• Title/Summary/Keyword: FAN

Search Result 3,629, Processing Time 0.038 seconds

Development of a High-efficiency and Low-noise Axial Flow Fan through Combining FanDAS and CFX codes (FanDAS-CFX 결합을 통한 고효율-저소음 축류 송풍기의 개발)

  • Lee, Chan;Kil, Hyun Gwon;Noh, Myung-Keun
    • The KSFM Journal of Fluid Machinery
    • /
    • v.15 no.5
    • /
    • pp.37-41
    • /
    • 2012
  • High-efficiency and low-noise axial flow fan is developed by combining the FanDAS, a computerized axial fan design/performance analysis system, and CFD software(CFX). Based on fan design requirements, FanDAS conducts 3-D blade geometry design, quasi-3D flow/ performance analyses and noise evaluation by using through-flow analysis method and noise models for discrete frequency and broadband noise sources. Through the parametric studies of fan design variables using FandDAS, preliminary and baseline design is achieved for high efficiency and low noise fan, and then can be coupled with a CFD technique such as the CFX code for constructing final and optimized fan design. The FanDAS-CFX coupled system and its design procedure are applied to actual fan development practice. The FanDAS provides an optimized 3-D fan blade geometry, and its predictions on the performance and the noise level of designed fan are well agreed with actual test results.

Integrated Process for Development of an Optimal Axial Flow Fan (Design, RP, Measurement, Injection Molding, Assembly) (최적 축류팬 개발을 위한 통합공정 (설계, 시제품제작, 측정, 금형가공, 사출, 조립))

  • 박성관;최동규
    • Korean Journal of Computational Design and Engineering
    • /
    • v.3 no.3
    • /
    • pp.201-209
    • /
    • 1998
  • To develop timely an optimal fan, a design system and a new manufacturing process used step by step have to be integrated. A small sized optimal fan for refrigerators, that was the goal on this project, was developed by the following principal processes. All processes are technologically linked in many directions: The existing fan was measured through reverse engineering. The measured data was used for the basic source of 3D design. The performance tests were carried and used as the data for the evaluation of the existing fan. Flow analysis by FANS-3D/sup [1]/ was performed at the given information (pressure drop and flow rate) to find out the configuration of optimal fan design. The flow patterns were investigated to measure the performance of fan through numerical experiment. The grid point data obtained by the above analysis turned into 3D high efficiency fan model by using CATIA. The product was manufactured by RP process (SLS, SLA) and tested the characteristic curves of the developed fan to compare with the existing fan. The modification of fan design were all examined to see any change in performance and checked to find any deficiency in assembling the fan into a duct. After the plastics flow analysis of the injection molding cycle to ensure acceptable quality fan, an optimal mold was processed by using tool-path for the newly designed fan.

  • PDF

Experimental and Numerical Studies on the Flow Characteristics of a Fan-Sink (팬싱크의 유동 특성에 관한 실험 및 수치해석적 연구)

  • Lee Kyoung-Yong;Choi Young-Seok;Yun Jae-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.3
    • /
    • pp.225-230
    • /
    • 2006
  • The overall performance and local flow fields of the fan, heat sink, and fan-sink were experimentally and numerically studied to investigate the flow characteristics of a fan-sink. The flow resistance of the heat sink was measured by small fan tester based on AMCA standards and compared with the CFD results to select available cooling fan for the fan-sink. The nonuniform velocity profile behind the fan outlet was shown by the flow visualization. The effects of nonuniform velocities on the performance of heat sink were discussed. To validate the commercial CFD code CFX-5.6, the predicted performance curve was compared with that of fan testing. The local flow fields of the fan-sink were analyzed by CFD results. MFR (multiple frame of reference) was used as a computational model combining rotating fan and stationary heat sink. Through the CFD results of the fan-sink, the flow patterns behind the fan outlet influenced the flow resistance and overall performance of the heat sink.

A Study of Design Method of an Axial-Type Suction Fan (축류형 흡입송풍기 설계기술에 관한 연구)

  • Choi, Hyoung-Jun;Kim, Chang-Su;Cho, Chong-Hyun;Cho, Soo-Yong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.13 no.1
    • /
    • pp.42-51
    • /
    • 2010
  • Many different types of fan have been applying to various industrial fields. Fan design methods are much different depending on the types of fan, operating conditions, and connecting parts at the inlet or exit of the fan etc. In this study, design methods for an axial-type suction fan are studied. This fan discharges the air in the relative static pressure of -285Pa to the atmosphere with the flow rate of $960m^3/min$. For three-dimensional blade design, three different design methods were applied, such as the free vortex method, the exponential method, and the cascade method. In the cascade method, the blade loading along the radial direction was obtained from the lift coefficient which was necessary to obtain the pressure rise on a fan rotor. This method is different from the free vortex and the exponential method which control the strength of the vortex. The fan performance prediction was conducted using the CFD with three different inlet ducts. The best fan performance was obtained when the fan was designed by using the cascade method. The designed fan using the exponential method showed better performance compared to a fan designed using the free vortex method. However, the fan performance was changed depending on the installed inlet ducts. So, an efficient fan can be designed with the adjustment of design variables on the basis of the flow structures within the fan as well as the fan design procedure.

Development of Low-Noise Cooling Fan Using Uneven Fan Blade Spacing (비등간격 블레이드를 이용한 저소음 쿨링팬 개발)

  • Lee, Jeong-Han;Nam, Kyung-Ook
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1109-1114
    • /
    • 2007
  • When unifying the functions of widely used two-fan, engine cooling system into a single unit, the noise and power issues must be addressed. The noise problem due to the increased fan radius is a serious matter especially as the cabin noise becomes quieter for sedans. Of the fan noise components, discrete noise at BPF's (Blade Passing Frequency) seriously degrades cabin sound quality. Unevenly spaced fan is developed to reduce the tones. The fan blades are spaced such that the center of mass is placed exactly on the fan axis to minimize fan vibration. The resulting fan noise is $3{\sim}11$ dBA quieter in discrete noise level than the even bladed fan.

  • PDF

Computational Fluid Dynamic Analysis for Improving the Efficiency of Desulfurization System for the Wet Flue Gas (습식 배연탈황 시스템의 효율 향상을 위한 전산해석)

  • Hwang, Woo-Hyeon;Lee, Kyung-Ok
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.2
    • /
    • pp.161-171
    • /
    • 2014
  • In this paper the flow dynamics of the flue gas equipment in the desulfurization system was numerically analyzed by simulating the problems for the turbulent and combustion flow from Induced Draft Fan(I.D.Fan) outlet to Booster Up Fan(B.U.Fan) inlet using the commercial CFD software of CFD-ACE+ in CFDRC company for Computational Fluid Dynamic Analysis. The guide vane of this section was examined for the minimum pressure loss and the uniform flow dynamic to B.U.Fan with the proper velocity from I.D,Fan exit to B,U,Fan inlet section at the boiler both the maximum continuous rating and the design base. The guide vanes at I,D.Fan outlet and B.U.Fan inlet were removed and modified by numerical simulation of the CFD analysis. The flue gas at the system had the less pressure loss and the uniform flow dynamics of the flow velocity and flow line by comparing with the old design equipment.

A Study on the FanQie(反切) Mark of HuangdineijingTaisu (『황제내경태소(黃帝內經太素)』 반절(反切) 표기에 대한 고찰)

  • Ahn, Jin-hee
    • Journal of Korean Medical classics
    • /
    • v.32 no.1
    • /
    • pp.29-48
    • /
    • 2019
  • Objectives : The purpose of this study is to investigate which system the FanQie notation of "Taisu(太素)" followed by comparing FanQie notation appearing in "Taisu", with the Sound button(聲紐) and Rhyme system(韻類) of the FanQie notation appearing in the "Qieyun(切韻)" system phonology book and "Guangyun(廣韻)". Methods : Followed by organizing the FanQie list in "Taisu", in comparing this list with the top and bottom characters of FanQie in the "Qieyun" system phonology book and "Guangyun", this study explores the similarity of the system after noting the Sound button and the Rhyme system. Results & Conclusions : 1. Compared to FanQie of "Taisu" with that of "Qieyun" system, the Sound button and Rhyme system were 61.54% identical, and when comparing FanQie of "Taisu" with that of "Guangyun", the Sound button and Rhyme system were 55.45% identical. 2. Comparing FanQie top and bottom letters themselves of the "Taisu" and "Qieyun" system, of the 217 FanQie sound notation Chinese characters, FanQie top and bottom letters of 18 characters were the same, accounting for 8.29%, and when compared to the "Taisu" with the FanQie top and bottom characters of "Guangyun", 15 FanQie top and bottom characters were the same, accounting for 6.91%. 3. Of the total 11,500 characters in "Qieyun", the ratio of FanQie notation Chinese characters in "Taisu" was 1.89%, and among them, nine characters came out in "Taisu" FanQie notation while there was none in "Qieyun". This accounted for 4.15% of 217 FanQie notation sound Chinese characters in "Taisu", demonstrating that this represented a relatively high ratio. 4. Conclusionally "Taisu" was more closely related to "Qieyun" system phonology book than "Guangyun" in FanQie notation, and there is also a possibility that Yang Shangshan has created some FanQie notation by himself or additionally referred to other phonology books that are not "Qieyun" system phonology book.

A Study on the Viewing Experience and Performance of Professional Baseball Team: The Team Performance Side and the Fan Performance Side

  • Byun, Kyung-Won
    • International journal of advanced smart convergence
    • /
    • v.10 no.1
    • /
    • pp.166-175
    • /
    • 2021
  • The purpose of this study is to analyze the structural relationship among fan experience, fan satisfaction, team attachment, psychological well-being, team loyalty and quality of life. Specifically, the structural equation model is analyzed for the team performance side leading to fan experience-fan satisfaction-team attachment-team loyalty and the an performance side leading to fan experience-fan satisfaction-psychological well-being-quality of life. The survey to achieve the goal of this study is a professional baseball fan. 150 pilot envestigation and 348 main envestigation were selected as the final effective samples. Data processing was done with SPSS 23 for frequency analysis, exploratory factor analysis and reliability analysis. Also, AMOS 21 was used for confirmatory factor analysis and structural equation model analysis. The results of the analysis are as follows: First, fan experience had a positive effect on the fan satisfaction. Second, fan satisfaction had a positive effect on the team attachment. Third, fan satisfaction had a positive effect on the psychological well-being. Fourth, team attachment had a positive effect on theteam loyalty. Fifth, psychological well-being had a positive effect on the quality of life.

System optimization of the low noise Wave Fan (저소음 Wave Fan 의 System 최적화)

  • Cho, Kyung-Seok;Kim, Woo-June;Joo, Won-Seok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1100-1103
    • /
    • 2007
  • For the past decade many effort has been delivered to understand noise generation mechanism for the small size engine cooling fan. As a result of that effort, the low noise fan such as the Wave fan was developed. Now the Wave fan becomes the well known low noise engine cooling fan. But in case of the new car development, the system in the new car will be different from previous one. So we need system optimization for every new model. In case of special application, a low speed fan should be developed to match system requirement. In that case, we meet severe engineering requirement by conducting fan system optimization instead of the simple fan scaling. In this paper, I will show you the system optimize process.

  • PDF

A study on Low-Noise and High-Efficiency Sirocco Fan Development (저소음 고효율 시로코 홴 개발에 관한 연구)

  • Park, Kwang-Jin;Lee, Sang-Hwan;Son, Byung-Jin
    • The KSFM Journal of Fluid Machinery
    • /
    • v.2 no.2 s.3
    • /
    • pp.46-56
    • /
    • 1999
  • This study is on the performance prediction and design of a sirocco fan. Slip coefficient is very important factor for the performance analysis of a centrifugal-type fan. Because generally used slip coefficient equations of backward curved centrifugal fan are not appropriate for forward curved sirocco fan, in this study a proper slip coefficient equation for a sirocco fan is suggested. Using this equation performance prediction program for sirocco fan is composed of and also included the total noise prediction that include the turbulent noise at the fan inlet and boundary layer noise. A comparison between the values obtained from performance prediction program and experimental values shows that the program predicts the sirocco fan performance in a practical rate.

  • PDF