• Title/Summary/Keyword: FIB-SEM

Search Result 52, Processing Time 0.023 seconds

The LaserFIB: new application opportunities combining a high-performance FIB-SEM with femtosecond laser processing in an integrated second chamber

  • Ben Tordoff;Cheryl Hartfield;Andrew J. Holwell;Stephan Hiller;Marcus Kaestner;Stephen Kelly;Jaehan Lee;Sascha Muller;Fabian Perez-Willard;Tobias Volkenandt;Robin White;Thomas Rodgers
    • Applied Microscopy
    • /
    • v.50
    • /
    • pp.24.1-24.11
    • /
    • 2020
  • The development of the femtosecond laser (fs laser) with its ability to provide extremely rapid athermal ablation of materials has initiated a renaissance in materials science. Sample milling rates for the fs laser are orders of magnitude greater than that of traditional focused ion beam (FIB) sources currently used. In combination with minimal surface post-processing requirements, this technology is proving to be a game changer for materials research. The development of a femtosecond laser attached to a focused ion beam scanning electron microscope (LaserFIB) enables numerous new capabilities, including access to deeply buried structures as well as the production of extremely large trenches, cross sections, pillars and TEM H-bars, all while preserving microstructure and avoiding or reducing FIB polishing. Several high impact applications are now possible due to this technology in the fields of crystallography, electronics, mechanical engineering, battery research and materials sample preparation. This review article summarizes the current opportunities for this new technology focusing on the materials science megatrends of engineering materials, energy materials and electronics.

A Study on the Tribolayer using Focused Ion Beam (FIB) (FIB를 이용한 트라이보층에 대한 연구)

  • Kim, Hong-Jin
    • Tribology and Lubricants
    • /
    • v.26 no.2
    • /
    • pp.122-128
    • /
    • 2010
  • Focused Ion Beam (FIB) has been used for site-specific TEM sample preparation and small scale fabrication. Moreover, analysis on the surface microstructure and phase distribution is possible by ion channeling contrast of FIB with high resolution. This paper describes FIB applications and deformed surface structure induced by sliding. The effect of FIB process on the surface damage was explored as well. The sliding experiments were conducted using high purity aluminum and OFHC(Oxygen-Free High Conductivity) copper. The counterpart material was steel. Pin-on-disk, Rotational Barrel Gas Gun and Explosively Driven Friction Tester were used for the sliding experiments in order to investigate the velocity effect on the microstructural change. From the FIB analysis, it is revealed that ion channeling contrast of FIB has better resolution than SEM and the tribolayer is composed of nanocrystalline structures. And the thickness of tribolayer was constant regardless of sliding velocities.

Development of a multi-functional nano-fabrication system for fabrication and measurement (가공 및 측정이 가능한 복합나노가공시스템의 개발)

  • 장동영;박만진;김진현;한동철
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2004.04a
    • /
    • pp.466-471
    • /
    • 2004
  • In focused-ion-beam (FIB) application of micromachining and device transplantation, four kinds of FIB processes, namely FIB sputtering, FIB-induced etching, redeposition, and FIB-induced deposition, are well utilized. As with FIB systems, scanning electron microscopes(SEMs) were extensively used in the semiconductor industry. They are the tools of choice for defect review and providing the image resolution needed for process monitoring. The enhanced capabilities of a dual-column on one chamber system are quickly becoming realized by the nano industry for performing a wide range of application.

  • PDF

Three Dimensional Reconstruction of Structural Defect of Thin Film Transistor Device by using Dual-Beam Focused Ion Beam and Scanning Electron Microscopy (집속이온빔장치와 주사전자현미경을 이용한 박막 트랜지스터 구조불량의 3차원 해석)

  • Kim, Ji-Soo;Lee, Seok-Ryoul;Lee, Lim-Soo;Kim, Jae-Yeal
    • Applied Microscopy
    • /
    • v.39 no.4
    • /
    • pp.349-354
    • /
    • 2009
  • In this paper we have constructed three dimensional images and examined structural failure on thin film transistor (TFT) liquid crystal display (LCD) by using dual-beam focused ion beam (FIB) and IMOD software. Specimen was sectioned with dual-beam focused ion beam. Series of two dimensional images were obtained by scanning electron microscopy. Three dimensional reconstruction was constructed from them by using IMOD software. The short defect between Gate layer and Data layer was found from the result of three dimensional reconstruction. That phenomena made the function of the gate lost and data signal supplied to the electrode though the Drain continuously. That signal made continuous line defect. The result of the three dimensional reconstruction, serial section, SEM imaging by using the FIB will be the foundation of the next advanced study.

A Site Specific Characterization Technique and Its Application

  • Kamino, T.;Yaguchi, T.;Ueki, Y.;Ohnish, T.;Umemura, K.;Asayama, K.
    • 한국전자현미경학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.18-22
    • /
    • 2001
  • A technique to characterize specific site of materials using a combination of a dedicated focused ion beam system(FIB), and Intermediate-voltage scanning transmission electron microscope(STEM) or transmission electron microscope(TEM) equipped with a scanning electron microscope(SEM) unit has been developed. The FIB system is used for preparation of electron transparent thin samples, while STEM or TEM is used for localization of a specific site to be milled in the FIB system. An FIB-STEM(TEM) compatible sample holder has been developed to facilitate thin sample preparation with high positional accuracy Positional accuracy of $0.1{\mu}m$ or better can be achieved by the technique. In addition, an FIB micro-sampling technique has been developed to extract a small sample directly from a bulk sample in a FIB system These newly developed techniques were applied for the analysis of specific failure in Si devices and also for characterization of a specific precipitate In a metal sample.

  • PDF

Design and Measurement of Nano-pattern for FIB Reliability Assessment (FIB 신뢰성 평가를 위한 나노패턴의 설계 및 측정)

  • Kang Hyun-Wook;Lee Seung-Jae;Cho Dong-Woo
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.24-29
    • /
    • 2005
  • Fm (Focused ion beam) system is one of the most important equipments for the nano-scale machining. Various researches have been performed, since it can etch the material and deposit 3-D structure with high-aspect-ratio in the nanometer scale. In spite of those researches, the definite method for the reliability of FIB system has not been reported. In this paper, we proposed the reliability assessment method through nano-pattern fabrication. In the fabricated nano-pattern, the characteristics of FIB system are included. Using this effect, we tried to assess the FIB reliability. First, we suggested reliability assessment items and nano-patterns. And, to know the suitableness of the proposed method, we fabricated several nano-patterns using Nova200(FEI Company) and SMI2050(SEIKO) which are FIB apparatuses. The fabricated nano-patterns are measured with SEM (Scanning Electron Microscope) and compared with designed dimensions. And the compared results showed that the proposed method is suitable for the assessment of FIB system reliability.

  • PDF

Study on Surface Damage of Specimen for Transmission Electron Microscopy(TEM) Using Focused Ion Beam(FIB) (집속 이온빔을 이용한 투과 전자 현미경 시편의 표면 영향에 관한 연구)

  • Kim, Dong-Sik
    • 전자공학회논문지 IE
    • /
    • v.47 no.2
    • /
    • pp.8-12
    • /
    • 2010
  • TEM is a powerful tool for semiconductor material analyses in structure or biological sample in micro structure. TEM observation need to make to coincide specimens for special purpose. in this paper, we have experimented for minimum surface damage on bulk wafer and patterned specimen by various conditions such as accelerating energy, depth of ion beam, ion milling types, and etc. in various specimen preparation methods by FIB (Focus Ion Beam). The optimal qualified specimens are contain low mounts of surface damage(about 5 nm) on patterned specimen.

Fabrication of Micro/nanoscale Cutting Tool Geometry of Single Crystal Diamond Tool by Focused Ion Beam (집속이온빔(Focused Ion Beam)에 의한 단결정 다이아몬드 공구의 마이크로/나노스케일 절삭공구 형상 제작)

  • Baek, Seung Yub;Jang, Sung Min
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.3
    • /
    • pp.207-213
    • /
    • 2014
  • A study was carried out to fabricate the cutting tool geometry with micro/nanoscale on the single crystal diamond tool by using the FIB. The FIB technique is an ideal tool for TEM sample preparation that allows for the fabrication of electron-transparent foils. The FIB is appropriate techniques to sample and subsequently define the chemical composition and the structural state of mineral inclusion on the micro/nanoscale. The combination of FIB with a SEM allows for 3D information to be obtained from samples including 3D imaging. Cutting strategies were demonstrated to improve the performance of cutting tool geometry and to generate high aspect ratio micro cutting tool. A finely focused beam of 30keV Ga+ ions was used to mill cutting tool shapes for various micro patterns. Therefore FIB sputtering is used to shape a variety of cutting tools with dimensions in the $1-5{\mu}m$ range and cutting edge radii of curvature of under 50nm.

Patterning and Characterization of Co/Ni Composite Silicide using EIB (FIB를 이용한 CoNi 복합실리사이드 나노배선의 패턴가공과 형상 분석)

  • Song Oh-Sung;Kim Sang-Yeob;Jung Yoon-Ki
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.3
    • /
    • pp.332-337
    • /
    • 2006
  • We prepared 100 nm-thick CoNi composite silicide on a 70 nm-thick polysilicon substrate. Composite silicide laye.s were formed by rapid thermal annealing(RTA) at the temperatures of $700^{\circ}C,\;900^{\circ}C,\;1000^{\circ}C$ for 40 seconds. A Focused ion beam (FIB) was used to make nano-patterns with the operation range of 30 kV and $1{\sim}100$ pA. We investigated the change of thickness, line width, and the slope angle of the silicide patterns by FIB. More easily made with the FIB process than with the conventional polycide process. We successfully fabricated sub-100nm etched patterns with FIB condition of 30kv-30pA. Our result implies that we may integrate nano patterns with our newly proposed CoNi composite silicides.

  • PDF

Structural Analysis and Manufacturing of the Integrated System using Ion Beam (이온 빔 이용 통합시스템의 제작 및 구조해석)

  • Kim, Seong-Keol
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.16 no.3
    • /
    • pp.88-95
    • /
    • 2007
  • Generally, the integrated system using ion beam consists of 4 major parts, which are SEM, FIB, nano stage, and chamber. Among them, the nano stage and the chamber are designed and manufactured. The whole systems are integrated. Also, FE models are built to perform modal analyses of each part and the whole integrated system with a commercial program. Through these analyses, it is found that each part and the integrated system are very safe against vibrations including external excitations from ground and any others, because their natural frequencies are much larger than frequencies of external excitations. Also, isolation of ground induced vibration is considered.