• Title/Summary/Keyword: Eye Dose

Search Result 162, Processing Time 0.022 seconds

Cytotec Induced Embryotoxicity in Developing Mus musculus

  • Naeem, Khadija;Ahmad, Naveed;Asmatullah, Asmatullah
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.23 no.10
    • /
    • pp.1282-1290
    • /
    • 2010
  • The study was carried out to assess the developmental abnormalities induced by Cytotec in mice during intrauterine life. Pregnant mice were exposed to a single dose of 0, 0.02, 0.04, 0.06, 0.08 and $0.1{\mu}g$/g BW on day 8 of gestation. Fetuses were recovered on day 18 of gestation. These fetuses were subjected to morphological and morphometric studies. Morphological studies showed abnormalities like anophthalmia, microophthalmia, micromelia and syndactyly. In addition to these, resorptions were also encountered in the higher dose groups. Morphometric analysis showed an overall reduction in body weight, crown rump length, brain and eye circumference, pinna and snout size, length of fore and hind limb and tail size with a significant difference (p<0.001) compared to controls. The outcomes of histological studies revealed some brain defects like hydrocephaly, enlarged third ventricle and undifferentiated ectoneural cells and abnormalities of the heart included right auricle thrombosis and degeneration of trabecular zone.

Development and Radiation Shield effects of Dose Reduction Fiber for Scatter ray in CT Exams (피폭선량저감 섬유의 개발과 CT 검사시 산란선 차폐 효과)

  • Kim, Sunghwan;Kim, Yong Jin;Kwak, Jong Suk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.4
    • /
    • pp.1871-1876
    • /
    • 2013
  • In this study, we developed and characterized the shielding properties of dose reduction fiber (DRF, Buffalo Co.) sheet during brain and chest CT examinations. The DRF sheet was composed of $1{\sim}500{\mu}m$ oxide Bismuth ($Bi_2O_3$) and 5 ~ 50 nm nano-barium sulfate ($BaSO_4$). Phantom and clinical studies were performed for characterization of the DRF shielding properties. In clinical study, we measured doses of eye, chest, abdomen and reproductive system of 60 patients in 3 hospitals during brain and chest CT examinations. We could determined the shielding effect of the DRF by comparing the doses when we used the DRF sheet or not. When we used the sheet during CT examination, the scattered dose were reduced about 20~50%. So, we suggest that the fiber should be used in radiological examinations for reducing patients doses.

Reduction of Radiation Dose to Eye Lens in Cerebral 3D Rotational Angiography Using Head Off-Centering by Table Height Adjustment: A Prospective Study

  • Jae-Chan Ryu;Jong-Tae Yoon;Byung Jun Kim;Mi Hyeon Kim;Eun Ji Moon;Pae Sun Suh;Yun Hwa Roh;Hye Hyeon Moon;Boseong Kwon;Deok Hee Lee;Yunsun Song
    • Korean Journal of Radiology
    • /
    • v.24 no.7
    • /
    • pp.681-689
    • /
    • 2023
  • Objective: Three-dimensional rotational angiography (3D-RA) is increasingly used for the evaluation of intracranial aneurysms (IAs); however, radiation exposure to the lens is a concern. We investigated the effect of head off-centering by adjusting table height on the lens dose during 3D-RA and its feasibility in patient examination. Materials and Methods: The effect of head off-centering during 3D-RA on the lens radiation dose at various table heights was investigated using a RANDO head phantom (Alderson Research Labs). We prospectively enrolled 20 patients (58.0 ± 9.4 years) with IAs who were scheduled to undergo bilateral 3D-RA. In all patients' 3D-RA, the lens dose-reduction protocol involving elevation of the examination table was applied to one internal carotid artery, and the conventional protocol was applied to the other. The lens dose was measured using photoluminescent glass dosimeters (GD-352M, AGC Techno Glass Co., LTD), and radiation dose metrics were compared between the two protocols. Image quality was quantitatively analyzed using source images for image noise, signal-to-noise ratio, and contrast-to-noise ratio. Additionally, three reviewers qualitatively assessed the image quality using a five-point Likert scale. Results: The phantom study showed that the lens dose was reduced by an average of 38% per 1 cm increase in table height. In the patient study, the dose-reduction protocol (elevating the table height by an average of 2.3 cm) led to an 83% reduction in the median dose from 4.65 mGy to 0.79 mGy (P < 0.001). There were no significant differences between dose-reduction and conventional protocols in the kerma area product (7.34 vs. 7.40 Gy·cm2, P = 0.892), air kerma (75.7 vs. 75.1 mGy, P = 0.872), and image quality. Conclusion: The lens radiation dose was significantly affected by table height adjustment during 3D-RA. Intentional head off-centering by elevation of the table is a simple and effective way to reduce the lens dose in clinical practice.

Study on the Measurement of Entrance Surface Dose to the Thyroid and Both Eyes in Dental Panoramic Radiography (치과 파노라마촬영에서의 갑상선과 양쪽 눈의 표면 선량 측정에 대한 연구)

  • Jung-Hoon Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.6
    • /
    • pp.733-740
    • /
    • 2024
  • Panoramic radiography is a technique that captures high-resolution images of the oral and dental areas of a patient, providing comprehensive information about the patient's entire dental condition in a single image. While panoramic radiography uses much less radiation compared to cone-beam CT (CBCT), the issue of patient radiation exposure cannot be overlooked. This study aimed to measure the entrance surface dose of radiation-sensitive tissues, such as the thyroid and eyes, during panoramic radiography, and to calculate the equivalent dose and effective dose from the measured absorbed dose to compare and analyze it with the dose limits. The experiment was conducted using the Rayscan α-OCL (Ray Co., Ltd. Gyeonggi-do, Korea) dental panoramic X-ray system. The phantom used was a head and neck phantom (Model PH-47, Kyoto Kagaku, Japan), which has an attenuation coefficient similar to that of human tissue. During panoramic radiography, the entrance surface dose was measured for radiation-sensitive tissues like the thyroid and lens. The entrance surface dose measured were 31.36 µGy for the thyroid, 25.70 µGy for the left lens, and 25.13 µGy for the right lens, respectively. To verify the differences in radiation doses for each site, a one-way ANOVA was performed, and a significant difference between groups was confirmed. A post-hoc test classified the left and right lenses into the same group, while the thyroid was classified into a different group. From the measured entrance surface dose, the equivalent doses for the left and right lenses were calculated to be 27.50 µSv and 27.13 µSv, respectively. The equivalent dose and effective dose for the thyroid were 31.36 µSv and 1.2544 µSv, respectively.

Application of Topical Rocuronium Bromide Dosing by Ocular Size in Four Species of Wild Birds

  • Haerin Rhim;Sunjun Jung;Namsoo Kim;Jae-Ik Han
    • Journal of Veterinary Science
    • /
    • v.24 no.4
    • /
    • pp.59.1-59.13
    • /
    • 2023
  • Background: Rocuronium bromide has been evaluated as a mydriatic agent in birds, but the species applied were limited and the dose and effect were variable. Objective: This study aims to evaluate the efficacy of topical rocuronium bromide as mydriatics in 4 species according to horizontal palpebral fissure length: Feral pigeon (Columba livia), Common kestrel (Falco tinnunculus), Northern boobook (Ninox japonica), and Eurasian eagle owl (Bubo bubo). Methods: A total of 32 birds (8 for each species) were included as pre-releasing examination. Rocuronium bromide was instilled in one randomly selected eye of each bird based on palpebral fissure length criteria (0.5 mg/50 µL for pigeons, 1 mg/100 µL for kestrels and boobook owls, and 2 mg/200 µL for eagle owls). The contralateral eye was used as control and treated with normal saline. After instillation of the drug, pupil diameter, pupillary light reflex, intraocular pressure, heart rate, and respiratory rate were evaluated at 10 min intervals up to 180 min and at 30 min intervals up to 360 min. Results: Statistically significant mydriasis was obtained in all birds (p < 0.001). However, in boobook and eagle owls, marked mydriasis persisted until 360 min. Side effects including corneal erosion and lower eyelid paralysis were common, which was observed in 26/32 birds. Blepharospasm was also noted during this study. No systemic adverse signs were observed. Conclusions: Rocuronium bromide could be a good mydriatics option for 4 species of birds, however, further studies are needed to find lowest effective dose to reduce drug-related side effects.

Research on Dose Reduction During Computed Tomography Scanning by CARE kV System and Bismuth (전산화 단층검사 시 Bismuth와 CARE kV System을 이용한 선량 저감화에 대한 연구)

  • Kwak, Yeong-Gon;Kim, Chong-Yeal;Jeong, Seong-Pyo
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.8
    • /
    • pp.233-242
    • /
    • 2014
  • The purpose of this study is to compare the reduction of the dose radioactivity by CARE kV with that of the Bismuth shielding. First, CT was performed with transparent materials, including a Bismuth shielder which is a well-known material for decreasing the dose of radiation. Moreover, we have estimated and compared the affects of the reduction of dose on eye lens, thyroid, breast and genitals. These steps aim to compare reactions with and without the application of the Rando phantom with PLD as well as with CARE kV or not. As a result, during the Brain angio scan, the dose of CARE kV set inspection test methods showed the least dose. Depending on whether we use CARE kV, which showed the effect of dose reduction by 63%. During the Carotid angio scan, the dose was increased by 13% by how to set CARE kV+Bismuth. During the Cardiac angio scan, which showed the effect of dose reduction by 31% by how to set CARE kV+Bismuth. During the Lower extremity angio scan, the dose was measured least by how to set up the whole Bismuth. Compared with CARE kV set of test methods, which showed the effect of dose reduction by 9%.

Evaluations of the Space Dose and Dose Reductions in Patients and Practitioners by Using the C-arm X-ray Tube Shielding Devices Developed in Our Laboratory

  • Kim, Jae Seok;Kim, Sung Ho;Lee, Bu Hyung;Kwon, Soo Il;Jung, Hai Jo;Hoe, Seong Wook;Son, Jin Hyun;Kang, Byeong Sam
    • Progress in Medical Physics
    • /
    • v.27 no.4
    • /
    • pp.241-249
    • /
    • 2016
  • The present study used a digital angiography x-ray device to measure the space dose and exposure dose of patients and practitioners using x-ray tube shielding devices developed in our laboratory. The intent of the study was to reduce the space dose within the test room, and to reduce the exposure dose of patients and practitioners. The patient and practitioner exposure doses were measured in five configurations in a human body model. The glass dosimeter was placed on the eye lenses, thyroid glands, left shoulder, right shoulder, and gonads. The beam was collimated at full size and at a 48% reduction for a comparative analysis of the measurements. The space dose was measured with an ion chamber at distances of 50 cm, 100 cm, and 150 cm from the x-ray tube under the following conditions: no shielding device; a shielding device made of 3-mm-thick lead (Pb) [Pb 3 mm shield], and a shielding device made of 3-mm-thick Pb (outside) and 3-mm-thick aluminum (Al) (inside) [Pb 3 mm+Al 3 mm shield]. The absorbed dose was the lowest when the 3-mm-thick Pb+3-mm-thick Al shield was used. For measurements made with collimated beams with a 48% reduction, the dose was the lowest at $154{\mu}Gy$ when the 3-mm-thick Pb+3-mm-thick Al shield was used, and was $9{\mu}Gy$ lower than the measurements made with no shielding device. If the space dose can be reduced by 20% in all situations where the C-arm is employed by using the x-ray tube shielding devices developed in our laboratory, this is expected to play an important role in reducing the annual exposure dose for patients, practitioners, and assistants.

A study of Brachytherapy for Intraocular Tumor (안구내 악성종양에 대한 저준위 방사선요법에 관한 연구)

  • Ji, Gwang-Su;Yu, Dae-Heon;Lee, Seong-Gu;Kim, Jae-Hyu;Ji, Yeong-Hun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.8 no.1
    • /
    • pp.19-27
    • /
    • 1996
  • I. Project Title A Study of Brachytherapy for intraocular tumor II. Objective and Importance of the project The eye enucleation or external-beam radiation therapy that has been commonly used for the treatment of intraocular tumor have demerits of visual loss and in deficiency of effective tumor dose. Recently, brachytherapy using the plaques containing radioisotope-now treatment method that decrease the demerits of the above mentioned treatment methods and increase the treatment effect-is introduced and performed in the countries, Our purpose of this research is to design suitable shape of plaque for the ophthalmic brachytherapy, and to measure absorbed doses of Ir-192 ophthalmic plaque and thereby calculate the exact radiation dose of tumor and it's adjacent normal tissue. III. Scope and Contents of the project In order to brachytherapy for intraocular tumor, 1. to determine the eye model and selected suitable radioisotope 2. to design the suitable shape of plaque 3. to measure transmission factor and dose distribution for custom made plaques 4. to compare with the these data and results of computer dose calculation models IV. Results and Proposal for Applications The result were as followed. 1. Eye model was determined as a 25mm diameter sphere, Ir-192 was considered the most appropriate as radioisotope for brachytherapy, because of the size, half, energy and availability. 2. Considering the biological response with human tissue and protection of exposed dose, we made the plaques with gold, of which size were 15mm, 17mm and 20mm in diameter, and 1.5mm in thickness. 3. Transmission factor of plaques are all 0.71 with TLD and film dosimetry at the surface of plaques and 0.45, 0.49 at 1.5mm distance of surface, respectively. 4. As compared the measured data for the plaque with Ir-192 seeds to results of computer dose calculation model by Gary Luxton et al. and CAP-PLAN (Radiation Treatment Planning System), absorbed doses are within ${\pm}10\%$ and distance deviations are within 0.4mm Maximum error is $-11.3\%$ and 0.8mm, respectively. As a result of it, we can treat the intraocular tumor more effectively by using custom made gold plaque and Ir-192 seeds.

  • PDF

A Study of Sterilization Effect of Long-wavelength UVA-LED Irradiation on Bacteria Causing Eye Diseases (장파장의 자외선 LED 광원을 이용한 안질환 세균의 살균효과)

  • Lee, Cheol-Woo;Jeong, Kyeong-In;Hwang, Kwang-Ha;Lee, Seok-Ju;Yoo, Geun-Chang
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.1
    • /
    • pp.99-105
    • /
    • 2012
  • Purpose: The purpose of this study is to demonstrate inactivation effect of UVA-LED ultraviolet radiation upon Pseudomonas aeruginosa and Staphylococcus aureus which are the major bacteria causing eye diseases. Methods: The small sterilization device was made using UVA-LED of 400 nm. After Pseudomonas aeruginosa was diluted to $10^{-7}$ and Staphylococcus aureus to $10^{-5}$ and diluted solutions were put onto each liquid medium. They were irradiated by 400 nm of UVA for different amount of time; 15 min, 30 min, 60 min, 120 min, 240 min, 360 min and 480 min each. Results: The data from sterilization test was solved to regression line equation and the target log inactivation was obtained. The 3 log inactivation UV irradiation value of Pseudomonas aeruginosa was 54,847 UV dose ($mJ/cm^2$) and irradiation time was 135.42 min while the 3 log inactivation of Staphylococcus aureus was 39,066 UV dose ($mJ/cm^2$) and irradiation time was 98.72 min. Conclusions: The inactivation effect of sterilization method using 400 nm of UVA-LED upon Pseudomonas aeruginosa and Staphylococcus aureus has been verified and it is considered as a useful method in inactivating the contact lenses.

Effect of Reducing Scattering Radiation Exposure of Medical Staffs When Additional Shielding is Used in Interventional Radiology (중재적 방사선시술에서 부가 차폐체 사용 시 종사자의 산란선 피폭 감소효과)

  • Kim, Min-Jun;Baek, Kang-Nam;Kim, Sungchul
    • Journal of radiological science and technology
    • /
    • v.44 no.6
    • /
    • pp.629-633
    • /
    • 2021
  • This article is designed to look into the radiation exposure dose to each body part and the shielding effect for workers using an additional shielding to reduce their radiation exposured by scattering radiation which is generated in a space between the operating table and lead curtain during interventional radiology(IR) procedures. After placing a human phantom on the table of SIEMENS' angiography machine, the following measurements were taken, depending on the presence of an additional shield of lead equivalent of 0.25 mmPb, manufactured for this purpose: dose to gonad, dose to an area where the personal dosimeter is placed, and dose to an area of eye lens is located. An ion chamber(chamber volume 1,800 cc) was utilized to measure scattering radiation. The two imaging tests were carried out as follows: fluoroscopy of the abdomen (66 kV, 100 mA, 60 seconds) and of the head (70 kV, 65 mA, 60 seconds); and digital subtraction angiography(DSA) of the abdomen (67 kV, 264 mA, 20 seconds) and of the head (79 kV, 300 mA, 20 seconds). In all the experiments, the shielding efficiency of the gonad position was the largest at 59.8%. In case an additional shielding was used as protection against scattering radiation that came through the operating table and the lead curtain during an IR, the radiation shielding efficiency was estimated to be up to 59.8%, leading to a conclusion that its presence may effectively reduce the radiation exposure dose of medical staffs.