Park, Hee-Won;Cho, Jae-Ho;Mun, Sun-Yeo;Park, Chung-Hwa;Hwang, Cheol-Hong;Kim, Sung-Chan;Nam, Dong-Gun
Fire Science and Engineering
/
v.28
no.1
/
pp.37-43
/
2014
The high predictive performance of fire detector models is essentially needed to assure the reliability of fire and evacuation modeling in the process of Performance-Based fire safety Design (PBD). The main objective of the present study is to measure input information in order to predictive the accurate activation time of fixed temperature heat detectors adopted in Fire Dynamics Simulator (FDS) as a representative fire model. To end this, Fire Detector Evaluator (FDE) which could be measured the device properties of detector was used, and the spot-type fixed temperature heat detectors of two thermistor types and one bimetal type were considered as research objectors. Activation temperature and Response Time Index (RTI) of detectors required for the fire modeling were measured, and then the RTI was measured for ceiling jet flow and vertical jet flow in consideration of the install location of detectors. The results of fire modeling using measured device properties were compared and validated with the experimental results of full-scale compartment fires. It was confirmed that, in result, the numerically predicted activation time of detector showed reasonable agreement with the measured activation time.
Park, Seul-Hyun;Lee, Joo-Hee;Kim, Youn-Kyu;Hwang, Cheol-Hong
Proceedings of the Korea Institute of Fire Science and Engineering Conference
/
2011.11a
/
pp.7-10
/
2011
최근 국제우주정거장에서 화재안전에 관한 중요성의 인식으로 화재의 감지/소화의 메커니즘을 구체적으로 이해하기 위한 다양한 연구들이 시도되고 있다. 본 연구에서는 국제우주정거장에서 각종 실험과 연구를 진행하는 가압모듈을 대상으로 환기, 연기거동 및 감지에 관한 수치모델링을 수행하였다. 수치모델링은 NIST에서 개발된 FDS (Fire Dynamic Simulator)가 사용되었다. 국제우주정거장 내부는 마이크로중력환경으로 부력이 존재하지 않아 화재 발생 시 화염 및 연기거동은 지상에서의 현상들과 큰 차이를 보이게 된다. 따라서 현재 가압모듈에서 적용되고 있는 환기조건의 변화에 따른 연기거동 및 감지특성에 대한 연구는 향후 국내의 국제 우주정거장 실험 참여를 위한 기초적인 정보를 제공할 것으로 기대된다.
Proceedings of the Korea Institute of Fire Science and Engineering Conference
/
2010.10a
/
pp.241-245
/
2010
화재방호에 성능기반 개념을 도입함에 따라 화재모델링의 활용도는 점점 높아지고 있다. 본 연구의 목적은 FDS를 이용하여 원자력발전소 펌프실의 윤활유 화재 시 케이블의 손상여부를 평가하고, 확인분석을 통해 화재모델링의 적합성을 파악하는 데 있다. 화재는 펌프 주변의 누출된 윤활유에서 발생하며 화원의 면적은 $2.75m^2$이고 단위면적당 열방출율은 $1,794kW/m^2$로 가정하였다. 계산결과, 고온기체층의 온도는 $400^{\circ}C$를 상회하고 있으나 케이블 트레이의 온도는 $50^{\circ}C$ 아래로 예측되고 있어 본 화재시나리오에서 케이블의 건전성은 유지되고 있으며 밀폐된 격실에서의 대형화재는 환기지배형 화재가 된다는 것을 보여주고 있다. 또한 확인분석 결과, 화재 시나리오의 주요 변수인 열방출율, 격실크기 그리고 강제 환기 변수가 확인계산 범위 내에 있어 본 계산결과는 NUREG-1824의 확인요건을 만족하고 있다. 따라서 펌프실 윤활유 화재에 대한 모델링의 적합성을 확인하였다.
Journal of the Computational Structural Engineering Institute of Korea
/
v.29
no.4
/
pp.369-376
/
2016
In this study, a numerical analysis framework for investigating the nonlinear behavior of structures under fire conditions is presented. In particular, analysis procedure combining fire-driven flow simulation and thermo-mechanical analysis is discussed to investigate the mechanical behavior of fire-exposed representative volume structures made of steel and concrete, respectively. First of all, fire-driven flow analysis is conducted using Fire Dynamics Simulator(FDS) in a rectangular parallelepiped domain containing the structure. The FDS simulation yields the time history of temperature on the surface of the structure under fire conditions. Second, mechanical responses of the fire-exposed structure with respect to prescribed uniformly distributed loads are calculated by a coupled thermo-mechanical analysis using the time-varying surface temperature as boundary conditions. Material nonlinearities of steel and concrete have been considered in the thermo-mechanical analysis. A series of numerical results are presented to demonstrate the feasibility of the multiphysics structural fire analysis for investigating the structural behavior under fire conditions.
Kim, Jong-Hoon;Park, Won-Hee;Kim, Woon-Hyung;Myoung, Sang-Yup
Journal of the Society of Disaster Information
/
v.17
no.1
/
pp.120-127
/
2021
Purpose: In this study, the effect of changes in the variables related to water droplets on the spray density on the floor in the analysis of the water mist fire protection system using FDS was analyzed. Method: When the spray of the water mist nozzle was analyzed in FDS, Particles Per Seconds, Particle Velocity, Size Distribution, and Spray Pattern Shape that can be set in relation to droplets were input to review the analyzed results. Result: In the analysis results, when the number of particles per second was set above a certain value, the spray density of the floor was similar. In the case of Particle Velocity, as the velocity decreases, the spray density of the central portion increases but decreases at a distance of 0.15m or more. From the analysis of the change in the size distribution function, it was found that an increase in the 𝛾 value increases the spray density of the central part, but the value at a remote location decreases. Compared to the result of applying the Gaussian distribution, the median value decreases dramatically when the uniform distribution is applied, but the value at the adjacent position increases. Conclusion: Variables related to the droplet properties of the FDS affect the spray density of the floor. Therefore, in order to increase the reliability of results before performing analyses such as fire suppression or cooling, a sufficient review of input variables is required.
터널화재의 위험요소에 대한 해석을 위해서는 실제 상황을 재현한 실대형 실험이 가장 유용하겠지만 현실적으로 시간적, 공간적, 경제적인 제약이 따르기 때문에 CFD Modeling 기술의 이용 및 검증이 필요하고, 실제 상황에 가까운 현상의 재현을 위해서는 시뮬레이션의 정확도에 대한 향상이 필수적이다. 또한, CFD Modeling을 터널화재에 적용할 때 시뮬레이션의 질에 영향을 미칠 수 있는 요소들에 대한 결정이 선행되어야 한다. 우선, 터널의 기하학적 구조와 경계조건의 확립이 필요한데 필요한 정보를 얻기 위해서 어느정도 길이의 터널이 적절한지에 대해 생각할 필요가 있으며, 단면변화에 대한 결정을 통해 모델링을 수행하여야 한다. 모델링 작업이 선행된 후에 화재의 위치, 성장률, 최대 크기, 환기시스템 사항 등의 고려가 필요한데 이러한 조건들은 CFD Modeling의 결과에 직접적인 영향을 주기 때문에 충분한 사전조사가 이루어져야 하고, 각 사항들의 변수를 고려하여 다양한 화재시나리오의 도출이 가능할 수 있다. 마지막으로, 화재에서 발생된 열중 약 30%가 복사에 의해 주위 벽으로 전달될 수 있고 열은 연기가 가득찬 영역내에서 재분배될 수 있는데, 열전달 및 연기의 유동 등에 관한 자료를 기초로 화재현상에 대한 분석이 가능하다. 이러한 과정들을 통해 실제 상황에 가까운 설계화재 시나리오를 예측할 수 있다. 본 연구에서는 우리나라 최장대터널인 죽령터널에 대해 합리적인 가정을 통한 설계화재 시나리오를 기초로 화재시뮬레이션은 FDS(Fire Dynamics Simulator) 프로그램을 사용하여 화재 및 연기의 이동 양상을 분석하고, 피난시뮬레이션은 SIMULEX 프로그램을 사용하여 피난시간을 예측 함으로써 터널화재의 CFD Modeling에 의한 피난안전성을 검토하고자 한다.
A performance-based design of smoke management systems for semiconductor fabrication facilities is described in this paper. The example of one such facility is discussed. Performance criteria for smoke control systems were established, effective smoke removal system features were identified and optimal system exhaust capacity requirements were developed by applying engineering tools including Fire Dynamic Simulator model. Considering the fact that the absence of relevant design guide, codes for consensus standards for semiconductor smoke design in Korea and United States this performance based approach can and should be applied to other fabrication facilities designs.
Proceedings of the Korea Institute of Fire Science and Engineering Conference
/
2010.10a
/
pp.216-223
/
2010
원자력발전소의 방화지역에서 화재가 발생할 경우 케이블의 화재리스크는 온도, 열속, 화염 등 열적 특성에 의해 평가된다. 원전의 안전정지 기능에 사용되는 각종 케이블은 설계관리 및 성능분석을 위해 화재실증실험으로 열적 특성을 실측하여야 하지만 다양한 화재시나리오에 대한 실험 조건 확보와 실험 비용 등 제약이 따른다. 이에 따라 화재모델 FDS (Fire Dynamics Simulator)의 최신버전에 포함된 THIEF (Thermally-Induced Electrical Failure) 모델을 이용하여 국내 원전의 안전정지 케이블에 대한 화재모델링 분석을 수행하였다. 이 연구에서는 케이블이 설치된 형태에 따라 일정 열속에 대한 자켓 온도와 경계조건에 대한 온도분포를 분석하였다. 본 연구 결과 THIEF 모델은 원전 방화지역의 화재에서 안전정지 케이블의 내부온도를 예측할 수 있는 화재모델로 사용가능한 것으로 확인되었다.
The quantitative risk assessment methods for thermal failure in targets were studied using fire modeling. To this end, Fire Dynamics Simulator (FDS), as a representative fire model, was used and the probabilities related to thermal damage to an electrical cable were evaluated according to the change in fire area inside a specific compartment. 'The maximum probability of exceeding the damage thresholds' adopted in a conservative point of view and 'the probability of failure' including the time to damage were compared. The probability of failure suggested in the present study could evaluate the quantitative fire risk more realistically, compared to the maximum probability of exceeding the damage thresholds with the assumption that thermal damage occurred the instant the target reached its minimum failure criteria in terms of the surface temperature and heat flux.
This paper investigated the fire and smoke behavior in the compounded multiplex theater using FDS with various spacial and boundary conditions to ensure the fire safety of the multiplex. The results showed that more rapid temperature increase and smoke can be induced near the exit door for the lower fire load duo to the horizontal smoke movement. The overuse of fire resistants can generate more smoke while delaying combustion rate, which can give adverse effect to the evacuation. The mal-function of the exhaust fan would obstruct smoke exhaust but also retard the function of sprinkler head.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.