, green, and blue colors, respectively. The typical sizes of each phosphor are 2~3 micron. The assembled structure was sealed in an atmosphere of highly purified Ar gas by means of a glass frit. The display plate was evacuated down to the pressure level of 1$\times$10\ulcorner Torr. Three non-evaporable getters of Ti-Zr-V-Fe were activated during the final heat-exhausting procedure. Finally, the active area of 4.5-inch panel with fully sealed carbon nanotubes was pro-duced. Emission currents were character-ized by the DC-mode and pulse-modulating mode at the voltage up to 800 volts. The brightness of field emission was measured by the Luminance calorimeter (BM-7, Topcon).

  • PDF

과도한 치관높이 공간을 가진 환자에서 유지관리를 고려한 임플란트 수복증례 (Implant restoration considering maintenance for a patient with excessive crown height space)

  • 마주리;양홍서;박상원;임현필;윤귀덕;방몽숙
    • 대한치과보철학회지
    • /
    • 제51권2호
    • /
    • pp.107-112
    • /
    • 2013
  • 치관높이 공간이 과도할 경우 임플란트 몸체 혹은 구성물의 실패와 같은 고정성 보철물의 생역학적 합병증이 증가하며 치관 높이 공간이 12 mm 이상으로 과도한 경우는 고정성 보철물 선택에 유의하여야 한다. 고정성 보철물을 제작 시 치아들이 길어지므로 심미적 부위에서는 치은 색조를 띠는 재료를 사용해야 할 필요가 있다. 이러한 경우, 유지와 위생 관리가 적절하지 못하게 형성된 고정성 보철물은 음식물, 치태, 치석을 정체시키고 염증과 감염이 발생될 수 있으며 만성 염증과 감염으로 인해 외과적인 개선이 필요할 수 있다. 본 증례에서, 과도한 치관높이 공간을 가진 환자에게 발음 및 심미성을 고려하여 보철물 제작 후 보철물 주위의 치은 염증 및 부종이 발생하였으며, 그 원인이 구강위생을 어렵게 하는 보철물의 디자인으로 판단되어 치간공극을 충분히 형성한 임시 보철물을 장착 후 2개월 동안의 관찰 기간을 거치며 특이할 만한 이상 소견이 없음을 확인하였고 자가 위생 관리가 용이한 디자인으로 지르코니아 하부구조에 도재를 축성한 고정성 보철물로 구강회복을 시행하였으며, 일련의 치료과정을 통하여 부적절한 연조직 반응이 관찰 되지 않고 기능적인 면에서 만족스러운 결과를 얻을 수 있었다.