• Title/Summary/Keyword: FFDM

Search Result 9, Processing Time 0.029 seconds

A study of dose and image quality with Convergence FFDM and DBT using tissue-equivalent phantom in digital mammography (유방조직등가 팬텀을 이용한 디지털유방촬영장치의 FFDM과 DBT의 선량과 영상품질에 대한 융합 연구)

  • Yoo, Young-Sin;Han, Dong-Kyoon
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.2
    • /
    • pp.29-34
    • /
    • 2019
  • In this study, we measure dose against various density and thickness using phantom to compare FFDM to DBT of Digital mammography equipment and evaluate usefulness of DBT through compare the image quality of FFDM and DBT. We use mammography equipment, Selenia Dimensions ; this is able to examine breast by both FFDM and DBT, The results are that when the thickness of phantom is 6cm or more and density is 70% or more and the thickness of phantom is 7cm or more and density is 50% or more, AGD of DBT is lower than that of FFDM. The evaluation results of image quality are that in the tumor and small calcification group that composed by mammary tissue and fat, FFDM is great and in fibrin, DBT is great. But in the all thicknesses of BR3D phantom that reflected overlapped tissue of breasts, DBT is great in calcification group, fibrin and tumor. DBT is greater image quality and lower dose more than FFDM in Thick and high density breast, Therefore, DBT is more useful in Korean women's breast that is characterized dense breast than FFDM.

Digital Breast Tomosynthesis versus MRI as an Adjunct to Full-Field Digital Mammography for Preoperative Evaluation of Breast Cancer according to Mammographic Density

  • Haejung Kim;So Yeon Yang;Joong Hyun Ahn;Eun Young Ko;Eun Sook Ko;Boo-Kyung Han;Ji Soo Choi
    • Korean Journal of Radiology
    • /
    • v.23 no.11
    • /
    • pp.1031-1043
    • /
    • 2022
  • Objective: To compare digital breast tomosynthesis (DBT) and MRI as an adjunct to full-field digital mammography (FFDM) for the preoperative evaluation of women with breast cancer based on mammographic density. Materials and Methods: This retrospective study enrolled 280 patients with breast cancer who had undergone FFDM, DBT, and MRI for preoperative local tumor staging. Three radiologists independently sought the index cancer and additional ipsilateral and contralateral breast cancers using either FFDM alone, DBT plus FFDM, or MRI plus FFDM. Diagnostic performances across the three radiologists were compared among the reading modes in all patients and subgroups with dense (n = 186) and non-dense breasts (n = 94) according to mammographic density. Results: Of 280 patients, 46 (16.4%) had 48 additional (39 ipsilateral and nine contralateral) cancers in addition to the index cancer. For index cancers, both DBT plus FFDM and MRI plus FFDM showed sensitivities of 100% in the non-dense group. In the dense group, DBT plus FFDM showed lower sensitivity than that of MRI plus FFDM (94.6% vs. 99.6%, p < 0.001). For additional ipsilateral cancers, DBT plus FFDM showed specificity and positive predictive value (PPV) of 100% in the non-dense group, but sensitivity and negative predictive value (NPV) were not statistically different from those of MRI plus FFDM (p > 0.05). In the dense group, DBT plus FFDM showed higher specificity (98.2% vs. 94.1%, p = 0.005) and PPV (83.1% vs. 65.4%; p = 0.036) than those of MRI plus FFDM, but lower sensitivity (59.9% vs. 75.3%; p = 0.049). For contralateral cancers, DBT plus FFDM showed higher specificity than that of MRI plus FFDM (99.0% vs. 96.7%, p = 0.014), however, the other values did not differ (all p > 0.05) in the dense group. Conclusion: DBT plus FFDM showed an overall higher specificity than that of MRI plus FFDM regardless of breast density, perhaps without substantial loss in sensitivity and NPV in the diagnosis of additional cancers. Thus, DBT may have the potential to be used as a preoperative breast cancer staging tool.

Assessment of Detection Rate Applying the Digital Convergence Mammographic Imaging Methods(FFDM, DBT, BMRI): Based on Breast Density (디지털 융복합 유방 영상 검사기법(FFDM, DBT, BMRI)을 사용한 검출률 평가 : 유방밀도에 근거하여)

  • Jang, Eun-Hee;Goo, Eun-Hoe
    • Journal of Digital Convergence
    • /
    • v.15 no.5
    • /
    • pp.281-291
    • /
    • 2017
  • This study aimed to assess detection rate applying the mammographic imaging methods. The evaluation of the shape and margin of tumor was conducted by score oriented to 180 patients who had undergone FFDM, DBT and BMRI scans among breast cancer patients, and the number of calcification was classified by size. There was no significant difference between DBT and BMRI for tumors larger than 1 cm in low-density breasts and for tumors larger than 2 cm in high-density breasts. Moreover, as for the detection rate of number of fine calcification, the highest rate was observed in FFDM followed by DBT and BMRI in the order named regardless of size. In conclusion, DBT was able to be detected even without BMRI if the mass was larger than 1 cm in the low-density breast and larger than 2 cm in the high-density breast. The detection rate of calcification turned out to be the highest in FFDM followed by DBT regardless of size, and calcification was not observed by BMRI. The appropriate use of FFDM, DBT and BMRI with respect to mass tumor will contribute to serving as a guide to examination methods of reducing burden of patients.

Significance and Application of Digital Breast Tomosynthesis for the BI-RADS Classification of Breast Cancer

  • Cai, Si-Qing;Yan, Jian-Xiang;Chen, Qing-Shi;Huang, Mei-Ling;Cai, Dong-Lu
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.9
    • /
    • pp.4109-4114
    • /
    • 2015
  • Background: Full-field digital mammography (FFDM) with dense breasts has a high rate of missed diagnosis, and digital breast tomosynthesis (DBT) could reduce organization overlapping and provide more reliable images for BI-RADS classification. This study aims to explore application of COMBO (FFDM+DBT) for effect and significance of BI-RADS classification of breast cancer. Materials and Methods: In this study, we selected 832 patients who had been treated from May 2013 to November 2013. Classify FFDM and COMBO examination according to BI-RADS separately and compare the differences for glands in the image of the same patient in judgment, mass characteristics display and indirect signs. Employ Paired Wilcoxon rank sum test was used in 79 breast cancer patients to find differences between two examine methods. Results: The results indicated that COMBO pattern is able to observe more details in distribution of glands when estimating content. Paired Wilcoxon rank sum test showed that overall classification level of COMBO is higher significantly compared to FFDM to BI-RADS diagnosis and classification of breast (P<0.05). The area under FFDM ROC curve is 0.805, while that is 0.941 in COMBO pattern. COMBO shows relation of mass with the surrounding tissues, the calcification in the mass, and multiple foci clearly in breast cancer tissues. The optimal sensitivity of cut-off value in COMBO pattern is 82.9%, which is higher than that in FFDM (60%). They share the same specificity which is both 93.2%. Conclusions: Digital Breast Tomosynthesis (DBT) could be used for the BI-RADS classification in breast cancer in clinical.

Factors Affecting Breast Cancer Detectability on Digital Breast Tomosynthesis and Two-Dimensional Digital Mammography in Patients with Dense Breasts

  • Soo Hyun Lee;Mi Jung Jang;Sun Mi Kim;Bo La Yun;Jiwon Rim;Jung Min Chang;Bohyoung Kim;Hye Young Choi
    • Korean Journal of Radiology
    • /
    • v.20 no.1
    • /
    • pp.58-68
    • /
    • 2019
  • Objective: To compare digital breast tomosynthesis (DBT) and conventional full-field digital mammography (FFDM) in the detectability of breast cancers in patients with dense breast tissue, and to determine the influencing factors in the detection of breast cancers using the two techniques. Materials and Methods: Three blinded radiologists independently graded cancer detectability of 300 breast cancers (288 women with dense breasts) on DBT and conventional FFDM images, retrospectively. Hormone status, histologic grade, T stage, and breast cancer subtype were recorded to identify factors affecting cancer detectability. The Wilcoxon signed-rank test was used to compare cancer detectability by DBT and conventional FFDM. Fisher's exact tests were used to determine differences in cancer characteristics between detectability groups. Kruskal-Wallis tests were used to determine whether the detectability score differed according to cancer characteristics. Results: Forty breast cancers (13.3%) were detectable only with DBT; 191 (63.7%) breast cancers were detected with both FFDM and DBT, and 69 (23%) were not detected with either. Cancer detectability scores were significantly higher for DBT than for conventional FFDM (median score, 6; range, 0-6; p < 0.001). The DBT-only cancer group had more invasive lobular-type breast cancers (22.5%) than the other two groups (i.e., cancer detected on both types of image [both-detected group], 5.2%; cancer not detected on either type of image [both-non-detected group], 7.3%), and less detectability of ductal carcinoma in situ (5% vs. 16.8% [both-detected group] vs. 27.5% [both-non-detected group]). Low-grade cancers were more often detected in the DBT-only group than in the both-detected group (22.5% vs. 10%, p = 0.026). Human epidermal growth factor receptor-2 (HER-2)-negative cancers were more often detected in the DBT-only group than in the both-detected group (92.3% vs. 70.5%, p = 0.004). Cancers surrounded by mostly glandular tissue were detected less often in the DBT only group than in the both-non-detected group (10% vs. 31.9%, p = 0.016). DBT cancer detectability scores were significantly associated with cancer type (p = 0.012), histologic grade (p = 0.013), T and N stage (p = 0.001, p = 0.024), proportion of glandular tissue surrounding lesions (p = 0.013), and lesion type (p < 0.001). Conclusion: Invasive lobular, low-grade, or HER-2-negative cancer is more detectable with DBT than with conventional FFDM in patients with dense breasts, but cancers surrounded by mostly glandular tissue might be missed with both techniques.

Diagnostic Performance of Digital Breast Tomosynthesis with the Two-Dimensional Synthesized Mammogram for Suspicious Breast Microcalcifications Compared to Full-Field Digital Mammography in Stereotactic Breast Biopsy (정위적 유방 조직검사 시 미세석회화 의심 병변에서의 디지털 유방단층영상합성법과 전역 디지털 유방촬영술의 진단능 비교)

  • Jiwon Shin;Ok Hee Woo;Hye Seon Shin;Sung Eun Song;Kyu Ran Cho;Bo Kyoung Seo
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.5
    • /
    • pp.1090-1103
    • /
    • 2022
  • Purpose To evaluate the diagnostic performance of digital breast tomosynthesis (DBT) with the two-dimensional synthesized mammogram (2DSM), compared to full-field digital mammography (FFDM), for suspicious microcalcifications in the breast ahead of stereotactic biopsy and to assess the diagnostic image visibility of the images. Materials and Methods This retrospective study involved 189 patients with microcalcifications, which were histopathologically verified by stereotactic breast biopsy, who underwent DBT with 2DSM and FFDM between January 8, 2015, and January 20, 2020. Two radiologists assessed all cases of microcalcifications based on Breast Imaging Reporting and Data System (BI-RADS) independently. They were blinded to the histopathologic outcome and additionally evaluated lesion visibility using a fivepoint scoring scale. Results Overall, the inter-observer agreement was excellent (0.9559). Under the setting of category 4A as negative due to the low possibility of malignancy and to avoid the dilution of malignancy criteria in our study, McNemar tests confirmed no significant difference between the performances of the two modalities in detecting microcalcifications with a high potential for malignancy (4B, 4C, or 5; p = 0.1573); however, the tests showed a significant difference between their performances in detecting microcalcifications with a high potential for benignancy (4A; p = 0.0009). DBT with 2DSM demonstrated superior visibility and diagnostic performance than FFDM in dense breasts. Conclusion DBT with 2DSM is superior to FFDM in terms of total diagnostic accuracy and lesion visibility for benign microcalcifications in dense breasts. This study suggests a promising role for DBT with 2DSM as an accommodating tool for stereotactic biopsy in female with dense breasts and suspicious breast microcalcifications.

The research on Full Field Digital Mammography Image Quality in PACS Environment (PACS환경에서 디지털유방엑스선 영상 화질에 관한 연구)

  • Jung, Jae-Ho
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.16 no.2
    • /
    • pp.25-29
    • /
    • 2014
  • The full-field digital mammography (FFDM), which has been known as a digital breast imaging system, carries out more outstanding performance than the screen-film mammography in overall image quality, skin & nipple, description of pectoral muscle and expression of micro-calcification. Thus, in this thesis, I perform experiments for both the enhancement of image quality and accurate estimation of the result in question, when detecting the very tiny-sized lesions in mammography. The image of digital breast X-rays is the important diagnostic tool for detecting early breast cancer and micro calcification lesion. The experiment of how much compression rate has an effect on the result of diagnosis in the case of microcalcification lesion, with JPEG2000 40:1 compression and over 50% enlargement led to obscure or definitely unacceptable diagnostic results is performed. And in another study of assessment of PSNR degree. I recognized the importance of standardized management system in mammography, where not to mention the accurate reading of the image has the most crucial role in diagnosis

  • PDF

Semi-automatic System for Mass Detection in Digital Mammogram (디지털 마모그램 반자동 종괴검출 방법)

  • Cho, Sun-Il;Kwon, Ju-Won;Ro, Yong-Man
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.2
    • /
    • pp.153-161
    • /
    • 2009
  • Mammogram is one of the important techniques for mass detection, which is the early diagnosis stage of a breast cancer. Especially, the CAD(Computer Aided Diagnosis) using mammogram improves the working performance of radiologists as it offers an effective mass detection. There are two types of CAD systems using mammogram; automatic and semi-automatic CAD systems. However, the automatic segmentation is limited in performance due to the difficulty of obtaining an accurate segmentation since mass occurs in the dense areas of the breast tissue and has smoother boundaries. Semi-automatic CAD systems overcome these limitations, however, they also have problems including high FP (False Positive) rate and a large amount of training data required for training a classifier. The proposed system which overcomes the aforementioned problems to detect mass is composed of the suspected area selection, the level set segmentation and SVM (Support Vector Machine) classification. To assess the efficacy of the system, 60 test images from the FFDM (Full-Field Digital Mammography) are analyzed and compared with the previous semi-automatic system, which uses the ANN classifier. The experimental results of the proposed system indicate higher accuracy of detecting mass in comparison to the previous systems.

Denoising of Digital Mammography Images Using Wavelet Transform (웨이블릿을 이용한 디지털유방영상의 노이즈 제거)

  • Choi, Seokyoon;Ko, Seongjin;Kang, Sesik
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.3
    • /
    • pp.181-189
    • /
    • 2013
  • The optimum exposure parameters are found when examined using the automatic mode in FFDM. improve the image quality by applying denoising algorithm and propose methods to reduce AGD(Average Grandular Dose) a patient can receive. For the experiment, Nuclear Associates Model 18-222 phantom was the used, and the entrance dose and AGD were measured. And then, Signal, Noise, SNR and FOM(Figure of Merit) were measured, compared and analyzed image denoising before and after. As the experiment result, first, SNR was the highest at Mo/Mo 23kVp and W/Rh 35kvp was the lowest for the average glandular dose. It showed to use 28kVp of W/Rh to be the best through the result of FOM. SNR was the highest at Mo/Mo 23kVp(image denoising), and it showed to W/Rh and 28kVp to be the best in the FOM result which AGD was considered at the same time. By the image denoising, it is possible to reduce noise while maintain important information in the image.