• Title/Summary/Keyword: FTIR direct-on-filter Method

Search Result 4, Processing Time 0.015 seconds

The evaluation of correction methods and effect of kaolinite on quantitative analysis of quartz in respirable dust by FTIR direct-on-filter method (직접필터법을 이용한 석영 분석시 고령석의 영향 및 보정방법 평가)

  • Phee, Young Gyu
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.19 no.1
    • /
    • pp.1-7
    • /
    • 2009
  • To establish the Fourier-Transform Infra-Red spectrophotometry(FTIR) Direct-On-Filter(DOF) technique as a useful analytical method for quartz in respirable dust samples, an influence of the kaolinite should be corrected. Respirable dust, created in a dust chamber containing the standard material of quartz and kaolinite were collected using a cyclone equipped with a 25 mm, $0.8\;{\mu}m$ pore size DM filter as a collection medium. This study was designed to compare three methods of correction for kaolinite when quantifying the content of quartz, including the least square, the optimum choice and the spectral subtraction methods. The content of quartz in the respirable dust samples was overestimated by 6.2% when mixed with kaolinite(35.5% by weight). The content of quartz containing kaolinite(72.8% by weight) were overestimated by 32%. The spectral subtraction method underestimated the quartz content by 1.5%, while the other two correction methods, the optimum choice and the least square method, overestimated the quartz content by 1.9% to 6.4% and 0.04 to 1.1%, respectively. The results of this study are suggested that, when correcting for effects of kaolinite on quantitative analysis of quartz in respirable dust by FTIR direct-on-filter method, the least square method produce the most unbiased results be compared with those of other correction methods.

The effect of cristobalite on quantitative analysis of quartz in respirable dust by FTIR direct-on-filter method (직접필터법을 이용하여 호흡성 분진내 석영을 정량분석할 때 크리스토바라이트가 미치는 영향)

  • Phee, Young Gyu;Roh, Young-Man;Kim, Hyun Wook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.17 no.1
    • /
    • pp.21-30
    • /
    • 2007
  • To establish the Fourier-transform infra-red spectrophotometry (FTIR) direct-on-filter(DOF) technique as a useful analytical method for quartz in respirable dust samples, influence of the interference should be corrected. This study was designed to compare three methods of correction for cristobalite when quantifying the content of quartz, including the least square, the optimum choice and the spectral subtraction methods. Respirable dust, created in a dust chamber containing the standard material of quartz, cristobalite was collected using a cyclone equipped with a 25 mm, $0.8{\mu}m$ pore size DM filter as a collection medium. The quartz weights overestimated about 100% when mixed of cristobalite by measure using 799 cm-1 absorption peak of quartz. The quartz weights appeared over estimated by optimum choice, spectral subtraction and least square method in mixtures of 33% cristobalite were 90.3%, 60.1% and about 4.3%, respectively. The least square method have been adopted to correction methods of cristobalite and satisfactory results have been obtained. The results of this study suggest that, when correcting for effect of cristobalite on quantitative analysis of quartz in respirable dust by FTIR direct-on-filter method, the least square method produce the most unbiased results compared with those of other correction methods.

Analysis of Quartz Concentrations by FTIR-DOF and FTIR-Transfer method in Concrete Manufacturing Industries (콘크리트 취급사업장의 공기 중 석영 분석방법 비교)

  • Bae, Hye Jeong;Jung, Jong-Hyeon;Phee, Young Gyu
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.23 no.2
    • /
    • pp.75-83
    • /
    • 2013
  • Objectives: This study was conducted to estimate quartz concentrations in the airborne respirable dust from concrete manufacturing industries and to compare performance of two analytical methods, direct on filter(DOF) and the transfer methods in the Fourier Transform Infrared Spectroscopy(FTIR). Methods: Total 36 area samples were collected from 8 concrete manufacturing industries. Each respirable dust sample was collected by a 25 mm cassette attached to a 10 mm Dorr-Oliver nylon cyclone. The quartz content was estimated using the intensity of the absorption peak of quartz at $799cm^{-1}$ by FTIR. Results: By the comparison of quartz content in respirable dust between the two methods, the results of using DOF method were higher than that of transfer method. And the result of quartz concentrations in respirable dust estimated by DOF method were mostly higher than those by transfer method. Statistically significant difference of quartz concentrations in respirable dust were not found in shakeout, input, loading and transporting processes by two methods. But quartz concentrations in the molding process had the statistically significant difference between DOF and transfer method. Conclusions: The results of the study is suggested that, it be needed to correct the influence of the interferences in order to establish the DOF method when interfering minerals have an effect on quantitative analysis of quartz in respirable dust by the direct on filter method with FTIR.

The Preliminary Study on the Quantitative Analysis of Quarts by Fourier Transform Infrared Spectrophotometric Direct on Filter(FTIR-DOF) Method -Effects of filter materials, inhomogeneity of deposition, and humidity- (Fourier Transform Infrared Spectrophotometric Direct on Filter 방법을 이용한 석영 분석의 기초 연구 - 필터재질, 비균일 침착 및 습도의 영향 -)

  • Phee, Young Gyu;Kim, Hyunwook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.15 no.1
    • /
    • pp.1-7
    • /
    • 2005
  • Although the Fourier Transform Infra-Red spectrophotometric Direct on Filter(FTIR-DOF) method is a useful analytical technique for quantifying quartz content in respirable dust samples, a number of analytical problems must be taken into consideration such as, to name only a few, inhomogeneous deposition of particles, level of environmental humidity, uneven surface of the filter, and interfering minerals in the sample. This study was designed to select the most suitable wavelength and proper filter material for the method, and to investigate effects of humidity and inhomogeneous deposition of particles on the filter. Samples of respirable dust, created in a dust chamber containing standard material of quartz, were collected using a cyclone equipped with a 25mm filter as a collection medium. The results were as follows; 1. Among seven (7) commercially available filters tested for the FTIR-DOF method, the DM 800 filter showed the best analytical performance having the lowest background absorbance bands and no overlapping peaks at 799, 779, and $695cm^{-1}$. 2. The variations of absorbance due to humidity ranged from 1.0% to 3.3% for $799cm^{-1}$, 1.0% to 3.3% for $779cm^{-1}$, and 8.9%~20.9% for $695cm^{-1}$ peaks, respectively. The $699cm^{-1}$ peak was proved to be most vulnerble to environmental humidity for quantitative analysis of quartz. 3. As for effects of inhomogeneous deposition of samples, the highest variation of absorbance of 10.9% ($13.5{\mu}g$) was observed when using the 695cm-1. The variations of absorbance from the other two peaks, 799 and $779cm^{-1}$, ranged from 1.2 to 3.2%, and 1.4 to 4.1%, respectively. Therefore, the $799cm^{-1}$ peak was considered to be most reliable for quantitative analysis of quartz. The results of this study suggest that, for quantitative analysis of quartz in the respirable dust samples, use of the $799cm^{-1}$ peak can minimize the influence of environmental humidity and inhomogeneous deposition of particles on the filter. The FTIR-DOF method, if adopted for routine analysis of quartz in the respirable dust samples, could save sample preparation time and efforts substantially and also could increase analytical throughputs. Since use of the $799cm^{-1}$ peak is prone to be affected by interferences in the sample, further research on minimizing the effects is needed.