• Title/Summary/Keyword: Fabricated report

Search Result 487, Processing Time 0.026 seconds

Full mouth rehabilitation using transfer coping pick up impression in a patient with severe bleeding: A case report (출혈이 심한 환자에서 개별치아 인상채득후 트랜스퍼 코핑 픽업 인상법을 이용한 전악수복증례)

  • Ha, Seung-Ryong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.1
    • /
    • pp.134-145
    • /
    • 2021
  • In the case of excessively worn dentition, there is often insufficient space for the prosthesis, and if physiologically acceptable, the prosthesis can be fabricated by increasing the vertical dimension of occlusion. Various methods have been introduced to determine the vertical dimension of occlusion. Clinicians have to choose a method that can comfort the patient among several methods. A removable appliance can be used as a reversible method to ensure that the determined vertical dimension of occlusion does not cause physiological problems. When making impressions of many teeth, it is often difficult to make accurate impressions at once. In this case, after making an accurate impression of the individual teeth, a transfer coping was made and a pickup impression was taken in the oral cavity to create a master cast. In this case, a fixed partial denture was fabricated and full mouth rehabilitation was performed by increasing the vertical dimension of occlusion in a patient with excessively worn dentition and lack of space for restoration. As a result of follow-up of the patient for 7 years, satisfactory results were obtained both esthetically and functionally.

Long-Term Shelf Lifetime of Polymer:Nonfullerene Solar Cells Stored under Dark and Indoor Light Environment

  • Lee, Sooyong;Kim, Hwajeong;Kim, Youngkyoo
    • Current Photovoltaic Research
    • /
    • v.8 no.4
    • /
    • pp.107-113
    • /
    • 2020
  • Here we report the long-term stability of polymer:nonfullerene solar cells which were stored under dark and indoor light condition. The polymer:nonfullerene solar cells were fabricated using bulk heterojunction (BHJ) layers of poly[(2,6-(4,8-bis(5-(2-ethylhexyl) thiophen-2-yl)-benzo[1,2-b:4,5-b']dithiophene))-alt-(5,5-(1',3'-di-2-thienyl-5',7-bis(2-ethylhexyl)benzo[1',2'-c:4',5'-c']dithiophene-4,8-dione))] (PBDB-T) and 3,9-bis(6-methyl-2-methylene-(3-(1,1-dicyanomethylene)-indanone))-5,5,11,11-tetrakis(4-hexylphenyl)-dithieno[2,3-d:2',3-d']-s-indaceno[1,2-b:5,6-b']dithiophene (IT-M). To investigate their long-term stability, the PBDB-T:IT-M solar cells were stored in an argon-filled glove box. One set of the fabricated solar cells was completely covered with an aluminum foil to prevent any effect of light, whereas another set was exposed to indoor light. The solar cells were subjected to a regular performance measurement for 40 weeks. Results revealed that the PBDB-T:IT-M solar cells underwent a gradual decay in performance irrespective of the storage condition. However, the PBDB-T:IT-M solar cells stored under indoor light condition exhibited relatively lower power conversion efficiency (PCE) than those stored under the dark. The inferior stability of the solar cells under indoor light was explained by the noticeably changed optical absorption spectra and dark spot generation, indicative of degradations in the BHJ layers.

Electrical and Optical Properties of Fluorine-Doped Tin Oxide Films Fabricated at Different Substrate Rotating Speeds during Ultrasonic Spray Pyrolysis Deposition (초음파 분무 열분해 증착 중 기판 회전 속도에 따른 플루오린 도핑 된 주석산화물 막의 전기적 및 광학적 특성)

  • Ki-Won Lee;yeong-Hun Jo;Hyo-Jin Ahn
    • Korean Journal of Materials Research
    • /
    • v.34 no.1
    • /
    • pp.55-62
    • /
    • 2024
  • Fluorine-doped tin oxide (FTO) has been used as a representative transparent conductive oxide (TCO) in various optoelectronic applications, including light emitting diodes, solar cells, photo-detectors, and electrochromic devices. The FTO plays an important role in providing electron transfer between active layers and external circuits while maintaining high transmittance in the devices. Herein, we report the effects of substrate rotation speed on the electrical and optical properties of FTO films during ultrasonic spray pyrolysis deposition (USPD). The substrate rotation speeds were adjusted to 2, 6, 10, and 14 rpm. As the substrate rotation speed increased from 2 to 14 rpm, the FTO films exhibited different film morphologies, including crystallite size, surface roughness, crystal texture, and film thickness. This FTO film engineering can be attributed to the variable nucleation and growth behaviors of FTO crystallites according to substrate rotation speeds during USPD. Among the FTO films with different substrate rotation speeds, the FTO film fabricated at 6 rpm showed the best optimized TCO characteristics when considering both electrical (sheet resistance of 13.73 Ω/□) and optical (average transmittance of 86.76 % at 400~700 nm) properties with a figure of merit (0.018 Ω-1).

Fabrication of Gold Nanostructures Using Electrochemical Deposition Integrated with Solution Process (용액 공정을 접목한 전기화학 증착 기법을 활용한 금 나노 구조체 제작)

  • Jihee Kim;Donghyeon Kim;Mijeong Kang
    • Journal of the Korean Electrochemical Society
    • /
    • v.27 no.3
    • /
    • pp.81-87
    • /
    • 2024
  • Nanomaterial electrodes are used to improve the analytical performances of electrochemical measurements in biological and chemical field. Frequently used methods for fabricating metal nanostructures are solution processing and electrodeposition. In the solution process, it is possible to control the characteristics (e.g., direction) of metal growth by using capping agents, thereby fabricating nanoparticles of specific structures. In the electrodeposition, the electrode surface and the deposited metal atoms are in direct contact. Each process has its own limitation as well, and many studies are conducted to overcome such limitation. In this paper, we report an integration of the two fabrication methods and the characteristics, such as structural and electrochemical properties, of the fabricated electrodes. Lastly, we discuss the possibility of using the fabricated nanostructured electrode as a sensor.

Prosthetic rehabilitation of partially edentulous patient after maxillectomy: A case report (상악골 부분절제술 시행한 부분 무치악 환자에서 폐쇄 장치를 이용한 보철 수복 증례)

  • Heo, Kyung-Hoi;Lim, Young-Jun;Kim, Myung-Joo;Kwon, Ho-Beom
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.2
    • /
    • pp.167-171
    • /
    • 2016
  • Patients undergone partial maxillectomy experience post-operative masticatory, phonetic, and swallowing difficulties. They also encounter social and psychological challenges due to changes in their facial appearances. Thus, functional and esthetic recovery through maxillofacial prosthesis becomes significant for these patients. The objective of an appropriate obturator is to restore palate and improve phonetic and swallowing ability by separating the oral cavity, nasal cavity, maxillary sinus, and nasopharynx. In this case report, an obturator was fabricated for a patient who had partial resection from the maxillary posterior region to the pharynx due to squamous cell carcinoma. The purpose of this case study is to describe the results because the patient was successfully improved both functionally and esthetically.

Rehabilitation of edentulous maxilla with implant-supported milled bar overdenture using CAD/CAM customized abutment: A case report (CAD/CAM 맞춤형 지대주를 이용한 milled-bar 피개의치 증례)

  • Ji, Woon;Chang, Jae-Seung;Kwon, Joo-Hyun;Kim, Sunjai
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.2
    • /
    • pp.146-151
    • /
    • 2016
  • In patients with fully edentulous maxilla, fabrication of implant-supported overdenture can be a viable treatment option, when a minimum of six implants were strategically placed. Among several attachment systems used for implant-supported overdentures, milled-bars prevent rotational movement of denture, thus showing great stability, and have the advantage of splinting multiple implants with each other. In this case report, a milled-bar supported overdenture was fabricated for a patient suffering from condition of fully edentulous maxilla with severe ridge resorption in the anterior residual ridge. Seven implants composed of three different systems were effectively utilized by CAD/CAM customized abutment and cement-retained milled bar.

Fabrication of computer-aided design/computer-aided manufacturing complete denture and conventional complete denture: case report (CAD/CAM system과 전통적인 방법을 이용한 총의치 동시 제작 증례)

  • Kim, Mi-Jin;Kim, Kang-Ho;Yeo, Dong-Heon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.2
    • /
    • pp.141-148
    • /
    • 2016
  • Recently computer-aided technology has been widely used in dentistry. DENTCA$^{TM}$ CAD/CAM denture system (DENTCA Inc.), one of CAD/CAM systems for fabricating complete denture, tries to collect and store all of a patient's information at the first visit. This system aims to deliver denture at the second visit through utilizing the CAD/CAM software to access the stored data for designing the 3D denture model. The 3 dimensional (3D) denture will then be fabricated with 3D printer. Many case reports have evaluated clinical application of CAD/CAM system for fabricating complete dentures. This case report is about fabricating of complete dentures using DENTCA system and conventional method in same patient. With two cases, usefulness and limitation of DENTCA system could be evaluated.

Manometer Scale Mark Formation using Thermal Reaction For Storage Application (열 반응을 이용한 나노사이즈 마크형성)

  • Jung, Moon-Il;Kim, Joo-Ho;Hwang, In-Oh;Kim, Hyun-Ki;Bae, Jae-Cheol;Park, In-Sik;Kuwahara, Masashi;Tominaga, Junji
    • Transactions of the Society of Information Storage Systems
    • /
    • v.1 no.2
    • /
    • pp.127-131
    • /
    • 2005
  • We report a nanometer scale mark formation using a $PtO_x$ thin film or a TbFeCo rare-earth transition metal film and the mechanism. The multi-layer samples($ZnS-SiO_2/PtOx/ZNS-SiO_2,\;ZnS-SiO_2/TbFeCo/ZnS-SiO_2$) were prepared with a magnetron sputtering method on a polycarbonate or a glass substrate. By laser irradiation of approximately a few nanoseconds, nanometer scale marks were fabricated. During the fabrication process, the thin films were thermally reacted or inter-diffused during the laser irradiation. 75 nm bubble marks in the PtOx multi-layer sample by an approximately 4-ns laser irradiation. Inside the bubble mark, Pt particles with a few nanometer sizes are distributed. The $50{\sim}100$ nm bubble marks in the TbFeCo multi-layer sample by a few nanosecond laser irradiations. We will report the detail structure of the samples, the bubble mark formation process and the mechanism.

  • PDF

A technique for fabricating abutment replica with hot melt adhesive material to minimize residual cement in implant restoration: a case report (임플란트 보철 합착 시 잔여 시멘트 최소화를 위해 열가소성 접착제를 이용한 복제 지대주 제작 방법: 증례보고)

  • Seo, Chi-Won;Han, A-Reum;Seo, Jae-Min;Lee, Jung-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.3
    • /
    • pp.240-245
    • /
    • 2016
  • Removal of excess cement is important to prevent biological complication in cementation of implant restoration with subgingival margin. It can be difficult to completely remove excess cement. Several techniques have been introduced to minimize excess cement using abutment replica. In this case report, a simple method for making abutment replica with hot melt adhesive material in dental office was described. This technique is simple and effective because it can be used for pre-fabricated or custom abutment without additional laboratory procedure. In addition, it can minimize excess cement after cementation of implant restoration.

Fixed prostheses fabricated by direct metal laser sintering system: case report (Direct metal laser sintering 방식을 이용하여 제작한 다양한 고정성 보철물 수복 증례)

  • Baek, Ju-Won;Shin, Soo-Yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.3
    • /
    • pp.246-254
    • /
    • 2016
  • Nowadays, 3 dimentional (3D) printing, especially Direct Metal Laser Sintering (DMLS) system is used in dentistry. DMLS system has recently been introduced for fabrication metal framework for metal ceramic crowns to overcome the disadvantages of the casting method and computer aided design/computer aided manufacturing (CAD/CAM) milling system. DMLS system uses a high-temperature laser beam to selectively heat a substructure metal powder based on the CAD data with the framework design. A thin layer of the beamed area becomes fused, and the metal framework is completed by laminating these thin layers. Utilizing DMLS system to fabricate fixed prostheses is expected to achieve free-from shaping without mold and limitations from cutting tools, fabricate prostheses with complex geometry, prevent distortion and fabrication defects that inherent to conventional fabrication methods. The purpose of this case report is to demonstrate various fixed prostheses such as long span fixed prostheses, post to achieve satisfactory results in functional and esthetic aspects.