• Title/Summary/Keyword: FSI(Fluid Structure Interaction) analysis

Search Result 174, Processing Time 0.026 seconds

Fluid-Structure Interaction Analysis of Two-Dimensional Wings (2차원 날개의 유체-구조 연성해석)

  • Ahn, Byoung-Kwon;Lee, Suk-Jeong;Kim, Ji-Hye;Kim, Ki-Sup
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.50 no.5
    • /
    • pp.343-348
    • /
    • 2013
  • When a natural frequency of the trailing edge of a wing is close to a vortex shedding frequency, an amplitude of the edge oscillation becomes maximal; it makes intensive noise called singing. Motion of the trailing edge may also feedback to the vortex shedding so that self-sustained oscillation appears, and a resonant frequency is locked in some interval of the speed of the incident flow. In this study, we first evaluate main features of oscillating characteristics of the wing. Second we simulate fluid-structure interaction of the wing with a flap using a commercial code, ANSYS-CFX, and investigate lift characteristics in a frequency domain.

Dynamic behavior of intake tower considering hydrodynamic damping effect

  • Uddin, Md Ikram;Nahar, Tahmina Tasnim;Kim, Dookie;Kim, Kee-Dong
    • Structural Engineering and Mechanics
    • /
    • v.82 no.3
    • /
    • pp.355-367
    • /
    • 2022
  • The effect of hydrodynamic damping on intake tower is twofold: one is fluid damping and another is structural damping. Fluid damping can be derived analytically from the governing equation of the fluid-structure-interaction (FSI) problem which yields a very complicated solution. To avoid the complexity of the FSI problem water-tower system can be simplified by considering water as added mass. However, in such a system a reconsideration of structural damping is required. This study investigates the effects of this damping on the dynamic response of the intake tower, where, apart from the "no water (NW)" condition, six other cases have been adopted depending on water height. Two different cross-sections of the tower are considered and also two different damping properties have been used for each case as well. Dynamic analysis has been carried out using horizontal ground motion as input. Finally, the result shows how hydrodynamic damping affects the dynamic behavior of an intake tower with the change of water height and cross-section. This research will help a designer to consider more conservative damping properties of intake tower which might vary depending on the shape of the tower and height of water.

Verification of Underwater Blasting Response Analysis of Air Gun Using FSI Analysis Technique (FSI 해석기법을 이용한 에어건 수중발파 응답해석 검증)

  • Lee, Sang-Gab;Lee, Jae-Seok;Park, Ji-Hoon;Jung, Tae-Young;Lee, Hwan-Soo;Park, Kyung-Hoon
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.54 no.6
    • /
    • pp.522-529
    • /
    • 2017
  • Air gun shock system is used as an alternative energy source as part of the attempt to overcome the restrictions of economical expense and environmental damage, etc., due to the use of explosives for the UNDerwater EXplosion (UNDEX) shock test. The objectivity of this study is to develop the simulation technique of air gun shock test for the design of model-scale one for the near field non-explosive UNDEX test through its verification with full-scale SERCEL shock test result. Underwater blasting response analysis of full-scale air gun shock test was carried out using highly advanced M&S (Modeling & Simulation) system of FSI (Fluid-Structure Interaction) analysis technique of LS-DYNA code, and was verified by comparing its shock characteristics and behaviors with the results of air gun shock test.

Fluid-Structure Interaction Analysis for Open Water Performance of 100 kW Horizontal Tidal Stream Turbine (유체-구조 연성을 고려한 100 kW급 수평축 조류발전 터빈의 단독성능 해석)

  • Park, Se Wan;Park, Sunho;Rhee, Shin Hyung
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.17 no.1
    • /
    • pp.20-26
    • /
    • 2014
  • It is essential to consider the effect of blade deformation in order to design a better tidal stream turbine being operated in off-design condition. Flow load causes deformation on the blade, and the deformation affects the turbine performance. In the present study, CFD analysis procedures were developed to predict open water performance of horizontal axis tidal stream turbine (HATST). The developed procedures were verified by comparing the results with existing experimental results. Fluid-structure interaction (FSI) analysis method, based on the verified CFD procedure, have been carried out to estimate the turbine performance for a turbine with flexible composite blades, and then the results were compared with those for rigid blades.

Analysis of Vortex Vibration by Using the FSI Technique (FSI 기법을 이용한 와류진동 해석)

  • Kim, Dae-Geun;Kim, Sung-Man
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2010.05a
    • /
    • pp.754-758
    • /
    • 2010
  • 케이블 교량에서 발생하는 사장케이블의 진동현상에 대한 현상학적 특성을 명확히 이해해야, 사장케이블의 적합한 제진설계가 가능하다. 본 연구에서는 유체의 흐름과 구조물의 진동을 동적으로 연계하여 해석하기 위하여, ADINA의 CFD 및 Structure 코드를 동적으로 연계하는 FSI(Fluid Flow with Structure Interaction) 기법을 이용하였다. 바람으로 인해 이중원형실린더의 풍상측과 풍하측 실린더에서는 와류가 방출되면서 외력이 작용하게 되며, 이러한 공기력은 풍하측 실린더의 고유진동 운동과 함께 와류진동현상을 유발한다. 본 연구에서는 풍하측 실린더의 와류진동 현상의 해석에 주안점을 두었다. 본 연구에서는 흐름의 레이놀즈수와 이중원형실린더에 대한 바람의 입사각을 변화시키며 풍하측 실린더에서 발생하는 와류진동의 크기를 분석하였다. 본 연구결과, 유입풍속 및 바람의 입사각에 따라 이중원형실린더에서 발생하는 일반적인 와류방출현상과 풍하측 실린더에 작용하는 공기력 및 변위양상을 예측할 수 있었다. 특히, 바람의 입사각이 $15^{\circ}$인 경우에는 풍하측 실린더에서 방출되는 와류로 인해 풍하측 실린더에는 비대칭의 공기력이 작용하며, 이는 풍하측 실린더가 2사분면에서 4사분면 방향으로 진동하는 원인이 되는 것으로 판단된다.

  • PDF

FSI Simulation of the Sail Performance considering Standing Rig Deformation (리그변형을 고려한 세일 성능의 유체-구조 연성해석)

  • Bak, Sera;Yoo, Jaehoon
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.55 no.5
    • /
    • pp.421-430
    • /
    • 2018
  • The shape of a yacht sail made of thin fabric materials is easily deformed by wind speed and direction and it is affected by the deformation of the standing rig such as mast, boom, shrouds, stays and spreaders. This deformed sail shape changes the air flow over the sail, it makes the deformation of the sail and the rig again. To get a sail performance accurately these interactive behavior of sail system should be studied in aspects of the aerodynamics and the fluid-structure interaction. In this study aerodynamic analysis for the sail system of a 30 feet sloop is carried out and the obtained dynamic pressure on the sail surface is applied as the loading condition of the calculation to get the deformations of the sail shape and the rig. Supporting forces by rig are applied as boundary condition of the structure deformation calculations. And the characteristics of the air flow and the dynamic pressure over the deformed sail shape is investigated repeatedly including the lift force and the location of CE.

The FSI Analysis Evaluation of Strength for the Wind Turbine Rotor Blade Improved by the Aramid Fiber (아라미드섬유 보강 풍력발전기 로터 블레이드의 연성해석 강도평가)

  • Kim, Seok-Su;Kang, Ji-Woong;Kwon, Oh-Heon
    • Journal of Power System Engineering
    • /
    • v.19 no.4
    • /
    • pp.17-23
    • /
    • 2015
  • Because of the energy resources shortage and global pollution, the wind power systems have been developed consistently. Among the components of the wind power system, the rotor blades are the most important component. Generally it is made of GFRP material. Recently, GFRP material has been replaced by CFRP composite material in the blade which has an aerodynamic profile and twisted tip. However the failures has occurred in the trailing edge of the blade by the severe wind loading. Thus, tougher material than CFRP material is needed as like the aramid fiber. In this study, we investigated the mechanical behaviors of the blade using aramid fiber composites about wind speed variation. One-way FSI (fluid-structure interaction)analysis for the wind rotor blade was conducted. The structural analyses using the surface pressure loading resulted from wind flow field analysis were carried out. The results and analysis procedure in this paper can be utilized for the best strength design of the blade with aramid fiber composites.

Structure Analysis and Torque Reduction Design of Industrial Ball Valve (산업용 볼밸브의 구조 해석 및 토크 저감 설계)

  • Ha, Sun-Ho;Kim, Sang-Jin;Song, Jung-Il
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.13 no.6
    • /
    • pp.37-45
    • /
    • 2014
  • Ball valves are used as a key element in the process industries. The industrial development of valves has increased steadily, but continued improvement requires high design reliability and long service life. Currently, the development of high performance valves is not easy because of the lack of relevant technology in Korea. Valves are being imported at a level of up to 58 percent of the domestic market, which represents a value of almost 7 million US dollars. Therefore, in this work, the improvement of the design and performance of industrial valves has been studied in an attempt to achieve valves that will have longer service life and better output during operation. The structural stability was evaluated using the ANSYS FSI (Fluid-Structural Interaction) module. Moreover, to obtain maximum product reliability, torque analysis simulation was performed to compare and experimental results. The simulation results were used to predict the change in torque by changes in shape, thereby reducing the time and cost of manufacturing a number of prototypes for experimental validation.

A Numerical Analysis on the Motion of a Curved Bileaflet in Mechanical Heart Valve(MHV) and the Characteristics of Blood Flow in an Elastic Blood Vessel (탄성혈관 내 곡면형 이엽 기계식 인공심장판막의 거동 및 혈액 유동 특성에 관한 수치해석적 연구)

  • Bang J. S.;Choi C. R.;Kim C. N.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2004.10a
    • /
    • pp.203-206
    • /
    • 2004
  • In this study, a numerical analysis has been performed for a three-dimensional pulsatile blood flow associated with the elastic blood vessel and curved bileaflet for multiple cycles in terms of fluid-structure interaction. Here, blood has been assumed as a Newtonian, incompressible fluid. Pressure profiles have been used as boundary conditions at the ventricle and the aorta. From this analysis, the motion of the leaflet has been observed with fluttering phenomenon and rebound, and the flow fields of blood have been obtained with recirculation and regurgitation. The results can contribute to the development of design methodology for the curved bileaflet mechanical heart valve.

  • PDF

Study on Analysis Method for Fire Safety Test of Hydrant Reducing Valve for Offshore Plant (해양 플랜트용 Hydrant Reducing Valve의 화재 안전시험에 대한 해석 기법 연구)

  • Jeong, Yun Sang;Kang, Jung Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.6
    • /
    • pp.601-608
    • /
    • 2014
  • An offshore plant is vulnerable to fire because of the isolated environment. In particular, the damage to an offshore plant is increased when a hydrant reducing valve, which is a main piece of equipment in an offshore plant, is damaged in a fire. In this study, we conducted a fire safety test for a hydrant reducing valve and proved the validity of our analysis by comparing the results of the test and analysis. Therefore, we here suggest an analysis method for a fire safety test. FSI(fluid structure interaction) was considered in the fire safety test. The reliability of the analysis method was verified by comparing the temperature distributions of the test and analysis. In addition, we verified the problems that were caused in the fire safety test by conducting a structure analysis. At a result, the main problem was found to be deformation of the valve seat.