• Title/Summary/Keyword: FLEX

Search Result 446, Processing Time 0.048 seconds

Determination of Heat Treatment Condition for Hot Press Formed Automotive Flex Plate (자동차용 플렉스 플레이트 제조를 위한 핫프레스 포밍 열처리 조건 최적화)

  • Park, I.H.;Lee, M.G.;Kim, S.J.;Jeong, W.C.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2008.10a
    • /
    • pp.186-189
    • /
    • 2008
  • The flex plate, an automotive part which mounts to the automotive engine to transfer torque to transmission, should have considerable hardness and shape accuracy. As a way to produce the flex plate, the hot press forming technology which takes advantages of high formability at elevated temperature, enhanced strength and shape stability was introduced. Therefore, as one of major process parameters the heat treatment condition should be determined to obtain appropriate hardness in the range of manufacturer's specifications. In this study, two heat treatments, austempering and quenching and tempering (QT), were compared as feasible conditions fur the hot press forming of high-carbon tool steel and the hardness and toughness after heat treatments were evaluated. The study showed that both heat treatments resulted in improved hardness but only quenching and tempering showed practicable range of toughness.

  • PDF

Application of Regression Analysis for Quality Control In Suspension Manufacturing

  • Ritthidetch, Thammasak;Masuchun, Ruedee;Chaikla, Amphawan;Julsereewong, Prasit;Tirasesth, Kitti
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.704-709
    • /
    • 2004
  • This paper presents the laser processing to adjust the roll and pitch directions of the flex suspension assembly for hard disk drive production. The adjustment is accomplished using a number of laser beam projections that can be approximated using the regression model of the existing measured roll and pitch directions. Information derived from the analysis can be applied to control the quality of flex suspension assembly. The performances of the proposed technique were observed using the flex suspension assembly plant in Thailand as an illustrative case study. The experimental results are given to support the improving manufacturing yields and some economic benefits of the proposed technique.

  • PDF

Design and Implementation of a High Speed Pager Based on FLEX Protocol (FLEX 방식 고속 무선호출 단말기 설계 및 구현)

  • 오병문;이동원;김영철
    • Proceedings of the IEEK Conference
    • /
    • 2000.11a
    • /
    • pp.205-208
    • /
    • 2000
  • In this paper, we have designed a pager based on the FLEX protocol. The pager consists of a decoder, a MCU, a SPI, and a User interface. The decoder contains the following blocks: synchronizer, de-interleaver, error corrector, packet builder. The decoded data is converted to SPI packets for communication between the MCU and the FLEX decoder. The host MCU is a RISC pipelined architecture, so it processes data at high speed and also sends messages to user interface. We have designed the proposed pager as structural modeling using VHDL language. Then, We simulated and synthesized it using tool of SYNOPSYS corporation.

  • PDF

Prosthetic arm control using muscle signal (생체 근육 신호를 이용한 보철용 팔의 제어)

  • Yoo J.M.;Kim Y.T.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1944-1947
    • /
    • 2005
  • In this paper, the control of a prosthetic arm using the flex sensor signal is described. The flex sensors are attached to the biceps and triceps brchii muscle. The signals are passed a differential amplifier and noise filter. And then the signals are converted to digital data by PCI 6036E ADC. From the data, position and velocity of arm joint are obtained. Also motion of the forearm - flexion and extension, the pronation and supination are abstracted from the data by proposed algorithm. A two D.O.F arm with RC servo-motor is designed for experiment. The arm length is 200 mm, weight is 4.5 N. The rotation angle of elbow joint is $120^{\circ}$. Also the rotation angle of the wrist is $180^{\circ}$. Through the experiment, we verified the possibility of the prosthetic arm control using the flex sensor signal. We will try to improve the control accuracy of the prosthetic arm continuously.

  • PDF

Optical Performance of Bent Polymer Network Liquid Crystal Films Using Plastic Substrates

  • Kuo, Chia-Wei;Lin, Yan-Rung;Wang, Hsing-Lung;Liao, Chi-Chang;Huang, Po-Yu;Shy, Joe-Tsong;Lu, Kevin;Tsai, Afonda;Chang, Rick;Chen, Jerry
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.627-628
    • /
    • 2008
  • We have studied the optical performance of flexible polymer network liquid crystal (PNLC) films at various bending states. Different measurement setups, wide and narrow opening angles of detector, were used to collect scatting light of PNLC films. The optical and dynamic properties of bent PNLC implied the change of LC domains.

  • PDF

Study on the VHDL modeling and Implementation of a FLEX high speed pager decoder (FLEX 방식 고속무선호출 디코더의 VHDL 모델링 및 구현 연구)

  • Park, Jin;Lee, Tae-Won;Kim, Young-Chul
    • Proceedings of the IEEK Conference
    • /
    • 1999.06a
    • /
    • pp.373-376
    • /
    • 1999
  • In tills paper, we design it decoder for the FLEX high speed paging protocol. The decoder that we design consists of a synchronizer, a de-interleaver, a error corrector and a packet builder In the FLEX protocol, a word is coded using HCH algorithm. In this design, we do not use a look-up table in order to decrease a chip area of the BCH decoder. The simulation result shows that the decoder is correctly designed

  • PDF

Arduino-based Flex Sensor Device for Smart Healthcare (아두이노 기반의 구부림센서를 이용한 가상현실 손가락 모델링)

  • Moon, Jae-ung;Cho, Young-bok
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.10a
    • /
    • pp.102-103
    • /
    • 2021
  • With the development of medical IT technology, personalized medical services are increasing in the silver industry era through the development of smart healthcare business. Therefore, in this paper, using various sensors in the Arduino environment, we implemented a finger modeling that can perform joint rehabilitation exercise that can provide personalized smart healthcare services. By measuring the activity of each individual finger joint using an Arduino-based flex sensor, it is intended to be used for personalized rehabilitation exercise in the smart healthcare field in the future.

  • PDF

A Study on Improvement of the low temperature flex resistance test method about high waterproof materials (고기능성 투습방수 소재의 저온굴곡 시험방법 개선 연구)

  • Lee, Minhee;Moon, Sunjeong;Ko, Hyeji;Hong, Seongdon
    • Journal of Korean Society for Quality Management
    • /
    • v.46 no.3
    • /
    • pp.425-440
    • /
    • 2018
  • Purpose: This study is aimed at developing of the flex resistance testing process at low temperature with the waterproof fabric to suit the military environment, and is designed to fit for the purpose of the waterproof materials in order to optimize the test method by finding out matters to improve from existing the test method and through previous studies. Methods: The test method, which has been applied to flex resistance of existing water-repellent materials, was improved and consequently, differentiated test results could be obtained according to the test temperature, sample size, and flexing method. Results: The testing of the total of 8 samples revealed that performance of the military requirement could hardly be met just by presenting the materials or 2~3 layers when the quality criteria for high functional water repellent fabrics were applied. PTFE(Polytetrafluoroethylene) is preferred to PU(Polyurethane) to be used in the extremely low-temperature environment, but durability under the low-temperature environment may be varied depending on film thickness or laminating technique even if the materials of waterproof films are identical. Therefore, in addition to the material or texture, the test method capable of reflecting durability under the low-temperature environment shall be suggested, and the newly designed test method proposed in this study was shown to suggest differentiated quality criteria by the material. Conclusion: The water resistance measurement and the test method following flex resistance with expanded range of flex will enable the differentiable test of the samples according to the number of repetition. This study is meaningful in that it suggests a differentiable test method capable of establishing a basis of deciding suitable material when selecting military goods made of water repellent material by properly improving the test method.

The BioFlex System as a Dynamic Stabilization Device : Does It Preserve Lumbar Motion?

  • Zhang, Ho-Yeol;Park, Jeong-Yoon;Cho, Bo-Young
    • Journal of Korean Neurosurgical Society
    • /
    • v.46 no.5
    • /
    • pp.431-436
    • /
    • 2009
  • Objective : This study examines whether functional motion is present at one or more years after Bioflex System placement. BioFlex System is a flexible rod system which has been used to preserve motion at the area of implantation. There has not been a scientific study showing how much motion is preserved after implantation. Methods : A total of 12 consecutive patients underwent posterior dynamic stabilization using the BioFlex System. Six patients were treated using a L3-4-5 construct and other six patients using a L4-5-S1 construct. Follow-up ranged from 12 to 33 months and standing neutral lateral, extension, flexion and posteroanterior (PA) radiographs were obtained at 3, 6, 9, and 12 months and at more than 12 months postoperatively. Range of motion (ROM), whole lumbar lordosis, and ROMs of motion segments from L2 to S1 were determined. Results : Patients with a L3-4-5 construct demonstrated a decrease in mean ROM for whole lumbar decreased from 40.08 to 30.77. Mean ROM for L3-4 (6.12 to 2.20) and L4-5 (6.55 to 1.67) also decreased after one year. Patients with a L4-5-S1 construct demonstrated L4-5 (8.75 to 2.70) and L5-S1 (9.97 to 3.25) decrease of mean ROM at one year postoperatively. Lumbar lordosis was preservep at both L3-4-5 and L4-5-S1 constructs. Clinical results showed significant improvements in both study groups. Conclusion : The present study provides preliminary information regarding the BioFlex motion preservation system. We conclude that the BioFlex System preserves functional motion to some degree at instrumented levels. However, although total lumbar lordosis was preserved, ROMs at implantation segments were lower than preoperative values.

A Study on the Development of Bleaching efficiency for flex fabrics by Using Ozone Treatment (오존을 이용한 마직물의 표백성 향상에 관한 연구)

  • Lee, Mun-Soo;Song, Kyong-Hun;Kim, Gyoung-A;Song, Bong-Keun;Lee, Rae-Yohn
    • The Journal of Natural Sciences
    • /
    • v.10 no.1
    • /
    • pp.93-102
    • /
    • 1998
  • In order to study on the bleaching efficiency of flex fabrics, ozone which has been produced by an ozone generator, has been contacted with flex fabrics in water at various conditions. The equipments used for the ozone reatment of flex fabrics were the ozone generator and a liquor/ozone contactor. For the study of the bleaching efficiency on flex fabrics, the Hunter's whiteness, tensile strength, microscopic properties of the ozone treated flex fabrics were measured. The concentration of generated ozone was increased, as the voltage increase, flow ratio decrease and oxygen amount increase. The bleaching efficiency of ozone treated fabrics was increased with increasing the net concentration of ozone. The whiteness ozone of treated fabrics was found to be best when treated temperature was $0-15^{\circ}C$ and treated time was 20 min. The tensile strength of treated fabrics decreased as the treating time increased, and as the temperature raised.

  • PDF