• Title/Summary/Keyword: Eye Dose

Search Result 162, Processing Time 0.03 seconds

Combined Effect of Irradiation and Ageing Condition on Physicochemical and Microbial Quality of Hanwoo Eye of Round

  • Yim, Dong-Gyun;Jo, Cheorun;Kim, Hyun-Joo;Cha, Ju-Su;Kim, Hyun Cheol;Nam, Ki-Chang
    • Food Science of Animal Resources
    • /
    • v.35 no.3
    • /
    • pp.406-412
    • /
    • 2015
  • The combined effects of electron-beam irradiation and ageing of beef were examined. The irradiated samples at dose of 0 or 2 kGy were kept and analyzed for the microbial growth, shear values, meat color, and nucleotide-related flavor compounds at different ageing temperatures (2, 10, or 25℃) for 8 d. The irradiation effect on inactivation of foodborne pathogens was also investigated. The population of Listeria monocytogenes and E. coli O157:H7 inoculated in beef samples decreased in proportion to the irradiation dose, showing D10 values of 0.66 and 0.65 kGy respectively. The irradiated beef eye of round had lower number of total aerobic bacteria (TAB) than nonirradiated one during the storage, but the TAB increased with higher ageing temperature (p<0.05). Especially, TAB increased sharply in non-irradiated samples aged at 25℃ after 4 d (p<0.05). With increasing ageing temperature and ageing time, shear force values decreased (p<0.05). The color a* values of the irradiated beef were lower than those of the non-irradiated throughout the ageing period (p<0.05). As ageing time and temperature increased, the amounts of inosine monophosphate decreased and the hypoxanthine increased (p<0.05). Relatively high ageing temperature could be used at irradiated beef eye of round to shorten the ageing time.

Lens Dose Reduction Methods and Image Quality in Orbital Computed Tomography Scan (안와 전산화단층촬영검사 시 수정체 선량감소 방법과 영상 평가)

  • Moon, Se-Young;Hong, Sang-Woo;Seo, Ji-Sook;Kim, Yeong-Beom;Kwak, Wan-Sin;Lee, Seong-Yeong;Kim, Jung-Soo
    • Journal of radiological science and technology
    • /
    • v.43 no.5
    • /
    • pp.343-351
    • /
    • 2020
  • This study analyzed dose reduction and quality of images through dose reduction tools and shielding board to protect sensitive eye lens in radiation during orbit CT examinations for clinical data use. During CT scans of the phantom, surface dose (CT scanner dosimetry phantom, ion chamber-3 times) and quality of image (radiosurgery head phantom, visual assessment-2 times, HU standard deviation) were evaluated using X-care which is dose reduction tools and bismuth shielding board. The results of experiments of eight conditions showed a relatively reduced dose in all other conditions compared to when no conditions were set. In particular, the area corresponding to the ophthalmic part reduced the surface dose by up to 45.7 %. The visual evaluation of images by specialists and the quality evaluation of images analyzed by HU standard deviation were clinically closest to the use of X-care and shielding board (1 cm in height). Therefore, it is believed that the use of shielding board in a suitable location with dose reduction tools while investigating the optimal radiation dose will reduce the exposure dose of sensitive lens at radiation while maintaining the quality of the images with high diagnostic value.

Test of a Multilayer Dose-Verification Gaseous Detector with Raster-Scan-Mode Proton Beams

  • Lee, Kyong Sei;Ahn, Sung Hwan;Han, Youngyih;Hong, Byungsik;Kim, Sang Yeol;Park, Sung Keun
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.4 no.5
    • /
    • pp.297-304
    • /
    • 2015
  • A multilayer gaseous detector has been developed for fast dose-verification measurements of raster-scan-mode therapeutic beams in particle therapy. The detector, which was constructed with eight thin parallel-plate ionization chambers (PPICs) and polymethyl methacrylate (PMMA) absorber plates, is closely tissue-equivalent in a beam's eye view. The gas-electron signals, collected on the strips and pad arrays of each PPIC, were amplified and processed with a continuous charge.integration mode. The detector was tested with 190-MeV raster-scan-mode beams that were provided by the Proton Therapy Facility at Samsung Medical Center, Seoul, South Korea. The detector responses of the PPICs for a 190-MeV raster-scan-mode proton beam agreed well with the dose data, measured using a 2D ionization chamber array (Octavius model, PTW). Furthermore, in this study it was confirmed that the detector simultaneously tracked the doses induced at the PPICs by the fast-oscillating beam, with a scanning speed of 2 m s-1. Thus, it is anticipated that the present detector, composed of thin PPICs and operating in charge.integration mode, will allow medical scientists to perform reliable fast dose-verification measurements for typical dynamic mode therapeutic beams.

The evaluation of lens absorbed dose according to the Optimold for whole brain radiation therapy (전뇌 방사선치료 시 Optimold에 따른 수정체의 흡수선량 평가)

  • Yang, Yong Mo;Park, Byoung Suk;Ahn, Jong Ho;Song, Ki Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.77-81
    • /
    • 2014
  • Purpose : In the current whole brain Radiation Therapy, Optimold was used to immobilize the head. However, skin dose was increased about 22% due to the scattering radiation by the Optimold. Since the minimum dose causing cataracts was 2 Gy, it could be seen that the effects were large especially on the lens. Therefore, in the whole brain Radiation Therapy, it was to compare and to evaluate the lens absorbed dose according to the presence of Optimold in the eyeball part. Materials and Methods : In order to compare and to evaluate the lens absorbed dose according to the presence of Optimold in the eyeball part, the Optimold mask was made ??up to 5mm bolus on the part of the eye lens in the human model phantom (Anderson Rando Phantom, USA). In the practice treatment, to measure the lens dose, the simulation therapy was processed by placing the GafChromic EBT3 film under bolus, and after the treatment plan was set up through the treatment planning system (Pinnacle, PHILIPS, USA), the treatments were measured repeatedly three times in the same way. After removing the Optimold mask in the eyeball part, it was measured in the same way as above. After scanning the film and measuring the dose by using the Digital Flatbed Scanner (Expression 10000XL, EPSON, USA), the doses were compared and evaluated according to the presence of Optimold mask in the eyeball part. Results : When there was the Optimold mask in the eyeball part, it was measured at $10.2cGy{\pm}1.5$ in the simulation therapy, and at $24.8cGy{\pm}2.7$ in the treatment, and when the Optimold mask was removed in the eye part, it was measured at $12.9cGy{\pm}2.2$ in the simulation therapy, and at $17.6cGy{\pm}1.5$ in the treatment. Conclusion : In case of removing the Optimold mask in the eyeball part, the dose was increased approximately 3 cGy in the simulation therapy and was reduced approximately 7 cGy in the treatment in comparison to the case that the Optimold mask was not removed. During the whole treatment, since the lens absorbed dose was reduced about 27%, the chance to cause cataracts and side effects was considered to be reduced due to decrease of the absorbed dose to the eye lens which had the high sensitivity on the radiation.

Pharmacokinetics of Uridine Following Ocular, Oral and Intravenous Administration in Rabbits

  • Kim, Eunyoung;Kang, Wonku
    • Biomolecules & Therapeutics
    • /
    • v.21 no.2
    • /
    • pp.170-172
    • /
    • 2013
  • The pyrimidine nucleoside uridine has recently been reported to have a protective effect on cultured human corneal epithelial cells, in an animal model of dry eye and in patients. In this study, we investigate the pharmacokinetic profile of uridine in rabbits, following topical ocular (8 mg/eye), oral (450 mg/kg) and intravenous (100 mg/kg) administration. Blood and urine samples were serially taken, and uridine was measured by high-performance liquid chromatography-tandem mass spectrometry. No symptoms were noted in the animals after uridine treatment. Uridine was not detected in either plasma or urine after topical ocular administration, indicating no systemic exposure to uridine with this treatment route. Following a single intravenous dose, the plasma concentration of uridine showed a bi-exponential decay, with a rapid decline over 10 min, followed by a slow decay with a terminal half-life of $0.36{\pm}0.05$ h. Clearance and volume of distribution were $1.8{\pm}0.6$ L/h/kg and $0.58{\pm}0.32$ L/kg, respectively. The area under the plasma concentration-time curves (AUC) was $59.7{\pm}18.2{\mu}g{\cdot}hr/ml$, and urinary excretion up to 12 hr was ~7.7% of the dose. Plasma uridine reached a peak of $25.8{\pm}4.1{\mu}g/ml$ at $2.3{\pm}0.8$ hr after oral administration. The AUC was $79.0{\pm}13.9{\mu}g{\cdot}hr/ml$, representing ~29.4% of absolute bioavailability. About 1% of the oral dose was excreted in the urine. These results should prove useful in the design of future clinical and nonclinical studies conducted with uridine.

Radiation exposure to the eyes and thyroid during C-arm fluoroscopy-guided cervical epidural injections is far below the safety limit

  • Choi, Eun Joo;Go, Gwangcheol;Han, Woong Ki;Lee, Pyung-Bok
    • The Korean Journal of Pain
    • /
    • v.33 no.1
    • /
    • pp.73-80
    • /
    • 2020
  • Background: The aim of this study was to evaluate radiation exposure to the eye and thyroid in pain physicians during the fluoroscopy-guided cervical epidural block (CEB). Methods: Two pain physicians (a fellow and a professor) who regularly performed C-arm fluoroscopy-guided CEBs were included. Seven dosimeters were used to measure radiation exposure, five of which were placed on the physician (forehead, inside and outside of the thyroid protector, and inside and outside of the lead apron) and two were used as controls. Patient age, sex, height, and weight were noted, as were radiation exposure time, absorbed radiation dose, and distance from the X-ray field center to the physician. Results: One hundred CEB procedures using C-arm fluoroscopy were performed on comparable patients. Only the distance from the X-ray field center to the physician was significantly different between the two physicians (fellow: 37.5 ± 2.1 cm, professor: 41.2 ± 3.6 cm, P = 0.03). The use of lead-based protection effectively decreased the absorbed radiation dose by up to 35%. Conclusions: Although there was no difference in radiation exposure between the professor and the fellow, there was a difference in the distance from the X-ray field during the CEBs. Further, radiation exposure can be minimized if proper protection (thyroid protector, leaded apron, and eyewear) is used, even if the distance between the X-ray beam and the pain physician is small. Damage from frequent, low-dose radiation exposure is not yet fully understood. Therefore, safety measures, including lead-based protection, should always be enforced.

A Study of Radiation Doses to the Patient and Medical Team at Embolization Procedures

  • Castilho, Alvaro Vilas Boas;Szjenfeld, Denis;Nalli, Darcio;Fornazari, Vinicius;Moreira, Antonio Carlos;Medeiros, Regina Bitelli
    • Journal of Radiation Protection and Research
    • /
    • v.44 no.3
    • /
    • pp.110-117
    • /
    • 2019
  • Background: This study aimed to estimate occupational doses and patient peak skin doses (PSDs) during interventional radiology procedures. Materials and Methods: We examined data from brain embolization (n = 30), hepatic chemoembolization (n = 50), and uterine embolization (n = 12). The PSDs were measured using radiochromic film around the patient's head (group 1) or abdominal/pelvic region (group 2). Acquisition technical data and kerma-area products (KAP) were also recorded. Occupational doses were measured using $Instadose^{TM}$ dosimeters near the left eye region (LER), chest, and left ankle. Results and Discussion: The third quartile (median) KAP values were $408.1(235.3)Gy{\cdot}cm^2$ for group 1 and $584.4(449.4)Gy{\cdot}cm^2$ for group 2. The average PSDs were greatest during vascular procedures, reaching 1,004.4 (786.4) mGy, and the highest PSD was 2,352.6 mGy (during hepatic chemoembolization). The third quartile (median) occupational doses were 0.35 (0.21) mSv at the LER, 0.25 (0.15) mSv at the chest, and 1.47 (0.64) mSv at the left ankle. Occupational doses at the LER were higher than at the chest, which highlights the importance of protective glasses and suspended shields. The occupational doses at the ankle region were also high, which highlights the importance of using a lead-lined curtain attached to the table. Conclusion: The results indicate that physicians can reach, for eye region, the weekly occupational dose limit after around 15 procedures, even when using proper protection. The average PSD values were below the threshold for tissue reactions, although the complexity of these procedures emphasises the importance of considering related risks.

Ocular Sparganosis: The First Report of Spirometra ranarum in Thailand

  • Saksirisampant, Wilai;Eamudomkarn, Chatanun;Jeon, Hyeong-Kyu;Eom, Keeseon S.;Assavapongpaiboon, Buravej;Sintuwong, Sunisa;Tulvatana, Wasee
    • Parasites, Hosts and Diseases
    • /
    • v.58 no.5
    • /
    • pp.577-581
    • /
    • 2020
  • A 22-year-old Thai man from the Northeast region presented with acute eye swelling, itching, and discharge on his left eye. He was suspected of having gnathostomiasis and treated with albendazole and prednisolone for 3 weeks. Nine months later, he was treated with high-dose oral prednisolone for the preliminary and differential diagnoses with thyroid-associated orbitopathy and lymphoma. He had been administered prednisolone intermittently over a few years. Then he developed a painless movable mass at the left upper eyelid and recurrent pseudotumor oculi was suspected. The surgical removal of the mass was performed. A white pseudosegmented worm revealed a definite diagnosis of ocular sparganosis by a plerocercoid larva. Molecular diagnosis of the causative species was made based on the mitochondrial cytochrome c oxidase subunit 1 (cox1) gene. Proper technique of extraction and amplification of short fragments DNA from formalin-fixed paraffin-embedded tissue successfully identified parasite species. The result from the sequencing of the PCR-amplified cox1 fragments in this study showed 99.0% sequence homology to Spirometra ranarum. This is the first report of S. ranarum in Thailand.

Pronephros Induction by Combined-dose of Activin A and IGF-1, and High-dose Effect of IGF-1 in Xenopus Animal Cap Assay (Xenopus 동물극의 분리배양에서 Activin A와 IGF-1의 복합처리에 의한 전신의 분화와 IGF-I 고농도의 효과)

  • 정선우;진정효;윤춘식
    • Journal of Life Science
    • /
    • v.8 no.5
    • /
    • pp.479-485
    • /
    • 1998
  • The induction of nephric duct from Xenopus presumptive ectoderm(animal cap) was studied and the high-dose ef-fect of IGF-1 was investigated. Activin A induce various organs from cultured animal cap explants and the effects are time and dose-dependent. On the induction of nephric duct, the combined-dose of activin A and retinoic acid was very efficient method in reference study. In present study, we used IGF-1 as well as activin A as a combined growth factor. The concentration ranges of growth factors were activin A l00ng/ml an IGF-1 0-500ng/m1. Explants were cultured in combined solution for 3days to the normal embryo arrives at st. 43. In general, when the explant was cultured in high concentration(l00ng/ml) of activin A, it was destroyed, however, nephric duct and other tis-sues were differentiated by adding IGF-1. In addition, eye induction by adding IGF-1 500ng/ml to activin A 1- 100 ng/ml solution was studied. The low concentration of activin A(1ng/ml) have blood-like cell inducing effect and the explant was balloon-shaped, however, the high dose combination with IGF-1 extended the range of eye inductive concentration of activin A.

  • PDF

A Study on Radiation Dose and Image Quality according to CT Table Height in Brain CT (두부 CT 검사 시 테이블 높이에 따른 선량과 화질에 관한 연구)

  • Ki-Won Kim;Joo-Young Oh;Jung-Whan Min;Sang-Sun Lee;Young-Bong Lee;Kyung-Hwan Lim;Yun Yi
    • Journal of radiological science and technology
    • /
    • v.46 no.2
    • /
    • pp.99-106
    • /
    • 2023
  • The height of the table should be considered important during computed tomography (CT) examination, but according to previous studies, not all radiology technologists set the table at the patient's center at the examination, which affects the exposure dose and image quality received by the patient. Therefore, this study intends to study the image quality exposure dose according to the height of the table to realize the optimal image quality and dose during the brain CT scan. The head phantom images were acquired using Philips Brilliance iCT 256. When the image was acquired, the table height was adjusted to 815, 865, 915, 965, 1015, and 1030 mm, respectively, and each scan was performed 3 times for each height. For the exposure dose measurement, optically stimulated luminescence dosimeter (OSLD) was attached to the front, side, eye, and thyroid gland of the head phantom. In the signal to noise ratio (SNR) measurement result, The SNR values for each table height were all lower than 915 mm. As a result of exposure dose, the exposure dose on each area increased as the table height decreased. The height of the table has a close relationship with the patient's radiation exposure dose in the CT scan.