• 제목/요약/키워드: FEA (Finite Element Analysis)

검색결과 1,119건 처리시간 0.026초

유한요소해석을 이용한 증육 모델의 성형특성 연구 (Study of Forming Properties for an Edge Thickening Model Using the Finite Element Method)

  • 조종두;김영진
    • 소성∙가공
    • /
    • 제21권4호
    • /
    • pp.234-239
    • /
    • 2012
  • This study examines the forming properties and forming loads needed to increase the edge thickness on the external face of a plate using finite element analysis(FEA). Recently, forming optimization techniques within FEA are being extensively used in designing the optimal forming conditions for processes like forging, extrusion, rolling, and spinning. Most of these existing forming operations involve reducing the volume per unit length, but research for increasing volume per unit length is not very extensive. For this study we chose an automotive engine flywheel which is a welded assembly of a plate and a gear with each component having a different thickness. We considered a forming technique to increase the thickness in order to allow the machining of the gear directly on the external face of plate alleviating the need for a weld. To study various forming techniques, we used the finite element method with the flow stress of material and incremental forming steps. We conclude from this study that the analysis of forming properties and forming loads by using the finite element analysis and testing is useful as a method to increase the thickness per unit length.

2차원 평면응력 상태에서 되풀이 소성역이 피로균열 열림 현상에 미치는 영향에 관한 연구 (An Evaluation on the Effect of Reversed Plastic Zone on the Fatigue Crack Opening Behavior under 2-D Plane Stress)

  • 최현창
    • 대한기계학회논문집A
    • /
    • 제29권8호
    • /
    • pp.1078-1084
    • /
    • 2005
  • The relationship between fatigue crack opening behavior and the reversed plastic zone sizes is studied. An elastic-plastic finite element analysis (FEA) is performed to examine the opening behavior of fatigue crack, where the contact elements are used in the mesh of the track tip area. The smaller element size than reversed plastic zone size is used fer evaluating the distribution of reversed plastic zone. In the author's previous results the FEA could predict the crack opening level, which crack tip elements were in proportion to the theoretical reversed plastic zone size. It is found that the calculated reversed plastic zone size is related to the theoretical reversed plastic zone size and crack opening level. The calculated reversed plastic zone sizes are almost equal to the reversed plastic zone considering crack opening level obtained by experimental results. It can be possible to predict the crack opening level from the reversed plastic zone size calculated by finite element method. We find that the experimental crack opening levels correspond with the opening values of contact nodes on the calculated reversed plastic zone of finite element simulation.

골수술용 압전형 초음파 의료기기 개발을 위한 유한요소해석 및 이의 실험적 검증 (Finite Element Analysis for the Development of Bone Surgery Piezoelectric Ultrasonic Medical Device and its Experimental Verification)

  • 송태하;이중호;최종균;이희원
    • 대한의용생체공학회:의공학회지
    • /
    • 제43권5호
    • /
    • pp.319-330
    • /
    • 2022
  • In this study, the optimal driving frequency was derived through finite element analysis (FEA) to optimize the developed piezoelectric ultrasonic medical devices(PUMD) for bone surgery. The core of the PUMD is the piezoelectric ceramic (PZT), which is a vibrator that generates vibration energy. The piezoelectric ceramic shows the maximum current value with respect to the input voltage at the resonance frequency, which generates the maximum mechanical vibration. In the past, various studies have been conducted related to the analysis of PUMD, but most of the research so far has been limited to free vibration analysis. However, in order to derive the accurate resonant frequency, the initial stress generated by bolt tightening in the bolt-clamped Langevin type transducer (BLT) must be considered. In this study, after designing a PUMD, the driving performance according to the bolt tightening value was analyzed through FEA, and this was experimentally verified. First, the resonance mode and frequency response were confirmed through modal and harmonic analysis at 20-40 kHz, which is known as the optimal driving frequency band of PUMD for bone surgery. In addition, the design of the PUMD was confirmed by checking the mechanical behavior of the tip and the piezoelectric ceramic at the resonant frequency. Consequentially, the characteristic evaluation was performed, and it was confirmed that the resonant frequency result derived through the FEA was reasonable. Through this study, we presented a more rational FEA method than before for BLT transducers. We expect that this will shorten the time and cost of developing a PUMD, and will enable the development of more stable and high-quality products.

Seismic performance of the concrete-encased CFST column to RC beam joints: Analytical study

  • Ma, Dan-Yang;Han, Lin-Hai;Zhao, Xiao-Ling;Yang, Wei-Biao
    • Steel and Composite Structures
    • /
    • 제36권5호
    • /
    • pp.533-551
    • /
    • 2020
  • A finite element analysis (FEA) model is established to investigate the concrete-encased concrete-filled steel tubular (CFST) column to reinforced concrete (RC) beam joints under cyclic loading. The feasibility of the FEA model is verified by a set of test results, consisting of the failure modes, the exposed view of connections, the crack distributions and development, and the hysteretic relationships. The full-range analysis is conducted to investigate the stress and strain development process in the composite joint by using this FEA model. The internal force distributions of different components, as well as the deformation distributions, are analyzed under different failure modes. The proposed connections are investigated under dimensional and material parameters, and the proper constructional details of the connections are recommended. Parameters of the beam-column joints, including material strength, confinement factor, reinforcement ratio, diameter of steel tube to sectional width ratio, beam to column linear bending stiffness ratio and beam shear span ratio are evaluated. Furthermore, the key parameters affecting the failure modes and the corresponding parameters ranges are proposed in this paper.

말뚝 인발모형실험에 대한 유한요소해석의 적용성 평가 (Evaluation on Applicability of Finite Element Analysis in Model Test of Pile Pullout)

  • 유승경;신희수;이광우;박정준;최충락;홍기권
    • 한국지반신소재학회논문집
    • /
    • 제18권2호
    • /
    • pp.11-21
    • /
    • 2019
  • 본 연구에서는 말뚝의 인발저항에 대한 합리적 평가를 위하여, 다양한 지반 조건(상대밀도, 세립분 함유율)에서 말뚝의 인발거동 모사에 대한 유한요소해석의 적용성을 평가하였다. 즉, 기존의 실내모형실험 결과(You et al., 2018)를 대상으로 동일한 조건에서의 유한요소해석을 실시하였고, 유한요소해석에 이용된 해석모델의 신뢰성을 검증하였다. 또한 수치해석을 활용한 말뚝의 인발거동 모사에 대한 적정성을 평가하였다. 그 결과, 가상지반이 적용된 축대칭 해석을 이용하여 말뚝의 주면마찰력을 평가할 수 있는 것으로 확인되었다. 또한 다양한 지반 조건에 대하여 말뚝-지반 경계면의 전단저항 특성을 반영할 수 있는 축대칭 해석은 말뚝의 합리적인 인발거동 모사가 가능한 해석방법으로 활용이 가능한 것으로 분석되었다. 따라서 본 연구를 통하여 제안된 해석모델은 말뚝의 응력-변형 관계를 통한 인발거동을 적절하게 모사할 수 있는 것으로 판단되었다.

Structural design of steel fibre reinforced concrete in-filled steel circular columns

  • Eltobgy, Hanan H.
    • Steel and Composite Structures
    • /
    • 제14권3호
    • /
    • pp.267-282
    • /
    • 2013
  • This paper presents the behavior and design of axially loaded normal and steel fiber reinforced concrete in-filled steel tube (SFRCFT) columns, to examine the contribution of steel fibers on the compressive strength of the composite columns. Non-linear finite element analysis model (FEA) using ANSYS software has been developed and used in the analysis. The confinement effect provided by the steel tube is considered in the analysis. Comparisons of the analytical model results, along with other available experimental outputs from literature have been done to verify the structural model. The compressive strength and stiffness of SFRC composite columns were discussed, and the interpretation of the FEA model results has indicated that, the use of SFRC as infill material has a considerable effect on the strength and stiffness of the composite column. The analytical model results were compared with the existing design methods of composite columns - (EC4, AISC/LRFD and the Egyptian code of Practice for Steel Construction, ECPSC/LRFD). The comparison indicated that, the results of the FEA model were evaluated to an acceptable limit of accuracy. The code design equations were modified to introduce the steel fiber effect and compared with the results of the FEA model for verification.

Thermal post-buckling analysis of uniform slender functionally graded material beams

  • Anandrao, K. Sanjay;Gupta, R.K.;Ramchandran, P.;Rao, G. Venkateswara
    • Structural Engineering and Mechanics
    • /
    • 제36권5호
    • /
    • pp.545-560
    • /
    • 2010
  • Two or more distinct materials are combined into a single functionally graded material (FGM) where the microstructural composition and properties change gradually. Thermal post-buckling behavior of uniform slender FGM beams is investigated independently using the classical Rayleigh-Ritz (RR) formulation and the versatile Finite Element Analysis (FEA) formulation developed in this paper. The von-Karman strain-displacement relations are used to account for moderately large deflections of FGM beams. Bending-extension coupling arising due to heterogeneity of material through the thickness is included. Simply supported and clamped beams with axially immovable ends are considered in the present study. Post-buckling load versus deflection curves and buckled mode shapes obtained from both the RR and FEA formulations for different volume fraction exponents show an excellent agreement with the available literature results for simply supported ends. Response of the FGM beam with clamped ends is studied for the first time and the results from both the RR and FEA formulations show a very good agreement. Though the response of the FGM beam could have been studied more accurately by FEA formulation alone, the authors aim to apply the RR formulation is to find an approximate closed form post-buckling solutions for the FGM beams. Further, the use of the RR formulation clearly demonstrates the effect of bending-extension coupling on the post-buckling response of the FGM beams.

발파 기폭 패턴에 따른 분할 단면의 최대주변형률 분석 (Analysis of the Maximum Principal Strain on the Splitting Surface by Blasting Detonation Pattern)

  • 송정언;김승곤;박훈
    • 화약ㆍ발파
    • /
    • 제37권2호
    • /
    • pp.1-13
    • /
    • 2019
  • 본 연구에서는 도심지 발파에서 형성되는 분할 단면의 변형을 확인하기 위해 Visual FEA 유한요소 프로그램으로 발파 단면을 모델링하여 발파 기폭 패턴에 따른 최대주변형률을 분석하였고, Visual FEA 유한요소 프로그램으로 분석된 분할 단면과 현장 발파로 형성된 분할 단면을 비교하였다. 결과적으로, 발파 기폭 패턴에 따라 분할 단면에서 최대주변형률의 차이를 나타냈고, 전산해석과 현장 발파에서 분할 단면이 유사한 파형 형태를 보이는 것으로 확인되었다.

Grillage Method Applied to the Planning of Ship Docking

  • Kim, Sung Chan;Ryu, Cheolho;Lee, Jang Hyun;Lee, Kyung Seok
    • Journal of Advanced Research in Ocean Engineering
    • /
    • 제2권3호
    • /
    • pp.150-157
    • /
    • 2016
  • When blocks are supported on a dock, huge reaction forces concentrated at the supports cause structural damage owing to local stress concentrations. Thus, the supports should be arranged to avoid local failure from the reaction forces by redistributing those forces. Docking analyses to determine the proper blocks and their support arrangements are introduced so that the local stresses are minimized to warrant the safety of the docking supports. Local stresses enforced by the support arrangement should be evaluated by finite element analysis (FEA). However, it is difficult to consider an accurate 3D geometry of the blocks in the finite element model because the structural design information is too complicated to determine within several days using the FEA model. This paper presents a simplified FE model to evaluate the safety of the arrangement of supports using a simplified grillage element. The grillage element can be efficiently used to obrain the reaction forces in docking analysis becasuse the reaction forces at the supports are enough to assess the safety of block. Since a simplified grillage model of the entire ship cannot accurately calculate the local stresses, an optimized modeling method based on the grillage element was introduced. The local reaction forces obtained by the proposed approach and three-dimensional FEA were discussed for typical types of ships. It is shown that the reaction forces obtained by the present grillage model are in reasonably good agreement with the FEA model.

Dynamic Response Measurement of the Head Arm Assembly of a Hard Disk Drive by Numerical Analysis and Experiments

  • Parlapalli, Madhusudhana R;Bin, Gu;Dongwei, Shu;Fujii, Yusaku
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제9권4호
    • /
    • pp.22-25
    • /
    • 2008
  • The dynamic response of the head arm assembly (HAA) of a hard disk drive to an impact load was obtained from a 3D non-linear finite element model using ANSYS/LS-DYNA and from experiments using a modified levitation mass method (LMM). In the finite element model, the impact load was created by modeling the mass as a rigid body and making it collide with the HAA. The velocity, displacement, acceleration, and inertial force of the mass were then obtained from the time history data of the finite element analysis. In the LMM, a mass that was levitated with an aerostatic linear bearing, and hence encountered negligible friction, was made to collide with the actuator arm, resulting in a dynamic bending test for the arm. During the collision, the Doppler frequency shift of the laser beam reflected from the mass was accurately measured with an optical interferometer. The velocity, displacement, acceleration, and inertial force of the mass were accurately calculated from the measured time-varying Doppler frequency shift. A good correlation between the experimental data and FEA results was observed. The FEA was also used to investigate the dynamic response of the HAA to impact by different masses.