• Title/Summary/Keyword: F-22A

Search Result 2,267, Processing Time 0.033 seconds

CHAIN RECURRENCE AND ATTRACTORS IN GENERAL DYNAMICAL SYSTEMS

  • Lee, Kyung-Bok;Park, Jong-Shu
    • Communications of the Korean Mathematical Society
    • /
    • v.22 no.4
    • /
    • pp.575-586
    • /
    • 2007
  • We introduce here notions of chain recurrent sets, attractors and its basins for general dynamical systems and prove important properties including (i) the chain recurrent set CR(f) of f on a metric space (X, d) is the complement of the union of sets B(A) -A as A varies over the collection of attractors and (ii) genericity of general dynamical systems.

Expession of the Recombinant Klebsiella aerognes UreF Protein as a MalE Fusion

  • Kim, Keun-Young;Yang, Chae-Ha;Lee, Mann-Hyung
    • Archives of Pharmacal Research
    • /
    • v.22 no.3
    • /
    • pp.274-278
    • /
    • 1999
  • Expression of the active urease of the enterobacterium, Klebsiella aerogens, requires the presence of the accessory genes (ureD, ureE, ureF, and ureG) in addition to the three structural genes (ureA, ureB, and ureC). These accessory genes are involved in functional assembly of the nickel-metallocenter for the enzyme. Characterization of ureF gene has been hindered, however, since the UreF protein is produced in only minute amount compared to other urease gene products. In order to overexpress the ureF gene, a recombinant pMAL-UreF plasmid was constructed from which the UreF was produced as a fusion with maltose-binding protein. The MBP-UreF fusion protein was purified by using an amylose-affinity column chromatography followed by an anion exchange column chromatography. Polyclonal antibodies raised against the fusion protein were purified and shown to specifically recognize both MBP and UreF peptides. The UreF protein was shown to be unstable when separated from MBP by digestion with factor Xa.

  • PDF

SOLUTION AND STABILITY OF MIXED TYPE FUNCTIONAL EQUATIONS

  • Jun, Kil-Woung;Jung, Il-Sook;Kim, Hark-Mahn
    • Journal of the Chungcheong Mathematical Society
    • /
    • v.22 no.4
    • /
    • pp.815-830
    • /
    • 2009
  • In this paper we establish the general solution of the following functional equation with mixed type of quadratic and additive mappings f(mx+y)+f(mx-y)+2f(x)=f(x+y)+f(x-y)+2f(mx), where $m{\geq}2$ is a positive integer, and then investigate the generalized Hyers-Ulam stability of this equation in quasi-Banach spaces.

  • PDF

Experimental analysis of rocking shallow foundation on cohesive sand

  • Moosavian, S.M. Hadi;Ghalandarzadeh, Abbas;Hosseini, Abdollah
    • Earthquakes and Structures
    • /
    • v.22 no.6
    • /
    • pp.597-608
    • /
    • 2022
  • One of the most important parameters affecting nonlinearsoil-structure interaction, especially rocking foundation, is the vertical factor of safety (F.Sv). In this research, the effect of F.Sv on the behavior of rocking foundations was experimentally investigated. A set of slow, cyclic, horizontal loading tests was conducted on elastic SDOF structures with different shallow foundations. Vertical bearing capacity tests also were conducted to determine the F.Sv more precisely. Furthermore, 10% silt was mixed with the dry sand at a 5% moisture content to reach the minimum apparent cohesion. The results of the vertical bearing capacity tests showed that the bearing capacity coefficients (Nc and Nγ) were influenced by the scaling effect. The results of horizontal cyclic loading tests showed that the trend of increase in capacity was substantially related to the source of nonlinearity and it varied by changing F.Sv. Stiffness degradation was found to occur in the final cycles of loading. The results indicated that the moment capacity and damping ratio of the system in models with lower F.Sv values depended on soil specifications such cohesiveness or non-cohesiveness and were not just a function of F.Sv.

A Study on the Energy and Time Characteristics of $BaF_2$ Scintillation Detector ($BaF_2$ 검출기의 시간과 에너지 특성연구)

  • Ju, Gwan-Sik;Park, Il-Jin;Kim, Jong-Ho;Nam, Gi-Yong;Baek, Seung-Hwa
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.3
    • /
    • pp.267-272
    • /
    • 1997
  • he scintillation detector having $BaF^2$ crystal with 3.6cm dia${\times}$2.0 cm thick was provided. The energy and timing characteristics were measured and compared with NaI(Tl) scintillation detectors, which widely used in unclear medicine. In order to measure the energy spectrum, the radioactive sources used were $^{22}Na,\;^{54}Mn,\;^{57}Co,\;^{137}Cs$ and the source to detector distance was 7cm. For the timing characteristic, NaI(Tl)(1" ${\times}$ 1")-$BaF^2$ and NaI(Tl)(3" ${\times}$ 3")-$BaF^2$ timing coincidence systems were prepared and the used source was $^{22}Na$ emitting 511keV annihilation photons. For the 511keV gamma-ray emitted from $^{22}Na$, It was revealed that the timing response of the $BaF^2$ detector was faster than NaI(Tl)(1" ${\times}$ 1") and NaI(Tl)(3" ${\times}$ 3") detector used in this experimental investigation. The energy characteristics of the $BaF^2$ detector had a good values for about 500keV energy range.

  • PDF

A Study on Exposure Among Asbestos Textile Workers and Estimation of their Historical Exposures (석면방직업 근로자의 석면노출 실태와 과거농도 추정에 관한 연구)

  • Park, Jeong Im;Yoon, Chung Sik;Paik, Nam Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.5 no.1
    • /
    • pp.16-39
    • /
    • 1995
  • From July 8 to September 2 1994, asbestos exposure level among asbestos textile workers was surveyed. Six plants out of plants in Korea were selected for this study. In addition to the exposure level, the relationship between the level of exposure and some factors affecting exposure were studied. Also, using historical data of asbestos concentrations in asbestos textile plants plus current data, trend of asbestos exposure level could be introduced. Historical exposure level was estimated on the basis of these data. The main results of this study are follows. 1. Average concentration of all six plants surveyed was 1.54 f/cc, and range of those concentrations was 0.03 - 11.58 f/cc. The minimum average concentration was 0.32 f/cc and the maximum was 8.04 f/cc which is four times higher than the Korean standard. A wide difference of exposure level among the workers of different plants was observed. In three plants, the half of all the plants surveyed, their average concentrations exceeded the Korean standard, and those in all the plants exceeded the ACGIH TLV. 2. Among total 56 samples, 22 samples(39%) were in excess of the Korean standard, and 53 samples(95%) were above the ACGIH TLV. Among 32 personal samples, 15 samples(47%) exceeded the Korean standard, and 30 samples(94%) exceeded the ACGIH TLV. Among 24 area samples excluding a few samples collected in office area, seven samples exceeded the Korean standard, and 23 samples( 96%) exceeded the ACGIH TLV. 3. Distributions of concentrations were observed by processes. In weaving, the highest, average concentration was 4.29 f/cc, and range was 2.61 - 11.58 f/cc. In spinning, average concentration was 2.22 f/cc, and range was 0.41 - 8.93 f/cc. In carding, average concentration was 1.98 f/cc, and range was 0.23 - 10.93 f/cc, In twisting, average concentration was 1.65 f/cc, and range was 0.21 - 9.83 f/cc. In mixing, the lowest, average concentration was 0.48 f/cc, and range was 0.22 - 1.20 f/cc. 4. All the samples from basic processes of asbestos textile plants were above the ACGIH TLV. Nineteen samples(45%) out of all these 42 samples exceeded Korean standard. Fourteen samples(58%) of total 24 personal samples, and five samples(28%) of total 18 area samples exceeded the Korean standard. Considering processes, all the samples in weaving process exceeded the Korean standard and 50 did 54% of those in spinning, 40% in carding, and 27% in twisting. 5. Trend of decreasing asbestos concentrations in asbestos textile plants was observed by time. 6. Asbestos concentrations in asbestos textile plant in 1975 were estimated to be 11.0 - 92.4 f/cc.

  • PDF

Considering the Multi-Purpose Display Designed for Aircraft Lightning Protection (낙뢰보호를 고려한 항공기용 다목적 디스플레이 설계)

  • Cheon, Young-Ho;Lee, Seoung-Pil;Park, Jun-Hyeon
    • Journal of Advanced Navigation Technology
    • /
    • v.18 no.5
    • /
    • pp.445-454
    • /
    • 2014
  • In this paper, we introduce measures designed content for RTCA DO-160 F, Section 22 tests performed to verify the effects of indirect lightning and testing process of the test was carried out in the multi-purpose display certification process. This is referred to as indirect effects of lightning capability of an aircraft having electrical electronic equipment failure or damage to bring lightning induced voltages. In order to protect the avionics from lightning indirect effects of these aircraft are analyzing the effects of lightning strikes on aircraft and aircraft systems and interior design needs protection against the threat on their part. In this paper, we introduce RTCA DO-160 F, component selection process according to Section 22 category selection method and the selected level for determining the level of such measures for protection against lightning of multipurpose display for this aircraft. It also introduces the actual test process to confirm that the designed effectiveness of the selected part. We expect a good example of the lightning planned for future development of measures designed avionics through each step of the process introduced this.

SOME APPLICATIONS OF EXTREMAL LENGTH TO CONFORMAL IMBEDDINGS

  • Chung, Bo-Hyun
    • Journal of the Chungcheong Mathematical Society
    • /
    • v.22 no.2
    • /
    • pp.211-216
    • /
    • 2009
  • Let G be a Denjoy domain and let G' a Denjoy proper subdomain of G and homeomorphic to G. We consider conformal re-imbeddings of G' into G. Let G and G' are N-connected. We know that if N = 2, there is a re-imbedding f of G' into G such that G - cl(f(G')) has an interior point. In this note, we obtain the following theorem. If $N{\geq}3$, G has a Denjoy proper subdomain G' such that, for any re-imbeddings f of G' into G, G - cl(f(G') has no interior point.

  • PDF

Properties of SBS-modified Warm-mix Asphalt Binders (SBS 개질 준고온 아스팔트 바인더의 특성)

  • Kim, Sung Un;Lee, Sung Jin;Youn, Yeo;Kim, Kwang Woo
    • International Journal of Highway Engineering
    • /
    • v.16 no.2
    • /
    • pp.19-24
    • /
    • 2014
  • PURPOSES : The study objective was to evaluate rheology and physical properties of SBS-modified warm-mix asphalt (WMA) binders in comparison with hot-mix asphalt (HMA) binders. METHODS : Four different SBS polymers were used to prepare polymer-modified asphalt (PMA) binders, and three different warm-mix additives (WAD) were used to prepare a total of 12 WMA PMA binders. The kinematic viscosity was measured at 115, $135^{\circ}C$. The PG was determined using DSR and BBR. The pass/fail (P/F) temperatures for high and low PG grading were evaluated for HMA PMA and WMA PMA binders. RESULTS : PG 76-22 binders could be prepared by modifying the base binder (PG 64-22) using 4.5 wt% of SBS. The kinematic viscosity (KV) of SBS PMA was increased by 3 times higher than that of base asphalt. The SBS PMA with WAD showed 10% lower KV than that of the normal SBS PMA at $115^{\circ}C$ The high P/F temperatures showed almost no difference between HMA PMA and WMA PMA binders. The high P/F temperature showed very high correlations with KV ($R^2$ > 0.97). The result of SBS modification caused increase of low P/F temperature by $2.7^{\circ}C$ on average. CONCLUSIONS : Since the PMA with WAD showed 10% lower KV than normal (HMA) PMA at $115^{\circ}C$, reducing PMA mixture temperature down to a WMA level was possible in this study. The higher KV binders showed the higher P/F temperature. There was almost no change in high P/F temperature due to the use of WAD. The SBS PMA, showing an increased low P/F temperature, might show somewhat poorer performance at low-temperature, even though the lower PG grade was staying at the same level, i.e., $-22^{\circ}C$.

SOME GENERALIZATION OF THE LANG'S EXISTENCE OF RATIONAL PLACE THEOREM

  • Cho, In-Ho;Lim, Jong-In
    • Bulletin of the Korean Mathematical Society
    • /
    • v.22 no.2
    • /
    • pp.83-85
    • /
    • 1985
  • Let K be a real function field over a real closed field F. Then there exists an F-place .phi.:K.rarw.F.cup.{.inf.}. This is Lang's Existence of Rational Place Theorem (6). There is an equivalent version of Lang's Theorem in (4). That is, if K is a function field over a field F, then, for any ordering P$_{0}$ on F which extends to K, there exists an F-place .phi.: K.rarw.F'.cup.{.inf.} where F' is a real closure of (F, P$_{0}$). In [2], Knebusch pointed out the converse of the version of Lang's Theorem is also true. By a valuation theoretic approach to Lang's Theorem, we have found out the following generalization of Lang and Knebusch's Theorem. Let K be an arbitrary extension field of a field F. then an ordering P$_{0}$ on F can be extended to an ordering P on K if there exists an F-place of K into some real closed field R containing F. Of course R$^{2}$.cap.F=P$_{0}$. The restriction K being a function field of F is vanished, though the codomain of the F-place is slightly varied. Therefore our theorem is a generalization of Lang and Knebusch's theorem.

  • PDF