• Title/Summary/Keyword: FEA Model

Search Result 551, Processing Time 0.024 seconds

3-D FEA on the intrusion of mandibular anterior segment using orthodontic miniscrews (교정용 미니스크류를 이용한 하악 전치 함입 시 변위양상의 3차원 유한요소분석)

  • Park, Hyun-Kyung;Sung, Eui-Hyang;Cho, Young-Soo;Mo, Sung-Seo;Chun, Youn-Sic;Lee, Kee-Joon
    • The korean journal of orthodontics
    • /
    • v.41 no.6
    • /
    • pp.384-398
    • /
    • 2011
  • Objective: The purpose of this study was to analyze the stress distribution and the displacement pattern of mandibular anterior teeth under various intrusive force vectors according to the position of orthodontic miniscrews and hooks, using three-dimensional finite element analysis. Methods: A three-dimensional finite element model was constructed to simulate mandibular teeth, periodontal ligament, and alveolar bone. The displacement of individual tooth on three-dimensional planes and the von Mises stress distribution were compared when various intrusion force vectors were applied. Results: Intrusive forces applied to 4 mandibular anterior teeth largely resulted in remarkable labial tipping of the segment according to the miniscrew position. All 6 mandibular anterior teeth were labially tipped and the stress concentrated on the labiogingival area by intrusive force from miniscrews placed mesial to the canine. The distointrusive force vector led to pure intrusion and the stress was evenly distributed in the whole periodontal ligament when the hook was placed between the central and lateral incisors and the miniscrew was placed distal to the canine. Conclusions: Within the limits of this study, it can be concluded that predictable pure intrusion of the 6 anterior teeth segment may be accomplished using miniscrews placed distal to the canine and hooks located between the central and lateral incisors.

Development of Designed Formulae for Predicting Ultimate Strength of the Perforated Stiffened Plate subjected to Axial Compressive Loading (압축하중을 받는 유공보강판 구조의 최종강도 설계식 개발)

  • Park, Joo-Shin;Ko, Jae-Yong;Lee, Kyung-Hwan
    • Journal of Navigation and Port Research
    • /
    • v.31 no.5 s.121
    • /
    • pp.435-445
    • /
    • 2007
  • Ship structures are thin-walled structures and lots of cutouts, for example, of inner bottom structure, girder, upper deck hatch, floor and dia-frame etc. In the case where a plate has cutout it experiences reduced buckling and ultimate strength and at the same time the in-plane stress under compressive load produced by hull girder bending will be redistributed. In the present paper, we investigated several kinds of perforated stiffened model from actual ship structure and series of elasto-plastic large deflection analyses were performed to investigate into the influence of perforation on the buckling and ultimate strength of the perforated stiffened plate varying the cutout ratio, web height, thickness and type of cross-section by commercial FEA program(ANSYS). Closed-form formulas for predicting the ultimate strength of the perforated stiffened plate are empirically derived by curve fitting based on the Finite Element Analysis results. These formulas are used to evaluate the ultimate strength, which showed good correlation with FEM results. These results will be useful for evaluating the ultimate strength of the perforated stiffened plate in the preliminary design.

A Study on Rotation Behavior of High Strength Steel Endplate Connections under Fire (화재시 고강도강 엔드플레이트 접합부의 회전 거동에 관한 연구)

  • Shin, Su-Min;Lee, Chy-Hyoung;Yoon, Sung-Kee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.5
    • /
    • pp.35-43
    • /
    • 2016
  • In order to understand rotation behavior of high strength steel endplate connections under fire, this study is compared with existing studies conducted using FEA program. Eurocode 3 presents the three failure modes according to the prediction of bending resistance moment. The parameters of analysis model are temperature, thickness and steel materials of endplate. The rotation stiffness, and bending resistance moment are analyzed according to the parameters. The change of rotation stiffness and bending resistance moment are analyzed about the parameters, regression equations are suggested the change of high strength steel endplate connections. Consequently, the regression equations were proposed as the linear and quadratic equation. The moment ratio of high strength steel under fire was more reduced than the carbon steel, and was small effect about the thickness. When the high strength steel under fire was compared with at ambient temperature, the slope of initial rotation stiffness reduced, the increment ratio of moment was slow, and the change of plastic rotation stiffness wasn't effect by the thickness increase.

Effects of occlusal load on the stress distribution of four cavity configurations of noncarious cervical lesions: A three-dimensional finite element analysis study (네 가지 형태의 비우식성 치경부 병소의 3차원 유한요소법적 응력분석)

  • Jeon, Sang-Je;Park, Jeong-Kil;Kim, Hyeon-Cheol;Woo, Sung-Gwan;Kim, Kwang-Hoon;Son, Kwon;Hur, Bock
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.5
    • /
    • pp.359-370
    • /
    • 2006
  • The objective of this study was to investigate the effect of excessive occlusal loading on stress distribution on four type of cervical lesion, using a three dimensional finite element analysis (3D FEA). The extracted maxillary second premolar was scanned serially with Micro-CT. The 3D images were processed by 3D-DOCTOR. ANSYS was used to mesh and analyze 3D FE model. Four different lesion configurations representative of the various types observed clinically for teeth were studied. A static point load of 500N was applied to the buccal and lingual cusp (Load A and B). The principal stresses in lesion apex, and vertical sectioned margin of cervical wall were analyzed. The results were as follows 1. The patterns of stress distribution were similar but the magnitude was different in four types of lesion 2. The peak stress was observed at mesial corner and also stresses concentrated at lesion apex. 3. The compressive stress under load A and the tensile stress under load B were dominant stress. 4. Under the load, lesion can be increased and harmful to tooth structure unless restored.

Assessment of the Internal Pressure Fragility of the PWR Containment Building Using a Nonlinear Finite Element Analysis (비선형 유한요소 해석을 이용한 PWR 격납건물의 내압 취약도 평가)

  • Hahm, Daegi;Park, Hyung-Kui;Choi, In-Kil
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.27 no.2
    • /
    • pp.103-111
    • /
    • 2014
  • In this study, the probabilistic internal pressure fragility analysis was performed by using the non-linear finite element analysis method. The target structure is one of the containment buildings of typical domestic pressurized water reactors(PWRs). The 3-dimensional finite element model of the containment building was developed with considering the large equipment hatches. To consider uncertainties in the material properties and structural capacities, we performed the sensitivity analysis of the ultimate pressure capacity with respect to the variation of four important uncertain parameters. The results of the sensitivity analysis were used to the selection of the probabilistic variables and the determination of their probabilistic parameters. To reflect the present condition of the tendon pre-stressing force, the data of the pre-stressing force acquired from the in-service inspections of tendon forces were used for the determination of the median value. Two failure modes(leak, rupture) were considered and their limit states were defined to assess the internal pressure fragility of target containment building. The internal pressure fragilities for each failure mode were evaluated in terms of median internal pressure capacity, high confidence low probability of failure(HCLPF) capacity, and fragility curves with respect to the confidence levels. The HCLPF capacity was 115.9 psig for leak failure mode, and 125.0 psig for rupture failure mode.

Failure Stress Analysis of Bendable Embeded Electronic Module Based on Physics-of-Failure(PoF) (PoF 기반 Bendable Embeded 전자모듈의 스트레스 인자 해석)

  • Hong, Won-Sik;Oh, Chul-Min;Park, No-Chang;Han, Chang-Woon;Kim, Dae-Gon;Hong, Sung-Taik;Choi, Woo-Suk;Kim, Joong-Do
    • Proceedings of the KWS Conference
    • /
    • 2009.11a
    • /
    • pp.71-71
    • /
    • 2009
  • 전자제품의 다양한 기능들의 융복합화 및 휴대 편의성 경향은 이제 더 이상 새로운 것이 아니다. 이러한 추세에 따라 전자부품들은 모듈화 되고, 휴대하기 용이해 지고 있다. 또한 다양한 제품 디자인에 적용하기 위해 제품에 장착되는 부품의 기구적 위치 배열의 한계 또한 제약 받고 있다. 따라서 최근의 전자부품은 모듈화 되고 있으며, 기구적 한계를 극복하기 위한 Flexible 모듈의 사용이 증가하고 있다. 또한 양산측면에서 Roll-to-Roll(R2R) 방식을 적용함으로써 생산성을 극대화 하고 있다. 이때 R2R 적용을 위해서는 제품이 굴곡 될 수 있도록 유연성이 보장되는 Bendable 전자모듈의 개발이 필수적으로 요구되고 있다. Flexible 기판은 더 이상 새로운 기술이 아니지만, Felxible 기판 내부에 칩이 내장되고, 회로가 형성되어 자체적으로 기능을 수행할 수 있도록 한 Bendable 전자모듈을 R2R 방식으로 제조하는 기술은 매우 새로운 접근이라 할 수 있다. 이러한 기술개발이 현실화 된다면, Wearable Electronics 및 Flexible Display 등 다양한 전자제품에 응용될 수 있을 것으로 기대된다. 그러나 이러한 제품의 상용화를 위해서는 Bendable 전자모듈에 대한 신뢰성이 확보되고, 제품으로써의 수명이 보증되어야 한다. 신규 개발되는 제품의 신뢰성 검증항목이나 수명평가 모델은 현재까지 제안되지 않고 있는 실정이다. 또한 다양한 사용 환경에서 고장(Failure) 발생을 유발하는 스트레스 인자(Stress Factor)를 도출함으로써, 가속시험 또는 신뢰성 검증을 위한 인가 스트레스를 선정할 수 있다. 그러나 이러한 고장물리를 기반으로 스트레스 인자를 해석한 결과는 아직 보고되고 있지 않다. 따라서 본 연구에서는 $50{\mu}m$ 두께의 Si Chip에 저항변화를 관찰하기 위한 회로를 형성한 후 폴리이미드 기판을 이용하여 Si Chip이 임베딩된 Bendable 전자모듈을 제작하였다. 전자모듈의 실사용 환경에서의 수명예측을 위한 사전단계로써 고장물리에 기반한 고장모드와 고장메카니즘을 해석하는 것이 최우선 수행되어야 하며, 이를 바탕으로 고장을 유발하는 스트레스 인자를 도출 하였다. 고장도출을 위해 시제품은 JEDEC J-STD-020C의 MSL시험, 고온가압시험, 열충격시험 및 고온저장시험을 각각 수행하였으며, 이로부터 발생된 각각의 고장유형을 분석함으로써 스트레스 인자를 도출하였다. 또한 모아레(Moire) 간섭계를 이용하여 제작된 샘플의 온도변화에 따른 변형해석을 수행하였고, 동시에 Half Symetry Model을 이용한 유한요소해석(FEA)을 수행하여 변형해석 및 스트레스 유발원인을 도출하였다. 이 결과로 부터 고장물리 기반의 고장해석과 Moire 분석 그리고 시뮬레이션 해석 결과를 바탕으로 Bendable 전자모듈의 고장유발 스트레스 인자를 해석할 수 있었다.

  • PDF

Physiochemical characteristics and fermentation ability of milk from Czech Fleckvieh cows are related to genetic polymorphisms of β-casein, κ-casein, and β-lactoglobulin

  • Kyselova, Jitka;Jecminkova, Katerina;Matejickova, Jitka;Hanus, Oto;Kott, Tomas;Stipkova, Miloslava;Krejcova, Michaela
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.32 no.1
    • /
    • pp.14-22
    • /
    • 2019
  • Objective: The aim of the study was to find a possible association between the ${\beta}-$ and ${\kappa}-casein$ and ${\beta}-lactoglobulin$ genotypes and important milk physiochemical and technological characteristics such as acidity, alcohol stability, the contents of some minerals and the parameters of acid fermentation ability (FEA) in Czech Fleckvieh Cattle. Methods: Milk and blood samples were collected from 338 primiparous Czech Fleckvieh cows at the same stage of lactation. The genotypes of individual cows for ${\kappa}-casein$ (alleles A, B, and E) and ${\beta}-lactoglobulin$ (alleles A and B) were ascertained by polymerase chain reaction-restriction fragment length polymorphism, while their ${\beta}-casein$ (alleles $A^1$, $A^2$, $A^3$, and B) genotype was determined using melting curve genotyping analysis. The data collected were i) milk traits including active acidity (pH), titratable acidity (TA), alcohol stability (AS); calcium (Ca), phosphorus (P), sodium (Na), magnesium (Mg), and potassium (K) contents; and ii) yoghurt traits including active acidity (Y-pH), titratable acidity (Y-TA), and the counts of both Lactobacilli and Streptococci in 1 mL of yoghurt. A linear model was assumed with fixed effects of herd, year, and season of calving, an effect of the age of the cow at first calving and effects of the casein and lactoglobulin genotypes of ${\beta}-CN$ (${\beta}-casein$, CSN2), ${\kappa}-CN$ (${\kappa}-casein$, CSN3), and ${\beta}-LG$ (${\beta}-lactoglobulin$, LGB), or the three-way interaction between those genes. Results: The genetic polymorphisms were related to the milk TA, AS, content of P and Ca, Y-pH and Lactobacilli number in the fresh yoghurt. The CSN3 genotype was significantly associated with milk AS (p<0.05). The effect of the composite CSN2-CSN3-LGB genotype on the investigated traits mostly reflected the effects of the individual genes. It significantly influenced TA (p<0.01), Y-pH (p<0.05) and the log of the Lactobacilli count (p<0.05). Conclusion: Our findings indicate that the yoghurt fermentation test together with milk proteins genotyping could contribute to milk quality control and highlight new perspectives in dairy cattle selection.

Mechanical Modeling of Pen Drop Test for Protection of Ultra-Thin Glass Layer (초박형 유리층 보호를 위한 펜 낙하 시험의 기계적 모델링)

  • Oh, Eun Sung;Oh, Seung Jin;Lee, Sun-Woo;Jeon, Seung-Min;Kim, Taek-Soo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.29 no.3
    • /
    • pp.49-53
    • /
    • 2022
  • Ultra-thin glass (UTG) has been widely used in foldable display as a cover window for the protection of display and has a great potential for rollable display and various flexible electronics. The foldable display is under impact loading by bending and touch pen and exposed to other external impact loads such as drop while people are using it. These external impact loads can cause cracks or fracture to UTG because it is very thin under 100 ㎛ as well as brittle. Cracking and fracture lead to severe reliability problems for foldable smartphone. Thus, this study constructs finite element analysis (FEA) model for the pen drop test which can measure the impact resistance of UTG and conducts mechanical modeling to improve the reliability of UTG under impact loading. When a protective layer is placed to an upper layer or lower layer of UTG layer, stress mechanism which is applied to the UTG layer by pen drop is analyzed and an optimized structure is suggested for reliability improvement of UTG layer. Furthermore, maximum principal stress values applied at the UTG layer are analyzed according to pen drop height to obtain maximum pen drop height based on the strength of UTG.

Effect of Bone Quality on Insertion Torque during Implant Placement; Finite Eelement Analysis (임플란트 식립 시 골질이 주입회전력에 미치는 영향에 관한 삼차원 유한요소 분석)

  • Jeong, Jae Doug;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.2
    • /
    • pp.109-123
    • /
    • 2009
  • The aim of the study was to assess the influence of insertion torque of bone quality and to compare axial force, moment and von Mises stress using finite element analysis of plastoelastic property for bone stress and strain by dividing bone quality to its thickness of cortical bone, density of trabecular bone and existence of lower cortical bone when implant inserted to mandibular premolar region. The $Br{\aa}nemark$ MKIII. RP implant and cylindrical bone finite model were designed as cortical bone at upper border and trabecular bone below the cortical bone. 7 models were made according to thickness of cortical bone, density of trabecular bone and bicortical anchorage and von Mises stress, axial force and moment were compared by running time. Dividing the insertion time, it seemed 300msec that inferior border of implant flange impinged the upper border of bone, 550msec that implant flange placed in middle of upper border and 800msec that superior border of implant flange was at the same level as bone surface. The maximum axial force peak was at about 500msec, and maximum moment peak was at about 800msec. The correlation of von Mises stress distribution was seen at both peak level. The following findings were appeared by the study which compared the axial force by its each area. The axial force was measured highest when $Br{\aa}nemark$ MKIII implant flange inserts the cortical bone. And maximal moment was measured highest after axial force suddenly decreased when the flange impinged at upper border and the concentration of von Mises stress distribution was at the same site. When implant was placed, the axial force and moment was measured high as the cortical bone got thicker and the force concentrated at the cortical bone site. The influence of density in trabecular bone to axial force was less when cortical bone was 1.5 mm thick but it might be more affected when the thickness was 0.5 mm. The total axial force with bicortical anchorage, was similar when upper border thickness was the same. But at the lower border the axial force of bicortical model was higher than that of monocortical model. Within the limitation of this FEA study, the insertion torque was most affected by the thickness of cortical bone when it was placed the $Br{\aa}nemark$ MKIII implant in premolar region of mandible.

Effect of Tightening Torque on Abutment-Fixture Joint Stability using 3-Dimensional Finite Element Analysis (임플란트 지대주나사의 조임회전력이 연결부 안정성에 미치는 영향에 관한 3차원 유한요소해석 연구)

  • Eom, Tae-Gwan;Suh, Seung-Woo;Jeon, Gyeo-Rok;Shin, Jung-Wook;Jeong, Chang-Mo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.125-135
    • /
    • 2009
  • Statement of problem: Loosening or fracture of the abutment screw is one of the common problems related to the dental implant. Generally, in order to make the screw joint stable, the preload generated by tightening torque needs to be increased within the elastic limit of the screw. However, additional tensile forces can produce the plastic deformation of abutment screw when functional loads are superimposed on preload stresses, and they can elicit loosening or fracture of the abutment screw. Therefore, it is necessary to find the optimum tightening torque that maximizes a fatigue life and simultaneously offer a reasonable degree of protection against loosening. Purpose: The purpose of this study was to present the influence of tightening torque on the implant-abutment screw joint stability with the 3 dimensional finite element analysis. Material and methods: In this study, the finite element model of the implant system with external butt joint connection was designed and verified by comparison with additional theoretical and experimental results. Four different amount of tightening torques(10, 20, 30 and 40 Ncm) and the external loading(250 N, $30^{\circ}$) were applied to the model, and the equivalent stress distributions and the gap distances were calculated according to each tightening torque and the result was analyzed. Results: Within the limitation of this study, the following results were drawn; 1) There was the proportional relation between the tightening torque and the preload. 2) In case of applying only the tightening torque, the maximum stress was found at the screw neck. 3) The maximum stress was also shown at the screw neck under the external loading condition. However in case of applying 10 Ncm tightening torque, it was found at the undersurface of the screw head. 4) The joint opening was observed under the external loading in case of applying 10 Ncm and 20 Ncm of tightening torque. 5) When the tightening torque was applied at 40 Ncm, under the external loading the maximum stress exceeded the allowable stress value of the titanium alloy. Conclusion: Implant abutment screw must have a proper tightening torque that will be able to maintain joint stability of fixture and abutment.