• Title/Summary/Keyword: FTA(Failure tree analysis)

Search Result 84, Processing Time 0.027 seconds

Application of Reliability Centered Maintenance for Waterworks after Constructing CMMS (Computerized Maintenance Management System) (유지관리업무 시스템(CMMS) 구축에 따른 수력발전 및 수도설비를 위한 신뢰도 기반 유지보수(RCM) 적용)

  • Lee, Sung-Hoon;Lee, Jong-Bum;Kim, Jeong-Rak
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.424-425
    • /
    • 2008
  • This paper presents application of RCM(Reliability Centered Maintenance) in waterworks system. The reliability-based probability model for predicting the failure probability is established and FTA(Fault Tree Analysis) is proposed to considering RCM. To calculate failure probability, Weibull distribution is usually used due to age related reliability. FTA is an engineering analysis which is using logic symbols. The real historical data of CMMS(Computerized Maintenance Management System) make full use of case study for waterworks system. Consequently, the RCM would be likely to permit utilities to reduce overall costs in maintenance and improve the total benefit.

  • PDF

Analysis of failure rate according to capacitor position of bidirectional converter (양방향 컨버터의 커패시터 위치에 따른 고장률 분석)

  • Kim, Ye-rin;Kang, Feel-soon
    • Journal of IKEEE
    • /
    • v.23 no.1
    • /
    • pp.261-265
    • /
    • 2019
  • We analyze the failure rate change of a conventional bidirectional converter and a modified one which moves an output capacitor towards propulsion battery. We analysis of the circuit structural homogeneity and the difference between both converters, and confirm that the capacitor working voltage is reduced by changing the capacitor position. After obtaining the capacitor failure rate according to voltage stress factor and operating temperature, it is applied to the fault-tree of the bidirectional converter to obtain the overall failure rate of the converter. We analyzes the advantages and disadvantages of design changes by comparing and analyzing the failure rate and mean time between failures (MTBF) according to operating temperature and capacitance value.

Usability Improvement Process of Chatbot System Using FMEA and FTA (FMEA 와 FTA 를 활용한 챗봇 시스템의 사용성 개선 프로세스)

  • Lee, Yeonjae;Song, Jaewoo;Han, Hyuksoo
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2020.11a
    • /
    • pp.1097-1100
    • /
    • 2020
  • 챗봇(Chatbot)은 자연어처리기술 등 인공지능 기술을 기반으로 한 사용자 친화적인 대화 방식 인터페이스를 제공하는 장점이 있어, 금융, 상담, 주문 등 다양한 산업 분야에서 적용되고 있다. 그러나, 챗봇의 응답이 사용자의 정신 모형과 불일치하는 경우, 다음 대화를 이어가는데 어려움을 야기하게 된다. 그러므로, 챗봇의 사용성을 확보하기 위해서는 응답 오류의 제거 또는 완화가 필수적이다. 기존의 챗봇의 사용성 개선과 관련된 연구들은 설문조사와 인터뷰 등 사용성 평가를 통해 상위 수준의 개선 방향만을 제안하고 있다. 따라서, 챗봇 개발 시, 실무자들이 응답 오류의 문제점을 분석하고, 이를 해결하기 위한 구체적인 개선 방안을 제시하는 데 한계가 있었다. 본 논문에서는 FMEA(Failure Modes and Effects Analysis) 기법을 활용해, 응답 오류의 치명도를 파악하고, 치명적인 오류들에 대해서는 FTA(Fault Tree Analysis) 기법을 기반으로 원인 분석을 실시하여 구체적으로 문제를 해결하기 위한 프로세스를 제안한다. 본 프로세스의 효용성을 검증하기 위해 주문 도메인의 챗봇에 적용해 보았다.

Fault Tree Analysis and its Application for Designing High Reliability Electrical System in Underwater Vehicle (수중함 전기 계통의 고 신뢰도 설계를 위한 고장나무분석과 적용)

  • Kim, Jin-San;Choi, Jin-Sung;Bin, Jae-Goo;Kang, Feel-soon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.1
    • /
    • pp.33-39
    • /
    • 2017
  • A top priority in the design of underwater vehicle is to guarantee the dependability of the electric system because failure of the electrical power supply system is directly related to the life of the passengers. In this paper, we present four kinds of alternative designs to improve reliability of electrical system in underwater vehicle. To reduce the risk and to increase availability of the electrical system, we use the redundancy of the grid structure and power converter. For all design alternatives, we carry out Fault Tree Analysis. Based on the FTA result, we implement RAM simulation to compare the risk and availability for the proposed design alternatives.

The Study on the Lifetime Estimation using Fault Tree Analysis in Design Process of LNG Compressor (천연가스 압축기 설계 단계에서 FTA를 이용한 수명 예측 연구)

  • Han, Yongshik;Do, Kyu Hyung;Kim, Taehoon;Kim, Myungbae;Choi, Byungil
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.26 no.2
    • /
    • pp.192-198
    • /
    • 2015
  • Fault Tree Analysis to predict the lifetime in the design process of LNG compressor is considered. Fault Trees for P & ID of the compressor are created. Individual components that comprise the compressor are configured with the basic event. The failure rates in the PDS and OREDA are applied. As results, the system failure rate and the reliability over time are obtained. Further, the power transmission and the shaft seal system is confirmed to confidentially importantly contribute to the overall lifetime of the system. These techniques will help to improve the reliability of design of large scale machinery such as a plant.

A Case Study for Safety Analysis (안전성 분석에 대한 사례 연구)

  • Chang, Kwang-Chi;Lee, Key-Seo
    • Journal of the Korean Society for Railway
    • /
    • v.7 no.3
    • /
    • pp.251-258
    • /
    • 2004
  • A systematic methodology to determine safety requirements for railway signalling system and safety requirement allocation into system are presented. THR concept is used for as an interface between Risk Analysis to be performed by railway operator and System Design Analysis by the supplier. This approach is based on Signalling Safety Standard EN50129 by CENELEC.

Risk analysis of offshore terminals in the Caspian Sea

  • Mokhtari, Kambiz;Amanee, Jamshid
    • Ocean Systems Engineering
    • /
    • v.9 no.3
    • /
    • pp.261-285
    • /
    • 2019
  • Nowadays in offshore industry there are emerging hazards with vague property such as act of terrorism, act of war, unforeseen natural disasters such as tsunami, etc. Therefore industry professionals such as offshore energy insurers, safety engineers and risk managers in order to determine the failure rates and frequencies for the potential hazards where there is no data available, they need to use an appropriate method to overcome this difficulty. Furthermore in conventional risk based analysis models such as when using a fault tree analysis, hazards with vague properties are normally waived and ignored. In other word in previous situations only a traditional probability based fault tree analysis could be implemented. To overcome this shortcoming fuzzy set theory is applied to fault tree analysis to combine the known and unknown data in which the pre-combined result will be determined under a fuzzy environment. This has been fulfilled by integration of a generic bow-tie based risk analysis model into the risk assessment phase of the Risk Management (RM) cycles as a backbone of the phase. For this reason Fault Tree Analysis (FTA) and Event Tree Analysis (ETA) are used to analyse one of the significant risk factors associated in offshore terminals. This process will eventually help the insurers and risk managers in marine and offshore industries to investigate the potential hazards more in detail if there is vagueness. For this purpose a case study of offshore terminal while coinciding with the nature of the Caspian Sea was decided to be examined.

A Study on Design and Reliability Assessment for Embedded Hot-Standby Sparing FT System Using Self-Checking Logic (자기검사회로를 이용한 대기이중계구조 결함허용제어기의 설계 및 신뢰도평가에 관한 연구)

  • Lee, Jae-Ho;Lee, Kang-Mi;Kim, Young-Kyu;Shin, Duc-Ko
    • Journal of the Korean Society for Railway
    • /
    • v.9 no.6 s.37
    • /
    • pp.725-731
    • /
    • 2006
  • Hot Standby sparing system detecting faults by using software, and being tolerant any faults by using Hardware Redundancy is difficult to perform quantitative reliability prediction and to detect real time faults. Therefore, this paper designs Hot Standby sparing system using hardware basis self checking logic in order to overcome this problem. It also performs failure mode analysis of Hot Standby sparing system with designed self checking logic by using FMEA (Failure Mode Effect Analysis), and identifies reliability assessment of the controller designed by quantifying the numbers of failure development by using FTA (Fault Tree Analysis)

Reliability Evaluation of Resilient Safety Culture Using Fault Tree Analysis

  • Garg, Arun;Tonmoy, Fahim;Mohamed, Sherif
    • International conference on construction engineering and project management
    • /
    • 2020.12a
    • /
    • pp.303-312
    • /
    • 2020
  • Safety culture is a collection of the beliefs, perceptions and values that employees share in relation to risks within an organisation. On the other hand, a resilient safety culture (RSC) means a culture with readiness of the organisation to respond effectively under stress, bounce back from shocks and continuously learn from them. RSC helps organisations to protect their interest which can be attributed to behavioural, psychological and managerial capabilities of the organization. Quantification of the degree of resilience in an organisation's safety culture can provide insights about the strong and weak links of the organisation's overall health and safety situation by identifying potential causes of system or sub-system failure. One of the major challenges of quantification of RSC is that the attributes that determine RSC need to be measured through constructs and indicators which are complex and often interrelated. In this paper, we address this challenge by applying a fault tree analysis (FTA) technique which can help analyse complex and interrelated constructs and indicators. The fault tree model of RSC is used to evaluate resilience levels of two organisations with remote and urban locations in order to demonstrate the failure path of the weak links in the RSC model.

  • PDF

Failure analysis of capacitor for sub-module in HVDC (HVDC 서브모듈용 커패시터의 고장 분석)

  • Kang, Feel-soon;Song, Sung-Geun
    • Journal of IKEEE
    • /
    • v.22 no.4
    • /
    • pp.941-947
    • /
    • 2018
  • In general, capacitors have a large influence on the life of the system due to frequent charging and discharging. In this paper, we analyze the cause of the core failure of high voltage, high current HVDC sub-module film capacitor and analyze the precautions of the capacitor design and manufacturing process. First, the cause of the fault, the failure mode, and the effect are analyzed through the FMEA of the capacitor. To quantitatively evaluate the causes and effects of faults that have the greatest effect on the failure of a capacitor, a fault tree for the capacitor is presented and the failure rate is analyzed according to the design parameters and the driving conditions. It is verified that the main cause of capacitor failure is the capacitance change, and it is necessary to minimize the temperature rise, corona occurrence, electrode expansion, and insulation distance decrease during capacitor design and manufacturing process in order to reduce the failure rate of the capacitor.