• Title/Summary/Keyword: FLAIR

Search Result 81, Processing Time 0.027 seconds

Imaging Studies in Mouse Brain Using Clinical 3T MRI Scanner (임상용 3T MRI를 이용한 마우스 뇌의 영상)

  • Lim, Soo-Mee;Park, Eun-Mi
    • Progress in Medical Physics
    • /
    • v.21 no.4
    • /
    • pp.348-353
    • /
    • 2010
  • The purpose of this study was to explore the potentials of a clinical 3T MRI in mouse brains and technical adaptation and optimization. T1-weighted images (T1WI), T2-weighted images (T2WI), FLAIR (Fluid Attenuated Inversion Recovery) images, Gadolinium enhanced T1-weighted images (Gd-T1WI), Diffusion weighted images (DWI) were acquired in brain of 2 mice (weight 20~25 g) with cerebral infarction by occlusion of right middle cerebral artery, 1 hour, 24 hours, 72 hours after infarction and 1 normal mouse brain using clinical 3T MRI scanner. We analyzed differentiation of striatum, ventricle, cerebral cortex, and possibility of detection of acute cerebral infarction. We could differentiate the striatum, ventricle, cerebral cortex on T2WI and on DWI, FLAIR, T1WI, the differentiation of each anatomy of brain was not definite, but acute cerebral infarction was detected on DWI of 1 hour, 24 hours, 72 hours after infarction and on T2WI, FLAIR of 24 hours, 72 hours after infarction. Clinical 3T MRI can be used in differentiation of anatomy of mouse brains and DWI can be helpul in detection of acute cerebral infarction in acute phase. With technical adaptation and optimization clinical 3T MRI can be useful tool for provide preclinical and clinical small animal studies.

The Relationship between Image Parameters and SAR for Each Sequence of MRI (MRI 검사의 시퀀스 별 영상 변수와 SAR의 관계)

  • Seong-Ho Kim;Se-Jong Yoo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.7
    • /
    • pp.1133-1138
    • /
    • 2023
  • This study analyzed the relationship between image parameters and specific absorption rate (SAR) in various sequence environments to optimize SAR. For this purpose, image parameters were adjusted for T2, T1, STIR, T1 FLAIR, and T2 FLAIR sequences in a 3.0T MRI, and the whole body (WB) SAR and head SAR calculated by the device were measured. Then, the SAR was evaluated by adjusting the number of images and the flip angle (FA) of the refocusing RF. As a result, SAR increased as the number of image increased in all sequences. T1 and T1 FLAIR had correlation coefficients (r) of 0.876, 0.876 (WB SAR, head SAR), 0.867, 0.867 (WB SAR, head SAR), respectively, and STIR had the highest correlation with 0.898 and 0.899 (WB SAR, head SAR). showed (p<0.05). When applied by increasing the refocusing FA, WB SAR and head SAR increased overall in all sequences. The T1 and T2 sequences showed high correlation with correlation coefficients (r) of 0.897, 0.898 (WB SAR, head SAR) and 0.914, 0.915 (WB SAR, head SAR), respectively, while the sequences to which the inversion recovery technique was applied had relatively low FA, showed less sensitivity to increase. Therefore, in a sequence with a relatively low TR, minimizing the number of image and applying the fast spin echo to reduce the refocusing FA in a sequence with a high duty cycle are effective in reducing SAR.

Quantitative Analysis of MR Image in Cerebral Infarction Period (뇌경색 시기별 MR영상의 정량적 분석)

  • Park, Byeong-Rae;Ha, Kwang;Kim, Hak-Jin;Lee, Seok-Hong;Jeon, Gye-Rok
    • Journal of radiological science and technology
    • /
    • v.23 no.1
    • /
    • pp.39-47
    • /
    • 2000
  • In this study, we showed a comparison and analysis making use of DWI(diffusion weighted image) using early diagnosis of cerebral Infarction and with the classified T2 weighted image, FLAIR images signal intensity for brain infarction period. period of cerebral infarction after the condition of a disease by ischemic stroke. To compare 3 types of image, we performed polynomial warping and affined transform for image matching. Using proposed algorithm, calculated signal intensity difference between T2WI, DWI, FLAIR and DWI. The quantification values between hand made and calculated data are almost the same. We quantified the each period and performed pseudo color mapping by comparing signal intensity each other according to previously obtained hand made data, and compared the result of this paper according to obtained quantified data to that of doctors decision. The examined mean and standard deviation for each brain infarction stage are as follows ; the means and standard deviations of signal intensity difference between DWI and T2WI for each period are $197.7{\pm}6.9$ in hyperacute, $110.2{\pm}5.4$ in acute, and $67.8{\pm}7.2$ in subacute. And the means and standard deviations of signal intensity difference between DWI and FLAIR for each period are $199.8{\pm}7.5$ in hyperacute, $115.3{\pm}8.0$ in acute, and $70.9{\pm}5.8$ in subacute. We can quantificate and decide cerebral infarction period objectively. According to this study, DWI is very exact for early diagnosis. We classified the period of infarction occurrence to analyze the region of disease and normal region in DW, T2WI, FLAIR images.

  • PDF

Quantitative Analysis of GBCA Reaction by Mol Concentration Change on MRI Sequence (MRI sequence에 따른 GBCA 몰농도별 반응에 대한 정량적 분석)

  • Jeong, Hyun Keun;Jeong, Hyun Do;Kim, Ho Chul
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.2
    • /
    • pp.182-192
    • /
    • 2015
  • In this paper, we introduce how to change the reaction rate as mol concentration when we scan enhanced MRI with GBCA(Gadolinium Based Contrast Agent), Also show the changing patterns depending on diverse MRI sequences which are made by different physical principle. For this study, we made MRI phantom ourselves. We mixed 500 mmol Gadoteridol with Saline in each 28 different containers from 500 to 0 mmol. After that, MR phantom was scanned by physically different MRI sequences which are T1 SE, T2 FLAIR, T1 FLAIR, 3D FLASH, T1 3D SPACE and 3D SPCIR in 1.5T bore. The results were as follows : *T1 Spin echo's Total SI(Signal Intensity) was 15608.7, Max peak was 1352.6 in 1 mmol. *T2 FLAIR's Total SI was 9106.4, Max peak was 0.4 1721.6 in 1 mmol. *T1 FLAIR's Total SI was 20972.5, Max peak was 1604.9 in 1 mmol. *3D FLASH's Total SI was 20924.0, Max peak was 1425.7 in 40 mmol. *3D SPACE 1mm's Total SI was 6399.0, Max peak was 528.3 in 3 mmol. *3D SPACE 5mm's Total SI was 6276.5, Max peak was 514.6 in 2 mmol. *3D SPCIR's Total SI was 1778.8, Max peak was 383.8 in 0.4 mmol. In most sequences, High signal intensity was shown in diluted lower concentration rather than high concentration, And also graph's max peak and pattern had difference value according to the each different sequence. Through this paper which have quantitative result of GBCA's reaction rate depending on sequence, We expect that practical enhanced MR protocol can be performed in clinical field.

Susceptibility-Weighted MR Imaging for the Detection of Developmental Venous Anomaly: Comparison with T2 and FLAIR Imaging (자화율강조 MR영상을 이용한 뇌정맥 기형의 진단: T2강조영상과 FLAIR영상과의 비교)

  • Cho, Soo Bueum;Choi, Dae Seob;Ryu, Hyeon Gyu;Shin, Hwa Seon;Kim, Ji-Eun;Choi, Hye Young;Park, Mi Jung;Choi, Ho Cheol;Son, Seungnam
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.3
    • /
    • pp.200-207
    • /
    • 2014
  • Purpose : We evaluated the diagnostic value of susceptibility-weighted imaging (SWI) for the detection of developmental venous anomaly (DVA). Materials and Methods: Retrospective review of 1068 brain MR examinations found 28 DVAs in 28 patients (2.6%) on contrast-enhanced T1-weighted images. SWI, T2, and FLAIR images of 28 patients with DVA and 28 sex- and age-matched control patients without DVA were analyzed by blinded readers on each type of sequences. All images were independently reviewed by two radiologists who were blinded to other MR imaging finding. In cases of discrepancy, two reviewers reached a consensus later. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of each MR sequence for the detection of DVA were determined. Statistical analysis was performed by using the Mcnemar test. The significance level was p < 0.05. Results: The sensitivity, specificity, PPV, and NPV of SWI for the detection of DVA were 85.7%, 92.9%, 92.3%, and 86.7%, respectively. T2 and FLAIR images showed sensitivity of 35.7% and 35.7%, specificity of 92.9% and 96.4%, PPV of 83.3% and 90.9%, and NPV of 59.1% and 60.0%, respectively. On SWI, the sensitivity and NPV for the detection of DVAs were significantly higher than those of T2 and FLAIR images (p < 0.05). Conclusion: SWI was sensitive and specific for the detection of DVA.

A Comparative Study of SNR and Image According to the Aplication Coil in MRI Inspection (자기공명영상검사에서 Coil적용에 따른 SNR과 영상의 비교연구)

  • Park, Ye-won;Lim, Cheong-hwan
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2015.05a
    • /
    • pp.147-148
    • /
    • 2015
  • MRI검사 시 다양한 환자를 고려한 변화에 적절한 coil의 선택과 조건에 따른 SNR의 차이를 조사하여 우수한 SNR의 영상을 획득하고자 한다. MR영상 획득실험은 Bottle Phantom를 이용하여 Philips achieva 1.5T와 SIMENS 1.0T을 이용하여 sequence별, surface coil별로 MR영상을 획득하여 SNR를 구하였다. 주자장이 1.0T에서 가장 높은 SNR은 TSE와 FLAIR에서 knee coil, GE에서 head coil로 측정되었고, 주자장이 1.5에서 가장 높은 SNR은 TSE에서 head coil, FLAIR와 GE에서 knee coil로 측정되었다. 본 연구에서 획득한 결과를 중심으로 다양한 환자를 고려한 변화에 따른 적절한 coil의 선택과 조건에 따라 SNR의 차이를 조사하여 우수한 SNR의 영상을 제시하여야 한다.

  • PDF

The Learning of Mathematical Algorithms and Formulas without Understanding or Flair

  • Suffolk, John
    • Research in Mathematical Education
    • /
    • v.13 no.1
    • /
    • pp.13-22
    • /
    • 2009
  • School children in Brunei Darussalam, as elsewhere, learn how to apply a lot of algorithms and formulas in mathematics. These include methods of finding the lowest common multiple and highest common multiple of numbers and methods of factorizing quadratics. Investigations and experience have shown that both able and less able students learn to do these mechanically and unimaginatively and in a way that is reliable when answering examination questions. Most of them do not, however, learn these algorithms and methods so as to develop a deeper insight of what they learn and thereby perform even more effectively in examinations. Yet it is possible to teach these and other methods for understanding in ways that are enjoyable and enable students to use them effectively and with flair.

  • PDF

An Inference Onset of the Cerebral Infarction Diseases using MR Image (MR 영상을 이용한 뇌경색 질환의 발현시기 추정)

  • Park, B.R.;Kim, H.J.;Jun, K.R.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.305-306
    • /
    • 1998
  • In this paper, we infer the onset of the brain infarction from the MR image using evaluate signal intensities on diffusion weighted and turbo spin echo T2-weighted and FLAIR images. Infarcts were divided into four stages (hyperacute, acute, subacute, chronic) depending on period of onset. DWI is useful for the detection of early ischemic infarct, and stages of ischemic infarctions can be estimated by evaluating CR(conspicuity ratio) and CNR(contrast to noise ratio) on DW, T2, FLAIR images Hyperacute infarcts were visualized DWI. Acute infarcts were visualialized both DWI and T2 Weighted image.

  • PDF

Optimizations of 3D MRI Techniques in Brain by Evaluating SENSE Factors (삼차원 자기공명영상법의 뇌 구조 영상을 위한 최적화 연구: 센스인자 변화에 따른 신호변화 평가)

  • Park, Myung-Hwan;Lee, Jin-Wan;Lee, Kang-Won;Ryu, Chang-Woo;Jahng, Geon-Ho
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.2
    • /
    • pp.161-170
    • /
    • 2009
  • Purpose : A parallel imaging method provides us to improve temporal resolution to obtain three-dimensional (3D) MR images. The objective of this study was to optimize three 3D MRI techniques by adjusting 2D SESNE factors of the parallel imaging method in phantom and human brain. Materials and Methods : With a 3 Tesla MRI system and an 8-channel phase-array sensitivity-encoding (SENSE) coil, three 3D MRI techniques of 3D T1-weighted imaging (3D T1WI), 3D T2-weighted imaging (3D T2WI) and 3D fluid attenuated inversion recovery (3D FLAIR) imaging were optimized with adjusting SESNE factors in a water phantom and three human brains. The 2D SENSE factor was applied on the phase-encoding and the slice-encoding directions. Signal-to-noise ratio(SNR), percent signal reduction rate(%R), and contrast-to-noise ratio(CNR) were calculated by using signal intensities obtained in specific regions-of-interest (ROI). Results : In the phantom study, SENSE factor = 3 was provided in 0.2% reduction of signals against without using SENSE with imaging within 5 minutes for 3D T1WI. SENSE factor = 2 was provided in 0.98% signal reduction against without using SENSE with imaging within 5 minutes for 3D T2WI. SENSE factor = 4 was provided in 0.2% signal reduction against without using SENSE with imaging around 6 minutes for 3D FLAIR. In the human brain study, SNR and CNR were higher with SENSE factors = 3 than 4 for all three imaging techniques. Conclusion : This study was performed to optimize 2D SENSE factors in the three 3D MRI techniques that can be scanned in clinical time limitations with minimizing SNR reductions. Without compromising SNR and CNR, the optimum 2D SENSE factors were 3 and 4, yielding the scan time of about 5 to 6 minutes. Further studies are necessary to optimize 3D MRI techniques in other areas in human body.

  • PDF