• 제목/요약/키워드: FLAIR

검색결과 81건 처리시간 0.022초

Assessment of Diffusion-Weighted Imaging-FLAIR Mismatch: Comparison between Conventional FLAIR versus Shorter-Repetition-Time FLAIR at 3T

  • Goh, Byeong Ho;Kim, Eung Yeop
    • Investigative Magnetic Resonance Imaging
    • /
    • 제20권2호
    • /
    • pp.88-94
    • /
    • 2016
  • Purpose: Fluid-attenuated inversion recovery (FLAIR) imaging can be obtained faster with shorter repletion time (TR), but it gets noisier. We hypothesized that shorter-TR FLAIR obtained at 3 tesla (3T) with a 32-channel coil may be comparable to conventional FLAIR. The aim of this study was to compare the diagnostic value between conventional FLAIR (TR = 9000 ms, FLAIR9000) and shorter-TR FLAIR (TR = 6000 ms, FLAIR6000) at 3T in terms of diffusion-weighted imaging-FLAIR mismatch. Materials and Methods: We recruited 184 patients with acute ischemic stroke (28 patients < 4.5 hours) who had undergone 5-mm diffusion-weighted imaging (DWI) and two successive 5-mm FLAIR images (no gap; in-plane resolution, $0.9{\times}0.9mm$) at 3T with a 32-channel coil. The acquisition times for FLAIR9000 and FLAIR6000 were 108 seconds (generalized autocalibrating partially parallel acquisitions [GRAPPA] = 2) and 60 seconds (GRAPPA = 3), respectively. Two radiologists independently assessed the paired imaging sets (DWI-FLAIR9000 and DWI-FLAIR6000) for the presence of matched hyperintense lesions on each FLAIR imaging. The signal intensity ratios (area of DWI lesion to contralateral normal-appearing region) on both FLAIR imaging sets were compared. Results: DWI-FLAIR9000 mismatch was present in 39 of 184 (21.2%) patients, which was perfectly the same on FLAIR6000. Three of 145 patients (2%) with DWI-matched lesions on FLAIR9000 had discrepancy on FLAIR6000, showing no significant difference (P > 0.05). Interobserver agreement was excellent for both DWI-FLAIR9000 and DWI-FLAIR6000 (k = 0.904 and 0.883, respectively). Between the two FLAIR imaging sets, there was no significant difference of signal intensity ratio (mean, standard deviation; $1.25{\pm}0.20$; $1.24{\pm}0.20$, respectively) (P > 0.05). Conclusion: For the determination of mismatch or match between DWI and FLAIR imaging, there is no significant difference between FLAIR9000 and FLAIR6000 at 3T with a 32-channel coil.

급성 허혈성 뇌경색 환자의 자기공명영상 검사 시 Echo Planar Image T2 FLAIR 기법의 유용성에 관한 연구 (A Study on the Usability of Echo Planar Image T2 FLAIR Sequence in the MRI of Acute Ischemic Cerebral Infarction)

  • 노태관;조용근
    • 한국방사선학회논문지
    • /
    • 제14권7호
    • /
    • pp.957-964
    • /
    • 2020
  • 본 연구는 현재 사용되고 있는 가장 빠른 Pulse Sequence 중 하나인 EPI기법과 T2 FLAIR 기법 두 가지를 함께 적용하여 사용하는 EPI-FLAIR기법을 급성 허혈성 뇌경색 환자에게 적용하여, EPI-FLAIR 기법의 진단적 유용성에 대하여 평가하였다. 연구 결과 정성적, 정량적 분석 결과 EPI-FLAIR 기법이 T2 FLAIR 기법과 비교 시 통계적으로 유의한 차이가 있음을 알 수 있었으며, 결론적으로 EPI-FLAIR 기법은 화질의 저하 없이 영상획득시간을 줄일 수 있어 허혈성 급성 뇌경색 및 뇌출혈, 신경학적 결핍, 경색 시기 진단이 필요한 환자의 여러 가지 뇌 병변 평가와 함께 비협조적인 환자들에게 발생하는 Motion Artifact를 줄일 수 있는 장점 있어 T2 FLAIR와 비교하여 충분한 진단적 가치가 있다고 사료된다.

뇌전이 환자의 조영 증강 후 지연 FLAIR 영상의 유용성 (Patients with brain metastases the usefulness of contrast-enhanced FLAIR images after delay)

  • 변재후;박명환;이진완
    • 대한디지털의료영상학회논문지
    • /
    • 제16권1호
    • /
    • pp.13-19
    • /
    • 2014
  • Purpose: FLAIR image is beneficial for the diagnosis of various bran diseases including ischemic CVS, brain tumors and infections. However the border between the legion of brain metastasis and surrounding edema may not be clear. Therefore, this study aims to investigate the practical benefits of delayed imaging by comparing the image from a patient with brain metastasis before a contrast enhancement and the image 10 minutes after a contrast enhancement. Materials and methods: Of the 92 people who underwent MRI brain metastases in suspected patients 13 people in three patients there is no video to target the 37 people confirmed cases, and motion artifacts brain metastases in our hospital June-December 2013, 18 people measurement position except for the three incorrect patient (male: 11 people, female: 7 people, average age: 60 years) in the target, test equipment, 3.0T MR System (ACHIEVA Release, Philips, I was 8ChannelSENSE Head Coil use Best, and the Netherlands). TR 11000 ms, TE 125 ms, TI2800 ms, Slice Thickness 5 mm, gap 5 mm, is a Slice number 21, the parameters of the 3D FFE, T2 FLAIR variable that was used to test, TR 8.1 ms, TE 3.7 ms, Slice number 240 I set to. The experiment was conducted by acquiring the FLAIR prior to contrast enhancement (heretofore referred to as Pre FLAIR), and acquiring the 3D FFE CE five minutes after the contrast enhancement, and recomposing the images in an axial plane of S/T 3mm, G 0mm (heretofore referred to as MPR TRA CE). Using the FLAIR 10 minutes after the contrast enhancement (heretofore referred to as Post FLAIR) and Pi-View, a retrospective study was conducted. Using MRIcro on the image of a patient confirmed for his diagnosis, the images before and after the contrast media, as well as the CNR and SNR of the MPR TRA CE images of the lesion and the site absent of lesion were compared and analyzed using a one-way analysis of variance. Results: CNR for Pre FLAIR and Post FLAIR were 34.35 and 60.13, respectively, with MPR TRA CE at 23.77 showing no significant difference (p<0.050). Post-experiment analysis shows a difference between Pre FLAIR and Post FLAIR in terms of CNR (p<0.050), but no difference in CNR between Post FLAIR and MPR TRA CE (p>0.050), indicating that the contrast media had an effect only on Pre FLAIR and Post FLAIR. The SNR for the normal site Pre FLAIR was 106.43, and for the lesion site 140.79. Post FLAIR for the normal site was 107.79, and for the lesion site 167.91. MPR TRA CE for the normal site was 140.23 and for the lesion site 183.19, showing significant difference (p<0.050), and post-experiment analysis shows that there was a difference in SNR only on the lesion sites for Pre FLAIR and Post FLAIR (p<0.050). There was no difference in SNR between the normal site and lesion site for Post FLAIR and MPR TRA CE, indicating no effect from the contrast media (p>0.050). Conclusions: This experiment shows that Post FLAIR has a higher contrast than Pre FLAIR, and a higher SNR for lesions, It was not not statistically significant and MPR TRA CE but CNR came out high. Inspection of post-contrast which is used in a high magnetic field is frequently used images of 3D T1 but, since the signal of the contrast medium and the blood flow is included, this method can be diagnostic accuracy is reduced, it is believed that when used in combination with Post FLAIR, and that can provide video information added to the diagnosis of brain metastases.

  • PDF

Comparison of Contrast-Enhanced T2 FLAIR and 3D T1 Black-Blood Fast Spin-Echo for Detection of Leptomeningeal Metastases

  • Park, Yae Won;Ahn, Sung Jun
    • Investigative Magnetic Resonance Imaging
    • /
    • 제22권2호
    • /
    • pp.86-93
    • /
    • 2018
  • Purpose: Imaging plays a significant role in diagnosing leptomeningeal metastases. However, the most appropriate sequence for the detection of leptomeningeal metastases has yet to be determined. This study compares the efficacies of contrast-enhanced T2 fluid attenuated inversion recovery (FLAIR) and contrast-enhanced 3D T1 black-blood fast spin echo (FSE) imaging for the detection of leptomeningeal metastases. Materials and Methods: Tube phantoms containing varying concentrations of gadobutrol solution were scanned using T2 FLAIR and 3D T1 black-blood FSE. Additionally, 30 patients with leptomeningeal metastases were retrospectively evaluated to compare conspicuous lesions and the extent of leptomeningeal metastases detected by T2 FLAIR and 3D T1 black-blood FSE. Results: The signal intensities of low-concentration gadobutrol solutions (< 0.5 mmol/L) on T2 FLAIR images were higher than in 3D T1 black-blood FSE. The T2 FLAIR sequences exhibited significantly greater visual conspicuity scores than the 3D T1 black-blood sequence in leptomeningeal metastases of the pial membrane of cistern (P = 0.014). T2 FLAIR images exhibited a greater or equal extent (96.7%) of leptomeningeal metastases than 3D T1 black-blood FSE images. Conclusion: Because of its high sensitivity even at low gadolinium concentrations, contrast-enhanced T2 FLAIR images delineated leptomeningeal metastases in a wider territory than 3D T1 black-blood FSE.

급성 거미막하 출혈의 진단: FLAIR MR영상과 조영전 CT와의 비교 (Detection of Acute Subarachnoid Hemorrhage: Comparison of FLAIR MR Imaging with Unenhanced CT)

  • 최원진;최대섭;김정혜;김순;이현경;오연희;김승현;이성우;김욱년;이규춘
    • Investigative Magnetic Resonance Imaging
    • /
    • 제5권2호
    • /
    • pp.149-154
    • /
    • 2001
  • 목적 : 급성 거미막하 출혈의 진단에 있어 CT와 비교하여 fluid-attenuated inversion-recovery (FLAIR) MR영상의 유용성을 평가하고자 하였다. 대상 및 방법 : 증상 발생 3일 이내에 비조영 CT와 FLAIR MR영상을 모두 얻었던 28명의 급성 지주막하 출혈 환자를 대상으로 하였다. 거미막하 공간을 피질구, 실비우스열구, 기저조, 후두와의 4부위로 나누어 각 부위 별로 CT와 FLAIR영상에서 출혈이 보이는 정도를 0(출혈 없음), 1(출혈 의심), 2(뚜렷한 출혈)의 점수로 구분하여 평가하였다. 또한 이들 28명 환자와 대조군 35명의 FLAIR영상을 비교하여 거미막하 공간의 고신호 강도를 기준으로 출혈의 유무를 판정할 경우, FLAIR영상의 민감도, 특이도 및 진단적 정확도를 평가하였다. 결과 : FLAIR영상에서 급성 거미막하 출혈은 모든 환자에서 뇌척수액이나 뇌 실질보다 고신호 강도를 보여 100%의 발견율을 보였다. CT와 비교하여 피질구($1.11{\pm}0.80$ vs $0.70{\pm}0.83$: p(0.05)와 후두와($1.41{\pm}0.74$ vs $0.78{\pm}0.80$: p(0.05)에서 FLAIR영상이 CT보다 통계적으로 유의하게 우수하였다 FLAIR영상에서 거미막하 공간의 고신호 강도를 기준으로 거미막하 출혈 유무를 평가한 결과에서 100%의 민감도, 특이도 및 진단적 정확도를 보였다. 결론 급성 거미막하 출혈의 진단에 FLAIR MR영상은 매우 유용하며, 특히 출혈의 양이 소량인 경우와 후두와의 출혈을 진단하는데 CT보다 우수하다.

  • PDF

경증 두부외상 환자에서 MR FLAIR 영상의 임상적 유용성 (Clinical Usefulness of MR FLAIR Image in Mild Head Injuries)

  • 김세윤;황금;김헌주;이명섭
    • Journal of Korean Neurosurgical Society
    • /
    • 제30권10호
    • /
    • pp.1182-1186
    • /
    • 2001
  • Objectives : MR fluid-attenuated inversion recovery(FLAIR) image uses paired long inversion time and relaxation time that nulls the signal from CSF. With nulling of the CSF long echo time readout could be used to increase T2-weighting, hence improving the conspicuousness of most tissue lesions without the deleterious effects of CSF artifact seen on T2 weighted sequence. We examed the usefulness of FALIR image in the diagnosis of mild head injury. Methods : A total of 38 patients with mild head injury were examined by FLAIR image. We compared those images with CT scan and T1, T2-weighted images. Careful observation of MR images were done by two well-trained neuroradiologists. Each image was compared for conspicuousness and detectability of traumatic lesions might have shown abnormal signal intensities. The Wilcoxon signed ranks test was used for statistical evaluation. Results : The FLAIR image was significantly more sensitive than those of other images(p<0.001). T2 FFE(Fast Field Echo) image was more useful for detection of small petechial hemorrhages. Conclusion : FLAIR image is considered to be more sensitive than those of conventional MR images in the evaluation of mild head injuries.

  • PDF

T1, T2강조영상, FLAIR영상의 임상 적용 (T1-, T2-weighted, and FLAIR Imaging: Clinical Application)

  • 김재형
    • Investigative Magnetic Resonance Imaging
    • /
    • 제13권1호
    • /
    • pp.9-14
    • /
    • 2009
  • T1, T2강조영상, FLAIR (fluid attenuated inversion recovery) 영상기법은 뇌 MRI의 가장 기본적인 영상기법들이다. T1강조영상은 짧은 TR과 짧은 TE를 이용한 스핀에코 기법으로서 조직의 T1이완시간의 차이를 신호 차이로 반영하는 기법이다. 짧은 TR을 사용하면 조직 간에 종축 자기화의 회복 정도가 크게 차이나게 되며 이를 신호에 반영하는 것이다. T2강조영상은 긴 TR과 긴 TE를 이용한 스핀에코 기법으로서 조직의 T2이완시간의 차이를 신호 차이로 반영하는 기법이다. 긴 TE을 사용하면 조직 간에 횡축 자기화의 붕괴가 크게 차이나게 되며 이를 신호에 반영하는 것이다. FLAIR는 180도 반전펄스를 먼저 가하는 반전회복 (inversion recovery) 기법의 일종으로서 뇌척수액의 신호를 억제하기 위하여 2500 msec 정도의 반전시간을 적용한다.

  • PDF

조영증강을 보이는 뇌종양의 평가에 있어 T1강조 FLAIR 영상과 스핀에코 MR 영상의 비교 (T1-weighted FLAIR MR Imaging for the Evaluation of Enhancing Brain Tumors: Comparison with Spin Echo Imaging)

  • 정보슬;최대섭;신화선;최혜영;박미정;전경녀;나재범;정성훈
    • Investigative Magnetic Resonance Imaging
    • /
    • 제18권2호
    • /
    • pp.151-156
    • /
    • 2014
  • 목적: T1강조 MR영상은 뇌의 해부학적 구조와 병리학적 이상을 보여 주는 기본적인 영상기법의 하나로, 전통적으로 스핀에코(SE) 기법을 이용하여 획득하고 있다. 최근 FLAIR 기법을 이용하여 T1강조영상을 얻을 수 있게 되었으며, SE보다 높은 대조도의 영상을 제공한다고 알려져 있다. 그러나 조영증강을 보이는 뇌종양의 평가에 있어 T1 FLAIR 영상의 유용성에 대해서는 논란이 있다. 본 연구의 목적은 조영증강을 보이는 두개 내 종양의 평가에 있어 SE T1강조영상과 비교하여 T1 FLAIR영상의 유용성을 평가하고자 하였다. 대상과 방법: 총 52명 환자의 79개 병변을 대상으로 하였다. 각 환자에서 조영증강 후 SE T1강조영상과 T1 FLAIR 영상을 획득하였다. 정량적 분석으로 각각의 영상에서 병변, 뇌회색질(GM), 뇌백질(WM), 뇌척수액(CSF), 배경(background)의 신호강도를 측정하였고, 이를 바탕으로 병변과 WM, 병변과 GM, 병변과 CSF, WM와 GM의 contrast ratio(CR), contrast-to-noise(CNR)를 계산하였다. 정성적 분석으로 두 명의 영상의학과 의사가 각 영상에서 병변의 명확도(lesion conspicuity)를 비교 하였다. 결과: 정량적 분석 결과에서 T1 FLAIR영상의 병변과 GM, 병변과 CSF, WM와 GM의 CR, CNR 모두 SE T1강조영상보다 우월하였으며 이는 통계적으로 유의하였다. 그러나 병변과 WM의 CR, CNR은 비슷하였으며 통계적으로 유의한 차이를 보이지 않았다. 정성적 분석에서 두 영상의학과 의사 모두 병변의 명확도에 있어 T1 FLAIR영상이 SE영상보다 우월하다고 평가하였다. 결론: 조영증강을 보이는 뇌종양의 평가에 있어 T1 FLAIR영상은 SE T1강조영상보다 우수하거나 필적한 결과를 보였다.

산소주입에 의한 FLAIR 영상에서 생리식염수의 신호 변화 (Signal Change of Normal Saline by Oxygen Injection in FLAIR Image)

  • 신운재
    • 한국방사선학회논문지
    • /
    • 제13권1호
    • /
    • pp.55-63
    • /
    • 2019
  • 고농도의 산소를 흡입하는 경우에 자기공명영상의 FLAIR(fluid attenuated inversion-recovery, FLAIR) 영상에서 뇌척수액에서 신호가 억제되지 않고 고신호로 나타나는 경우가 있다는 보고가 있었다. 본 연구는 아가 젤로 고정한 팬텀을 제작하여 산소를 주입한 생리식염수와 조영제를 희석한 생리식염수의 신호를 FLAIR 기법의 반전시간(TI : inversion time)을 변화하여 영상을 획득하고, 분석하여 기초자료를 마련 하고자 하였다. 부산 P병원의 Philips Achieva MR 3.0T를 이용한 결과에서 자기공명영상의 FLAIR 기법에서 산소가 주입된 생리식염수의 신호 대 잡음비(signal to noise ratio)는 산소가 주입되지 않은 생리식염수 보다 증가되었다. 하지만 희석된 조영제보다는 높지 않았다. 반전시간 1,800ms에서는 산소에 의한 신호 증강이 없는 영상을 획득할 수 있었다. 산소가 주입된 생리식염수와 조영제의 대조도 대 잡음비(contrast to noise ratio)에서도 임상에서 주로 사용하는 반전시간 2,800ms보다 1,800ms에서 높게 증가되었다. 본 실험의 결과가 자기공명영상의 FLAIR 기법에서 산소 주입에 따른 뇌척수액의 신호 변화 연구에 기초자료가 될 수 있을 것으로 사료된다.

저산소성-허혈성 뇌증의 확산강조영상 소견 (Diffusion-weighted MR Imaging of Hypoxic-Ischemic Encephalopathy)

  • 최혜영;최대섭;유재욱;조재민;고은숙;신태범;나재범;최낙천
    • Investigative Magnetic Resonance Imaging
    • /
    • 제12권1호
    • /
    • pp.49-54
    • /
    • 2008
  • 목적 : 저산소성-허혈성 뇌증(HIE)의 확산강조영상(DWI) 소견을 알아보고자 하였다. 대상 및 방법 : 심폐기능 정지에 의한 뇌손상으로 심폐소생술을 통하여 소생된 6명의 환자를 대상으로 하였으며 뇌손상 후 MR검사까지의 시간 간격은 4일에서부터 32일까지 평균 11.8일 이었다. 전 예에서 T1 및 T2강조영상, FLAIR, DWI 및 현성확산계수영상을 얻었다. 병변의 분포, 각 영상에서의 신호 강도를 분석하였으며, T2 및 FLAIR영상과 비교한 DWI에서의 병변의 명확도를 분석하였다. 결과 : 전 예에서 T2, FLAIR 및 DWI에서 기저핵에 양측으로 대칭적인 고신호 강도의 병변을 볼 수 있었다. 현성확산계수영상에서는 이중 4예가 저신호 강도를, 2예는 동등신호 강도를 보였다. 병변의 명확도는 6예 중 4예에서 T2 및 FLAIR영상과 비교하여 DWI에서 뚜렷한 고신호 강도를 보였고, 2예에서는 비슷하였다. 대뇌 피질과 피질하 백질의 경우 6예 중 5예에서 T2, FLAIR 및 DWI에서 양측으로 대칭적인 고신호 강도를 보였고, 그 중 3예에서는 T2 및 FLAIR 영상과 비교하여 DWI에서 명확하게 보였다. 현성확산계수영상에서는 3예가 저신호 강도를, 나머지는 동등신호 강도를 보였다. 대뇌 심부백질의 경우 6예 중 4예에서 T2, FLAIR 및 DWI에서 양측으로 대칭적인 고신호 강도를 보였고, 그 중 1예에서만 T2 및 FLAIR 영상과 비교하여 DWI에서 명확하게 보였다. 결론 : HIE의 DWI 소견은 기저핵 및 대뇌 피질과 백질의 대칭적인 고신호 강도가 특징이며, T2 및 FLAIR영상보다 명확하였다.

  • PDF