• 제목/요약/키워드: FLOW-3

검색결과 19,613건 처리시간 0.043초

유등천 수원확보 규모와 하류 하천유지유량의 상관성 (Increase of Downstream Minimum Flow Followed by Increase of Water Storage Size in Yudeungcheon Upstream)

  • 노재경;김용국;이재남
    • 농업과학연구
    • /
    • 제37권2호
    • /
    • pp.285-293
    • /
    • 2010
  • To secure instream flow at the Yudeung urban stream reach of Daejeon city in South Korea, Yudeung upstream diversion was designed with total water storage of $59{\times}10^4m^3$, and the upstream Seongol reservoir was planned to raise the bank with various sizes. Downstream streamflows were simulated by considering outflows from upstream diversion and reservoir, and after then flow durations were analyzed and compared with flows of no reservoir condition. In case of no diversion or reservoir upstream, flow durations were $1^{st}$ flow of $84.72m^3/s$, $95^{th}$ flow of $2.10m^3/s$, $185^{th}$ flow of $0.92m^3/s$, $275^{th}$ flow of $0.42m^3/s$, and $355^{th}$ flow of $0.31m^3/s$. In case of upstream diversion, flow durations were $1^{st}$ flow of $94.38m^3/s$, $95^{th}$ flow of $2.96m^3/s$, $185^{th}$ flow of $1.22m^3/s$, $275^{th}$ flow of $0.50m^3/s$, and $355^{th}$ flow of $0.35m^3/s$. The increase flow rates were $0.04m^3/s$ in $355^{th}$ flow, $0.08m^3/s$ in $275^{th}$, and $0.30m^3/s$ in 185th. In case of Seongol reservoir with effective storage capacities of $365{\times}10^4m^3$, $544{\times}10^4m^3$, $750{\times}10^4m^3$, and $992{\times}10^4m^3$, flow durations were $85.5{\sim}83.9m^3/s$ on $1^{st}$ flow, $2.85{\sim}2.57m^3/s$ on $95^{th}$ flow, $1.16{\sim}1.27m^3/s$ on $185^{th}$ flow, $0.64{\sim}0.99m^3/s$ on $275^{th}$ flow, and $0.56{\sim}0.94m^3/s$ on $355^{th}$ flow. The increase flow rates were $0.25{\sim}0.63m^3/s$ in $355^{th}$ flow, $0.22{\sim}0.57m^3/s$ in $275^{th}$, and $0.24{\sim}0.35m^3/s$ in $185^{th}$. The more the sizes of upstream reservoirs increased, the $1^{st}$ and $95^{th}$ flows decreased in which coefficients of determination were 0.92, 0.99, respectively and the $185^{th}$, $275^{th}$, and $355^{th}$ flows increased in which coefficients of determination were 0.93 to 0.99.

흡기3밸브 실린더 헤드의 흡입 정상유동 특성에 관한 연구 (A Study on the Steady Intake Flow Characteristics of the Intake 3-Valve Cylinder Head)

  • 정재우;이기형;김우태
    • 대한기계학회논문집B
    • /
    • 제24권6호
    • /
    • pp.880-885
    • /
    • 2000
  • Flow patterns and steady flow characteristics of an intake 3valve cylinder head are not obviously declared. Thus, in the study, the characteristics and limitation of intake flow coefficient which applied to multi intake valve engine are introduced. The flow coefficient and tumble characteristics are investigated by means of the steady flow test and flow visualization method. As the results, it is found that the intake flow rate is dominated by effective valve open area. In addition, this paper shows that the mass flow rate of intake 3valve engine is greater than that of intake 2valve engine and tumble flow of intake 3valve engine is superior to that of intake 2valve engine.

FLOW-3D 모형을 이용한 용승류 모의 (The Simulation of Upwelling Flow Using FLOW-3D)

  • 오남선;최익창;김대근;정신택
    • 한국해안·해양공학회논문집
    • /
    • 제23권6호
    • /
    • pp.451-457
    • /
    • 2011
  • 최근 용승류가 발생하는 지역에서 대규모 어장이 형성되는 원리를 이용하여 대규모 해양구조물을 건설하여 인공적으로 용승류를 발생시킴으로써 새로운 어장을 조성하는 사업이 일본과 한국에서 진행되고 있다. 이 연구에서는 FLOW-3D 모형을 이용하여 용승류 흐름을 모의하고자 하였다. 또한 FLOW-3D 모형에서 Marker의 이동을 이용하여 영양염의 용승현상을 판단할 수 있는 방법을 모색하고자 하였다. 연구결과 FLOW-3D 모형을 이용하여 용승효과를 사전에 정성적으로 판단하는 것이 가능하였다.

The Equilibrium between Dilatant and Thixotropic Flow Units

  • 방정환;김남정;최상원;김응렬;한상준
    • Bulletin of the Korean Chemical Society
    • /
    • 제17권3호
    • /
    • pp.262-268
    • /
    • 1996
  • Flow properties of all suspensions are controlled by their flow units. The factors effecting on the flow units are the characteristics of the particle itself (surface properties, particle sizes, particle shapes and etc.), the electrostatic interactions among the particles and the influences of the medium in the suspensions. Here, we studied the transition between the flow units with shear rate which can be added to the above factors. For the concentrated starch-water suspensions, by using the Couette type rotational viscometer, we confirmed that at low shear rate, dilatancy is appeared, but it is transformed to thixotropy with increasing shear rate. In order to explain this fact, we derived the following flow equation, representing the transition from dilatancy to thixotropy with shear rate, by assuming the equilibrium between the flow units. f = X1β1s./α1 + 1/(1+Kexp(c0s.2/RT))((1-X1)/α2)sinh-1{(β2)0 s. exp(c2s.2/RT)} + K exp(c0s.2/RT)/(1+K exp(c0s.2/RT))((1-X1)/α3)sinh-1{(β3)0 s. exp(-c3s.2/RT)} By applying this flow equation to the experimental flow curves for the concentrated starch-water suspensions, the flow parameters were obtained. And, by substituting the obtained flow parameters to the flow equation, the theoretical flow curves were reproduced. Also, Ostwald curve was represented by applying the flow equation, and the applicability for stress relaxation was discussed.

3 포트 사각 튜브내에서 ER유체의 유동 가시화 (A Flow Visualization of ER Fluids in 3Port Rectangular Tube)

  • 장성철;염만오;장문제
    • 한국공작기계학회논문집
    • /
    • 제15권2호
    • /
    • pp.30-37
    • /
    • 2006
  • The purpose of this study is to visualize the characteristics of ER fluids as preceding step of developing 3 port ER valves. ER fluids are made with silicone oil and 3 weight fraction starch having hydrous particles. The flow visualization of ER fluids flow is obtained by CCD camera with changing the strength of electric field to ER fluids flow. As the strength of the electric field increases, more clusters in flow are made and these clusters are though to be the reasons of the load flow rate being increased and the outlet flow rate being decreased. The ER Valves and load and outlet flow rate check method are considered to be applied to the fluid power control system.

FLOW-3D를 이용한 교각주변 흐름의 수치해석 (Numerical Analysis of Flow around Bridge Pier using FLOW-3D)

  • 김창성;강준구;여운광
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2005년도 학술발표회 논문집
    • /
    • pp.953-958
    • /
    • 2005
  • 최근 들어 다양한 산업에서 3차원 수치해석을 이용하는 영역이 넓혀지고 있다. 국내에서도 3차원 수치해석을 이용하여 댐이나 정수처리시설 설계 등 수리분야에 적용하였고, 점점 그 이용이 확대되고 있다. 특히 교량 및 수제 등의 수공구조물로 인한 주변 흐름형상은 2차원 해석이 불가능하여 현재 수리모형실험을 통한 해석이 주를 이루고 있다. 이에 본 연구에서는 현재 3차원 수치해석에 많이 이용되는 상용모델인 FLOW-3D를 이용하여 3차원 흐름에 대한 수치해석을 수행하였으며 수리모형 결과와 비교하여 적용성을 검토하였다. 그 결과 모의 및 실험결과 수리모형과 수치모의 결과는 서로 비슷한 흐름양상을 보이고 있었다. 또한 조도계수(Roughness)를 매개변수로 하여 다양한 상태에서의 FLOW-3D의 민감도를 검토하였으나 실제 흐름과는 상이함을 보였다 또한 다양한 난류모형을 적용하여 그 결과를 실제 흐름과 비교해보았다. 그 결과 3차원모형에서는 교각 후면부와 좌, 우측면부에서의 흐름이 실제 수리 모형과는 상이한 결과를 보이는데 이는 FLOW-3D의 벽 경계 및 와류에 대한 난류모델에 따른 수치해석적인 차이로 사료된다.

  • PDF

학습기반의 객체분할과 Optical Flow를 활용한 2D 동영상의 3D 변환 (2D to 3D Conversion Using The Machine Learning-Based Segmentation And Optical Flow)

  • 이상학
    • 한국인터넷방송통신학회논문지
    • /
    • 제11권3호
    • /
    • pp.129-135
    • /
    • 2011
  • 본 논문에서는 2D 동영상을 3D 입체영상으로 변환하기 위해서 머신러닝에 의한 학습기반의 객체분할과 객체의 optical flow를 활용하는 방법을 제안한다. 성공적인 3D 변환을 가능하게 하는 객체분할을 위해서, 객체의 칼라 및 텍스쳐 정보는 학습을 통해 반영하고 움직임이 있는 영역 위주로 객체분할을 수행할 수 있도록 optical flow를 도입한 새로운 에너지함수를 설계하도록 한다. 분할된 객체들에 대해 optical flow 크기에 따른 깊이맵을 추출하여 입체영상에 필요한 좌우 영상을 합성하여 생성하도록 한다. 제안한 기법으로 인해 효과적인 객체분할과 깊이맵을 생성하여 2D 동영상에서 3D 입체동영상으로 변환됨을 실험결과들이 보여준다.

영역기반 윤곽선 기법과 표면 분할 유동모델에 기반한 근위 등속 표면적 기법을 이용한 혈류량 추정 (Blood Flow Rate Estimation using Proximal Isovelocity Surface Area Technique Based on Region-Based Contour Scheme and Surface Subdivision Flow Model)

  • 진경찬;조진호
    • 전자공학회논문지SC
    • /
    • 제38권1호
    • /
    • pp.45-52
    • /
    • 2001
  • PISA 방법은 주로 승모판에서 역류하는 혈류량을 측정하기 위해 사용되고 있다. 이 방법은 PISA isotach의 기하학적 모양에 대한 모델링에 관한 것이다. PISA의 일반적인 유동모델은 isotach의 표면이 수식적으로 반구이거나 비반구임을 가정하여 계산된 것이지만, 본 논문에서는 영역기반방법으로 isotach를 추정한 후, 타원체의 높이에 기초한 실제적인 표면분할 유동모델을 이용하여 유체량을 추정하였다. 제안한 밥법을 평가하기 위해, $30cm^3/sec-60\;cm^3/sec$의 실제 유량을 가지는 동적인 180개의 유동영상에 대해서 기존 방법들과 비교하였다. 실험한 결과, 반구 유동모델의 유체량 평균이 $29\;cm^3/sec$로 실제 유체량 평균보다 35%정도 적게 추정을 하였고, 제안한 방법의 평균은 $45\;cm^3/sec$으로 비반구 유동모델의 평균과 같았고, 유체량 변화파형도 유사한 결과를 가짐을 알 수 있었다.

  • PDF

원심회전차 내부유도장에 관한 수치해석적 연구 (Numerical study on flows within an shrouded centrifugal impeller passage)

  • 김성원;조강래
    • 대한기계학회논문집B
    • /
    • 제20권10호
    • /
    • pp.3272-3281
    • /
    • 1996
  • The flow analysis method which had been developed for the numerical calculation of 3-dimensional, incompressible and turbulent flow within an axial compressor was extended to the flow field within centrifugal impeller. In this method based on the SIMPLE(Semi Implicit Method Pressure Linked Equations) algorithm, the coordinate transformation was adopted and the standard k-.epsilon. model using wall function was used for turbulent flow analysis. The calculated flow fields have agreed very well with measurement results. Especially, 3-dimensional and viscous flow characteristics including secondary flows, jet-wake flow and decreased pressure rise along impeller passage, which can't be predicted by inviscid Q3D calculation were predicted very reasonably.

국내 중소하천에 설치된 아이스하버 어도 내부 흐름 특성 규명 (Investigation for flow characteristics of ice-harbor type fishway installed at mid-sized streams in Korea)

  • 백경오;민병조
    • 한국수자원학회논문집
    • /
    • 제55권1호
    • /
    • pp.33-42
    • /
    • 2022
  • 본 연구에서는 3차원 상용 수치모형 Flow-3D를 활용하여 상류 수위(유입유량) 변동, 격벽의 간격(pool의 길이) 변화, 잠공 유무 등에 따른 아이스 하버 어도 내 흐름 양상을 분석하였다. 수치모의 결과의 적합성을 입증하기 위해 경안천 대곡교 하류에 설치된 실제 어도에서 3차원 초음파 유속계를 사용하여 어도 출구부 단면 유속과 유량을 관측하였다. Flow-3D 모형에는 난류 모듈로 4가지를 선택할 수 있는데, 관측 자료로 검증 결과 RNG 모형이 아이스하버 어도 내 흐름 특성을 가장 잘 재현하였다. 하천의 유량 전량이 어도로만 유입되어 흐른다는 조건에서 수위 변화에 따른 어도 내 유속구조를 모의해 보았다. 그 결과 최저수위에서는 잠입류와 표면류가 혼재하여 발생하였는데, 최저수위에서 약 10 cm 이상만 수위가 상승하여도 모든 pool에서 잠입류가 사라지고 오직 표면류만 발생하였다. 예상과 달리 수위가 조금 상승해도 흐름이 꽤 단순하게 표면류 위주로 발생하였다. 격벽간 간격을 늘려주면 수위가 상승하더라도 잠입류와 표면류가 혼재되어 나타나는 현상이 지속되었다. 그리고 격벽 하단에 잠공이 있는 경우가 없는 경우에 비해 잠입류가 여러 pool에서 생성되는 경향을 보였다. 보다 적극적인 어도 사후 관리로 잠공 폐색을 막아 어도 내 다양한 흐름이 생성될 수 있도록 유도하는 것이 필요해 보인다.