• Title/Summary/Keyword: FLD0

Search Result 100, Processing Time 0.024 seconds

Analytical Characteristics of GC/MS and HPLC according to the Concentration Distribution of PAHs (PAHs 농도 분포에 따른 GC/MS와 HPLC의 분석특성에 관한 연구)

  • Hong, Jwa-Ryung;Choi, Kwang-Min
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.3
    • /
    • pp.312-321
    • /
    • 2015
  • Objectives: The purpose of this study was to determine the best method to analyze PAHs at extremely low concentrations. To this end, 16 PAHswere analyzed simultaneously by GC/MS, HPLC/FLD and HPLC/UVD, and the analytical characteristics of HPLC and GC/MS were compared. Methods: This study was conducted by GC/MS and HPLC/FLD/UVD, and evaluated linearity, precision and detection limit. Standard solutions were prepared for 21 samples in the range of $0.00001{\sim}1.0{\mu}g/mL$ and the samples were divided into four groups. All samples were made in three sets and analysis was replicated seven times. Results: Sixteen PAHs could be simultaneously separated by HPLC and GC/MS, and the adequate equipment was HPLC/FLD. The retention times by HPLC were shorter than GC/MS, and HPLC had better separation for most PAHs than GC/MS. The peaks of naphthalene and naphthalene-D8 partially overlapped for GC/MS. HPLC/FLD had a 20-2000 times lower limit of detection than GC/MS and UVD. However FLD was not adequate for analyzing acenaphthylene because it has too low a fluorescence quantum yield to be detected. The precision of HPLC/FLD/UVD and GC/MS showed less than 20% at $0.001{\mu}g/mL$ PAHs and when the concentration was higher, the coefficient of variation was decreased. HPLC/FLD was better for the overall detection of limits. Conclusions: The results indicate that the HPLC/FLD method has good linear range, precision and a detection of limits from $0.00001{\sim}0.0001{\mu}g/mL$ for all 16 PAHs. This study contributes to providing useful data for analysis technology and can be applied to occupational exposure measurement for PAHs in workplaces.

Application of Competitive ELISA Method for Estimation of Urinary Aflatoxin M1 Level (ELISA 방법을 이용한 요중 아플라톡신 M1 측정)

  • Kim, Yong-Dae;Kim, Heon
    • Journal of Life Science
    • /
    • v.23 no.2
    • /
    • pp.306-310
    • /
    • 2013
  • We compared the efficacy of the competitive ELISA method for measuring the level of urinary aflatoxin M1 (AFM1) with that of the HPLC-fluorescence detector (HPLC-FLD) method. The recovery rate of AFM1 with the ELISA method was 105% (73-124%), and the coefficient of variation of the analysis was 6.85%. The ELISA method showed a 0.20 pg/ml and 0.62 pg/ml limit of detection and limit of quantitation, respectively. In correlation analysis, the two methods showed a very strong and statistically significant correlation (R=0.96, p<0.01). However, in spite of the strong correlation, the ELISA method tended to overestimate the urinary AFM1 concentration compared to the HPLC-FLD method. These results suggest that the competitive ELISA method may be a useful technique for measuring the AFM1 level in high-throughput urine samples, but it needs to be corrected with a regression equation from regression analysis with the HPLC-FLD method.

Association between fatty liver disease and hearing impairment in Korean adults: a retrospective cross-sectional study

  • Da Jung Jung
    • Journal of Yeungnam Medical Science
    • /
    • v.40 no.4
    • /
    • pp.402-411
    • /
    • 2023
  • Background: We hypothesized that fatty liver disease (FLD) is associated with a high prevalence of hearing loss (HL) owing to metabolic disturbances. This study aimed to evaluate the association between FLD and HL in a large sample of the Korean population. Methods: We used a dataset of adults who underwent routine voluntary health checkups (n=21,316). Fatty liver index (FLI) was calculated using Bedogni's equation. The patients were divided into two groups: the non-FLD (NFLD) group (n=18,518, FLI <60) and the FLD group (n=2,798, FLI ≥60). Hearing thresholds were measured using an automatic audiometer. The average hearing threshold (AHT) was calculated as the pure-tone average at four frequencies (0.5, 1, 2, and 3 kHz). HL was defined as an AHT of >40 dB. Results: HL was observed in 1,370 (7.4%) and 238 patients (8.5%) in the NFLD and FLD groups, respectively (p=0.041). Compared with the NFLD group, the odds ratio for HL in the FLD group was 1.16 (p=0.040) and 1.46 (p<0.001) in univariate and multivariate logistic regression analyses, respectively. Linear regression analyses revealed that FLI was positively associated with AHT in both univariate and multivariate analyses. Analyses using a propensity score-matched cohort showed trends similar to those using the total cohort. Conclusion: FLD and FLI were associated with poor hearing thresholds and HL. Therefore, active monitoring of hearing impairment in patients with FLD may be helpful for early diagnosis and treatment of HL in the general population.

Association between Diabetes Mellitus and Fatty Liver Based on Ultrasonography Screening in the World's Highest Cholangiocarcinoma Incidence Region, Northeast Thailand

  • Thinkhamrop, Kavin;Khuntikeo, Narong;Phonjitt, Pichai;Chamadol, Nittaya;Thinkhamrop, Bandit;Moore, Malcolm Anthony;Promthet, Supannee
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.9
    • /
    • pp.3931-3936
    • /
    • 2015
  • Fatty liver disease (FLD) can be a precondition for other liver pathology including cholangiocarcinoma (CCA). Diabetes mellitus (DM) has been suggested in some studies to be a risk factor for FLD as well as cancers, including cholangiocellular carcinoma; however, there are currently very few studies on FLD in DM subjects, although the rate of FLD continues to increase annually. To determine the association between DM and FLD ultrasonographic data were analyzed from the Cholangiocarcinoma Screening and Care Program (CASCAP), in northeast Thailand. DM was reported by the subjects based on the CASCAP health questionnaire. Factors that were associated with FLD were determined by prevalence, odds ratio (ORs) and its 95% confidence intervals (CIs) using multiple logistic regression. There were 45,263 subjects with a mean age of 53.46 (${\pm}9.25$) years. FLD was found in 36.3% of DM subjects but only in 20.7% of non-DM subjects. The association between DM and FLD was adjusted for all other factors including gender, age, education level, relatives diagnosed with CCA, smoking, alcohol consumption, and hepatitis B and C. The risk of DM in subjects having FLD was highly significant compared with the non-DM subjects (OR 2.13; 95%CI: 1.92 to 2.35; p-value < 0.001). Thus DM is significantly associated with FLD which in turn may facilitate the development of several diseases including CCA. DM should be taken into consideration in future ultrasonic investigations of FLD and CCA.

A Method of Feature Extraction on Motor Imagery EEG Using FLD and PCA Based on Sub-Band CSP (서브 밴드 CSP기반 FLD 및 PCA를 이용한 동작 상상 EEG 특징 추출 방법 연구)

  • Park, Sang-Hoon;Lee, Sang-Goog
    • Journal of KIISE
    • /
    • v.42 no.12
    • /
    • pp.1535-1543
    • /
    • 2015
  • The brain-computer interface obtains a user's electroencephalogram as a replacement communication unit for the disabled such that the user is able to control machines by simply thinking instead of using hands or feet. In this paper, we propose a feature extraction method based on a non-selected filter by SBCSP to classify motor imagery EEG. First, we divide frequencies (4~40 Hz) into 4-Hz units and apply CSP to each Unit. Second, we obtain the FLD score vector by combining FLD results. Finally, the FLD score vector is projected onto the optimal plane for classification using PCA. We use BCI Competition III dataset IVa, and Extracted features are used as input for LS-SVM. The classification accuracy of the proposed method was evaluated using $10{\times}10$ fold cross-validation. For subjects 'aa', 'al', 'av', 'aw', and 'ay', results were $85.29{\pm}0.93%$, $95.43{\pm}0.57%$, $72.57{\pm}2.37%$, $91.82{\pm}1.38%$, and $93.50{\pm}0.69%$, respectively.

Formability Test of Boron Steel Sheet at Elevated Temperature for Hot Stamping (핫스탬핑용 보론강의 고온 성형한계선도 평가 연구)

  • Han, S.S.
    • Transactions of Materials Processing
    • /
    • v.26 no.2
    • /
    • pp.121-126
    • /
    • 2017
  • The hot stamping process is an innovative forming method that could prevent the cracking of high strength steel sheets. The formability test of boron steel sheet using forming limit diagrams at elevated temperature is very complicated and time consuming job. In this paper, an alternative test method to evaluate the formability of boron steel in hot stamping has proposed. It measured the FLD0 instead of whole strain combinations of FLD with the tensile test machine and specially designed test rig. Test results shows that the proposed test method can simulate the plain strain condition fracture and can make the FLD of boron steel sheet at elevated temperature with less effort.

Determination of Glutathione in Biological Samples by Ion-pairing HPLC/FLD (이온쌍 HPLC/FLD를 이용한 생체 시료중의 Glutathione 농도 분석)

  • Yoo, Jeong-Yeon;Lee, Kyoung-Ok;Shin, Ho-Sang
    • Analytical Science and Technology
    • /
    • v.12 no.1
    • /
    • pp.28-33
    • /
    • 1999
  • Glutathione(GSH) in biological samples was determined by high performance liquid chromatographic(HPLC) method with fluorescence detector(FLD) after monobromobimane(MBB) or 4-fluoro-7-sulfobenzofurazan(SBD-F) derivatization. The detection limit of $0.03{\mu}g/mL$ was obtained after MBB derivatization, derivative of MBB was about 200 times more sensitive than that of SBD-F. N-acetylcysteine was used as internal standard and tetrabutylammonium ion as counter ion for better separation. The determination by ion-pairing chromatography after MBB derivatization was characterized by linearity in the range between $0.08{\sim}8.33{\mu}g/mL$ with a good correlation coefficient of 0.998. By precision test appeared relative standard deviation at less than 5% at three different concentrations. This method can be used for the analysis of GSH in plasma and tissue.

  • PDF

Measurement of Total Plasma Homocysteine in Patients with Chronic Renal Failure Using HPLC/FLD (만성신부전증환자에서 HPLC/FLD를 이용한 혈장 Homocysteine의 측정)

  • Kyung-Ok Lee;Bo-Kyung Kang;Hyung-Jin Roh;Kwang-Suk Ryoo;Jeong-Yeon Yoo;Man-Jeong Paik;Kang-Hyeob Lee
    • Biomedical Science Letters
    • /
    • v.3 no.1
    • /
    • pp.29-35
    • /
    • 1997
  • Cardiovascular disease has been the leading cause of death among patients with chronic renal failure. Many reports have been described that homocysteine is one of the independent risk factor to the occulsive vascular disease. In this study, HPLC/FLD (high performance liquid chromatography-fluorescence detector) technique was used to measure homocysteine level in patients with chronic renal failure and normal control group. The detection limit and recovery of total plasma homocysteine using HPLC/FLD were 98.6$\pm$5.8% and 0.2 nmol/ml, respectively. The linearity of this method was established in concentration range of 2~50 nmol/ml (correlation coefficient=0.9997). The concentrations of total plasma homocysteine were 6.81$\pm$1.54 nmol/ml and 27.28$\pm$14.94 nmol/ml in normal control (n=20) and patient group (n=90), respectively (p<0.05). In this study, the HPLC/FLD method showed high sensitivity and reproducibility for a routine clinical laboratory testing. Moreover determination of homocysteine level in plasma might be useful for a biochemical marker for predicting the cardiovascular diseases and for monitoring of therapeutic effect of lowering homocysteine in patients with chronic renal failure.

  • PDF

Relationship of Colorectal Polyps and Fatty Liver Disease Diagnosed by Ultrasonography (초음파로 진단된 지방간 질환과 대장 용종과의 연관성)

  • Lee, Hye-Nam;Lim, Cheong-Hwan;Jung, Hong-Ryang
    • Journal of Digital Convergence
    • /
    • v.12 no.3
    • /
    • pp.345-352
    • /
    • 2014
  • This study proposes a more comprehensive approach for FLD by analyzing the relationship of colorectal polyps, which are precursors of colorectal cancer. In Chi-Square tests of FLD and colorectal polyps, the prevalence of colorectal polyps was significantly high in cases of FLD. The polyps and correlation of each factor showed a positive relationship with all factors, and the correlation coefficient with FLD was highest (r = 0.39, p <.001). In multiple regression analysis, FLD(OR 3.80 95% CI 1.93.-7.50), FBS (OR 2.51; 95% CI 1.12-5.62), and older age (OR 2.12; 95% CI 1.27-3.54) were independent risk factors for colorectal polyps. FLD was associated with the prevalence of colorectal polyps. These results show a meaningful influenceof FLD by ultrasonography in the occurrence of colorectal polyps, and that positive consideration of colonoscopy is needed for diagnosed FLD.

Development of Analytical Methods for Micro Levels of Naphthalene and TNT in Groundwater by HPLC-FLD and MSD (HPLC-FLD와 MSD를 이용한 지하수 중 나프탈렌 및 TNT의 미량 분석법 개발)

  • Park, Jong-Sung;Oh, Je-Ill;Jeong, Sang-Jo;Choi, Yoon-Dae;Her, Nam-Guk
    • Journal of Soil and Groundwater Environment
    • /
    • v.14 no.6
    • /
    • pp.35-44
    • /
    • 2009
  • Naphthalene and TNT (2,4,6-trinitrotoluene) are defined by U.S. EPA as possible carcinogenic compounds known to have detrimental effects on the aquatic ecosystem and human body. There are, however, few researches on methods of analyzing micro-levels of naphthalene and TNT dissolved in groundwater. This study introduces and evaluates the newly developed analytical methods of measuring naphthalene and TNT in groundwater by using HPLC-FLD (Fluorescence detector) and MSD (Mass detector). The MDL, LOQ and salt effect of these methods, respectively, are compared with those of conventional methods which use HPLC-UV. For the analysis of naphthalene, HPLC-FLD was set in the maxima wavelength (Ex: 270 nM, Em: 330 nM) obtained from 3D-Fluorescence to be compared with HPLC-UV in 266 nM wavelength. The MDL ($0.3\;{\mu}g/L$) and LOQ ($2.0\;{\mu}g/L$) of naphthalene by using HPLC-FLD were approximately 80 times lower than those analyzed by HPLC-UV (MDL: $23.3\;{\mu}g/L$, LOQ: $163.1\;{\mu}g/L$). HPLC-MSD were used in comparison with HPLC-UV in 230 and 254 nM wavelength for the analysis of TNT. The MDL ($0.13\;{\mu}g/L$) and LOQ ($0.88\;{\mu}g/L$) of TNT analyzed by using HPLC-MSD were approximately 130 times lower than those obtained by using HPLC-UV in 230 nM (MDL: $16.8\;{\mu}g/L$, LOQ: $117.5\;{\mu}g/L$). The chromatogram of TNT analyzed by using HPLC-UV in 230 nM displayed elevated baseline as the concentration of ${NO_3}^-$ increases beyond 21 mg/L, while the analysis using HPLC-MSD did not demonstrate any change in baseline in presence of ${NO_3}^-$ of 63.7 mg/L which is 3.5 times higher than average concentration in groundwater. In conclusion, HPLC-FLD and HPLC-MSD may be used as suitable methods for the analysis of naphthalene and TNT in groundwater and drinking water. These methods can be applied to the monitoring of naphthalene and TNT concentration in groundwater or drinking water.