• Title/Summary/Keyword: F8T2

Search Result 1,430, Processing Time 0.031 seconds

The $^4A_2(^4F)\rightarrow^4T_1(^4F)$ Transitions of a $Co^{2+}$ Ion in Inse Single Crystals (Inse 달결정에서 $Co^{2+}$ 이온의 $^4A_2(^4F)\rightarrow^4T_1(^4F)$ 전이특성)

  • 박병서
    • Journal of the Korean Vacuum Society
    • /
    • v.4 no.2
    • /
    • pp.119-123
    • /
    • 1995
  • Bridgman 방법으로 성장한 InSe: Co 단결정의 근적외 영역에서의 광흡수 특성을 상온에서 조사하였다. 1350, 1530, 1710nm 파장영역에서 Td 대칭을 갖는 Co2+ 이온의 4A2(4F)$\longrightarrow$4T1(4F)전이에 대응되는 3개의 흡수 peak를 관측하였다. 이 미세구조는 스핀-궤도 결합효과에 의하여 분리된 Co2+ 이온의 4T1(4F) 준위의 $\Gamma$6, $\Gamma$8, $\Gamma$7+$\Gamma$8 준위와 바닥상태 4A2(4F)의 $\Gamma$8 준위 사이의 전자전이에 기인하며, 결정장이론에 의하여 잘 설명되었다.

  • PDF

Investigation of Co- and Pr-doped yttria-stabilized cubic zirconia (YSZ) single crystal grown by skull melting method (스컬용융법에 의해 성장시킨 Co와 Pr이 첨가된 이트리아안정화큐빅지르코니아(YSZ) 단결정의 연구)

  • Moon, So-I;Seok, Jeong-Won
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.24 no.4
    • /
    • pp.140-144
    • /
    • 2014
  • Co-(0.7 wt%) and Pr-(2.0, 3.5 or 5.0 wt%) doped cubic zirconia ($ZrO_2:Y_2O_3=50:50wt%$) single crystals grown by a skull melting method were heat-treated in $N_2$ at $1150^{\circ}C$ for 5 hrs. The brown colored as-grown single crystals were changed into either dark brownish green, greenish blue and light green color after the heat treatment. Before and after the heat treatment, the YSZ (yttria-stabilized zirconia) single crystals were cut for wafer form (${\phi}7.5mm{\times}t3mm$). The optical and structural properties were examined by UV-VIS spectrophotometer and X-ray diffraction. Absorption by $Co^{2+}$(${\fallingdotseq}589nm$: ${\Gamma}_8[^4A_2(^4F)]{\rightarrow}{\Gamma}_8+{\Gamma}_7[^4T_1(^4F)]$, ${\fallingdotseq}610nm$: ${\Gamma}_8[^4A_2(^4F)]{\rightarrow}{\Gamma}_8[^4T_1(^4F)]$], ${\fallingdotseq}661nm$: ${\Gamma}_8[^4A_2(^4F)]{\rightarrow}{\Gamma}_6[^4T_1(^4F)]$]) and $Pr^{3+}$(${\fallingdotseq}450nm$: ${^3}H{_4}-{^3}P{_2}$, ${\fallingdotseq}473nm$: ${^3}H{_4}{\rightarrow}{^3}P{_1}$, ${\fallingdotseq}484nm$: ${^3}H{_4}{\rightarrow}{^3}P{_0}$), change of ionization energy and lattice parameter were confirmed.

Experimental Study on Tensile Fatigue Strength of the High Strength Bolts (고장력볼트의 인장피로강도에 관한 실험적 연구)

  • Han, Jong Wook;Park, Young Suk
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.2A
    • /
    • pp.165-170
    • /
    • 2008
  • New high strength bolts are required due to the development of the high strength steel, the ultra-thick steel plates, and the long-span bridge, though high strength bolts with tensile strength of 1,000 MPa are mainly used in construction site of every country. The high strength bolts are often subjected to a repeated tension-type of loading in which the fatigue failure is a major mode of failure. However, the theoretical and experimental study for the fatigue failure of tension bolt has not been well established in Korea. In this study, we performed a tensile fatigue test of F8T, F10T and F13T, F13T-N high strength bolts under tension. We proposed three fatigue strength specifications by performing 95% survival probability analysis for F8T, F10T, F13T, and F13T-N bolt under the $2{\times}10^6$ cycles of repeated loading. And the fatigue strength for the advanced screw thread shape bolt developed in this study are compared with the previous KS screw thread shape bolt.

ON THE CATCH OF GILL NET IN THE JEJU ISLAND -Comparison of mackerel catch in monofilament and multifilament gill nets- (제주도 자망이망율에 관하여 -고등어 자망의 이망율 비교-)

  • SHON Tae Jun
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.8 no.1
    • /
    • pp.7-10
    • /
    • 1975
  • The catches of mackerel by monofilament and multifilament net were compared by means of $x^2$ and t-test method. In order to improve the netting twine of drift nets, 6 shoots 5 different mesh and nylon-monofilament netting twines $(B\times2,\;C\;D,\;F,)$ and 2 shoe nylon-multifilament $(A\times2)$ which are using near the Jeju Island in contemporary days were used for the experiment. These gill no were connected in order of A, ,B, C, A, B, E, F and operated fly fishing boat Taeann Ho (7T) near sea of Jeju Ialand from May 1974 to August 1974. The results obtained are as follows: 1. B type nylon-monofilament gill nets were superior to nylon-multifilament gill nets in catch according to the result of $X^2$ test and t-test, and the catch ratio was $M_A:\;M_B=1:1.8$. 2. 75mm mesh size C, D nylon-monofilament gill nets were superior to 85mm mesh size nylonmonofilament gill nets, and their catch ratio were E, F: C, D=1:2.8. 3. The catch ratio C, D and E, F type nets were compared by means of t-teat, however could not recognized their relationship.

  • PDF

An Acoustic Study of Relative Articulatory Positions of English Vowels and Korean Vowels

  • Ahn, Soo-Woong
    • Speech Sciences
    • /
    • v.8 no.4
    • /
    • pp.171-184
    • /
    • 2001
  • American English vowels and Korean vowels were compared by the plotformant method. For American English vowels, six General American English speakers pronounced English words in the b_t environment. For Korean vowels eight Kyongsang dialect speakers and eight Seoul dialect speakers pronounced Korean words in the environments of k_t, p_t and t_t. The formant plots were obtained by plotting F1/F2 tokens of 13 American English vowels on the F1xF2 plane. In spite of personal variations the 13 vowel spaces of all six American English speakers maintained their relative positions with some overlaps. Clear distinctions were made between i-I, e-$\varepsilon$, u-$\sigma$, and o-c. The domain of c and $\alpha$ overlapped for three American English speakers, but it did not for three other speakers. The 8 Korean vowel spaces of Kyongsang dialect speakers and Seoul dialect speakers were very similar and maintained their relative positions. No distinction was made between e and $\varepsilon$. In contrast with American English e which is a neutral vowel, Korean e was a back vowel. The comparison of 13 American English vowel positions and 8 Korean Vowel positions is expected to shed some light on the errors of English vowel pronunciation of Korean learners.

  • PDF

A Study on analysis of contrasts and variation in SUV with the passage of uptake time in 18F-FDOPA Brain PET/CT (18F-FDOPA Brain PET/CT 검사의 영상 대조도 분석 및 섭취 시간에 따른 SUV변화 고찰)

  • Seo, Kang rok;Lee, Jeong eun;Ko, Hyun soo;Ryu, Jae kwang;Nam, Ki pyo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.1
    • /
    • pp.69-74
    • /
    • 2019
  • Purpose $^{18}F$-FDOPA using amino acid is particularly attractive for imaging of brain tumors because of the high uptake in tumor tissue and the low uptake in normal brain tissue. But, on the other hand, $^{18}F$-FDG is highly uptake in both tumor tissue and normal brain tissue. The purpose of study is to evaluate comparison of contrasts in $^{18}F$-FDOPA Brain PET/CT and $^{18}F$-FDG Brain PET/CT and to find out optimal scan time by analysis of variation in SUV with the passage of uptake time. Materials and Methods A region of interest of approximately $350mm^2$ at the center of the tumor and cerebellum in 12 patients ($51.4{\pm}12.8yrs$) who $^{18}F$-FDG Brain PET/CT and $^{18}F$-FDOPA Brain PET/CT were examined more than once each. The $SUV_{max}$ was measured, and the $SUV_{max}$ ratio (T/C ratio) of the tumor cerebellum was calculated. In the analysis of SUV, T/C ratio was calculated for each frame after dividing into 15 frames of 2 minutes each using List mode data in 25 patients ($49.{\pm}10.3yrs$). SPSS 21 was used to compare T/C ratio of $^{18}F$-FDOPA and T/C ratio of $^{18}F$-FDG. Results The T/C ratio of $^{18}F$-FDOPA Brain PET/CT was higher than the T/C ratio of $^{18}F$-FDG Brain, and show a significant difference according to a paired t-test(t=-5.214, p=0.000). As a result of analyzing changes in $SUV_{max}$ and T/C ratio, the peak point of $SUV_{max}$ was $5.6{\pm}2.9$ and appeared in the fourth frame (6 to 8 minutes), and the peak of T/C ratio also appeared in the fourth frame (6 to 8 minutes). Taking this into consideration and comparing the existing 10 to 30 minutes image and 6 to 26 minutes image, the $SUV_{max}$ and T/C ratio increased by 0.2 and 0.1 each, compared to the 10 to 30 minutes image for 6 to 26 minutes image. Conclusion From this study, $^{18}F$-FDOPA Brain PET/CT is effective when reading the image, because the T/C ratio of $^{18}F$-FDOPA Brain PET/CT was higher than T/C ratio of $^{18}F$-FDG Brain PET/CT. In addition, in the case of $^{18}F$-FDOPA Brain PET/CT, there was no difference between the existing 10 to 30 minutes image and 6 to 26 minutes image. Through continuous research, we can find possibility of shortening examination time in $^{18}F$-FDOPA Brain PET/CT. Also, we can help physician to accurate reading using additional scan data.

Effect of Various Feeding Regimen on the Performance of Korean Native Chicken Consuming Broiler Diets (재래닭의 대한 육계사료 급여체계 설정)

  • 나재천;김학규;정행기;강보석;김웅배
    • Korean Journal of Poultry Science
    • /
    • v.25 no.2
    • /
    • pp.65-70
    • /
    • 1998
  • A 16-wk feeding trial was conducted to investigate the proper feeding regimen on the performance of Korean Native Chicken(KNC) consuming broiler diets. Commercial KNC are normally fed 3 kinds of diets during their life span, i. e., starter(S, 0 to 3wk of age), grower(G, 4 to 7wk of age), and finisher(F, 8 to l6wk of age) diets. In this trial, four feeding regimen were employed:T1(S-G-F), T2(S-G-G), T3(S-S-F), and T4(S-F-F). Day-old 360 KNC were randomly allotted to 12 pens: three pens per treatment, and 30 birds per pen. At the end of the trial, the BW of T2 was significantly better than that of T3(P<0.05), and T1 and T4 were intermediate. No significant difference were found in feed intake, feed conversion ratio, and viability among treatments. It appears that, in terms of BW gain, the T2 is the recommendable feeding regimen for KNC consuming broiler diets.

  • PDF

Effect of Output-conductance on Current-gain Cut-off frequency in In0.8Ga0.2As High-Electron-mobility Transistors (In0.8Ga0.2As HEMT 소자에서 Output-conductance가 차단 주파수에 미치는 영향에 대한 연구)

  • Rho, Tae-Beom;Kim, Dae-Hyun
    • Journal of Sensor Science and Technology
    • /
    • v.29 no.5
    • /
    • pp.324-327
    • /
    • 2020
  • The impact of output conductance (go) on the short-circuit current-gain cut-off frequency (fT) in In0.8Ga0.2As high-electron-mobility transistors (HEMTs) on an InP substrate was investigated. An attempted was made to extract the values of fT in a simplified small-signal model (SSM) of the HEMTs, derive an analytical formula for fT in terms of the extrinsic model parameters of the simplified SSM, which are related to the intrinsic model parameters of a general SSM, and verify its validity for devices with Lg from 260 to 25 nm. In long-channel devices, the effect of the intrinsic output conductance (goi) on fT was negligible. This was because, from the simplified SSM perspective, three model parameters, such as gm_ext, Cgs_ext and Cgd_ext, were weakly dependent on goi. However, in short-channel devices, goi was found to play a significant role in degrading fT as Lg was scaled down. The increase in goi in short-channel devices caused a considerable reduction in gm_ext and an overall increase in the total extrinsic gate capacitance, yielding a decrease in fT with goi. Finally, the results were used to infer how fT is influenced by goi in HEMTs, emphasizing that improving electrostatic integrity is also critical importance to benefit fully from scaling down Lg.

The Effect of Electroacupuncture at the ST36 on the Electroencephalogram (족삼리(ST36) 전침 자극이 뇌파에 미치는 영향)

  • Gwon, Sun-Cheol;Youn, Dae-Sik;Lee, Sang-Ryong
    • Korean Journal of Acupuncture
    • /
    • v.23 no.1
    • /
    • pp.15-36
    • /
    • 2006
  • Objectives . The aim of this study was to examine the effect of electroacupuncture(EA) at the ST36 on normal humans by using power spectral analysis. Methods : EEG(Electroencephalogram) power spectral exhibits site-specific and state-related differences in specific frequency bands. In this study, power spectrum was used as a measure of complexity. 32 channel EEG study was carried out in 12 subjects (10 males; age=26.7 years old, 2females; age=28 years old). Results ; In ${\alpha}$ (alpha) band, the power values at Fp2, F7, F3, Fz, FTC1, FTC2, T3, C3, Cz, C4, TT1, TCP1, CP1, CP2,T5, P3, Pz, P4, Po1, Po2, O1, Oz,O2 channels(p<0.05) during the ST36-acupoint treatment were significantly increased. In ${\beta}$ (beta) band, the power values at Fp2, F7, F3, Fz, F4, F8, FTC1, FTC2, T3, C3, Cz, C4, TT1, TCP1, CP1, CP2, T5, P3, Pz, P4, Po1, Po2, O1, Oz, O2 channels(p<0.05) during the ST36-acupoint treatment were significantly decreased. In ${\delta}$ (delta) band, the power values at F7, Fz, T3, C3, TT1, TCP1, CP1, CP2, T5, P3, Pz,T6, Po1, PO2,O1, Oz, O2 channels(p<0.05) during the ST36-acupoint treatment were significantly decreased. In ${\theta}$(theta) band, the power values at F7, Fz, FTC1, T3, TCP1, CP2, TCP2, Po1, Po2 channels(p<0.05) during the ST36-acupoint treatment were significantly decreased. ${\alpha}$/${\beta}$ values at Cz, T5, O1, Oz, O2 channels during the ST36-acupoint treatment were increased. ${\beta}$/${\theta}$ values at Fpl, F7, F3, Fz, F4, F8, FTC1, FTC2, T3, C3, C4, T4, TT1, TCP1, TCP2, TT2, P3, P4, T6, Pol channels during the ST36-acupoint treatment were increased. Conclusions : This results suggest that Electroacupuncture at the ST36 mostly affects the charge on alpha(23 channels), beta(25 channels) bands.

  • PDF

Magnetic Properties of $ThMn_{12}-type$$NdFe_{10.7}Ti_{1.2}Mo_{0.1}$>$Ti_{1.2}Mo_{0.1}$ ($ThMn_{12}$$NdFe_{10.7}Ti_{1.2}Mo_{0.1}$의 미세구조 및 자기적 성질 연구)

  • 안성용;이승화;김철성;김윤배;김창석
    • Journal of the Korean Magnetics Society
    • /
    • v.7 no.2
    • /
    • pp.90-96
    • /
    • 1997
  • We have studied crystallographic and magnetic properties of $NdFe_{10.7}Ti_ {1.2}Mo_{0.1}$ by Mossbauer spectroscopy, X-ray diffraction and vibrating sample magnetometer (VSM). The alloys were prepared by arc-melting under an argon atmosphere. The $NdFe_{10.7}Ti_{1.2}Mo_{0.1}$ has pure a single phase, whereas $NdFe_{10.7}Ti_{1.3}$ contains some $\alpha$-Fe, conformed with X-ray diffractometry and Mossbauer measurements. The $NdFe_{10.7}Ti_ {1.2}Mo_{0.1}$ has a $ThMn_{12}-type$ tetragonal structure with $a_0=8.637{\AA}$ and $c_0=4.807{\AA}$. The Curie temperature ($T_c$) is 600 K from the result of Mossbauer measurement performed at various temperatures ranging from 13 to 800 K. Each spectrum of below $T_c$ is fitted with five subspectra of Fe sites in the structure ($8i_1, 8i_2, 8j_2, 8j_1, 8f$). The area fractions of the subspectra at room temperature are 12.3%, 14.0%, 21.0% 11.8%, 40.9%, respectively. Magnetic hyperfine fields for the Fe sites decrease in the order, $H_{hf}(8i)>H_{hf}(8j)>H_{hf}(8f)$. The abrupt changes in the magnetic hyperfine field, an magnetic moment observed at about 160 K in $NdFe_ {10.7} Ti_{1.2}Mo_{0.1}$ are attributed to spin reorientations. The average hyperfine field of the $NdFe_{10.7}Ti_{1.2}Mo_{0.1}$ shows a temperature dependence of $[H_{hf}(T)-H_{hf}(0)]/H_{hf}(0)=-0.34(T/T_C)^{3/2}-0.14(T/T_C)^{5/2}$ for $T/T_c<0.7$, indicative of spin wave excitation. The Debye temperatures of $NdFe_{10.7}Ti_{1.2}Mo_{0.1}$ is found to be Θ=340$\pm$5 K.

  • PDF