• Title/Summary/Keyword: FGD environment

Search Result 31, Processing Time 0.03 seconds

Evaluate Changes in Soil Chemical Properties Following FGD-Gypsum Application

  • Lee, Yong-Bok;Bigham, Jerry M.;Kim, Pil-Joo
    • Korean Journal of Environmental Agriculture
    • /
    • v.26 no.4
    • /
    • pp.294-299
    • /
    • 2007
  • Natural gypsum has been used as a soil amendment in the United States. However, flue gas desulfurization (FGD)-gypsum has not traditionally been used for agricultural purpose although it has potential benefit as a soil amendment. To expand use of FGD-gypsum for agricultural purpose, the effect of FGD-gypsum on soil chemical properties was investigated in the field scales. Application rates for this study were 0 (control), 1.1, and 2.2 Mg ha-1 of FGD-gypsum. After two year application, the soil samples were taken to 110 cm depth and sub-sampled at 10 cm intervals. The heavy metal contents in FGD-gypsum were lower than ceiling levels allowed by regulations for land-applied biosolids. Soil pH was not largely affected by FGD-gypsum application. Although degree of calcium (Ca) saturation in surface horizons increases only slightly with respect to the control, there is a clear decrease in exchangeable aluminum (Al). FGD-gypsum clearly increases the soil electrical conductivity (EC) with increasing application rate. Water-soluble Ca and sulfate is increased with FGD-gypsum application and these ions moved to a depth of at least 80 cm after only 2 years. We conclude that surface application of FGD-gypsum can mitigate toxicity of Al and deficiency of Ca in subsoil of acid soil.

Nitrate Removal of Flue Gas Desulfurization Wastewater by Autotrophic Denitrification

  • Liu, L.H.;Zhou, H.D.;Koenig, A.
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.46-52
    • /
    • 2007
  • As flue gas desulfurization (FGD) wastewater contains high concentrations of nitrate and is very low in organic carbon, the feasibility of nitrate removal by autotrophic denitrification using Thiobacillus denitrificans was studied. This autotrophic bacteria oxidizes elemental sulfur to sulfate while reducing nitrate to elemental nitrogen gas, thereby eliminating the need for addition of organic compounds such as methanol. Owing to the unusually high concentrations of dissolved salts $(Ca^{2+},\;Mg^{2+},\;Na^+,\;K^+,\;B^+,\;SO_4^{2-},\;Cl^-,\;F^-,)$ in the FGD wastewater, extensive laboratory-scale and pilot-scale tests were carried out in sulfur-limestone reactors (1) to determine the effect of salinity on autotrophic denitrification, (2) to evaluate the use of limestone for pH control and as source of inorganic carbon for microbial growth, and, (3) to find the optimum environmental and operational conditions for autotrophic denitrification of FGD wastewater. The experimental results demonstrated that (1) autotrophic denitrification is not inhibited up to 1.8 mol total dissolved salt content; (2) inorganic carbon and inorganic phosphorus must be present in sufficiently high concentrations; (3) limestone can supply effective buffering capacity and inorganic carbon; (4) the high calcium concentration may interfere with pH control, phosphorus solubility and limestone dissolution, hence requiring pretreatment of the FGD wastewater; and, 5) under optimum conditions, complete autotrophic denitrification of FGD wastewater was obtained in a sulfur-limestone packed bed reactor with a sulfur:limestone volume ratio of 2:1 for volumetric loading rates up to 400g $NO_{3^-}N/m^3.d$. The interesting interactions between autotrophic denitrification, pH, alkalinity, and the unusually high calcium and boron content of the FGD wastewater are highlighted. The engineering significance of the results is discussed.

  • PDF

Preparation of Calcium Sulfate α-Hemihydrate from FGD Gypum in the Autoclave (가압반응기를 이용한 배연탈황석고로부터 α형 반수석고의 생성)

  • Park, Seung-Soo;Kim, Ki-Hyoung;An, Hi-Soo;Park, Kwang-Kyu
    • Applied Chemistry for Engineering
    • /
    • v.17 no.6
    • /
    • pp.619-624
    • /
    • 2006
  • This study was performed to investigate the formation process of calcium sulfate ${\alpha}$-hemihydrate from FGD gypsum produced at thermal power plant burning bituminous coal. The experimental results showed that calcium sulfate $\alpha$-hemihydrate with a large aspect ratio was produced in the temperature range of $120^{\circ}C$ and $140^{\circ}C$ in the absence of additives through dissolution-recrystallization mechanism. It was also observed that addition of Na-succinate as a catalyst changed crystal shape from acicular to prismatic, resulting in decreased water/powder ratio down to 33%. Optimum concentration of Na-succinate was 20mM. It was confirmed that the optimum moulding pressure and moisture content of moulded body from FGD gypsum were $30kg_f/cm^2$ and between 10% and 15% respectively, which prevent moulded body from collapsing and maximize the capillary effect by given pore volume while autoclaving.

Mass Transfer of Sulfur Dioxide in Flue Gas Desulfurization Process Utilizing a Jet Bubbling Scrubber (기포분사반응기를 사용한 배연탈황공정의 아황산가스 물질전달)

  • 동종인;나진균;홍지형
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.8 no.4
    • /
    • pp.262-268
    • /
    • 1992
  • The trend of international concerns on environmental conservation and domestic demand of ambient air quality improvement, specially on sulfur dioxide level has resulted in the establishment of mid-term strategy of environmental improvement and stepwise strengthening of emission regulations in this decade in Korea. Development of flue gas desulfurization(FGD) process is becoming an essential task to be accomplished especially for the power plants and large industrial facilities. This study is an initial stage researc focusing on the mass transfer principles in wet type FGD process and the effects of operating variables of a jet bubbling scrubber utilizing limestone slurry on sulfur dioxide removal efficiency. Experimental results showed this type of scrubbing system has some advantages in terms of mass transfer mechanism and removal efficiency. More rigorous research is needed for the reaction system and the comparison with existing FGD processess for the possible development of a process which is compatative in view of installation cost and treatment of by-products.

  • PDF

A Study on the Coatings for CP System in the Environment in which Thin Layer of Extremely Acidic Fluids are Formed

  • Chang, H.Y.;So, I.S.;Jin, T.F.;Kim, Y.S.;Yoo, Y.R.;Kang, M.S.
    • Corrosion Science and Technology
    • /
    • v.5 no.1
    • /
    • pp.5-14
    • /
    • 2006
  • A lot of parts in FGD (Flue Gas Desulphurization) systems of fossil-fuel power plants show the environments in which are highly changeable and extremely acidic corrosive medium according to time and locations, e.g. in duct works, coolers and re-heaters etc.. These conditions are formed when system materials are immersed in fluid that flows on them or when exhausted gas is condensed into thin layered medium to contact materials of the system walls and roofs. The environments make troublesome corrosion and air pollution problems that are occurred from the leakage of the condensed solution. The frequent shut-down and repairing works of FGD systems also demand costs and low efficiencies of those facilities. In general, high corrosion resistant materials have been used to solve this problem. However, even the super alloys and Teflon linings sometimes have not been good enough to preventing corrosion. Further more, they are expensive and not easily repairable in short periods of operation stops. In this work, new technology that is effective, economical and easily repairable has proposed to solve the corrosion problems in FGD facilities. This technology contains cathodic protection, coatings and remote monitoring-controlling systems.

Practical Study of The Phenomenon and Removal of White Smoke for JBR FGD Plant (JBR FGD Plant에 있어서의 가시매연 발생원인 및 제거 방안 연구)

  • 전상기;조승원;황영호;이병규
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2000.11a
    • /
    • pp.273-273
    • /
    • 2000
  • 우리나라 대기환경기준은 이미 선진국 수준으로 강화되었거나 강화될 계획으로 있어 이에 따른 대기오염 방지시설의 설치 또는 보완이 요구되고 있다. 특히, 배기가스 중 황산화물 배출농도 강화로 황산화물 저감을 위한 배연탈황설비 설치ㆍ가동중에 있으나 황산 Mist가 주요원인으로 추정되는 Plume Opacity가 발생되어 대기 중에서 색깔을 띄게됨에 따라 오염물질 배출농도는 법적 규제기준 이내로 배출되더라도 인간의 심리적 불안감을 유발할 수 있어, 그 발생원인을 규명함과 동시에 현장여건에 적합한 최적의 황산 Mist 저감방법을 연구하고자 하였다. (중략)

  • PDF

Numerical Analysis on the Flue Gas Flow and Slurry Behavior in the Absorber of a Flue Gas Desulphurization (FGD) System (배연탈황설비 흡수탑 내 연소가스 및 슬러리의 거동에 관한 수치해석적 연구)

  • Choi, Choeng-Ryul
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.4
    • /
    • pp.478-486
    • /
    • 2007
  • Numerical analysis had been performed to understand flow characteristics of the flue gas and slurry in the absorber of a flue gas desulphurization (FGD) system using computational fluid dynamics (CFD) technique. Two-fluid(Euler-Lagrangian) model had been employed to simulate physical phenomenon, which slurry particles injected through slurry spray nozzles fall down and bump into the flue gas inflowing through inlet duct. It was not necessary to adopt pre-defined pressure drop inside the absorber because interaction between flue gas and slurry particles was considered. Hundreds of slurry spray nozzles were considered with the spray velocity at the nozzles, swirl velocity and spreading angle. The results note that the flow disturbance of flue gas is found at the bottom of the absorber, and the current rising with high speed stream is observed in the opposite region of the inflow duct. The high speed stream is reduced as the flue gas goes up, because the high speed stream of flue gas dumps falling slurry particles due to momentum exchange between flue gas and slurry particles. In spite of some disproportion in slurry distribution inside the absorber, escape of slurry particles from the absorber facility is not observed. The pressure drop inside the absorber is mainly occurred at the bottom section.

A Study on the Fluoro-polymer Composite Coatings for Protecting the Corrosion of Fossil-fuel Power Plants

  • Kang, Min Soo;Lee, Byung Seung;Chang, Hyun Young;Jin, Tae Eun;So, Il Soo
    • Corrosion Science and Technology
    • /
    • v.6 no.2
    • /
    • pp.62-67
    • /
    • 2007
  • Several heavy duty coatings at an every kind industry facilities to various systems currently have been applied review to the many industry fields. Corrosion-protective characteristics in the case of novolac epoxy among them and unsaturated polyester have been applied most widely. epoxy and flake heavy duty coatings are applied for such reason in an every kind facilities(stack, FGD, cooler, chemical tank etc) of a fossil-fuel power plants Cases of the fossil-fuel power plants are exposed to more severe corrosion environment compared with other facilities and It is difficult to display the performance of long-term method at apply to be the partial. Our study shows fluoro-polymer composite coating method to overcome of the limit. The comparison did previous method and heavy duty coating about FGD plants most at a corrosion environment among fossil-fuel power plants. Additionally, other facilities examined different heavy duty method. The design mode of fluoro-polymer composite coating according to an every kind facilities show extensive methods that are characteristic revelation of film(top, middle and primer layer) composition of the paint, film thickness in accordance with a facilities corrosion and the corrosion protective effectiveness to come into being use fluoro-polymer composite with heavy duty paint(epoxy).

Comparative Study of Ni effect on the Corrosion Behavior of Low Alloy Steels in FGD and Acid Rain Environments (산성비 및 배연탈황설비 환경에서 Ni 첨가에 따른 저합금강의 내식성 비교연구)

  • Han, Jun-Hee;Nguyen, Dang-Nam;Jang, Young-Wook;Kim, Jung-Gu
    • Korean Journal of Metals and Materials
    • /
    • v.47 no.9
    • /
    • pp.558-566
    • /
    • 2009
  • The alloying effect of a small amount of nickel on low alloy steel for application to flue gas desulfurization(FGD) systems was studied. The structural characteristics of the rust layer were investigated by scanning electron microscopy(SEM). The electrochemical properties were examined by means of potentiostatic polarization test, potentiodynamic polarization test, and electrochemical impedance spectroscopy(EIS) in a modified green death solution of 16.9 vol.% $H_2SO_4$+0.35 vol.% HCl at $60^{\circ}C$ and an acid rain solution of $6.25{\times}10^{-5}M\;H_2SO_4+5.5{\times}10^{-3}M\;NaCl$ at room temperature. It was found that as the amount of nickel increased, the corrosion rate increased in the modified green death solution, which seemed to result from micro-galvanic corrosion between NiS and alloy matrix. In acid rain solution, the corrosion rate decreased as the amount of nickel increased due to the repulsive force of $NiFe_2O_4$ rust against $Cl^-$ ions by electronegativity.