• Title/Summary/Keyword: F/A-18E/F

Search Result 435, Processing Time 0.031 seconds

Evaluate Utility of Thyroid Cancer Discrimination by 18F-FDG PET/CT Delay Scan Images (18F-FDG PET/CT검사에서 지연영상을 이용한 갑상선암 진단의 유용성 평가)

  • Lee, Hyeon-Guck;Han, Man-Seok;Kim, Yong-Kyun;Seo, Sun-Youl;Jeon, Min-Cheol;Kim, Tae-Hyung;Hong, Seong-Jong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.6
    • /
    • pp.2958-2965
    • /
    • 2013
  • Purpose : To evaluate the degree of malignancy of incident thyroid lesion found in 18F-FDG PET/CT findings and the usefulness of the method suggested in this study, we applicate the Delay Scan Method that differentiate a false positive benign tumor, inflammation and malignancy, as well as make the criteria of SUV. Materials and Methods : A retrograde study was conducted of 25 patients(1 exception) who were admitted in E hospital to receive 18F-FDG PET/CT examination until Janaary and April of 2008. 18F-FDG PET/CT image photographing was taken in Biograph-Duo made by SIEMENS, after taking normal 18F-FDG PET/CT image(1hr) and then 1hr later we took the thyroid 1 bed-delayed image for the patients who showed abnormal thyroid 18F-FDG uptake and above 2.0 SUV for 2 minutes every 1 bed. For the patients who showed abnormal thyroid uptake and above 2.0 SUV, 1hr later, we took a 1 bed-delayed image and then made a comparative study between measured maxSUV of 1hr-abnormal uptake image and that of 2hr-delayed image. Results : In this 18F-FDG PET/CT study among the patients who showed incidental 18F-FDG thyroidal uptake the number of thyroid cancer was 5(20.8%), all of then showed benign findings. a comparison of results for 18F-FDG PET/CT. the benign patient measured maxSUV in the PET/CT. image(1hr) mean value 5.06maxSUV and delay image(2hr) mean value 5.23maxSUV differences of two value is 0.19maxSUV and the malignantIt patient measured maxSUV in the PET/CT. image(1hr) mean value 9.63maxSUV and delay image(2hr) mean value 10.65maxSUV differences of two value is 10.65maxSUV in Thyroid abnormal uptake patients. Conclusion : in the case of incidental 18F-FDG uptake in thyroid, max SUV of focal thyroid lesion is above 5.0 if 18F-FDG PET/CT examine the delayed images to add, You could see that reasonable diagnostic method useful. to differentiate whether lesions of malignant.

Synthesis and Biodistribution of Flumazenil Derivative [F-18](3-(2-Fluoro) flumazenil for Imaging Benzodiazepine Receptor (벤조디아제핀 수용체 영상용 양전자 방출 핵종 표지 플루마제닐 유도체 [F-18](3-(2-Fluoro)flumazenil의 합성과 생체 내 분포)

  • Hong, Sung-Hyun;Jeong, Jae-Min;Chang, Young-Soo;Lee, Dong-Soo;Chung, June-Key;Cho, Jung-Hyuck;Lee, Sook-Ja;Kang, Sam-Sik;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.6
    • /
    • pp.527-536
    • /
    • 1999
  • Purpose: Radiotracers that bind to the central benzodiazepine receptor are useful for the investigation of various neurological and psychiatric diseases. [C-11]Flumazenil, a benzodiazepine antagonist, is the most widely used radioligand for central benzodiazepine receptor imaging by PET. We synthesized 3-(2-[F-18]fluoro)flumazenil, a new fluorine-18 ($t_{1/2}$= 110 min) labeled analogue of benzodiazepine receptor imaging agent, and evaluated in vivo for biodistribution in mice. Materials and Methods: Flumazenil (Ro 15-1788) was synthesized by a modification of the reported method. Precursor of 3-(2-[F-18]fluoro)flumazenil, the tosylated flumazenil derivative was prepared by the tosylation of the ethyl ester by ditosylethane. [F-18] labeling of tosyl substitued flumazenil precursor was performed by adding F-18 ion at $85^{\circ}C$ in the hot ceil for 20 min. The reaction mixture was trapped by C18 cartridge, washed with 10% ethanol, and eluted by 40% ethanol. Bidistribution in mice was determined after intravenous injection. Results: The total chemical yield of tosylated flumazenil derivative was ${\sim}40%$. The efficiency of labeling 3-(2-[F-18]fluoro)flumazenil was 66% with a total synthesis time of 50 min. Brain uptakes of 3-(2-[F-18]fluoro)flumazenil at 10, 30, 60 min after injection, were $2.5{\pm}0.37,\;2.2{\pm}0.26,\;2.1{\pm}0.11$ and blood activities were $3.7{\pm}0.43,\;3.3{\pm}0.07,\;3.3{\pm}0.09%ID/g$, respectively. Conclusion: We synthesized a tosylated flumazenil derivative which was successfully labeled with no-carrier-added F-18 by nucleophilic substitution.

  • PDF

ALMOST LINDELÖF FRAMES

  • Khang, Mee Kyung
    • Korean Journal of Mathematics
    • /
    • v.18 no.1
    • /
    • pp.45-52
    • /
    • 2010
  • Generalizing $Lindel{\ddot{o}}f$ frames and almost compact frames, we introduce a concept of almost $Lindel{\ddot{o}}f$ frames. Using a concept of ${\delta}$-filters on frames, we characterize almost $Lindel{\ddot{o}}f$ frames and then have their permanence properties. We also show that almost $Lindel{\ddot{o}}f$ regular $D({\aleph}_1)$ frames are exactly $Lindel{\ddot{o}}f$ frames. Finally we construct an almost $Lindel{\ddot{o}}fication$ of a frame L via the simple extension of L associated with the set of all ${\delta}$-filters F on L with ${\bigvee}\{x^*{\mid}x{\in}F\}=e$.

Development of Finite Element Model of Hybrid III 5th Percentile Female Dummy (Hybrid III 5% 성인 여성 더미의 유한요소 모델 개발)

  • Yi, Sang-Il;Mohan, Pradeep K.;Kan, Cing-Dao Steve;Park, Gyung-Jin
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.18 no.4
    • /
    • pp.18-30
    • /
    • 2010
  • As the automobile industry is developing, the number of deaths and injuries has increased. To reduce the damages from automobile accidents, the government of each country proposes experimental conditions for reproducing the accident and establishes the vehicle safety regulations. Automotive manufacturers are trying to make safer vehicles by satisfying the requirements. The Hybrid III crash test dummy is a standard Anthropomorphic Test Device (ATD) used for measuring the occupant's injuries in a frontal impact test. Since a real crash test using a vehicle is fairly expensive, a computer simulation using the Finite Element Method (F.E.M.) is widely used. Therefore, a detailed and robust F.E. dummy model is needed to acquire more accurate occupant injury data and behavior during the crash test. To achieve this goal, a detailed F.E. model of the Hybrid III 5th percentile female dummy is constructed by using the reverse engineering technique in this research. A modeling process is proposed to construct the F.E. model. The proposed modeling process starts from disassembling the physical dummy. Computer Aided Design (CAD) geometry data is constructed by three-dimensional (3-D) scanning of the disassembled physical dummy model. Based on the geometry data, finite elements of each part are generated. After mesh generation, each part is assembled with other parts using the joints and rigid connection elements. The developed F.E. model of dummy is simulated based on the FMVSS 572 validation regulations. The results of simulation are compared with the results of physical tests.

The Experimental Effect of Haedongpibokhap-bang (Hǎitóngpífùhé-fāng) on Collagen-induced Arthritis (해동피복합방(海桐皮複合方)이 Collagen II 유발 관절염에 미치는 실험적 연구)

  • Kung, Shyang-En;Oh, Min-Seok
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.18 no.2
    • /
    • pp.1-15
    • /
    • 2008
  • Objectives : The aim of this study was to know the immunity response of Haedongpibokhap-bang($H{\check{a}}it{\acute{o}}ngp{\acute{i}}f{\grave{u}}h{\acute{e}}-f{\bar{a}}ng$) to rheumatoid arthritis in collagen-induced arthritis(CIA) mice. Methods : For this purpose, Haedongpibokhap-bang($H{\check{a}}it{\acute{o}}ngp{\acute{i}}f{\grave{u}}h{\acute{e}}-f{\bar{a}}ng$) was orally administerd to mice with arthritis induced by collagen II and then value of immunocyte in spleen, draining lymph node and paw joint and cytokine(IL-6, $TNF-{\alpha}$), rheumatoid factor (IgG and IgM) in serum were measured. Results : 1. The arthritis index was significantly decreased. 2. In total cell counts of spleen, DLN and paw joint, the cells in spleen decreased while there was a significant increase in DLN and significant decrease in paw joint. 3. In lymph nodes, CD3+, CD3+/CD69+, CD4+, CD8+ cells increased significantly. 4. In joints, CD3+ and CD11+b/Gr-1+ cells decreased significantly. 5. Serum IL-6 and $TNF-{\alpha}$ were decreased significantly. 6. Production of serum IgG and IgM decreased significantly. Conclusions : The results present that Haedongpibokhap-bang($H{\check{a}}it{\acute{o}}ngp{\acute{i}}f{\grave{u}}h{\acute{e}}-f{\bar{a}}ng$) controls abnormal activity of immune system, inhibitig collagen-induced arthritis(CIA).

40.8 MHz coherent scatter ionospheric radar observations of E- and F-region field aligned irregularities over Korea

  • Yang, Tae-Yong;Kwak, Young-Sil;Lee, Jae-Jin;Choi, Seong-Hwan;Hwang, Jung-A;Park, Young-Deuk
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.2
    • /
    • pp.81.1-81.1
    • /
    • 2011
  • The new coherent scatter ionospheric radar has been operating at Gyerong city ($36.18^{\circ}N$, $127.14^{\circ}E$, dip lat $26.7^{\circ}N$), South Korea. This VHF radar is consisted of 24 Yagi antennas having 5 elements and observes the E- and F-region field-aligned irregularities (FAIs) in a single frequency of 40.8 MHz with a peak power of 24 kW. We present the first results of the E- and F-region FAIs over Korea by using the new VHF coherent scatter ionospheric radar. The morphological and echo characteristics are studied in terms of their echo strength, Doppler velocity and also by spectral width values. From the continuous observations from December 2009, we found ionospheric E- and F-region FAIs appeared frequently. The most interesting and striking observations for E region are occurrence of daytime E-region irregularities and strong Quasi-Periodic (QP) echoes at nighttime. And for F region, strong post-sunset and pre-sunrise FAIs appeared frequently. The VHF radar observations over Korea are discussed in the light of current understanding of mid-latitude E- and F-region FAIs.

  • PDF

Reduction of Injection Dose in 18F-FDG Fusion PET (PET-CT 검사에서 18F-FDG 투여량 감소에 대한 고찰)

  • Kim, Jong-Pil;Kim, Jae-Il;Lee, Hong-Jae;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.17-21
    • /
    • 2014
  • Purpose With the recent rise of social issue regarding radiation exposure, attention to medical radiation use has been placed under a great spotlight. During PET-CT examination, generally about 40% more of $^{18}F$-FDG is used than EANM recommendation. While maintaining the diagnostic test result, we hope to find optimal injection dose to minimize the $^{18}F$-FDG in patients by utilizing the latest PET-CT scanner which is equiped with the newest technology. Materials and Methods During this experiment, the Biograph Truepoint 40 (siemens, USA) installed in 2007 and mCT 64 (siemens, USA) installed in 2011 were used and evaluated NECR (noise-equivalent counting rate) by using a scatter phantom. For the image quality evaluation of each scanner, we injected 3.7, 4.44 and 5.18 MBq/kg of $^{18}F$-FDG in NEMA IEC Body Phantom and also evaluated SNR between two scanners by using the data acquired at 60, 70, 80, 90, 100, 110 and 120 sec per bed. For the clinical evaluation, actual data of patients who were injected $^{18}F$-FDG 3.7, 4.44, 5.18 MBq/kg were used to compare SNR and draw a final result. Results As a result, mCT 64 peak NECR value was 1.65e+005, which is 10% higher than Turepoint 40. SNR values using the IEC body phantom was 17.9%, 17.4% and 17.1% higher in $^{18}F$-FDG 3.7 MBq/kg, 4.44 MBq/kg and 5.18 MBq/kg. In clinical patients, SNR values of the image mCT 64 was 16.5, which is 25% higher than Turepoint 40 scanner. Conclusion To draw a conclusion from the test result of this experiment, the same quality of SNR could be attained even with 10% reduced injection dose, if when the duration is extended by 10 sec/bed. This optimal result was possible due to enhanced equipment. The NECR (one of the equipment's performance assessment criteria for the scanner) increased by 10% and the SNR (one of the image quality assessment criteria) also increased by 17.5%. Therefore, we can expect to reduce the injection dose without deterioration of image quality. In consequence, it will also help to decrease the patient's anxiety of the radiation exposure.

  • PDF

J-Integral Evaluation of Concrete Fracture Characteristics

  • Choi, Sin-Ho;Kye, Hae-Ju;Kim, Wha-Jung
    • International Journal of Concrete Structures and Materials
    • /
    • v.18 no.3E
    • /
    • pp.183-189
    • /
    • 2006
  • Many researchers have recently proposed various parameters, variables of models and experimental methods to evaluate fracture properties of concrete, and their developments allow us to analyze the non-linear and quasi-brittle fracture mechanisms. This paper presents a brief treatment of the fracture parameters. Additionally, three-point bending tests were conducted to compare J-integral($J_{Ic}$) with other parameters($K_{Ic},\;G_{Ic},\;and\;G_F$). The change in parameter values with respect to the width and notch length of concrete beam specimens was also considered. The load-displacement curves were used to measure the concrete fracture toughness experimentally. From the results of experiment, it was found that the value of $G_F\;and\;J_{Ic}$ decreased as the notch depth increased and that $G_F$ was less sensitive than $J_{Ic}$. Therefore, the former, $G_F$, is more appropriate in using it as the concrete fracture toughness parameter. The values of $G_F\;and\;J_{Ic}$ increased when the width of concrete specimens increasing from 75 mm to 150 mm. Thus, the effects of the specimen width should be considered in determining the fracture toughness of concrete.

A Study on the Fatigue-Fractured Surface of Normalized SS41 Steel and M.E.F. Dual Phase Steel by an X-ray Diffraction Technique (X-선 회절에 의한 SS41 불림재와 M.E.F. 복합 조직강의 피로 파단면 해석에 관한 연구)

  • Oh, Sae-Wook;Park, Young-Chul;Park, Soo-Young;Kim, Deug-Jin;Hue, Sun-Chul
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.16 no.1
    • /
    • pp.10-18
    • /
    • 1996
  • This study verified the relationship between fracture mechanics parameters and X-ray parameters for normalized SS41 steel with homogeneous crystal structure and M.E.F. dual phase steel(martensite encapsulated islands of ferrite). The fatigue crack propagation test were carried out and X-ray diffraction technique was applied to fatigue fractured surface. The change in X-ray parameters(residual stress, half-value breadth) according to the depth of fatigue fractured surface were investigated. The depth of maximum plastic zone, $w_y$, were determined on the basis of the distribution of the half-value breadth for normalized SS41 steel and that of the residual stress for M.E.F. dual phase steel. $K_{max}$ could be estimated by the measurement of $w_y$.

  • PDF

The Rietveld Structure Refinement of Natural Phlogopite Using Neutron Powder Diffraction (중성자분말회절법을 이용한 금운모 결정에 대한 리트벨트 구조분석)

  • 이철규;송윤구;전철민;김신애;성기훈
    • Journal of the Mineralogical Society of Korea
    • /
    • v.16 no.3
    • /
    • pp.215-222
    • /
    • 2003
  • The Rietveld structure refinement for the natural trioctahedral mica, phlogopite-1M (Parker Mine, Quebec, Canada) has been done by high resolution neutron powder diffraction at $25^{\circ}C$ and -263$^{\circ}C$. The structural formula of phlogopite determined by electron probe microanalysis is $K_2$(M $g_{4.46}$F $e_{0.83}$A $l_{0.34}$ $Ti_{0.22}$)(S $i_{5.51}$A $l_{2.49}$) $O_{20}$(O $H_{3.59}$ $F_{0.41}$). Cell parameters are a=5.30∼5.31 $\AA$, b=9.18∼9.20 $\AA$, c=10.18∼10.21 $\AA$, $\beta$=100.06∼100.08$^{\circ}$. Refinements converged to R values in the range of $R_{p}$=2.35%, $R_{wp}$=3.01%, respectively. In this study, the OH bond length is calculated to 0.93 $\AA$ at room temperature and 1.03 $\AA$ at -263$^{\circ}C$, and the angles between OH vector and (001) plane are obtained 93.4$^{\circ}$∼93.6$^{\circ}$. The decrease in the length of OH with the increase in temperature should be due to the hydrogen bonding in the structure of phogopite.e.e.f phogopite.e.e.