• Title/Summary/Keyword: FSI Analysis

Search Result 274, Processing Time 0.024 seconds

Analysis of Traffic Accident by Circular Intersection Type in Korea Using Count Data Model (가산자료 모형을 이용한 국내 원형교차로 유형별 교통사고 분석)

  • Kim, Tae Yang;Lee, Min Yeong;Park, Byung Ho
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.5
    • /
    • pp.129-134
    • /
    • 2017
  • This study aims to develop the traffic accident models by circular intersection type using count data model. The number of accident, the number of fatal and injured persons(FSI), and EPDO are calculated from the traffic accident data of TAAS. The circular intersection accident models are developed through Poisson and negative binomial regression analysis. The main results of this study are as follows. First, the null hypotheses that there are differences in the number of traffic accidents, FSI and EPDO by type of circular intersections are rejected. Second, the scale of intersection(median, large), number of approach road, mean width and length of exit road, area of the circulating roadway and central island are selected as factors influencing the number of traffic accidents, FSI and EPDO in rotary. Third, the scale of intersection(median), guide signs(limited speed, direction, roundabout), number of approach road, entry angle, area of the intersection and central island are adopted as factors influencing the number of traffic accidents, FSI and EPDO in roundabout. Finally, transferring from rotary to roundabout could be expected to make the accident decrease.

A Numerical Analysis with the FSI Mode on the Characteristics of Flow Field and Discharge Valve Motion in a Rotary Compressor (로터리 압축기의 토출밸브의 미소 거동 및 유동 특성에 대한 FSI(Fluid-Structure Interaction) 기법을 이용한 수치해석)

  • Chae, Hee-Moon;Kim, Chang-Nyung;Park, Sung-Kwan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.5
    • /
    • pp.112-120
    • /
    • 2008
  • This study has been conducted to investigate the characteristics of flow field and discharge valve motion in a rotary compressor. In this study, a transient three-dimensional numerical analysis using FSI(Fluid-Structure Interaction) model has been employed to analyze the interaction between the discharge valve and the refrigerants in the rotary compressor. It has been observed that two peaks have appeared in the displacement of the discharge valve. The maximum displacement of the discharge valve has been found to be located at the second peak. Also, the input pressure of the refrigerants has been compared with the pressures of the muffler passage and the compressor outlet in the rotary compressor. The pressure has decreased along the pathway in the rotary compressor. And the volume flow rates obtained from the current numerical study have been compared with the experiment at data to verify the validity of the present numerical study. This study may supply the fundamental data for the design of rotary compressors.

Estimation of Acceleration Response of Freefall Lifeboat using FSI Analysis Technique of LS-DYNA Code (LS-DYNA 코드의 유체-구조 연성해석 기법을 이용한 자유낙하식 구명정의 가속도 응답 추정)

  • Bae, Dong-Myung;Zakki, A.F.;Kim, Hag-Soo;Kim, Joo-Gon
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.47 no.5
    • /
    • pp.681-688
    • /
    • 2010
  • During certification of freefall lifeboats, it is necessary to estimate the injury potential of the impact loads exerted on the occupants during water entry. This paper focused on the numerical simulation to predict the acceleration response during the impact of freefall lifeboats on the water using FSI(Fluid-Structure Interaction) analysis technique of LS-DYNA code. FSI problems could be conveniently simulated by the overlapping capability using Arbitrary Lagrangian Eulerian(ALE) formulation and Euler-Lagrange coupling algorithm of LS-DYNA code. Through this study, it could be found that simulation results were in relatively good agreement with experimental ones in the acceleration peak values, and that the loading conditions were very sensitive to the acceleration responses by the experimental and simulation results.

Structural Analysis on the Arm and Floater Structure of a Wave Energy Converter

  • Chen, Zhenmu;Singh, Patrick Mark;Choi, Young-Do
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.3
    • /
    • pp.5-11
    • /
    • 2015
  • Ocean waves have huge amounts of energy, even larger than wind or solar, which can be extracted by some mechanical device. This can be done by creating a system of reacting forces, in which two or more bodies move relative to each other, while at least one body interacts with the waves. This moves the floater up and down. The floaters are connected to an arm structure, which are mounted on a fixed hull structure. Hence, the structure of the floater is very important. A static structural analysis with FSI (Fluid-Structure Interaction) analysis is conducted. To achieve the pressure load for the FSI analysis, the floater is simulated on a wave generator using rigid body motion. The structural analysis is done to examine the stresses on the whole system, and four types of flange and floater are optimized. The result shows that the structure of floater with wood support is the safest.

Adaptive fluid-structure interaction simulation of large-scale complex liquid containment with two-phase flow

  • Park, Sung-Woo;Cho, Jin-Rae
    • Structural Engineering and Mechanics
    • /
    • v.41 no.4
    • /
    • pp.559-573
    • /
    • 2012
  • An adaptive modeling and simulation technique is introduced for the effective and reliable fluid-structure interaction analysis using MSC/Dytran for large-scale complex pressurized liquid containment. The proposed method is composed of a series of the global rigid sloshing analysis and the locally detailed fluid-structure analysis. The critical time at which the system exhibits the severe liquid sloshing response is sought through the former analysis, while the fluid-structure interaction in the local region of interest at the critical time is analyzed by the latter analysis. Differing from the global coarse model, the local fine model considers not only the complex geometry and flexibility of structure but the effect of internal pressure. The locally detailed FSI problem is solved in terms of multi-material volume fractions and the flow and pressure fields obtained by the global analysis at the critical time are specified as the initial conditions. An in-house program for mapping the global analysis results onto the fine-scale local FSI model is developed. The validity and effectiveness of the proposed method are verified through an illustrative numerical experiment.

A Study on the Flow Characteristics of Piezoelectric Micropumps with Different Numerical Models (수치 모델에 따른 압전 구동방식 마이크로 펌프의 유동특성에 관한 연구)

  • Jung, Jin;Kim, Dong-Hee;Kim, Chang-Nyeong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.8
    • /
    • pp.707-713
    • /
    • 2004
  • A numerical analysis has been conducted for flow characteristics of piezoelectric micropumps. In the present study, FSI (Fluid-Structure Interaction) model and grid deform model have been employed for each of two different geometries of the micropumps with two different frequencies in the piezoelectric diffuser/nozzle based micropumps. The displacement of piezo disk and flow rates have been closely examined at the inlet and outlet. It has been found that the motion of the piezo disk investigated with FSI model is not in accordance with that with grid deform model. The results show that the time averaged flow rate calculated with FSI model is larger than that with grid deform model. This study presents the performance analysis of piezoelectric micropumps with two different numerical models for different types of pumps.

Dynamic characteristics assessment of reactor vessel internals with fluid-structure interaction

  • Je, Sang Yun;Chang, Yoon-Suk;Kang, Sung-Sik
    • Nuclear Engineering and Technology
    • /
    • v.49 no.7
    • /
    • pp.1513-1523
    • /
    • 2017
  • Improvement of numerical analysis methods has been required to solve complicated phenomena that occur in nuclear facilities. Particularly, fluid-structure interaction (FSI) behavior should be resolved for accurate design and evaluation of complex reactor vessel internals (RVIs) submerged in coolant. In this study, the FSI effect on dynamic characteristics of RVIs in a typical 1,000 MWe nuclear power plant was investigated. Modal analyses of an integrated assembly were conducted by employing the fluid-structure (F-S) model as well as the traditional added-mass model. Subsequently, structural analyses were carried out using design response spectra combined with modal analysis data. Analysis results from the F-S model led to reductions of both frequency and Tresca stress compared to those values obtained using the added-mass model. Validation of the analysis method with the FSI model was also performed, from which the interface between the upper guide structure plate and the core shroud assembly lug was defined as the critical location of the typical RVIs, while all the relevant stress intensities satisfied the acceptance criteria.

Fluid-structure interaction analysis on a low speed 200 W-class gyromill type vertical axis wind turbine rotor blade (200 W급 자이로밀형 수직축 풍력터빈 로터 블레이드 유체-구조 연성 해석)

  • Cho, Woo-Seok;Choi, Young-Do;Kim, Hyun-Su
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.4
    • /
    • pp.344-350
    • /
    • 2013
  • The purpose of this study is to examine the structural stability of a low speed 200 W class gyromill type vertical axis wind turbine system. For the analysis, a commercial code is adopted. The pressure distribution on the rotor blade surface is examined in detail. In order to perform unidirectional FSI(Fluid-Structure Interaction) analysis, the pressure resulted from CFD analysis has been mapped on the surface of wind turbine as load condition. The rotational speed and gravitational force of wind turbine are also considered. The results of FSI analysis show that the wind turbine reveals an enough structural margin. The maximum structural displacement occurs at trailing edge of blade and the maximum stress occurs at the strut.

Verification of Underwater Blasting Response Analysis of Air Gun Using FSI Analysis Technique (FSI 해석기법을 이용한 에어건 수중발파 응답해석 검증)

  • Lee, Sang-Gab;Lee, Jae-Seok;Park, Ji-Hoon;Jung, Tae-Young;Lee, Hwan-Soo;Park, Kyung-Hoon
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.54 no.6
    • /
    • pp.522-529
    • /
    • 2017
  • Air gun shock system is used as an alternative energy source as part of the attempt to overcome the restrictions of economical expense and environmental damage, etc., due to the use of explosives for the UNDerwater EXplosion (UNDEX) shock test. The objectivity of this study is to develop the simulation technique of air gun shock test for the design of model-scale one for the near field non-explosive UNDEX test through its verification with full-scale SERCEL shock test result. Underwater blasting response analysis of full-scale air gun shock test was carried out using highly advanced M&S (Modeling & Simulation) system of FSI (Fluid-Structure Interaction) analysis technique of LS-DYNA code, and was verified by comparing its shock characteristics and behaviors with the results of air gun shock test.