• Title/Summary/Keyword: FSR(Force Sensing Resistor)

Search Result 26, Processing Time 0.022 seconds

Study on the Real-Time Walking Control of a Humanoid Robot U sing Fuzzy Algorithm

  • Kong, Jung-Shik;Lee, Eung-Hyuk;Lee, Bo-Hee;Kim, Jin-Geol
    • International Journal of Control, Automation, and Systems
    • /
    • v.6 no.4
    • /
    • pp.551-558
    • /
    • 2008
  • This paper deals with the real-time stable walking for a humanoid robot, ISHURO-II, on uneven terrain. A humanoid robot necessitates achieving posture stabilization since it has basic problems such as structural instability. In this paper, a stabilization algorithm is proposed using the ground reaction forces, which are measured using FSR (Force Sensing Resistor) sensors during walking, and the ground conditions are estimated from these data. From this information the robot selects the proper motion pattern and overcomes ground irregularities effectively. In order to generate the proper reaction under the various ground situations, a fuzzy algorithm is applied in finding the proper angle of the joint. The performance of the proposed algorithm is verified by simulation and walking experiments on a 24-DOFs humanoid robot, ISHURO-II.

Gait Phases Detection from EMG and FSR Signals in Walkingamong Children (근전도와 저항 센서를 이용한 보행 단계 감지)

  • Jang, Eun-Hye;Chi, Su-Young;Lee, Jae-Yeon;Cho, Young-Jo;Chun, Byung-Tae
    • Science of Emotion and Sensibility
    • /
    • v.13 no.1
    • /
    • pp.207-214
    • /
    • 2010
  • The aim of this study was to investigate upper and lower limb muscle activity using EMG(electromyogram) sensors while walking and identify normal gait pattern using FSR(force sensing resistor) sensor. Fifteen college students participated in this study and their EMG and FSR signal were measured during stopping and walking trials. EMG signals from upper(pectoralis major and trapezius) and lower limbs(rectus femoris, biceps femoris, vastus medialis, vastus lateralis, semimembranosus, semitendinosus, soleus, peroneus longus, gastrocnemius medialis, and gastrocnemius lateralis) were obtained using the surface electrodes. FSR measured pressures on 8 areas of the sole of the foot during walking. EMG results showed that all muscle activities except for vastus lateralis and semimembranosus during walking had higher amplitudes than stopping. Additionally, muscle activities associated with stance and swing phase during walking were identified. Results on FSR showed that stance and swing phases were detected by FSR signals during a gait cycle. Eight gait phases-initial contact, loading response, mid stance, terminal stance, pre swing, initial swing, mid swing, and terminal swing- were classified.

  • PDF

Analysis and Design of Humanoid Robot Foot using the Design of Experiments (실험 계획법을 이용한 휴머노이드 발의 설계 및 해석)

  • Yoo, Young-Kuk;Kim, Jin-Geol
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1791-1792
    • /
    • 2008
  • 휴머노이드 로봇은 기구적으로 불안정성을 내포하고 있기 때문에 이것에 대한 안정화를 하기 위해서 연구자들은 많은 방법을 사용하고 있다. 본 연구자는 실험 계획법(Design of Experiments)을 통해 본 연구자가 개발한 ISHURO-II의 발의 설계를 변경하였다. 퍼지 알고리즘을 이용하여 아랫부분에 장착된 FSR(Force Sensing Resistor)센서에서 ZMP(Zero Moment Point)의 값을 비교하여 더욱 안정된 보행이 가능하도록 하였다. 적용된 안정화 알고리즘의 성능은 VC++ 및 동역학 해석 프로그램을 이용한 시뮬레이션을 통해 검증하였다.

  • PDF

Development of a Portable Gait Phase Detection System for Patients with Gait Disorders

  • Ahn Seung Chan;Hwang Sung Jae;Kang Sung Jae;Kim Young Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.26 no.3
    • /
    • pp.145-150
    • /
    • 2005
  • A new gait detection system using both FSR (force sensing resistor) sensors and a gyrosensor was developed to detect various gait patterns. FSR sensors were put in self-designed shoe insoles and a gyrosensor was attached to the heel of a shoe. An algorithm was also developed to determine eight different gait transitions during four gait phases: heel-strike, foot-flat, heel-off and swing. The developed system was evaluated from nine heathy mans and twelve hemiplegic patients. Healthy volunteers were asked to walk in various gait patterns: level walking, fore-foot walking and stair walking. Only the level walking was performed in hemiplegic patients. The gait detection system was compared with a optical motion analysis system and the outputs of the FSR sensors. In healthy subjects, the developed system detected successfully more than $99\%$ for both level walking and fore-foot walking. For stair walking, the successful detection rate of the system was above$97\%$. In hemiplegic patients, the developed system detected approximately 98% of gait transitions. The developed gait phase detection system will be helpful not only to determine pathological gait phases but also to apply prosthetics, orthotics and functional electrical stimulation for patients with various gait disorders.

A Study on Walking Stabilization and Path Tracking of Biped Robot Using RFID (이족 보행 로봇의 보행 안정화 및 RFID를 이용한 경로 추종에 관한 연구)

  • Park, Jong-Han;Kim, Yong-Tae
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.23 no.1
    • /
    • pp.51-56
    • /
    • 2013
  • In order to apply a biped robot in real world, the robot requires a robust walking and a function of localization, path planning and navigation. Recently, localization and path planning using RFID of mobile robot has been studying. However, when the biped robot walks, it has unstability and tends to leave the path. In the paper we propose a method of walking stabilization using FSR(Force Sensing Resistor), Gyro and accelerometer for the real biped robot. Also a path tracking algorithm using RFID sensor attached in robot's foot is proposed based on localization of the robot. The proposed algorithm is verified from walking experiments using real biped robot on uneven terrain and path tracking experiments on the RFID environments.

Measurement and analysis of body pressure distribution on a bed

  • 박세진;황민철;김창범
    • Proceedings of the ESK Conference
    • /
    • 1995.04a
    • /
    • pp.55-61
    • /
    • 1995
  • We spend about 40% of lifte time on a bed and seek how such amount of time is spent comfort. Bed comfort has been pursuited. The pressure distributions on a bed by body pressure has been considered as one of the most important factors of bed comfort. This study is to quantify the subjective assessment by the body pressure distribution and develop the objective evaluation method of bed comfort. A new measurement system for body pressure on a bed was developed in this study. The thin film pressure sensor (FSR: Force Sensing Resistor) of an elastomer-type was used to prevent the distortion of contact pressure. The pressure distribution is measured by FSR and displayed on the monitor by color-coded contour patterns. Some of the bed test results were described. And the relations between body pressure distribution and bed comfort were evaluated.

  • PDF

Algorithm development of a body pressure detection sensor for the occupant classification system (고안전 에어백의 승객 분류를 위한 체압감지 센서를 위한 알고리즘 개발)

  • Yun, Duk-Sun;Oh, Seong-Rok;Song, Jeong-Hoon;Kim, Byeong-Soo;Boo, Kwang-Suck
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.5
    • /
    • pp.385-392
    • /
    • 2009
  • This paper describes the algorithm development of a new body pressure detection sensor for occupant classification system. U.S. Government has required that advanced airbag system should be installed to every automobiles after 2006 according to FMVSS 208 regulation. Therefore, Occupant Classification System should be provided the passenger with safety in order to protect the infants or children that sit in the front passenger seat. When an occupant sits on the chair of the vehicle, deployment of the airbag depends on passenger's weigh distribution and postures. Authors have been developed a new pattern recognition of passenger and weight distribution at the same time by Force Sensing Resistor for the safety.

Characteristic Evaluation of Pressure Mapping System for Patient Position Monitoring in Radiation Therapy

  • Kang, Seonghee;Choi, Chang Heon;Park, Jong Min;Chung, Jin-Beom;Eom, Keun-Yong;Kim, Jung-in
    • Progress in Medical Physics
    • /
    • v.32 no.4
    • /
    • pp.153-158
    • /
    • 2021
  • Purpose: This study evaluated the features of a pressure mapping system for patient motion monitoring in radiation therapy. Methods: The pressure mapping system includes an MS 9802 force sensing resistor (FSR) sensor with 2,304 force sensing nodes using 48 columns and 48 rows, controller, and control PC (personal computer). Radiation beam attenuation caused by pressure mapping sensor and signal perturbation by 6 and 10 mega voltage (MV) photon beam was evaluated. The maximum relative pressure value (mRPV), average relative pressure value (aRPV), the center of pressure (COP), and area of pressure distribution were obtained with/without radiation using the upper body of an anthropomorphic phantom for 30 minutes with 15 MV. Results: It was confirmed that the differences in attenuation induced by the FSR sensor for 6 and 10 MV photon beams were small. The differences in mRPV, aRPV, area of pressure distribution with/without radiation are about 0.6%, 1.2%, and 0.5%, respectively. The COP values with/without radiation were also similar. Conclusions: The characteristics of a pressure mapping system during radiation treatment were evaluated on the basis of attenuation and signal perturbation using radiation. The pressure distribution measured using the FSR sensor with little attenuation and signal perturbation by the MV photon beam would be helpful for patient motion monitoring.

Walking Intention Detection using Fusion of FSR and Tilt Sensor Signals (저항 센서와 기울기 센서의 융합에 의한 보행 의도 감지)

  • Jang, Eun-Hye;Chun, Byung-Tae;Lee, Jae-Yeon;Chi, Su-Young;Kang, Sang-Seung;Cho, Young-Jo
    • Science of Emotion and Sensibility
    • /
    • v.13 no.3
    • /
    • pp.441-448
    • /
    • 2010
  • In the aging society, the walking assist robot is a necessary device for being able to help the older and the lower limb disabled people to walk. In order to produce a convenient robot for the older and the lower limb disabled, it is needed for the research to detect the implicit walking intention and to control robot by a user's intention. This study is a previous study to develop the detection model of the walking intention and analyze the user's walking intention while a person is walking with Lofstrand crutches, by the combination of FSR and tilt signals. The FSR sensors attached user's the palm and the soles of foot are sensing force/pressure signals from these areas and are used for detecting the walking intention and states. The tilt sensor acquires roll and pitch signal from area of vertebrae lumbales and reflects the pose of the upper limb. We can recognize the user's walking intention such as 'start walking', 'start of right or left foot forward', and 'stop walking' by the combination of FSR and tilt signals can recognize.

  • PDF

Wearable and Motorized Crutch Control System (착용형 전동 목발 제어시스템)

  • Yoon, Dukchan;Jang, Giho;Choi, Youngjin
    • The Journal of Korea Robotics Society
    • /
    • v.9 no.3
    • /
    • pp.133-139
    • /
    • 2014
  • This paper proposes a wearable and motorized crutch control system for the patients using the conventional crutches. The conventional crutches have a few disadvantages such as the inconvenience caused by the direct contact between the ground and the armpit of the patients, and unstable gait patterns. In order to resolve these problems, the motorized crutch is designed as a wearable type on an injured lower limb. In other words, the crutch makes the lower limb to be moved forward while supporting the body weight, protecting the lower limb with frames, and rotating a roller equipped on the bottom of the frames. Also the crutch is controlled using the electromyography and two force sensing resistor (FSR) sensors. The electromyography is used to extract the walking intention from the patient and the FSR sensors to classify the stance and swing phases while walking. As a result, the developed crutch makes the patients walk enabling both hands to be free, as if normal people do.