• Title/Summary/Keyword: F-K 분석

Search Result 3,727, Processing Time 0.048 seconds

Quantitative Evaluation of Regional Cerebral Blood Flow by Visual Stimulation in $^{99m}Tc-HMPAO$ Brain SPECT ($^{99m}Tc-HMPAO$ 뇌 SPECT에서 시각자극에 의한 국소 뇌 혈류변화의 정량적 검증)

  • Juh, Ra-Hyeong;Suh, Tae-Suk;Kwark, Chul-Eun;Choe, Bo-Young;Lee, Hyoung-Koo;Chung, Yong-An;Kim, Sung-Hoon;Chung, Soo-Kyo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.3
    • /
    • pp.166-176
    • /
    • 2002
  • Purpose: The purpose of this study is to investigate the effects of visual activation and quantitative analysis of regional cerebral blood flow. Visual activation was known to increase regional cerebral blood flow in the visual cortex in occipital lobe. We evaluated that change in the distribution of $^{99m}Tc-HMPAO$ (Hexamethyl propylene amine oxime) to reflect in regional cerebral blood flow. Materials and Methods: The six volunteers were injected with 925 MBq (mean ages: 26.75 years, n=6, 3men, 3women) underwent MRI and $^{99m}Tc-HMPAO$ SPECT during a rest state with closed eyes and visual stimulated with 8 Hz LED. We delineate the legion of interest and calculated the mean count per voxel in each of the fifteen slices to quantitative analysis. The ROI to whole brain ratio and regional index was calculated pixel to pixel subtraction visual non-activation image from visual activation image and constructed brain map using a statistical parameter map (SPM99). Results: The mean regional cerebral blood flow was increased due to visual stimulation. The increase rate of the mean regional cerebral blood flow which of the activation region in primary visual cortex of occipital lobe was $32.50{\pm}5.67%$. The significant activation sites using a statistical parameter of brain constructed a rendering image and image fusion with SPECT and MRI. Conclusion: Visual activation was revealed significant increase through quantitative analysis in visual cortex. Activation region was certified in Talairach coordinate and primary visual cortex (Ba17),visual association area (Ba18,19) of Brodmann.

Evaluation of MR Based Respiratory Motion Correction Technique in Liver PET/MRI Study (Liver PET/MRI 검사 시 MR 기반 호흡 움직임 보정 방법의 유용성 평가)

  • Do, Yong Ho;Lee, Hong Jae;Kim, Jin Eui;Noh, Gyeong Woon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.15-22
    • /
    • 2018
  • Purpose Respiratory motion during PET/MRI acquisition may result in image blurring and error in measurement for volume and quantification of lesion. The aim of this study was to evaluate changes of quantitative accuracy, tumor size and image quality by applying MR based respiratory motion correction technique (MBRMCT) using integrated PET/MR scanner. Materials and Methods Data of 30 patients (aged $62.5{\pm}10.2y$) underwent $^{18}F-FDG$ liver PET/MR (Biograph mMR 3.0T, Siemens) study were collected. PET listmode data for 7 minutes was simultaneously acquired with maximum average gate (MAG), minimum time gate (MTG) and non gate (NG) T1 weighted MR images. Gated PET reconstruction was performed using mu-maps generated from MAG and MTG by setting 35% of efficiency window. Maximum SUV ($SUV_{max}$), peak SUV ($SUV_{peak}$), tumor size and full width at half maximum (FWHM) in the z-axis direction of MAG, MTG and NG PET images were evaluated. Results Compared to NG, mean $SUV_{max}$ and $SUV_{peak}$ were increased in MAG 13.15%(p<0.0001), 8.66%(p<0.0001), MTG 13.27%(p<0.0001), 8.80%(p<0.0001) and mean tumor size and FWHM were decreased in MAG 14.47%(p<0.0001), 15.49%(p=0.0004), MTG 14.89%(p<0.0001), 15.79%(p=0.0003) respectively. Mean $SUV_{max}$ and $SUV_{peak}$ of MTG were increased by 0.07%(p=0.8802), 0.13%(p=0.7766). Mean tumor size and FWHM of MTG were decreased by 0.49%(p=0.2786), 0.36%(p=0.2488) compared to MAG. There was no statistically significant difference between MAG and MTG which increase total scan time for about 7 and 2 minutes. Conclusion SUV, accuracy of tumor size and spatial resolution were improved in both of MAG and MTG by applying MBRMCT without installing additional hardware in liver PET/MR study. More accurate information can be provided with the increase of 2 minutes scan time if applying MTG of MBRMCT to various abdominal PET/MR studies affected by respiratory motion.

Changes in Mean Platelet Volume and Platelet Distribution Width after Therapy in Childhood Idiopathic Thrombocytopenic Purpura (소아 특발성 혈소판 감소성 자반증 환아에서 치료경과에 따른 평균 혈소판용적과 혈소판용적 분포폭의 변동)

  • Kim, Jong Tai;Lee, Kyung Won;Kim, Soon Nam;Kim, Moon Kyu
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.4
    • /
    • pp.505-511
    • /
    • 2002
  • Purpose : Mean platelet volume(MPV) and platelet distribution width(PDW) are useful parameters in evaluating disorders of platelets. In cases with idiopathic thrombocytopenic purpura(ITP), they change as platelet count increases. In this study, we compared the values of MPV and PDW in ITP patients at diagnosis with those of normal children. We also studied whether the early changes in MPV may predict the clinical course. Methods : From December 1995 to May 2001, 71 patients with ITP were admitted to Ajou University Hospital. They were treated with IVIg 400 mg/kg for five days and MPV, PDW, platelet count were analysed. Normal control group(n=38) was compared. The study group was divided into acute and chronic forms, and also divided into group A, good early responders whose platelets increased more than $100,000/{\mu}L$ within 5 days and group B who did not. Results : Mean value of MPV at diagnosis in ITP patients was lower than the normal control group(P<0.05). In group A, MPV was abruptly increased on the first day after IVIg and then started to decrease. But in group B, MPV was steadily increased until the fourth day after IVIg. In the normal control group, there were inverse correlations between platelet count and MPV(r=-0.415, P<0.05), but in ITP patients, there were positive relationships between platelet count and MPV(r=0.646, P<0.05) at diagnosis. Conclusions : MPV at diagnosis of ITP was lower than the normal control. MPV and PDW could not predict the course of ITP patients, but MPV could distinguish good early responders. More research is needed to find out the reasons of decreased MPV at diagnosis of ITP.

Influence of Column Aspect Ratio on the Hysteretic Behavior of Slab-Column Connection (슬래브-기둥 접합부의 이력거동에 대한 기둥 형상비의 영향)

  • Choi, Myung-Shin;Cho, In-Jung;Ahn, Jong-Mun;Shin, Sung-Woo
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.4
    • /
    • pp.515-525
    • /
    • 2007
  • In this investigation, results of laboratory tests on four reinforced concrete flat plate interior connections with elongated rectangular column support which has been used widely in tall residential buildings are presented. The purpose of this study is to evaluate an effect of column aspect ratio (${\beta}_c={c_1}/{c_2}$=side length ratio of column section in the direction of lateral loading $(c_1)$ to the direction of perpendicular to $c_1$) on the hysteretic behavior under earthquake type loading. The aspect ratio of column section was taken as $0.5{\sim}3\;(c_1/c_2=1/2,\;1/1,\;2/1,\;3/1)$ and the column perimeter was held constant at 1200mm in order to achieve nominal vertical shear strength $(V_c)$ uniformly. Other design parameters such as flexural reinforcement ratio $(\rho)$ of the slab and concrete strength$(f_{ck})$ was kept constant as ${\rho}=1.0%$ and $f_{ck}=40MPa$, respectively. Gravity shear load $(V_g)$ was applied by 30 percent of nominal vertical shear strength $(0.3V_o)$ of the specimen. Experimental observations on punching failure pattern, peak lateral-load and story drift ratio at punching failure, stiffness degradation and energy dissipation in the hysteresis loop, and steel and concrete strain distributions near the column support were examined and discussed in accordance with different column aspect ratio. Eccentric shear stress model of ACI 318-05 was evaluated with experimental results. A fraction of transferring moment by shear and flexure in the design code was analyzed based on the test results.

Molecular phylogeny and divergence of photosynthetic pathways of Korean Cypereae (Cyperaceae) (한국산 방동사니족(사초과) 식물의 분자계통과 광합성경로의 분화)

  • Jung, Jongduk;Ryu, Youngil;Choi, Hong-Keun
    • Korean Journal of Plant Taxonomy
    • /
    • v.46 no.3
    • /
    • pp.314-325
    • /
    • 2016
  • Multiple changes of the photosynthesis pathway are independent evolutionary events occurring in the phylogeny of flowering plants, and such changes have occurred more than five times in Cyperaceae. In the tribe Cypereae, the C4 photosynthetic pathway appeared only once and is regarded as a synapomorphy of the C4 plants within this tribe. The morphological delimitation of genera within Cypereae does not correspond to their molecular phylogenetic relationships. In this study, the molecular phylogeny was compared with the photosynthetic pathways of Korean Cypereae (18 species of Cyperus, 1 species of Kyllinga, and 1 species of Lipocarpha). The photosynthetic pathways were determined by observing the leaf anatomy. The phylogenetic analysis was performed using three DNA regions (nrITS, rbcL, and trnL-F). According to the position of the photosynthetic tissue, 4 species (C. difformis, C. flaccidus, C. haspan, and C. tenuispica) and 16 species (14 Cyperus species, K. brevifolia var. leiolepis, and L. microcephala) were confirmed as C3 and C4 plants, respectively. Tribe Cypereae was divided into the CYPERUS and FICINIA clades, and all species of Korean Cypereae plants belonged to the CYPERUS clade in the phylogenetic analysis. Within the CYPERUS clade, C4 plants were monophyletic but their phylogenetic relationships were unclear. The genera Kyllinga and Lipocarpha were not supported as an independent genus in either case because they were nested by the Cyperus species in the molecular phylogenetic trees in the present and in previous studies. To determine the classification within the CYPERUS clade, a detailed morphological study and a molecular phylogenetic analysis at a high resolution will be necessary.

An Analysis of Proper Curriculum Organization Plan for Elementary and Secondary Invention/Intellectual Property Education (초·중등 발명·지식재산 교육과정의 적정 편성 방안 연구)

  • Lee, Kyu-Nyo;Lee, Byung-Wook
    • 대한공업교육학회지
    • /
    • v.42 no.1
    • /
    • pp.106-124
    • /
    • 2017
  • This study used the secondary Delphi method for experts, in order to propse a proper formation plan for the goal and curriculum of elementary and secondary invention/intellection property education. Its results are as following; First, the key objective of invention/intellectual property education for each school level is evaluated as appropriate. With regard to the key objective, elementary schools are aiming at 'fostering awareness and attitude for invention'(M=4.5), middle schools, 'understanding of invention process and method'(M=4.2), general high schools, 'application and evaluation of invention method'(M=4.1), and specialized high schools, 'understanding and application of Employee Invention'(M=4.6). The objective and goal of education for each school level are also evaluated as appropriate. Second, although the proper formation plans for a key learning element of elementary and secondary invention/intellectual property education were almost identical to an actual formation of preceding literature, overall change is required for the formation balance of each learning element, according to the objective and goal of school-leveled invention/intellectual property education. An appropriate formation shall be focusing on basic learning elements (A, B, C, D, E, and F) for elementary and middle schools(73.2%, 65.1%), lowering somewhat the former elements and increasing expanded learning elements for high schools(51.0%), which are connected to the invention, course(H), and patent application(K). Third, elementary and secondary invention/intellectual property education system should be oriented to its objective and goal. In order to reach this, an appropriate formation plan should be made for each school level, based on the principle of Tyler's learning organization, such as continuity, sequence and integration, which are key learning element. Specialized high schools, in particular, need to be differentiated from general ones, as well as elementary and middle schools. Additionally, for understanding and applying an employee invention, invention/intellectual property education system needs to be established in the phase of secondary occupational education.

Comparison of the Medication Effects between Milnacipran and Pregabalin in Fibromyalgia Syndrome Using a Functional MRI: a Follow-up Study (섬유근통 환자에 대한 Milnacipran과 Pregabalin 약물치료에 대한 기능적 자기공명영상에서의 후속 영향 비교)

  • Kang, Min Jae;Mun, Chi-Woong;Lee, Young Ho;Kim, Seong-Ho
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.4
    • /
    • pp.341-351
    • /
    • 2014
  • Purpose : In this study, the medication effects of Milnacipran and Pregabalin, as well known as fibromyalgia treatment medicine, in fibromyalgia syndrome patients were compared through the change of BOLD signal in pain related functional MRI. Materials and Methods: Twenty fibromyalgia syndrome patients were enrolled in this study and they were separated into two groups according to the treatment medicine: 10 Milnacipran (MLN) treatment group and 7 Pregabalin (PGB) treatment group. For accurate diagnosis, all patients underwent several clinical tests. Pre-treated and post-treated fMRI image with block-designed pressure-pain stimulation for each group were obtained to conduct the statistical analysis of paired t-test and two sample t-test. All statistical significant level was less than 0.05. Results: In clinical tests, the clinical scores of the two groups were not significantly different at pre-treatment stage. But, PGB treatment group had lower Widespread Pain Index (WPI) and Brief Fatigue Inventory (BFI) score than those of MLN treatment group at post-treatment stage. In functional image analysis, BOLD signal of PGB treatment group was higher BOLD signal at several regions including anterior cingulate and insula than MLN treatment group at post-treatment stage. Also, paired t-test values of the BOLD signal in MLN group decreased in several regions including insula and thalamus as known as 'pain network'. In contrast, size and number of regions in which the BOLD signal decreased in PGB treatment group were smaller than those of MLN treatment group. Conclusion: This study showed that MLN group and PGB group have different medication effects. It is not surprising that MLN and PGB have not the same therapeutic effects since these two drugs have different medicinal mechanisms such as antidepressants and anti-seizure medication, respectively, and different detailed target of fibromyalgia syndrome treatment. Therefore, it is difficult to say which medicine will work better in this study.

Comparison Study between Myocardial Velocity obtained from Gated Myocardial SPECT and Myocardial Functional indices with a Focus on Myocardial Perfusion (게이트 심근 관류 SPECT에서 구한 심근 속도와 심근 관류를 중심으로 한 심근 기능 지표와의 비교연구)

  • Ha, Jung-Min;Jeong, Shin-Young;Bom, Hee-Seung;Lee, Byeong-Il
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.5
    • /
    • pp.386-394
    • /
    • 2009
  • Purpose: We aimed to assess the myocardial velocity on gated myocardial perfusion SPECT (gated MPS), to compare myocardial velocity between patients without coronary artery disease (CAD) and CAD patients and to assess the correlation of myocardial velocity and perfusion and wall thickening on CAD group. Materials and Methods: Seventeen patients without CAD (M:F=9:8, mean age $61.8{\pm}11.1$ yrs: group A) and thirty-nine patients with CAD (M:F=18:21, mean age $66.9{\pm}8.1$ yrs : group B) had undergone one-day adenosine stress gated MPS. In twenty segment model, 12 segments (except apical and basal segments) of each patient were included. We obtained systolic and diastolic gate ratio in left ventricular volume curve by eight frames per cardiac cycle on gated MPS. Using the systolic and diastolic gate ratio and R-R time of each patient, we obtained systolic and diastolic time ratio. The myocardial velocity was defined as wall thickening over systolic or diastolic time. Results: We presented normal range of myocardial velocities according segments and territories of coronary artery. The myocardial velocity of group B was significantly lower than group A (p=0.00). There was no significant difference between the myocardial velocity of group B with preserved EF and group A. The stress systolic velocity significantly correlated with regional myocardial perfusion in group B with preserved EF (p=0.00) as well as decreased EF (p=0.01). In group B, stress perfusion of segments which had decreased wall thickening and decreased myocardial velocity was significantly lower than segments which had decreased wall thickening and preserved myocardial velocity (p=0.01). Conclusion: The new functional index of velocity will be used as an useful of gated MPS.

The Analysis and Migration of Bisphenol A Related Compounds from Metal Food Cans (식품용 금속 캔으로부터 비스페놀 A 관련 물질들의 분석 및 이행 연구)

  • Park, Se-Jong;Park, So-Ra;Choi, Jae Chun;Kim, MeeKyung
    • Journal of Food Hygiene and Safety
    • /
    • v.32 no.4
    • /
    • pp.329-335
    • /
    • 2017
  • Analysis method was presented for the simultaneous determination of nine bisphenol A related compounds such as bisphenol A (BPA), phenol, p-tert-butylphenol, bisphenol A diglycidyl ether (BADGE), $BADGE{\cdot}2H_2O$, $BADGE{\cdot}2HCl$, bisphenol F diglycidyl ether (BFDGE), $BFDGE{\cdot}2H_2O$ and $BFDGE{\cdot}2HCl$ migrated from inner coatings of metal food cans by high performance liquid chromatography (HPLC) with fluorescence detection. The method was validated by examining the linearity of calibration curve, the limit of detection (LOD), the limit of quantification (LOQ), recovery and uncertainty. The migration tests of nine BPA related compounds were carried out with four food simulants; deionized water (DW), 4% acetic acid, 50% ethanol and n-heptane. There was not any compound detected in DW, 4% acetic acid and 50% ethanol at $60^{\circ}C$ for 30 min and n-heptane at $25^{\circ}C$ for 60 min. BPA and phenol were migrated into 4% acetic acid and 50% ethanol at $95^{\circ}C$ for 30 min. The concentrations were ranged from 0 to $10.77{\mu}g/L$ of BPA and from 0 to $2.35{\mu}g/L$ of phenol. Canned foodstuffs mostly have long-term shelf life. We investigated migration of nine BPA related compounds according to the variation in storage periods (0~90 days) and temperatures (4, 25 and $60^{\circ}C$). All compounds were not founded during 90 days at $4^{\circ}C$ and $25^{\circ}C$, respectively. However BPA and $BADGE{\cdot}2H_2O$ were founded in DW and 4% acetic acid at $60^{\circ}C$. The migration levels of BPA and $BADGE{\cdot}2H_2O$ were close to the value of LOQ, respectively and did not change significantly as storage period. It was founded from results that the migration of BPA related compounds from metal food cans was controlled to a safe level.

A STUDY OF INSERTION DEPTH OF GUTTA PERCHA CONES AFTER SHAPING BY NI-TI ROTARY FILES IN SIMULATED CANALS (레진모형 근관에서 Ni-Ti 파일로 근관성형 후 거타퍼챠콘의 근관내 삽입깊이에 대한 연구)

  • Cho, Hyun-Gu;Hwang, Yun-Chan;Hwang, In-Nam;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.6
    • /
    • pp.550-558
    • /
    • 2007
  • The purpose of this study was to evaluate the insertion depth of several brands of master gutta percha cones after shaping by various Ni-Ti rotary files in simulated canals. Fifty resin simulated J-shape canals were instrumented with ProFile, ProTaper and HEROShaper. Simulated canals were prepared with ProFile .04 taper #25(n=10), .06 taper #25(n=10), ProTaper F2(n=10), HEROShaper .04 taper #25(n=10) and .06 taper #25(n=10). Size #25 gutta percha cones with a .04 & .06 taper from three different brands were used: DiaDent; META; Sure-endo. The gutta percha cones were selected and inserted into the prepared simulated canals. The distance from the apex of the prepared canal to the gutta percha cone tip was measured by image analysis program. Within limited data of this study, the results were as follows 1. When the simulated root canals were prepared with HEROShaper, gutta-percha cones were closely adapted to the root canal. 2. All brands of gutta percha cones fail to go to the prepared length in canal which was instrumented with ProFile, the cones extend beyond the prepared length in canal which was prepared with ProTaper. 3. In canal which was instrumented with HEROShaper .04 taper #25, Sure-endo .04 taper master gutta percha cone was well fitted(p < 0.05). 4. In canal which was instrumented with HEROShaper .06 taper #25, META .06 taper master gutta percha cone was well fitted(p < 0.05). As a result, we concluded that the insertion depth of all brands of master gutta percha cone do not match the rotary instrument, even though it was prepared by crown-down technique, as recommended by the manufacturer. Therefore, the master cone should be carefully selected to match the depth of the prepared canal for adequate obturation.