• Title/Summary/Keyword: FOV

Search Result 340, Processing Time 0.034 seconds

Alignment of transmitters in indoor visible light communication for flat channel characteristics

  • Curuk, Selva Muratoglu
    • ETRI Journal
    • /
    • v.44 no.1
    • /
    • pp.125-134
    • /
    • 2022
  • Visible light communication (VLC) systems incorporate ambient lighting and wireless data transmission, and the experienced channel in indoor VLC is a major topic that should be examined for reliable communication. In this study, it is realized that multiple transmitters in classical alignment are the forceful factors for channel characteristics. In the frequency band, fluctuations with sudden drops are observed, where the fluctuation shape is related to the source layout and receiver location. These varying frequency-selective channels need solutions, especially for mobile users, because sustained channel estimation and equalization are necessary as the receiver changes its location. It is proven that using light-emitting diodes (LEDs) with highly directional beams as sources or using a detector with a narrow field of view (FOV) in the receiver may help partially alleviate the problem; the frequency selectivity of the channel reduces in some regions of the room. For flat fading channel characteristics all over the room, LEDs should be aligned in hexagonal cellular structure, and detector FOV should be arranged according to the cell dimension outcomes.

Learning Spatio-Temporal Topology of a Multiple Cameras Network by Tracking Human Movement (사람의 움직임 추적에 근거한 다중 카메라의 시공간 위상 학습)

  • Nam, Yun-Young;Ryu, Jung-Hun;Choi, Yoo-Joo;Cho, We-Duke
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.13 no.7
    • /
    • pp.488-498
    • /
    • 2007
  • This paper presents a novel approach for representing the spatio-temporal topology of the camera network with overlapping and non-overlapping fields of view (FOVs) in Ubiquitous Smart Space (USS). The topology is determined by tracking moving objects and establishing object correspondence across multiple cameras. To track people successfully in multiple camera views, we used the Merge-Split (MS) approach for object occlusion in a single camera and the grid-based approach for extracting the accurate object feature. In addition, we considered the appearance of people and the transition time between entry and exit zones for tracking objects across blind regions of multiple cameras with non-overlapping FOVs. The main contribution of this paper is to estimate transition times between various entry and exit zones, and to graphically represent the camera topology as an undirected weighted graph using the transition probabilities.

A Coaxial and Off-axial Integrated Three-mirror Optical System with High Resolution and Large Field of View

  • Chen, Zhe;Zhu, Junqing;Peng, Jiantao;Zhang, Xingxiang;Ren, Jianyue
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.1
    • /
    • pp.94-100
    • /
    • 2016
  • A novel optical design for high resolution, large field of view (FOV) and multispectral remote sensing is presented. An f/7.3 Korsch and two f/17.9 Cook three-mirror optical systems are integrated by sharing the primary and secondary mirrors, bias of the FOV, decentering of the apertures and reasonable structure arrangement. The aperture stop of the Korsch system is located on the primary mirror, while those of the Cook systems are on the exit pupils. High resolution image with spectral coverage from visible to near-infrared (NIR) can be acquired through the Korsch system with a focal length of 14 m, while wide-field imaging is accomplished by the two Cook systems whose focal lengths are both 13.24 m. The full FOV is 4°×0.13°, a coverage width of 34.9 km at the altitude of 500 km can then be acquired by push-broom imaging. To facilitate controlling the stray light, the intermediate images and the real exit pupils are spatially available. After optimization, a near diffraction-limited performance and a compact optical package are achieved. The sharing of the on-axis primary and secondary mirrors reduces the cost of fabrication, test, and manufacture effectively. Besides, the two tertiary mirrors of the Cook systems possess the same parameters, further cutting down the cost.

Dose estimation of cone-beam computed tomography in children using personal computer-based Monte Carlo software (PCXMC 소프트웨어를 이용한 소아에서의 CBCT 환자선량 평가)

  • Kim, Eun-Kyung
    • The Journal of the Korean dental association
    • /
    • v.58 no.7
    • /
    • pp.388-397
    • /
    • 2020
  • Objective: The purpose of the study was to calculate the effective and absorbed organ doses of cone-beam computed tomography (CBCT) in pediatric patient using personal computer-based Monte Carlo (PCXMC) software and to compare them with those measured using thermoluminescent dosimeters (TLDs) and anthropomorphic phantom. Materials and Methods: Alphard VEGA CBCT scanner was used for this study. A large field of view (FOV) (20.0 cm × 17.9 cm) was selected because it is a commonly used FOV for orthodontic analyses in pediatric patients. Ionization chamber of dose-area product (DAP) meter was located at the tube side of CBCT scanner. With the clinical exposure settings for a 10-year-old patient, DAP value was measured at the scout and main projection of CBCT. Effective and absorbed organ doses of CBCT at scout and main projection were calculated using PCXMC and PCXMCRotation software respectively. Effective dose and absorbed organ doses were compared with those obtained by TLDs and a 10-year-old child anthropomorphic phantom at the same exposure settings. Results: The effective dose of CBCT calculated by PCXMC software was 292.6 μSv, and that measured using TLD and anthropomorphic phantom was 292.5 μSv. The absorbed doses at the organs largely contributing to effective dose showed the small differences between two methods within the range from -18% to 20%. Conclusion: PCXMC software might be used as an alternative to the TLD measurement method for the effective and absorbed organ dose estimation in CBCT of large FOV in pediatric patients.

  • PDF

Simulation of Spinning Concentric Annular Ring Reticle Seeker and IRCCM using Correlation Coefficient (회전 동심원 레티클 탐색기의 시뮬레이션 및 상관계수를 이용한 반대응기법)

  • 홍현기;장성갑;두경수;최종수
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.5A
    • /
    • pp.763-771
    • /
    • 2000
  • Reticle systems, which are widely used in infrared (IR) missile seekers, are considered to be the classical approach for estimating the position of a target in the field of view (FOV). This paper presents an effective simulation tool that gives tracking results of the concentric annular ring reticle seeker. We construct the concentric annular ring reticle seeker on Matlab-Simulink for a dynamic simulation. Our simulation model provides tracking results in various cases, and is applicable to the study of the development of the advanced seekers. While false targets such as flares are presented in the FOV, simulation results show that the existing seeker cannot determine a precise target location. In order to decrease the susceptibility to countermeasures such as flares, we propose an efficient counter-countermeasure using the correlated relationship of modulated signals and the references. We have ascertained that the reticle seeker using our technique make more effective target tracking than previous seekers.

  • PDF

Parameters Affecting India Ink Artifacts on Opposed-Phase MR Images

  • Kim, Bo Ra;Ha, Dong-Ho
    • Investigative Magnetic Resonance Imaging
    • /
    • v.23 no.4
    • /
    • pp.341-350
    • /
    • 2019
  • Purpose: To determine the MR parameters affecting India ink artifacts on opposed-phase chemical shift magnetic resonance (MR) imaging. Materials and Methods: The use of a female Sprague-Dawley rat was approved by our Institutional Animal Care and Use Committee. Using an iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL) images, which is a modified Dixon method, axial opposed-phase images of the abdominal cavity were obtained with different MR parameters: series 1, different repetition times (TRs; 400, 2000, and 4000 ms); series 2, different echo times (TEs; 10, 50, and 100 ms); series 3, different field of views (FOVs; 6, 8, 16, and 24 cm); series 4, different echo train lengths (ETLs; 2, 4, and 8); series 5, different bandwidths (25, 50, and 85); and series 6, different slice thicknesses (1, 2, 4, 8, and 16 mm). Artifacts on opposed images obtained with different parameters were compared subjectively by two radiologists. For objective analysis, the thickness of the artifact was measured. Spearman's correlation between altered MR parameters and thicknesses of India ink artifact was obtained via objective analysis. Results: India ink artifact was increasingly apparent using shorter TE, larger FOV and ETL, and thicker slices upon subjective analysis. The objective analysis revealed a strong negative correlation between the thickness of the artifact and TE (r = -0.870, P < 0.01); however, strong positive correlations were found between FOV (r = 0.854, P < 0.01) and slice thickness (r = 0.971, P < 0.01). Conclusion: India ink artifact was thicker with shorter TE, larger FOV, and larger slice thickness.

An implementation of 2D/3D Complex Optical System and its Algorithm for High Speed, Precision Solder Paste Vision Inspection (솔더 페이스트의 고속, 고정밀 검사를 위한 이차원/삼차원 복합 광학계 및 알고리즘 구현)

  • 조상현;최흥문
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.41 no.3
    • /
    • pp.139-146
    • /
    • 2004
  • A 2D/3D complex optical system and its vision inspection algerian is proposed and implemented as a single probe system for high speed, precise vision inspection of the solder pastes. One pass un length labeling algorithm is proposed instead of the conventional two pass labeling algorithm for fast extraction of the 2D shape of the solder paste image from the recent line-scan camera as well as the conventional area-scan camera, and the optical probe path generation is also proposed for the efficient 2D/3D inspection. The Moire interferometry-based phase shift algerian and its optical system implementation is introduced, instead of the conventional laser slit-beam method, for the high precision 3D vision inspection. All of the time-critical algorithms are MMX SIMD parallel-coded for further speedup. The proposed system is implemented for simultaneous 2D/3D inspection of 10mm${\times}$10mm FOV with resolutions of 10 ${\mu}{\textrm}{m}$ for both x, y axis and 1 ${\mu}{\textrm}{m}$ for z axis. Experiments conducted on several nBs show that the 2D/3D inspection of an FOV, excluding an image capturing, results in high speed of about 0.011sec/0.01sec, respectively, after image capturing, with $\pm$1${\mu}{\textrm}{m}$ height accuracy.

LED lighting control system using the variable FOV according to movements of stage actors based on multi sensor (멀티센서기반 무대배우 이동에 따른 FOV가변형 LED조명 제어 시스템)

  • Koo, EunJa;Cha, Jaesang;Kim, Daeho;Park, Myungsook
    • Journal of Satellite, Information and Communications
    • /
    • v.7 no.3
    • /
    • pp.16-21
    • /
    • 2012
  • Recently, an importance of culture industry has been emphasized through an increased income level, spare time and changed values of modern people. And demands of the performance, arts, exhibit are steadily being increased. However the stage equipment depends on foreign manufactures on account of the inactive domestic technical skills. Especially in the lighting direction part, it is essential to control the lighting source and detect the moving line of actors but it generally uses the manual control type and realization of actor's moving line regardless of existing IT-based technologies. Also the system operation of existing sensor-based tracking and detecting technologies depends on the main lighting source of the stage. Therefore, this paper proposed LED lighting control system using the variable FOV and multi sensor-based tracking algorithm, which are possible to efficiently track the stage actors and direct the stage lights. Also we demonstrated the practicality and possibility of realization through the integrated experiment of the proposed system and implementation of the salient hardware, software. Additionally, the usefulness of proposed system was demonstrated using performance simulations and actual measurements of implemented sensor output.

Design of UWB/WiFi Module based Wireless Transmission for Endoscopic Camera (UWB/WiFi 모듈 기반의 내시경 카메라용 무선전송 설계)

  • Shim, Dongha;Lee, Jaegon;Yi, Jaeson;Cha, Jaesang;Kang, Mingoo
    • Journal of Internet Computing and Services
    • /
    • v.16 no.1
    • /
    • pp.1-8
    • /
    • 2015
  • Ultra-wide-angle wireless endoscopes are demonstrated in this paper. The endoscope is composed of an ultra-wide-angle camera module and wireless transmission module. A lens unit with the ultra-wide FOV of 162 degrees is designed and manufactured. The lens, image sensor, and camera processor unit are packaged together in a $3{\times}3{\times}9-cm3$ case. The wireless transmission modules are implemented based on UWB- and WiFi-based platform, respectively. The UWB-based module can transmit HD video to a computer in resolution of $2048{\times}1536$ (QXGA) and the frame rate of 15 fps in MJPEG compression mode. The maximum data transfer rate reaches 41.2 Mbps. The FOV and the resolution of the endoscope is comparable to a medical-grade endoscope. The FOV and resolution is ~3X and 16X higher than that of a commercial high-performance WiFi endoscope, respectively. The WiFi-based module streams out video to a smart device with th maximum date transfer rate of 1.5 Mbps at the resolution of $640{\times}480$ (VGA) and the frame rate of 30 fps in MJPEG compression mode. The implemented components show the feasibility of cheap medical-grade wireless electronic endoscopes, which can be effectively used in u-healthcare, emergency treatment, home-healthcare, remote diagnosis, etc.