• 제목/요약/키워드: FOV

검색결과 340건 처리시간 0.024초

홉필드 네트워크를 이용한 FOV 분할 (Partitioning of Field of View by Using Hopfield Network)

  • 차영엽;최범식
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집A
    • /
    • pp.667-672
    • /
    • 2001
  • An optimization approach is used to partition the field of view. A cost function is defined to represent the constraints on the solution, which is then mapped onto a two-dimensional Hopfield neural network for minimization. Each neuron in the network represents a possible match between a field of view and one or multiple objects. Partition is achieved by initializing each neuron that represents a possible match and then allowing the network to settle down into a stable state. The network uses the initial inputs and the compatibility measures between a field of view and one or multiple objects to find a stable state.

  • PDF

Application of Transfer Insensitive Labeling Technique (TILT) in Ischemic Cerebrovascular Diseases

  • 이승구;김동익;김상흠;김시연;인연권
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2001년도 제6차 학술대회 초록집
    • /
    • pp.169-169
    • /
    • 2001
  • Purpose: To assess the clinical usefulness of Transfer Insensitive Labeling Technique (TILT) in t evaluation of ischemic cerebrovascular disease. Method: Arterial spin labeling (ASL) is a method of perfusion weighted imaging usin endogenous water as a tracer. To avoid MT-related artifacts, which is common in usual A technique, a transfer insensitive labeling technique (TILT) was used, which globall manipulate macromolecular spins in the same way by both labeling and reference preparatio while free water is labeled in one case and left unchanged in the other. Philips Interal 1.5 T system was used. 40cm FOV and 32 repeated measurements were done because of the wea perfusion signal. 5 slices of supratentorial brain were obtained in 5 patients {MCA infar (n=3), moyamoya disease (n=2)}. We simultaneously obtained contrast enhanced T2*-weighted perfusion MRI and correlate to TILT images.

  • PDF

Diffusion Weighted MR Imaging of Spinal Cord: Preliminary Report

  • 인연권;이승구;김상흠;김시연;김동익
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2001년도 제6차 학술대회 초록집
    • /
    • pp.166-166
    • /
    • 2001
  • 목적: 척수의 질환에 대한 확산강조영상 소견에 대하여 알아본다. 대상 및 방법: 임상적으로 진단된 척수질환 환자 8명을 (acute transverse myelitis (n=3), spinal dural AV fistula (n=2), multiple sclerosis (n=1), spinal cord tumor (n=2)) 대상으로 하였다. 영상은 Philips Intera 1.5 T system을 이용하였고, multishot spin echo EPI 펄스열 및 EKG gating을 이용하여 영상을 얻었다. 3R-R 간격으로 영상을 얻었으며 TE=72msec, FOV=25cm, 256 matrix, 5mm thickness, b value=400으로 영상매개변수를 정하였다. 척수 중심으로 3개의 절편을 얻었으며 T2 강조 영상과 겉보기확산계수 영상을 같이 구하였다.

  • PDF

소아의 경직장 영상을 위한 two-turn 표면형 코일과 안장 코일의 비교

  • 김은주;김민정;김대홍;서진석;김명준;김동익;정은기
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2001년도 제6차 학술대회 초록집
    • /
    • pp.146-146
    • /
    • 2001
  • 목적: 해상도가 우수한 경직장 영상을 위한 소아용 two-turn 표면형 수신 코일, 안장 수신 코일을 제작하여 이를 이용하여 얻은 고양이의 경직장 영상을 비교한다. 대상 및 방법: 지금까지 소아의 경직장 영상은 주로 초음파를 이용하여 얻었으나 해상도가 떨어지며 아직까지 소아용 탐촉자는 개발되지 않았다. 소아의 항문직장 기형의 진단을 위해서는 해상도가 우수한 영상이 필요하고, 이를 위해 소아용 직장 RF 코일로 원주형 two-turn 표면형 코일, 안장 코일을 제작하였다. 크기는 직경 7mm, 길이 6cm와, 직경 10mm, 길이 l0cm 하였고, 코일의 구리선 바깥으로는 두께 1mm의 테프론 tube로 감쌌다. 균일한 시험 시료(phantom)로 마요네즈를 이용하여 T1 강조 영상(Spin echo TR/TE= 500/11 msec, FOV=12cm, 영상행렬 256$\times$256)을 얻어서 신호 강도의 profile을 얻는다. 이를 Mathematica를 이용하여 구한 RF 자기장 세기의 분포와 비교했다. 두 종류의 코일을 각각 사용하여 얻은 고양이 항문 괄약근 영상에서 외부 괄약근, 내부 괄약근 등을 구분, 비교하였다.

  • PDF

Reperfusion Hyperemia Demonstrated on Perfusion MRI: It′s Relationship with Programmed Cell Death

  • 이승구;김동익;김상흠;김시연;인연권
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2001년도 제6차 학술대회 초록집
    • /
    • pp.170-170
    • /
    • 2001
  • Purpose: To evaluate the relationship between reperfusion hyperemia in reversible cerebral ischem and the degree of programmed cell death. Method: We produced the animal models of reversible cerebral ischemia in 10 cats by mean of middle cerebral artery (MCA) occlusion with transorbital approach. MCA was occluded b microvascular clamp for an hour. MR imaging was performed at 0, 1, 2 days after ischemi and reperfusion. Perfusion (PWI) [Contrast enhanced GRE EPI, TR/TE= 1500/40, 40 Phases, 128 matrix, 12 cm FOV] and diffusion (DWI) (SE EPI, b=0, 500, 1000) weighted images were obtained using Philips Intera 1.57 system. rCBV and ADC maps were calculated wi IDL based postprocessing program. Tissue slices were obtained after the last MR imagin TUNEL, Calbin and Acid-Fuscin staining were done for corresponding slices as MR imagin We investigated the differences of degree of apoptosis in the area of reperfusion hyperemia.

  • PDF

스티칭 영상의 객관적 영상화질의 평가 방법 (Objective Quality Assessment for Stitched Image and Video)

  • 미어 사데크 빌라흐;타이 탄 투안;안희준
    • 한국방송∙미디어공학회:학술대회논문집
    • /
    • 한국방송∙미디어공학회 2017년도 추계학술대회
    • /
    • pp.218-220
    • /
    • 2017
  • Recently, stitching techniques are used for obtaining wide FOV, e.g., panorama contents, from normal cameras. Despite many proposed algorithms, the no objective quality evaluation method is developed, so the comparison of algorithms are performed only in subjective way. The paper proposes a 'Delaunay-triangulation based objective assessment method' for evaluating the geometric and photometric distortions of stitched or warped images. The reference and target images are segmented by Delaunay-triangulation based on matched points between two images, the average Euclidian distance is used for geometric distortion measure, and the average or histogram of PSNR for photometric measure. We shows preliminary results with several test images and stitching methods for demonstrate the benefits and application.

  • PDF

Seoul National University Camera II (SNUCAM-II) : The New SED Camera for Lee Sang Gak Telescope (LSGT)

  • Choi, Changsu;Im, Myungshin
    • 천문학회보
    • /
    • 제42권1호
    • /
    • pp.35.1-35.1
    • /
    • 2017
  • We present the characteristics and the performance of the new CCD camera system, SNUCAM-II (Seoul National University CAMera system II) that was installed on the Lee Sang Gak Telescope (LSGT) at the Siding Spring Observatory Australia in 2016. SNUCAM-II consists of a deep depletion chip covering a wide wavelength from $0.3{\mu}m$ to $1.1{\mu}m$ with high sensitivity (QE at 90%). It is equipped with SDSS ugriz filters and 13 medium band width (50nm) filters. On LSGT, SNUCAM-II covers $15.7{\times}15.7arcmin$ FOV at pixel scale of 0.92 arcsec and a limiting magnitude of g = 19.91 AB mag at $5{\sigma}$ with 180s exposure time. SNUCAM-II will enable us to study Spectral Energy Distributions (SEDs) of diverse objects from extragalactic sources to solar objects in the southern hemisphere for research and education activities.

  • PDF

3D 카메라 기반 직업성 근골격계 부담 작업 모니터링 장치 (A On-site Monitoring Device of Work-related Musculoskeletal Disorder Risk Based on 3D-Camera)

  • 노병국
    • 한국안전학회지
    • /
    • 제30권6호
    • /
    • pp.110-116
    • /
    • 2015
  • A 3D camera-based on-site work-related musculoskeletal disorder risk assessment(WMDs) tool has been developed. The device consists of Kinect a 3D camera manufactured by Microsoft, a servo-motor, and a mobile robot. To complement inherent narrow field of view(FOV) of Kinect, Kinect is rotated according to PID servo-control algorithm by a servo-motor attached underneath, to track movement of a subject, producing skeleton-based motion data. With servo-control, full 360 degrees tracking of a test subject is possible by single Kinect. It was found from experimental tests that the proposed device can be successfully employed for on-site WMDs risk assessing tool.

확산텐서영상에서 확산경사자장의 방향수에 따른 FA값 및 FA의 표준편차와의 상관 관계

  • 이영주;황문정;배성진;장용민;우성구;서수지
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2003년도 제8차 학술대회 초록집
    • /
    • pp.33-33
    • /
    • 2003
  • 목적: 확산텐서영상 획득시 확산경사자장의 방향수와 FA값, 그리고 FA값의 표준편차와의 상관관계를 조사해 보고자 하였다. 대상 및 방법: 3T MR scanner에서 정상성인 10명(남자 5명, 여자 5명)을 대상으로 걸어주는 확산강조 경사자장의 수(N = 6, 11, 23, 35, 47)를 증가시키며 확산텐서영상을 획득하였다. 획득된 영상들로부터 FA map을 만들고 주요 뇌구조물(frontal GM, putamen, posterior limb of internal capsule, thalamus 등)에 관심영역을 설정하여 FA값을 측정하였으며 그 FA값의 표준편차(sd) 를 계산하였다. 이때 사용한 펄스열은 Stejskal-Tanner type의 확산강조 경사자장이 포함된 single-shot SE EPI를 사용하였으며 영상획득시 사용한 피라미터는 다음과 같다. TR/TE=8000ms/71ms, Thickness/spacing=5/2mm, FOV=240mm, Matrix=$128{\times}128$, NEX= 1, b value=1000s/$\textrm{mm}^2$.

  • PDF

CCD-based EPID and Frame Averaging Technique

  • Kim, Ho-Kyung;Cho, Gyu-Seong;Chung, Yong-Hyun;Ahn, Seong-Kyu;Lee, Hyung-Koo;Kim, Hoi-Nam;Yoon, Sei-Chul
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.297-298
    • /
    • 1998
  • Prototype portal imaging device (EPID) based on CCD camera, which has a $20\times20cm^2$ field of view (FOV), has been developed and then tested by acquiring phantom images for 6 MV x-ray beam. While, among the captured images, each frame suffered notorious quantum noise, the frame averaging largely enhanced the image quality against quantum noise. Over 60 frames averaging, the signal-to-noise ratio (SNR) was increased by $\sim20$ times and contrast was increased about 2 times in the skull-region of the acquired head-phantom image.

  • PDF