• Title/Summary/Keyword: Eyeball

Search Result 176, Processing Time 0.024 seconds

A Change of fashin IIIustration by the Ideal Type of Human Body Beauty (인체미의 이상형에 따른 패션 일러스트레이션의 변화)

  • 전경숙
    • Journal of the Korean Society of Costume
    • /
    • v.28
    • /
    • pp.65-84
    • /
    • 1996
  • The purpose of this study is to analyze the relation between the beauty of human body and the fashion illustration in each period And I attained my object through the investigation of features and changes of illustration which is given a vivid description of the features and development of ideal humam body beauty. By various methods I studied this subject. Frist I refered to sundry records Secondly I investiated the fashion illustrations which are included in Vogue. On the basis of this data I grasped the ideal types of human body beauty which is founded during the social change in each 10 years. And I analyzed the relation be-tween the ideal type and fashion illustration which show the change of fashion. The summary of result is as follows. 1. In the early part of the 20th century the beauty of human body is represented with the figure of large-sized beauty which emphasize shoulder and bust. And fashion ikllustration show 9 life-size broad shoulder full bust lim waist and hourglass silhouette. 2, In the 1910s the swell of strength vanishes gradually and shoulder and sleeve are straight type. And fashion illustration show 7 life-size high waist line. And that is tublar sil-houette of high waist and streamline shape in which bust and hip are not emphasized. 3. In the 1920s the ideal type of human body beauty is straight type which shows flat bust and unexaggerate hip. And fashion illus-tration is about 8 life-size tublar silhouette of low waist and lunger and slimmer and young style in which bust and hip are not emph-asized. 4. In the 1930s the ideal is womamly slim and long style. Fashion illustration is about 8 life-size and slim & long silhouette in which waist line is emphasized and bust and hip line come out. 5. In the 1940s the ideal type is womamly style which has narrow shoulder rich bast and slim waist. And fashion illustration is about 7 life-size and hourglass silhouette which has unartificial shoulder slim waist and empha-sized bust. 6. In the 1950s the ideal type is that of ro-bust health which emphasize build and muscu-lar system. And fashion illustration is 8.5 life-size and show full bust and made waist slimmer. That is sheath silhouette. 7. In the child who has full face with large eyeball slender and long leg: narrow and immatured body comparatively big head. And fashion illus-tration is 7 life-size and show slim and long neck flat bust long and slim limbs and big head. That is H type silhouette. 8. In the 1970s the ideal type is high stat-ure flat breast small hip and wide shoulders. And fashion illustration is wide shoulders and slim waist as 11 life-size and straight sil-houete. 9. In the 1980s the ideal type is extremely emphasized breadth of shoulder because healthy body and muscle are recognized as the symbol of ideal attractiveness. And fashion il-lustration is about 8.5 life-size and show mus-cular slim type that is slim silhouette. 10 At the present time the ideal type is slim and tall type which is empasized healthy beauty. And fashion illustration is 12 life-size which has healthy body and skin So that is slim and long type.

  • PDF

Correlation of Refractive Error, Axial Length, Chamber Depth, Lens Thickness and Corneal Thickness of Normal University Students (정상 대학생의 눈 굴절이상, 안축장, 전방깊이, 수정체두께 그리고 각막두께의 연관성)

  • Kim, Chang-Sik;Lee, Hak-Jun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.1
    • /
    • pp.89-94
    • /
    • 2008
  • Purpose: To make a comparative study of correlation between biometry data of size in eyeball and refractive error. Methods: The subjects were 68 normal university students (male 36, female 32) and the average age was 22.85${\pm}$3.12. We measured the students' eyesight by A-scan ultrasound and refractor. The results were examined it's statistical significance by SPSS 12.0 version. Results: The mean of axial length was 24.31${\pm}$1.24 mm, chamber depth was 3.48${\pm}$0.28 mm, lens thickness was 3.56${\pm}$0.26 mm and corneal thickness was 0.55${\pm}$0.03 mm. Male's Axial length and chamber depth were larger than female's. As reflective error decreases the thickness of lens become thicker. The measurement data between right eye and left eye didn't had difference and there was no correlation with result of T-test. There were statistically significant correlation with length and chamber depth, axial length and corneal thickness, chamber depth and corneal thickness, and refractive error and lens thickness (p<0.01). Refractive error and axial length were minus linear regression (r=-0.56). Conclusions: Eye's refractive error was changed by axial length, chamber depth and lens thickness but it wasn't related with sex and whether it is a right eye or a left eye.

  • PDF

EFFECTS OF THE SITE AND THE EXTENT OF BLOWOUT FRACTURE ON ENOPHTHALMOS AND DIPLOPIA (Blowout 골절의 부위와 정도가 안구함몰 및 복시에 미치는 영향)

  • Hwang, Ung;Ryu, Sun-Youl
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.30 no.4
    • /
    • pp.292-300
    • /
    • 2004
  • Orbital blowout fractures are common consequence to blunt periorbital trauma. Pure orbital blowout fractures first occur at the weakest point of the orbital wall. Computed tomography(CT) is recognized to be the best imaging technique to evaluate orbital fractures. The extent and location of a blowout fractures in the CT scan were noted to have an effect on the clinical outcome. In the early posttraumatic period, the presence of significant enophthalmos is difficult to detect because of orbital edema. Early surgical intervention may improve the ultimate outcome because open reconstruction becomes more difficult if surgery is delayed. In this study, we evaluated isolated blowout fractures of the orbital floor by region-of-interest measurements from CT scans and their relationship to ophthalmologic findings. Six patients of the medial orbital wall fractures, eleven patients of the inferior orbital wall fractures, nineteen of the medial and the inferior orbital wall fractures confirmed by CT scan, were evaluated. The area of fracture and the volume of the displaced orbital tissue were determined from CT scan using linear measurements. Each of the calculated values for the area and the volume were compared with the degree of the enophthalmos, the diplopia, and the eyeball movement limitation to determine whether there was any significant relationship between them. The fracture area and the volume of the herniated orbital tissue were significantly positively correlated with the enophthalmos and the ocular motility limitation and not correlated with the diplopia. For the enophthalmos of 2mm or greater, the mean fracture area was 3.55{\pm}1.25cm^2$ and the volume of the herniated orbital tissue was $1.74{\pm}0.97cm^3$; for less than 2mm enophthalmos, $1.43{\pm}0.99cm^3$ and $0.52{\pm}0.49cm^3$, respectively. The enophthalmos of 2mm can be expected with $2.92cm^2$ of the fracture area and $1.40cm^3$ of the herniated orbital tissue. In conclusion, the enophthalmos of 2mm or more, which is a frequent indication for surgery. It can be expected when area of fracture is $2.92cm^2$ or more, or the volume of herniated orbital tissue is $1.40cm^3$ or more. And the CT scan using linear measurements has an application in the assessment of patients with blowout fractures and provides useful information in the posttraumatic evaluation of orbital fractures.

Development of FACS-based Android Head for Emotional Expressions (감정표현을 위한 FACS 기반의 안드로이드 헤드의 개발)

  • Choi, Dongwoon;Lee, Duk-Yeon;Lee, Dong-Wook
    • Journal of Broadcast Engineering
    • /
    • v.25 no.4
    • /
    • pp.537-544
    • /
    • 2020
  • This paper proposes the creation of an android robot head based on the facial action coding system(FACS), and the generation of emotional expressions by FACS. The term android robot refers to robots with human-like appearance. These robots have artificial skin and muscles. To make the expression of emotions, the location and number of artificial muscles had to be determined. Therefore, it was necessary to anatomically analyze the motions of the human face by FACS. In FACS, expressions are composed of action units(AUs), which work as the basis of determining the location and number of artificial muscles in the robots. The android head developed in this study had servo motors and wires, which corresponded to 30 artificial muscles. Moreover, the android head was equipped with artificial skin in order to make the facial expressions. Spherical joints and springs were used to develop micro-eyeball structures, and the arrangement of the 30 servo motors was based on the efficient design of wire routing. The developed android head had 30-DOFs and could express 13 basic emotions. The recognition rate of these basic emotional expressions was evaluated at an exhibition by spectators.

Evaluation of the Fetal Dose during Prophylactic Placement of Internal Iliac Artery Balloon Occlusion Catheters in Placenta Accreta (유착태반환자의 예방적 내장골동맥 풍선카테터 설치술 시행 시 태아선량 평가)

  • Kim, Dong-Sik;Ahn, Sung-Min
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.313-321
    • /
    • 2016
  • Placenta accrete patients whose mother mortality rates are rather high due to massive bleeding during childbirth need to have Prophylactic placement of Internal Iliac Artery Balloon Occlusion Catheters procedure to reduce amount of blood loss and inoperative transfusion. Nevertheless, studies for mothers inevitably exposed to dose during PIIABOCs procedure have not been published many yet. Therefore, this study is to investigate exact information on radiation dose exposed to fetus during PIIABOCs procedure. Average effective dose of fetus per organ is 2.38~8.83 mGy, measured highest at beam center and followed by eyeball, stomach and bladder. The result showed that the longer fluoroscopy time is used, the closer beam center is and the thicker abdominal thickness is, the more effective dose on fetus is increasing. When using the collimator and protection shown to decrease the effective dose and when using higher the patient table shown to decrease the effective dose. It has been reported that the threshold of deterministic effect is about 100mGy. Deterministic effect was regarded as a factor that would influence on fetus exposed by medical radiation than stochastic effect. Consequently, it concluded that dose exposed on fetus in PIIABOCs procedure was approximately 10% of threshold of deterministic effect with effective dose of 0.49~18.27 mGy.

Association between the C.O.G and E.O.G for Dynamic Postural Control of the Left Turn Motion on the Balance Beam (평균대 좌측 턴 동작시 동적 자세 조절에 미치는 C.O.G와 E.O.G 관계)

  • So, Jae-Moo;Kim, Yoon-Ji;Kim, Jae-Jung
    • Korean Journal of Applied Biomechanics
    • /
    • v.19 no.1
    • /
    • pp.49-58
    • /
    • 2009
  • This study aims to analyze the association between the center of mass(C.O.G) and ocular movement(E.O.G) according to the success and failure in the left turn motion on the balance beam, targeting three female gymnasts. When successful, the left-right C.O.G was moved to the left, which was a rotational direction until such time as the body rotated $180^{\circ}$, whereas there appeared to be a greater movement during failure; thus, it was shown to affect the maintenance of dynamic postural control. In case of the subsequent left-right turning motion of E.O.G, this matches the previous theory that the eyeball moves against the direction of rotation of the body. However, there was a difference at the time of movement, and a clear difference emerged in the success and failure in this study. Also, in the E.O.G in the up-down direction, a movement during failure showed a pattern of down direction in most cases; thus, it is deemed to affect the failure. Therefore, the kinetic postural control and E.O.G are supposed to affect the success and failure in a landing, which is the most importantly evaluated movement on the balance beam, in mutual association.

Experimental infection of Philasterides dicentrarchi in Juvenile Olive Flounder, Paralichthys olivaceus (양식넙치에서 분리된 스쿠티카 섬모충 Philasterides dicentrarchi의 넙치 치어 인위감염)

  • Jin Chang-Nam;Kang Hyun-Sil;Lee Chang-Hoon;Lee Young-Don;Lee Je-Hee;Song Choon-Bok;Heo Moon-Soo
    • Journal of Aquaculture
    • /
    • v.19 no.3
    • /
    • pp.197-204
    • /
    • 2006
  • The pathogenicity and infection route of the Scuticociliate, Philasterdies dicentrarchi, were investigated with the 3 and 5 cm-group of juvenile flounders, Paralichthys olivaceus. The infection rates of 3 cm-group were 40% four days post infection (D.P.I.) and increased to be 90.1% 24 D.P.I., whereas those of 5 cm-group were 20% 8 D.P.I., 42% 16 D.P.I., and 81% 24 D.P.I. The results showed there were several infection routes to internal organs Olive flounder. The first route was started with the infection at the soft part of caudal fin and later reached at fin ray and muscle tissue; the second one was started from lips and mouth tissue of upper jaw and later the pathogen could be observed at either muscle tissue or eyeball and brain; the third one was begun at caudal fin and later the pathogen reached at brain tissu'e through spiral cord; the fourth one was started with the infections at abdominal cavity and anus. P. dicentrarchi infected to brain tissue was first observed 14 D.P.I in 3 cm-group and 20 D.P.I. in 5 cm-group of the juvenile flounder. This indicated that the brain infection of P. dicentrarchi might occur faster in small-sized flounder than large-sized one.

Evaluation of the Radiochromic Film Dosimetry for a Small Curved Interface (휘어진 경계에서의 좁은 영역에 대한 Radiochromic 필름 도시메트리 평가)

  • Kang, Sei-Kwon;Park, Soah;Hwang, Taejin;Cheong, Kwang-Ho;Han, Taejin;Kim, Haeyoung;Lee, Me-Yeon;Kim, Kyoung Ju;Bae, Hoonsik
    • Progress in Medical Physics
    • /
    • v.23 no.4
    • /
    • pp.234-238
    • /
    • 2012
  • A tumor on the eyelid is often treated using a high-energy electron beam, with a metallic eye shield inserted between the eyelid and the eyeball to preserve the patient's sight. Pretreatment quality assurance of the inner eyelid dose on the metallic shield requires a very small dosimetry tool. For enhanced accuracy, a flexible device fitting the curved interface between the eyelid and the shield is also required. The radiochromic film is the best candidate for this device. To measure the doses along the curved interface and small area, a 3-mm-wide strip of EBT2 film was inserted between the phantom eyelid and the shield. After irradiation with 6 MeV electron beams, the film was evaluated for the dose profile. An acrylic eye shield of the same size as the real eye shield was machined, and CT images free from metal artifacts were obtained. Monte Carlo simulation was performed on the CT images, taking into account eye shield material, such as tungsten, aluminum, and steel. The film-based interface dose distribution agreed with the MC calculation within 2.1%. In the small (millimeter scale) and curved region, radiochromic film dosimetry promises a satisfactory result with easy handling.

A useful additional medial subbrow approach for the treatment of medial orbital wall fracture with subciliary technique

  • Kim, Seung Min;Kim, Cheol Keun;Jo, Dong In;Lee, Myung Chul;Kim, Ji Nam;Choi, Hyun Gon;Shin, Dong Hyeok;Kim, Soon Heum
    • Archives of Craniofacial Surgery
    • /
    • v.20 no.2
    • /
    • pp.101-108
    • /
    • 2019
  • Background: To date, a variety of surgical approaches have been used to reconstruct the medial orbital wall fracture. Still however, there is still a controversy as to their applicability because of postoperative scars, injury of anatomical structures and limited visual fields. The purpose of this study was to introduce a useful additional medial subbrow approach for better reduction and securement more accurate implant pocket of medial orbital wall fracture with the subciliary technique. Methods: We had performed our technique for a total of 14 patients with medial orbital wall fracture at our medical institution between January 2016 and July 2017. All fractures were operated through subciliary technique combined with the additional medial subbrow approach. They underwent subciliary approach accompanied by medial wall dissection using a Louisville elevator through the slit incision of the medial subbrow procedure. This facilitated visualization of the medial wall fracture site and helped to ensure a more accurate pocket for implant insertion. Results: Postoperative outcomes showed sufficient coverage without displacement. Twelve cases of preoperative diplopia improved to two cases of postoperative diplopia. More than 2 mm enophthalmos was 14 cases preoperatively, improving to 0 case postoperatively. Without damage such as major vessels or extraocular muscles, enophthalmos was corrected and there was no restriction of eyeball motion. Conclusion: Our ancillary procedure was useful in dissecting the medial wall, and it was a safe method as to cause no significant complications in our clinical series. Also, there is an only nonvisible postoperative scar. Therefore, it is a recommendable surgical modality for medial orbital wall fracture.

Analysis of Binocular Abnormality by Eyeball Motion in Ametropia (비정시의 안구운동에 의한 양안시 이상 분석)

  • Seong, Jeong-Sub
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.3
    • /
    • pp.205-213
    • /
    • 2005
  • To evaluate the reliability of binocular vision measurements by phorometry. 90 students volunteered to participate in this study. 25 subjects were males, and 65 were females, they ranged in ages from 21 to 30 years. All subjects had normal ocular and systematic health, and all of them had at least 1.0 visual acuity with their best correction. At negative relative convergence(NRC) measurement in distance, the percentage of subjects is included in expected value(blur point/break point/recovery point) was 78%/61%/67%, divergence excess(DE) was 9%/31%/33%, and divergence insufficience(DI) was 13%/8%/9%, respectively. And positive relative convergence(PRC) measurement, includes expected value was 20%/46%/39%, convergence excess(CE) was 22%/14%/16%, and convergence insufficience(CI) was 35%/40%/45%. AC/A ratios of 42 subjects were normal. 38 were low, and the rest of them high. A low AC/A ratio is usually the result of a small vergence response in relation to accommodation. Negative relative convergence(NRC) at near, includes expected value was 26%/29%/44%, divergence excess(DE) was 61%/33%/24%, and divergence insufficience(DI) was 3%/38%/32%. And PRC at near, includes expected value was 33%/40%/31%, convergence excess(CE) was 61%/23%/42%, and convergence insufficience(CI) was 6%/37%/27%. For the near point of convergence(NPC) test, 58% of their subjects had a break of ${\leq}8cm$ with the accommodative target. In case of NRA(PRA) measurement, the expected value was 41%(33%). Accommodative insufficiency (AI) was 33%(43%), and accommodative excess(AE) was 26%(24%), respectively. AE was related to respectively low values of NRA. AI and CE are associated with high value of NRA, and the dysfunction of convergence excess combined with AE was related to a normal-high values of NRA. PRA in AI was related to a low value, wheres the dysfunction are associated with high values of PRA.

  • PDF