A study on the DSP Analysis for the CAT application (CAT 응용을 위한 신호처리 분석에 관한 연구)

  • Jeon, Dong-Keun
    • The Journal of the Acoustical Society of Korea
    • /
    • v.14 no.2
    • /
    • pp.30-39
    • /
    • 1995
  • In this paper, study on implementation of FFT analyzer applied to CAT, A/D conversion module, DSP module and VXIbus interface module are implemented in hardware and calculation program and control software are implemented in DSP module and VXIbus interface module, respectively. The control of the modules using PC is realized in software. The real time bandwidth of the FFT analyzing device is 100KHz. At sampling rate of 200KHz and with 2048 point FFT, the result of applying sine, triangular and rectangular wave of 20KHz to FFT analyzing device is compared with the FFT analyzed results of Hewlett-Packard 3562A dynamic output range of -40dBV- +30dBV, correct results are obtained and results of applying 10KHz, 20KHz and 50KHz input are compared and the correct values are obtained.

  • PDF

A Study on the Analysis Method of Tracking Process using Voltage Waveforms (전압파형을 이용한 트래킹 진전과정 분석방법에 관한 연구)

  • Jee, Sung-Wook;Lee, Chun-Ha;Yoon, Dae-Hee;Song, Hyun-Jik;Shim, Kwang-Yul;Park, Won-Ju;Lee, Kwang-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.8
    • /
    • pp.30-35
    • /
    • 2006
  • Voltage is generally and exactly measured in the electric and electronic field. So, we studied method for detecting electric equipment faulty state using only electric voltage. It is called the Partition-FFT. Tracking is simulated by method and tester proceed on IEC 60112. We analyze voltage waveforms by tracking tester with Partition-FFT. As the result tracking process is clearly distinguished by 6 steps. Tracking is one of the major reason of electric accidents. The Partition-FFT is using a digital oscilloscope and a computer software. If Partition-FFT analysis is applied to the electricity facilities, We can prevent from happenning electric accidents cause of tacking breakdown with low prices and easy measurment. Most of all, Partition-FFT is system that make a visual tacking process. So, everyone is able to detect to possibility of electric accidents.

Increment of fructan biosynthesis in rice by transformation of 1-sst and 1-fft genes isolated from jerusalem artichoke (Helianthus tuberosus L.) (돼지감자 유래 1-sst와 1-fft 유전자의 형질전환 발현에 의한 벼의 fructan 생합성 증진)

  • Kang, Kwon-Kyoo;Song, Beom-Heon;Lee, Gyong-A;Lee, Hye-Jung;Park, Jin-Ha;Jung, Yu-Jin;Cho, Yong-Gu
    • Journal of Plant Biotechnology
    • /
    • v.37 no.1
    • /
    • pp.102-109
    • /
    • 2010
  • Fructan has been found to accumulate in various tissues during periods when light levels increased carbon fixation where low temperatures reduced growth rates while photosynthesis continued. In this study, we have cloned 1-sucrose:sucrose fructosyl transferase(1-sst) and 1-fructan: fructan fructosyl transferase (1-fft, a key enzyme for the synthesis of fuctan) from Jerusalem Artichoke (Helianthus tuberosus L.). The recombinant vector with 1-sst and 1-fft has been constructed under the control of 35S promoter of KJGV-B2 vector and transgenic plants obtained by Agrobacterium tumefaciens LBA4404. PCR analysis carried out on the putative transgenic plants for amplification of the coding region of specific gene (1-sst, 1-fft), and HPT genes. Transgenic lines carrying of 1-sst and 1-fft were confirmed for integration into the rice genome using Southern blot hybridization and RT-PCR. The transgenic plants in $T_2$ generation were selected and expression pattern analysis revealed that 1-sst and 1-fft were stable. This analysis confirmed the presence of low-molecular-weight fructan in the seedling of the transgenic rices. Therefore, cold tolerance and carbohydrate metabolism will be possible to develop resistant plants using the transgenic rice.

Feature detection of peaks of sound signal using MEM (최대 엔트리법을 이용한 음향 신호의 특징 피크의 검출)

  • 성종훈;김영길
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 1998.11a
    • /
    • pp.562-564
    • /
    • 1998
  • 보통 음향 신호를 분석을 할 때에 시간영역의 신호를 주파수영역의 신호로 FFT 변환을 해서 분석을 한다. 이렇게 단순히 FFT를 해서 주파수영역의 신호에서 어떤 특징적인 점을 찾기가 매우 어렵다. 그래서 원 신호를 FFT를 하지 않고 선형 예측 분석이라는 방법을 적용하여 신호에 특징적인 피크 점들을 구하면 쉬운 방법이 된다. 본 논문에서는 이러한 음향의 신호를 분석을 할 때에 선형 예측 분석법을 이용하면 신호에서 특징적인 피크들을 구하기가 용이함을 보이고 신호의 특징 피크 점들을 통계적으로 처리하여 분석을 해보았다.

  • PDF

The Study of Muscle Fatigue Index Searching in terms of Median Frequency Analysis of EMG Signals during Isotonic Exercise (등장성운동 시 근전도 신호의 중앙주파수 분석을 통한 근피로지수 검출에 관한 연구)

  • 홍수용;이성호;윤형로;조상현
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.3
    • /
    • pp.175-181
    • /
    • 2003
  • Studies of muscle fatigue have mostly been checked under isometric exercise. However EMG signals from isotonic exercise generate uncontrollable noise, so there were difficulties in gathering reliable median frequency and muscle fatigue index if frequency analysis was equally applied in isometric exercise. This study tried to compare the differences of muscle fatigue determinant variables in terms of median frequency searching methods of EMG signal, which was estimated in isotonic exercise. To accomplish this, we determined median frequency by using different FFT intervals and overlapping ration of consecutive FFT sections under the same EMG signal, and then searched for a linear regression line, and compared initial median frequency, slope, and muscle fatigue index which were variables under the linear regression line. In result of comparison, initial median frequency was more elevated as FFT exercise interval became larger. The slope of the linear regression line showed distinguishable decreasing tendency as FFT intervals were larger and overlapping sections were smaller. Significant tendency of muscle fatigue index in FFT interval was shown by high muscle fatigue index in specific FFT intervals.

A Study on Analysis of Beat Spectra in a Radar System (레이다 시스템에서의 비트 스펙트럼 분석에 관한 연구)

  • Lee, Jong-Gil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.10
    • /
    • pp.2187-2193
    • /
    • 2010
  • A specific radar system can be implemented more easily using the frequency modulated continuous wave comparing with the pulse Doppler radar. It also has the advantage of LPI (low probability of interception) because of the low power and wide bandwidth characteristics. These radars are usually used to cover the short range area and to obtain the high resolution measurements of the target range and velocity information. The transmitted waveform is used in the mixer to demodulate the received echo signal and the resulting beat signal can be obtained. This beat signal is analyzed using the FFT method for the purpose of clutter removal, detection of a target, extraction of velocity and range information, etc. However, for the case of short signal acquisition time, this FFT method can cause the serious leakage effect which disables the detection of weaker echo signals masked by strong side lobes of the clutter. Therefore, in this paper, the weighting window method is analyzed to suppress the strong side lobes while maintaining the proper main lobe width. Also, the results of FFT beat spectrum analysis are shown under various environments.

FFT based Monitoring System for Combustion Vibration Data Processing of Gas Turbine (가스터빈 연소진동 데이터 처리를 위한 FFT 기반의 모니터링 시스템)

  • Lee, Sang-Hyeok;Kang, Feel-Soon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.12
    • /
    • pp.2327-2334
    • /
    • 2007
  • This paper presents a method for improvement of communication speed and reduction of data storage space in gas turbine monitoring system to acquire, save, and display combustion vibration data. The proposed method implements FFT from sampled raw data. The FFT result data are encoded to be transferred to monitoring PC for storage. By this way, it can reduce data storage space. To display the received data, it needs inverse FFT to reconstruct original signal. To verify the validity and efficiency of the proposed scheme, computer-aided simulation are carried out. It includes the analyzed results the relationship between FFT's order and Gibb's Phenomenon. Finally, high-performance of the proposed method is proved by combustion experiment results using a prototype gas turbine.

SCPI(Standard Commands for Programmable Instrument) Commands for FFT Analysis (FFT 분석을 위한 SCPI(Standard Commands for Programmable Instrument) 명령어)

  • 노승환
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.1384-1387
    • /
    • 1996
  • SCPI(Standard Commands for Programmable Instrument) is a standard command sets designed for controlling various types of instruments. In order to control FFT(Fast Fourier Transform) analyzing device using SCPI it is required to support sweep measurement function. We defined SCPI command set for FFT analysis and developed parser of defined command set using lex(Lexical Analyzer Generator) and yacc(Yet Another Compiler Compiler). After developing FFT analyzing test was performed with that parser. Up to audible signal frequency the result of FFT analysis was accurate and that result was agree with that of conventional FFT analyzer. As a result it is proved that various types of instruments including sweep measurement instrument can be controlled with appropriate SCPI command sets. Also when developing new instruments the method used in this experiment will contribute to reducing the time required to develop the SCPI parser and increasing reliability.

  • PDF

Frequency-Time Analysis(Partition-FFT) for Tracking Detection (트래킹 검출을 위한 주파수-시간 분석(분할-FFT))

  • Jee S. W.;Lee S. H.;Kim Ch. N.;Lee C. H.;Lee K. S.
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.10
    • /
    • pp.530-538
    • /
    • 2004
  • A electromagnetic waves are used for sensing in insulation diagnosis at electric machine or equipment. When it a method, waves are transformed into the FFT(Fast Fourier Transform); a kind of the process for data transformation. In a general way, a scientist use frequncy band 30[㎒]~l[㎓] to applied field. If we are measured high frequency band, we will need to a high capacity hardware. Also a antenna has a fault on atmospheric phenomena, outside environment and the like. In this paper We proposed new method for detecting electric equipment faulty state using only electric voltage which is generally measured in the electric and electronic field. It is called the Partition-FFT The analytic method is this first divide measured voltage waves into equal parts, second each deal with give effect to the FFT, finally each results deal with a graphic method and gather graphic. We are compare Partition-FFT with discharge form by tracking tester. As the result it demonstrated that the Partition-FFT is applicable.