• Title/Summary/Keyword: FEM(finte element analysis)

Search Result 5, Processing Time 0.017 seconds

Near field Analysis of HTS Microstrip Antenna using Finte Element Method (유한요소법을 이용한 고온초전도 마이크로스트립 안테나 주변 저.자장 해석)

  • 정동철;박성진;허원일;한병성;구할본
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1995.11a
    • /
    • pp.324-327
    • /
    • 1995
  • In this research, FEM solution to analysis near field of high Tc superconductor microstrip antenna is presented. This method uses the interpolation function with vector edge triangular element. The advantage of this element is elimination of spurious solutions which are attributed to the lack of enforcement of the divergence condition. The solutions of this method will be used to have a good fundamental data for next reaserch about analysis of HTS microstrip array antenna etc.

  • PDF

Numerical Analysis of Eddy Currant Testing with Three Dimensional cracked Pipe by using Finte Element Method (유한요소법을 이용한 3차원 관결함의 와전류탐상 수치해석)

  • Won, Sung-Yean;Lee, Hyang-Beom;Shin, Young-Gil
    • Proceedings of the KIEE Conference
    • /
    • 1999.07a
    • /
    • pp.220-222
    • /
    • 1999
  • This paper presents a numerical analysis of the eddy current testing with cracked pipe using finite element method (FEM). ${\vec{A}},\;{\phi}-{\vec{A}}$ method is adopted for the formulation of 3-dimensional(3-D) FEM with the brick element. The cracks investigated here are the inner and outer surface of axial symmetry, 90 degree circular one. The algorithm of 3-D numerical analysis is employed for the axisymmetric pipe with the cracks. In order to verify the validity of 3-D numerical analysis, the results are compared with those of 2-D analysis with the same type of the model. The differential impedance is obtained by using energy method and its locus are various 8-shaped curves for each cracks. The ICCG method is used for the calculation of a matrix.

  • PDF

3-Dimensional Magnetic Field Analysis of Coil Using Biot-Savart Law Considering Singularity (특이점이 고려된 비오-사바르법을 이용한 3차원 코일의 자계 해석)

  • Song, Ho-Jun;Lee, Hyang-Beom
    • Proceedings of the KIEE Conference
    • /
    • 2005.10c
    • /
    • pp.104-106
    • /
    • 2005
  • In this paper, 3-dimensional magnetic field of coil is analyzed by using biot-sarvart law considering singularity. The RMSP(reduced magnetic scalar potential) arc employed in order to reduce the number of unknown variables in FEM(Finte Element Analysis) or BEM(Boundary Element Method). It Is necessary to calculate magnetic field of souce current when RMSP is used. Biot-savart law is generally used. it is difficult to calculate the field when the source point is in inside the coil. To integrate using gaussian quadrature, the cross section of coil is divided considering the position of field point when field point is inside coil. The proposed method shows good agreement of magnetic field compared with FEMLAB, OPERA3D.

  • PDF

Research on MFL PIG Design for the Inspection of Underground Gas Pipeline (지하매설 가스관의 검사를 위한 누설자속탐상 PIG 설계에 관한 연구)

  • Park, Sang-Ho;Park, Gwan-Soo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.2
    • /
    • pp.177-186
    • /
    • 2002
  • This paper describes the magnetic flux leakage(MFL) type non-destructive testing(NDT) system to detect the 3D defects in underground gas pipe. Magnetic systems with permanent magnets and yokes are analyzed by 3D non-lineal finite element method(FEM) with optimum design. In case of under-saturation of gas pipe, sensing signals are too weak to detect. In case of over-saturation, the changes of the sensing signals are too low to detect the defects sensitively. So, the operating points of the magnetic system are optimized to increase the changes of the MFL signals. The effects of the depth and size of the defects on the sensing signals are analyzed to define the range and resolution of the MFL sensors. To increase the sensor's sensitivity, the back-yoke sensors are introduced and tested.

Research on MFL PIG Design for caustic and defect the Inspection of Underground Gas Pipeline (지하매설 가스관의 부식 및 결함 탐지를 위한 비파괴 누설 탐상시스템 개발에 관한 연구)

  • Park, Sang-Ho;Park, Gwan-Soo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.11-20
    • /
    • 2002
  • This paper describes the magnetic flux leakage(MFL) type non-destructive testing(NDT) system to detect the 3D defects on underground gas pipe. Magnetic systems with permanent magnets and yokes are analyzed by 3D non-lineal finite element method(FEM) with optimum design. In case of under-saturation of gas pipe, sensing signals are too weak to detect. In case of over-saturation, the changes of the sensing signals are too low to detect the defects sensitively. So, the operating points of the magnetic system are optimized to increase the changes of the MFL signals. The effects of the depth and size of the defects on the sensing signals are analyzed to define the range and resolution of the MFL sensors. To increase the sensor's sensitivity, the back-yoke sensors are introduced and tested.

  • PDF