• 제목/요약/키워드: FRP laminate

검색결과 48건 처리시간 0.024초

Finite element modeling methodologies for FRP strengthened RC members

  • Park, Sangdon;Aboutaha, Riyad
    • Computers and Concrete
    • /
    • 제2권5호
    • /
    • pp.389-409
    • /
    • 2005
  • The Finite Element Analysis (FEA) is evidently a powerful tool for the analysis of structural concrete having nonlinearity and brittle failure properties. However, the result of FEA of structural concrete is sensitive to two modeling factors: the shear transfer coefficient (STC) for an open concrete crack and force convergence tolerance value (CONVTOL). Very limited work has been done to find the optimal FE Modeling (FEM) methodologies for structural concrete members strengthened with externally bonded FRP sheets. A total of 22 experimental deep beams with or without FRP flexure or/and shear strengthening systems are analyzed by nonlinear FEA using ANAYS program. For each experimental beams, an FE model with a total of 16 cases of modeling factor combinations are developed and analyzed to find the optimal FEM methodology. Two elements the SHELL63 and SOLID46 representing the material properties of FRP laminate are investigated and compared. The results of this research suggest that the optimal combination of modeling factor is STC of 0.25 and CONVTOL of 0.2. A SOLID 46 element representing the FRP strengthening system leads to better results than a SHELL 63 element does.

An Analytical Model for FRP Debonding in Strengthened RC Beams under Monotonic and Cyclic Loads

  • Moein, Reza Saeidi;Tasnimi, Abbas Ali
    • International Journal of Concrete Structures and Materials
    • /
    • 제10권4호
    • /
    • pp.499-511
    • /
    • 2016
  • Reinforced concrete (RC) beams strengthened by externally bonded reinforcement often fail by debonding. This paper presents an experimental and analytical study aimed at better understanding and modeling the fiber reinforced polymer (FRP) debonding failures in strengthened RC beams under monotonic and cyclic loads. In order to investigate the flexural behavior and failure modes of FRP-strengthened beams under monotonic and cyclic loadings, an experimental program was carried out. An analytical study based on the energy balance of the system was also performed. It considers the dominant mechanisms of energy dissipation during debonding and predicts the failure load of the strengthened beams. Validation of the model was carried out using test data obtained from the own experimental investigation.

자외선 파장에 따른 FRP의 표면 열화특성 및 열화메커니즘에 관한 연구 (A Study on the Characteristics of Surface Degradation & Degradation-Mechanism in UV Treated FRP)

  • 이백수;임경범;나동근;정무영;정의남;유도현;이덕출
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.813-815
    • /
    • 1998
  • In order to analyse the degradation process of epoxy/glass fiber for outdoor condition, FRP laminate was exposed to the wavelength of ultraviolet rays and evaluated by comparing contact angle, surface resistivity, surface potential decay, and ESCA spectrum respectively. Finally, We can conclude that the degradation phenomena on the surface of epoxy composites are dominated by the induction of ester and carboxyl groups.

  • PDF

열철리에 따른 Epoxy 복합재료의 표면 소수성증가에 관한 해석 (Analyses on the Increment of Surface Hydrophobicity of Epoxy Composites by Thermal Treatment)

  • 임경범;이백수;정무영;이덕출
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권4호
    • /
    • pp.153-160
    • /
    • 2001
  • In order to analyze the degradation process of epoxy/glass fiber for outdoor condition, FRP laminate was exposed to high temperature. Then, the degradation process was evaluated by comparing contact angle, surface potential, surface resistivity, and XPS. The experimental results showed that the amount of weight loss, contact angle, surface potential and surface resistivity increased up to 200 $^{\circ}C$ as a function of temperature. These phenomena show the existence of hydrophobic surface. With the change to the hydrophobic surface and the electrical potential and resistivity on FRP surface increased. In XPS to analyze surface chemical structures, the increased hydrophobicity in thermal increase of unsaturated double bond in carbon chains. Aslo, thermal treatment caused the discoloration on the point of treated surface. These phenomena were attributed to the generations of ether group.

  • PDF

비정질 할로이사이트 나노입자의 교차적층 구조에 따른 탄소섬유/에폭시 라미네이트의 저속 충격 특성 (Low Velocity Impact Property of CF/Epoxy Laminate according to Interleaved Structure of Amorphous Halloysite Nanotubes)

  • 박예림;;김윤해
    • Composites Research
    • /
    • 제36권4호
    • /
    • pp.270-274
    • /
    • 2023
  • 필라멘트 와인딩 공정을 사용한 FRP 복합재의 적층 구조는 기존의 FRP 복합재의 적층 구조와는 다를 뿐만 아니라 일반적인 적층 구조를 토대로 기계적 물성에 대해서 분석하고자 한다면 그에 대한 영향을 파악하는 것이 어렵다. 따라서 전반적인 성능을 향상시키기 위해 기계적 물성을 개선하고 교차 적층 구조를 최적화하는 것이 필수적이다. 따라서 본 연구는 비정질 할로이사이트 나노튜브(Amorphous Halloysite Nanotubes, A-HNT)를 5개의 층 배열을 통해 교차 적층 탄소 섬유 강화 플라스틱(CFRP) 구조의 저속 충격 특성에 미치는 영향을 조사하는 것을 목표로 한다. 중량 낙하식 충격시험을 통하여 라미네이트의 저속 충격 특성을 확인하였으며, 충격을 가한 후에 현미경을 통하여 충격 파손 모드와 손상 정도를 비교 평가하였다. 나노 입자의 첨가 여부에 따른 각각의 교차 적층 구조 라미네이트를 10 J과 15 J의 충격에너지에서 비교하였다. 10 J의 경우 흡수에너지는 각 구조에서 비슷한 경향을 보였다. 그에 비해 15 J의 경우 흡수에너지는 각 구조에서 다른 흡수에너지를 가지며, 나노 입자가 첨가되지 않은 구조가 가장 높은 흡수에너지를 가진다. 또한 광학현미경을 통하여 각 구조에서 다양한 충격 파손 모드가 관찰되었다.

Finite element analysis of CFRP laminate repairs on damaged end regions of prestressed concrete bridge girders

  • Shaw, Ian D.;Andrawes, Bassem
    • Advances in Computational Design
    • /
    • 제2권2호
    • /
    • pp.147-168
    • /
    • 2017
  • Over the past couple decades, externally bonded fiber reinforced polymer (FRP) composites have emerged as a repair and strengthening material for many concrete infrastructure applications. This paper presents an analytical investigation of the use of carbon FRP (CFRP) for a specific problem that occurs in concrete bridge girders wherein the girder ends are damaged by excessive exposure to deicing salts and numerous freezing/thawing cycles. A 3D finite element (FE) model of a full scale prestressed concrete (PC) I-girder is used to investigate the effect of damage to the cover concrete and stirrups in the end region of the girder. Parametric studies are performed using externally bonded CFRP shear laminates to determine the most effective repair schemes for the damaged end region under a short shear span-to-depth ratio. Experimental results on shear pull off tests of CFRP laminates that have undergone accelerated aging are used to calibrate a bond stress-slip model for the interface between the FRP and concrete substrate and approximate the reduced bond stress-slip properties associated with exposure to the environment that causes this type of end region damage. The results of these analyses indicate that this particular application of this material can be effective in recovering the original strength of PC bridge girders with damaged end regions, even after environmental aging.

Mechanical properties of thin-walled composite beams of generic open and closed sections

  • Rajasekaran, S.
    • Structural Engineering and Mechanics
    • /
    • 제21권5호
    • /
    • pp.591-620
    • /
    • 2005
  • A general analytical model for thin-walled composite beams with an arbitrary open/(or/and) closed cross section and arbitrary laminate stacking sequence i.e., symmetric, anti-symmetric as well as un-symmetric with respect to the mid plane of the laminate, is developed in the first paper. All the mechanical properties, mechanical centre of gravity and mechanical shear centre of the cross section are defined in the function of the geometry and the material properties of the section. A program "fungen" and "clprop" are developed in Fortran to compute all the mechanical properties and tested for various isotropic sections first and compared with the available results. The locations of mechanical centre of gravity and mechanical shear centre are given with respect to the fibre angle variation in composite beams. Variations of bending and torsional stiffness are shown to vary with respect to the fibre angle orientations.

Failure mechanisms of hybrid FRP-concrete beams with external filament-wound wrapping

  • Chakrabortty, A.;Khennane, A.
    • Advances in concrete construction
    • /
    • 제2권1호
    • /
    • pp.57-75
    • /
    • 2014
  • This paper presents an analysis of the results of an experimental program on the performance of a novel configuration of a hybrid FRP-concrete beam. The beam section consists of a GFRP pultruded profile, a CFRP laminate, and a concrete block all wrapped up using filament winding. It was found that the thickness of the concrete block and the confinement by the filament-wound wrapping had a profound effect on the energy dissipation behaviour of the beam. Using a shear punching model, and comparing the predicted results with the experimental ones, it was found that beyond a given value of the concrete block thickness, the deformational behaviour of the beam shifts from brittle to ductile. It was also found that the filament-wound wrap had many benefits such as providing a composite action between the concrete block and the GFRP box, improving the stiffness of the beam, and most importantly, enhancing the load carrying ability through induced confinement of the concrete.

자외선 처리된 Epoxy/Glass Fiber의 표면 열화 특성에 관한 연구 (A Study on the Surface Degradation Properties of Epoxy / Glass fiber Treated with Ultraviolet Rays)

  • 이백수;이덕출
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권2호
    • /
    • pp.86-91
    • /
    • 1999
  • In order to analyse the degradation process of epoxy/glass fiber for outdoor condition, FRP laminate was exposed to the wavelength of ultraviolet rays and evaluated by comparing contact angle, surface resistivity, surface potential decay, and ESCA spectrum respectively. As irradiation energy are increased, the surface properties were steeply decreased in the range of 300[nm]. But the measured values within the scope of400[nm]∼440[nm] showed a increase as compared with the untreated ones. Also, fromthe result of ESCA spectrum, it was confirmed plenty of oxygen groups on the spot showing the maximum decrease of surface properties and the existence of ether groups on the surface of coloring phase. We can conclude that the degradation phenomena on the surface of epoxy composites are dominated by the induction of ester and carboxyl groups.

  • PDF

플라즈마처리에 따른 에폭시 복합재료의 표면특성 (Surface Properties of Epoxy Composites by Plasma Treatment)

  • 임경범;이백수;이덕출
    • 한국전기전자재료학회논문지
    • /
    • 제14권10호
    • /
    • pp.821-827
    • /
    • 2001
  • In this study performed to identify a degradation mechanism in macromolecular insulating material, the contact angel, surface potential decay, surface resistivity, and XPS analysis were compared after exposure of FRP laminate to plasma discharge. In the case of contact angle, the surface of specimen untreated showed weak hydrophobic property of 73。. However, the contact angle was decreased to 20。in the plasma-treated specimen. In the case of chemical changes arising form plasma treatment, carboxl radicals were generated mainly in the surface treated, which was rapidly changed to the hydrophilic one. In the corona potential decay study to determine the electrical changes of the surface, positive charges were rapidly decreased when compared with negative charges, leading to negative property in the surface of specimen not treated. However, in the case of the hydrophilic surface, lots of carboxl radicals acting as positive polarity were generated, resulting in positive surface. Owing to such positive surface, charges of negative polarity applied were rapidly decreased.

  • PDF