• 제목/요약/키워드: FLUENT simulation

검색결과 317건 처리시간 0.023초

직접 메탄올 연료전지의 전산모사에 관한 연구 (Simulation of direct methanol fuel cells employing computational fluid dynamics)

  • 김영진;오인환;홍성안;김혁년;이태희;하흥용
    • 한국전기화학회:학술대회논문집
    • /
    • 한국전기화학회 2002년도 연료전지심포지움 2002논문집
    • /
    • pp.189-192
    • /
    • 2002
  • An analytical study on BMFCS was carried out by employing the computational fluid dynamics(CFD) method. In this study, the commercial CFD code Fluent(ver. 5.5) was used, and many assumptions were adopted to simplify the situation in the fuel cell. From the simulation, many valuable informations were obtained in terms of distributions of velocity, pressure, temperature, density and current density over the flow field. And thus, it was anticipated that the simulation results were very helpful in developing DMFCs by facilitate optimization of structures of electrodes and flow field of the separator.

  • PDF

Simulation을 통한 미세 PUMP 내에서의 유체흐름 연구 (A simulation study on fluid flowing in micro pump)

  • 김용천;류근걸
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2002년도 추계학술발표논문집
    • /
    • pp.163-166
    • /
    • 2002
  • 21세기에 가장 시급하게 확보되어야 하는 기술은 BT (Biotechnology)와 NT(Nano technology)를 접목시키는 기술이다. 특히, 이들을 종합한 MEMS에 관한 연구는 가장 광범위한 분야에서 활발하게 이루어지고 있어 그 기술적 가치가 점차 중요시되고 있다 본 연구는 Simulation을 통하여 Bio-MEMS기술에서 사용되는 미세Pump 내에서의 유체흐름을 Fluent 프로그램을 사용하여 알아보고자 하였다. 즉, 미세Pump 내로 유체가 흐를 경우, 유체의 압력변화나 온도 변화 및 Model에 따른 유동의 흐름을 관찰하여 미세pump 내에서의 최적의 외부조건과 최적의 Pump모델을 알아보고자 실험하였다. 유동의 흐름을 조사해 본 결과 Chamber의 유무에 따라 압력과 온도의 변화를 관찰할 수 있었다. Chamber가 있는 경우 압력의 변화가 적었고 온도의 변화 또한 적었다. 따라서 Chamber가 있는 Pump가 유체의 흐름에 영향을 적게 줌을 알 수 있었으며 이는 Chamber가 있는 Pump를 설계하는 것이 필요하다고 할 수 있다.

300 mm 웨이퍼 위의 에어로졸 나노 입자의 증착 장비 개발을 위한 수치 해석적 연구 (Numerical Simulation of Deposition Chamber for Aerosol Nanoparticles Upward 300 mm Wafer)

  • 안강호;안진홍;이관수;임광옥;강윤호
    • 반도체디스플레이기술학회지
    • /
    • 제4권1호
    • /
    • pp.49-53
    • /
    • 2005
  • The nanoparticle deposition chamber, which is used for quantum dot semiconductor memory applications, is designed by means of numerical simulation. In this research, the numerical simulations for deposition chamber were performed by commercial software, FLUENT. The deposition of nanoparticles is calculated by diffusion force, thermophoresis and electrophoresis of particles. As a results, when the diffusion force was considered, the most of particles deposited in the wall of deposition chamber. But as considering thermophoresis and electrophoresis of particles, the particles were deposited wafer surface, perfectly.

  • PDF

지열원 히트펌프를 이용한 도로융설시스템의 CFD 성능예측에 관한 기초연구 (A Basic Study on the Performance CFD simulation of Road Snow-melting system by Ground Source Heat Pump)

  • 최덕인;김중현;김진호;황광일
    • 한국지열·수열에너지학회논문집
    • /
    • 제6권2호
    • /
    • pp.23-28
    • /
    • 2010
  • Fluent ver.6.3 is used as CFD(Computational Fluid Dynamics) simulator to predict the performance of snow-melting system by geothermal pipes energy. As the results of this simulation, it is clearly shown that $50^{\circ}C$ of working fluid in to geothermal evaluated as more effect comparing to $45^{\circ}C$ of working fluid. The Surface temperature is come to $5^{\circ}C$ at 1m/s speed and $50^{\circ}C$ temperature of the working fluid.

터널 화재발생시 시뮬레이션 프로그램을 통한 승객대피계획 (A study on the rescue design of passengers for railway tunnel fire accidents by using simulation program)

  • 권순섭;이종선;이관호;권우성
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.1770-1773
    • /
    • 2007
  • Fire accident in tunnel is one of the most critical railway accidents, together with overturning of train by derailment and train crash. Tunnel structures contribute to minimize the cost and time of transport, but in case of railway fire accident occurring bring serious damages of human life caused by narrowness of shelter, poisonous smoke and high temperature raised at the inside of tunnel. For that reason, at the beginning of plan of tunnel, the optimum design for rescue of passengers is needed. For the detail and most suitable design for rescue of passengers, many tunnel designer substituted simulation program for mock examination by its high cost and effort. In this study, simulation program techniques, such as Fluent and Simulex, are applied for verifying the rescue design of passengers reduced the risk when fire accident occurred at tunnel utilizing of case study for planned railway tunnels shows 1,245m length in Iksan-Sili area.

  • PDF

CFD를 이용한 초고층빌딩 누드 엘리베이터의 온열 및 연돌현상에 관한 연구 (A Study on the Thermal Phenomena and Stack Effect of Nude Elevator Shaft of High Rise Building that used CFD)

  • 박정한
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.1059-1064
    • /
    • 2008
  • The present study is to reduce the thermal phenomena and stack effect of nude elevator of the high-rise building used CFD simulation. Since many High-rise buildings used the curtain-wall glass, thermal phenomena and stack effect can easily occur at hot and cold season, respectively. The simulation has been conducted and verified for the effects of the amount of suppling air to the environment of the inside nude elevator shaft. The results of simulations show that the problems due to the thermal and stack effect will be reduced by enforced ventilation or natural ventilation and those will be presented by temperature and velocity profiles and pressure differences.

  • PDF

Numerical Simulation of Thermal Fluctuation of Hot and Cold Fluids Mixing in a Tee Junction

  • Gao, Kai;Lu, Tao
    • International Journal of Advanced Culture Technology
    • /
    • 제3권2호
    • /
    • pp.171-178
    • /
    • 2015
  • In this work, mixing processes of hot and cold fluids of three different jet types are predicted by large-eddy simulation (LES) on FLUENT platform. Temperature at different positions of internal wall and mixing conditions of T-junctions at different times are obtained, then the simulated normalized mean and root-mean square (RMS) temperature, temperature contour and velocity vector of every case are compared. The results indicate that, the mixing regions in the tee junction is related to the jet type, and temperature fluctuations on the pipe wall in the type of the deflecting jet is the least.

CFD를 이용한 Window Defrosting 평가 (The evaluative study of window defrost using Computational Fluid Dynamics)

  • 이인수;임효남;최재웅
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2011년 춘계학술대회논문집
    • /
    • pp.179-182
    • /
    • 2011
  • The purpose of this study is to evaluate a defrost model for the possibility of defrosting on wheelhouse window and the heat capacity if defrosting nozzle by using the commercial CFD solver FLUENT. A detailed simulation model has been created which contains the defrosting nozzle, window and the interior/exterior forced convection boundary. In this numerical study, the heat and mass transfer coupled during defrosting and investigated the defrost time for different hot gas temperature, external wind speed and temperature condition.

  • PDF

Y형 세대별 정유량 밸브 개발에서의 CFD의 활용 (CFD for Y-type Constant Flowrate Valve Design)

  • 권우철;이병휘
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2004년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.488-491
    • /
    • 2004
  • Numerical analysis of the three dimensional turbulent flow field in a complex valve shape is carried out to confirm the flow field whether the designed valve shape is good or not. The simulation of the incompressible flow in a constant flowrate control valve is performed by using the commercial code, FLUENT/UNS 6.0. The results of flow field show the designed valve has some problems, therefore these will be good data for new valve design.

  • PDF

평판형 집열기의 지관수에 따른 유동특성에 대한 수치해석 연구 (Numerical Study on the Flow Characteristics of Flat-Plate Solar Collector with Riser Number)

  • 김정배;이동원;백남춘
    • 한국태양에너지학회 논문집
    • /
    • 제27권3호
    • /
    • pp.143-148
    • /
    • 2007
  • It is essential to know the flow characteristics at the risers of Flat-plate solar collector for optimum design. For flat-plate solar collector, it is difficult to experimentally study the effect for the number of riser in the collector for the economic problem. So, this study was performed to show the flow characteristics of flat-plate solar collector with the number of riser using commercial code FLUENT 6.0. The base collector size is chosen with $2\;m^2$ as 1m by 2m in this study, the mass flow rate was estimated 0.04 kg/s using the mass flow rate of 0.02 kg/s per collector area for the certificate test. The number of riser is selected 4, 6, 8, 10, 12, and 14. Through the simulation, the conditions with the risers of 10 or 12 is shown as the optimum design conditions for conventional flat-plate solar collector considering lower pressure drop and more uniformly distributed mass flow rate for higher heat transfer rate without considering heat transfer.