• Title/Summary/Keyword: FORCE SENSOR

Search Result 1,229, Processing Time 0.031 seconds

Experimental Research for Traction force Sensor Development on Drawing Exercise Medical Instrument (재활 및 교정을 위한 견인운동치료기의 견인측정센서 개발에 관한 실험적 연구)

  • Lee, Sang-sik;Park, Won-yeop;Lee, Choong-ho
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.2 no.2
    • /
    • pp.3-8
    • /
    • 2009
  • The traction system has been mainly used for rehabilitation and correction of patients with spine or gait diseases in orthopedics or at home. Some problems could occur in human body when patients forced their training using the traction system. So it needs to measure a traction force and control the training time. However, most of products on market have no sensor measuring traction force. Thus we designed and made a sensor detecting traction force using strain gauge, amplifier for transition to output signal and experiment devices for performance test. We carried out experiment of a sensor detecting a traction force and measured electric responses of it with respect to traction loads. Maximum error was within about 1% for experiments in static condition and the average error was about 0.7% for experiments in dynamic condition. We concluded that it is possible to use the developed sensor for measurement of traction force since the maximum output variation of a sensor detecting a traction force was about 0.3% in $0^{\circ}C-60^{\circ}C$ temperature condition.

  • PDF

A Study on Functional Characteristics of Electrolarynx "Evada" Using Force Sensing Resistor(FSR) Sensor (Force Sensing Resistor(FSR) Sensor를 이용한 전기인공후두 "Evada"의 기능적 특성에 대한 연구)

  • 박용재;최홍식;이주형;이성민;김광문
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.9 no.1
    • /
    • pp.11-16
    • /
    • 1998
  • Background and Objectives : Electrolarynx has been used as one of the methods of rehabilitation for the laryngectomees. Previous electrolarynx could not alter frequency and intensity simultaneously. This institute developed an electrolarynx named "Evada" using FSR(force sensing resistor) sensor, which can control the frequency(and/or intensity) simultaneously. This study was performed for the normal control and laryngectomees with three types of electrolarynx (Evada, Servox-inton, Nu-vois) to reveal functional characteristics of Evada Materials and Methods : five laryngectomees and five normal adults were made to express there sentences(discriptive sentence, "You stay here" ; question sentence, "You stay here?" ; exclamation sentence, "You!! stay here!"), using three types of electrolarynx. Frequency change and intensity change from first and last vowel was calculated in three sentences and analyzed statistically by paired T-test. Results : The frequency change in the question sentence and exclamation sentence was more prominent in Evada than in Servox-inton and Nu-vois. The intensity change in the question sentence and exclamation sentence was also more prominent in Evada than in Servox-inton and Nu-vois. Conclusions : Evada could control frequency and intensity simultaneously and control degree of frequency(and/or intensity) according to the pressing force into the button. Evada could adjust continuously frequency and intensity during conversation. So, Evada is better in producing intonation and contrastive stress than Nu-vois and Servox-inton.

  • PDF

Design and Fabrication of 6-Component Forces and Moments Sensor Using a Column Structure (원기둥을 이용한 6축 힘/모멘트 센서의 설계 및 제작)

  • Shin, Hong-Ho;Kim, Jong-Ho;Park, Yon-Kyu;Joo, Jin-Won;Kang, Dae-Im
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.7
    • /
    • pp.1288-1295
    • /
    • 2002
  • The column-type sensing element in building and mechanical construction parts was designed as three forces and three moments sensor by attaching strain gages approximately. Compared to conventional multi-component sensor, the designed sensor has high stiffness and low cost. The radius of the column was designed analytically and compared with finite element analysis. The interference errors between components were minimized by using addition and subtraction procedure of signals. The fabricated sensor was tested by using a deadweight force standard machine and a six-component force calibration machine. The calibration results showed that the 6-component forces and moments sensor had interference error less than 7.3 % between $F_x$ and $M_x$ components, and 5.0 % in case of other components.

Capacitive force sensor

  • Miyazawa, S.;Usui, Y.;Suzuki, M.;Baba, S.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1994.10a
    • /
    • pp.611-615
    • /
    • 1994
  • In this paper, the sensitivity, linearity and temperature drift characteristics of various capacitive force sensors are evaluated and compared using new experimental methods. In particular, two designs were employed to reduce temperature drift. Both types of sensor use high-sensitivity Al coated PET film, and their externals are miniaturized. The first has a layered design consisting of two dielectric substances with different temperature characteristics. The prototype of this design had a temperature drift of only 0.1% of the sensor's capacity in the 20-80.deg. C range. The second type uses both a dummy sensor ind an active sensor with the same characteristics. The temperature drift of the prototype was one-fifth the temperature drift of a single sensor.

  • PDF

Development of a Tactile Sensor Array with Flexible Structure Using Piezoelectric Film

  • Yu, Kee-Ho;Kwon, Tae-Gyu;Yun, Myung-Jong;Lee, Seong-Cheol
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.10
    • /
    • pp.1222-1228
    • /
    • 2002
  • This research is the development of a flexible tactile sensor array for service robots using PVDF (polyvinylidene fluoride) film for the detection of a contact state in real time. The prototype of the tactile sensor which has 8${\times}$8 array using PVDF film was fabricated. In the fabrication procedure, the electrode patterns and the common electrode of the thin conductive tape were attached to both sides of the 281$\mu\textrm{m}$ thickness PVDF film using conductive adhesive. The sensor was covered with polyester film for insulation and attached to the rubber base for a stable structure. The proposed fabrication method is simple and easy to make the sensor. The sensor has the advantages in the implementing for practical applications because its structure is flexible and the shape of the each tactile element can be designed arbitrarily. The signals of a contact force to the tactile sensor were sensed and processed in the DSP system in which the signals are digitized and filtered. Finally, the signals were integrated for taking the force profile. The processed signals of the output of the sensor were visualized in a personal computer, and the shape and force distribution of the contact object were obtained. The reasonable performance for the detection of the contact state was verified through the sensing examples.

Reliability and Validity Study of Inertial Sensor-Based Application for Static Balance Measurement

  • Park, Young Jae;Jang, Ho Young;Kim, Kwon Hoi;Hwang, Dong Ki;Lee, Suk Min
    • Physical Therapy Rehabilitation Science
    • /
    • v.11 no.3
    • /
    • pp.311-320
    • /
    • 2022
  • Objective: To investigate the reliability and validity of static balance measurements using an acceleration sensor and a gyroscope sensor in smart phone inertial sensors. Design: Equivalent control group pretest-posttest. Methods: Subjects were forty five healthy adults aged twenty to fifty-years-old who had no disease that could affect the experiment. After pre-test, all participants wore a waist band with smart phone, and conducted six static balance measurements on the force plate twice for 35 seconds each. To investigate the test-retest reliability of both smart phone inertial sensors, we compared the intra-correlation coefficient (ICC 3, 1) between primary and secondary measurements with the calculated root mean scale-total data. To determine the validity of the two sensors, it was measured simultaneously with force plate, and the comparision was done by Pearson's correlation. Results: The test-retest reliability showed excellent correlation for acceleration sensor, and it also showed excellent to good correlation for gyroscope sensor(p<0.05). The concurrent validity of smartphone inertial sensors showed a mostly poor to fair correlation for tandem-stance and one-leg-stance (p<0.05) and unacceptable correlation for the other postures (p>0.05). The gyroscope sensor showed a fair correlation for most of the RMS-Total data, and the other data also showed poor to fair correlation (p<0.05). Conclusions: The result indicates that both acceleration sensor and gyroscope sensor has good reliability, and that compared to force plate, acceleration sensor has unacceptable or poor correlation, and gyroscope sensor has mostly fair correlation.