• Title/Summary/Keyword: Eye Dose

Search Result 162, Processing Time 0.025 seconds

Semen Quality of the Black Bengal Bucks Used at Commercial Artificial Insemination

  • Dhar, Ajoy Chandra;Talukder, Anup Kumar;Rahman, Mohammad Bozlur;Al-Mamun, Abdullah;Shamsuddin, Mohammed
    • Journal of Embryo Transfer
    • /
    • v.25 no.4
    • /
    • pp.237-245
    • /
    • 2010
  • Only an optimum number of viable spermatozoa in a frozen-thawed insemination dose can ensure conception at artificial insemination (AI). We report here the percentages of normal, abnormal and viable spermatozoa present in the frozen-thawed semen of 20 Black Bengal bucks used for commercial AI. Bucks in this experiment were of 19.3~46.1 months old and 25~42 kg body weight. Four semen straws (0.25 ml) from each buck were collected for evaluation of their kinetic parameters. Scrotal circumference was measured by using a scrotal tape, sperm motility was estimated on eye estimation and sperm concentration was determined by using a haemocytometer. Sperm morphology was studied in paraformaldehyde fixed spermatozoa under differential interference contrast (DIC) microscope. To determine the proportion of live (plasma membrane intact) spermatozoa, semen was stained with SYBR-14 and propidium iodide and examined under fluorescent microscope. Scrotal circumference, post-thaw sperm motility, sperm concentration per insemination dose and proportion of normal spermatozoa were $21.5{\pm}0.7\;cm$, $43.5 {\pm}5.4%$, $83.5{\pm}6.7$ million and $88.3{\pm}4.1%$, respectively. The percentages of spermatozoa with head shape and acrosome abnormalities were lower ($2.7{\pm}1.1$ and $1.4{\pm}1.3$, respectively), whereas higher percentages of abnormalities ($7.0{\pm}1.8$) were observed in mid piece and tail portion. The proportion of live spermatozoa was $28.5{\pm}5.4$. It is concluded that although a good number of morphologically normal spermatozoa are present in the insemination dose, the proportion of live spermatozoa is low, which warrants further improvements of buck semen freezing procedures to ensure good quality at AI.

A Repeated-dose 28-Day Oral Toxicity Test of Aconitum jaluense Extract in Sprague-Dawley Rats (초오 추출물의 Sprague-Dawley 랫드를 이용한 28일 반복 경구투여독성시험)

  • Lee, Jong Suk;Lee, Ji Sun;Park, Yeong-Chul;Choi, Sun Mi;Lee, Sanghun
    • YAKHAK HOEJI
    • /
    • v.58 no.1
    • /
    • pp.62-70
    • /
    • 2014
  • A 28-day repeated-dose oral toxicity test was performed to determine the no-observed-effect level (NOEL) and establish an optimum dose of the highly toxic Aconiti Ciliare Tuber (ACT) used as a folk remedy. Repeated oral doses of 1,250, 2,500, and 5,000 mg/kg/day of the hot water extract of ACT were administered to five male and five female Sprague-Dawley rats in each group for 4 weeks. The indicators for toxicity included results of examination of common symptoms and changes in weight and feed intake, eye test, urinalysis, hematological and serum biochemical analyses, and post-mortem weight measurement of organs, and visual inspections. All animals survived at the end of the experiment; in addition, we observed no specific test substance-mediated symptoms. We observed no test substance-mediated changes in body weight and feed intake. We observed statistically significant changes in male OB and pH levels (p<0.05). Further, the biochemical test showed statistically significant changes in the IP value of male rats and $CL^-$valueoffemalerats (p<0.05). However, all changes were within historical data. The post-mortem examinations showed no test substance-mediated changes. Moreover, statistically significant changes under the test conditions were confirmed to have been caused by factors other than the test substance. Thus, the maximum NOEL of ACT extract in rats was estimated to be 5,000 mg/kg/day.

A Study on the Shielding of Orbit by 3D Printed Filament in Brain CT (Brain CT검사 시 3D프린터 필라멘트에 따른 수정체 차폐 연구)

  • Choi, Woo Jeon;Kim, Dong Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.101-108
    • /
    • 2021
  • The CT can accurately present the anatomical structure of an organ in the human body, and the resolution of the image is excellent. On Brain CT examination, the radiation sensitivity of the orbit is high and it is subject to many exposure effects. To reduce exposure dose of lens, this study compares change of exposure dose and shielding rate about non-shielding and shielding in a way of using two shielding materials, bismuth and tungsten. In this study, we used bismuth and tungsten filament as shielding materials made by 3D printing to measure the exposure dose according to the materials thickness and each of slices. To compare each shielding rate, 1 mm to 5 mm of two materials was measured with the head phantom fixed and the Magicmax universal dosimeter placed on the eye when the shielding material is not placed, and the shielding material is placed on it. In the 1 mm thick filament, the bismuth filament showed 26.8% and the tungsten filament showed 43.1% shielding rate. Therefore, tungsten presents much greater shielding effect than bismuth.

Dose Characteristics of Stereotactic Radiosurgery in High Energy Linear Accelerator Proton Beam (고에너지 선형가속기에 의한 입체방사선수술의 선량특성)

  • Choi, Tae-Jin;Kim, Ok-Bae
    • Radiation Oncology Journal
    • /
    • v.10 no.2
    • /
    • pp.137-145
    • /
    • 1992
  • Three-dimensional dose calculations based on CT images are fundamental to stereotactic radiosurgery for small intracranial tumor. In our stereotactic radiosurgery program, irradiations have been performed using the 6 MV photon beam of linear accelerator after stereotactic CT investigations of the target center through the beam's-eye view and the coordinates of BRW frame converted to that of radiosurgery. Also we can describe the tumor diameter and the shape in three dimensional configuration. Non-coplanar irradiation technique was developed that it consists of a combination of a moving field with a gantry angle of $140^{\circ}$, and a horizontal couch angle of $200^{\circ}C$ around the isocenter. In this radiosurgery technique, we provide the patient head setup in the base-ring holder and rotate around body axis. The total gantry moving range shows angle of 2520 degrees via two different types of gantry movement in a plane perpendicular to the axis of patient. The 3-D isodose curves overlapped to the tumor contours in screen and analytic dose profiles in calculation area were provided to calculate the thickness of $80\%$ of tumor center dose to $20\%$ of that. Furtheremore we provided the 3-D dose profiles in entire calculation plane. In this experiments, measured isodose curves in phantom irradiation have shown very similiar to that of computer generations.

  • PDF

A Method for Estimating the Lung Clinical Target Volume DVH from IMRT with and without Respiratory Gating

  • J. H. Kung;P. Zygmanski;Park, N.;G. T. Y. Chen
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.53-60
    • /
    • 2002
  • Motion of lung tumors from respiration has been reported in the literature to be as large as of 1-2 cm. This motion requires an additional margin between the Clinical Target Volume (CTV) and the Planning Target Volume (PTV). While such a margin is necessary, it may not be sufficient to ensure proper delivery of Intensity Modulated Radiotherapy (IMRT) to the CTV during the simultaneous movement of the DMLC. Gated treatment has been proposed to improve normal tissues sparing as well as to ensure accurate dose coverage of the tumor volume. The following questions have not been addressed in the literature: a) what is the dose error to a target volume without gated IMRT treatment\ulcorner b) what is an acceptable gating window for such treatment. In this study, we address these questions by proposing a novel technique for calculating the 3D dose error that would result if a lung IMRT plan were delivered without gating. The method is also generalized for gated treatment with an arbitrary triggering window. IMRT plans for three patients with lung tumor were studied. The treatment plans were generated with HELIOS for delivery with 6 MV on a CL2100 Varian linear accelerator with a 26 pair MLC. A CTV to PTV margin of 1 cm was used. An IMRT planning system searches for an optimized fluence map ${\Phi}$ (x,y) for each port, which is then converted into a dynamic MLC file (DMLC). The DMLC file contains information about MLC subfield shapes and the fractional Monitor Units (MUs) to be delivered for each subfield. With a lung tumor, a CTV that executes a quasi periodic motion z(t) does not receive ${\Phi}$ (x,y), but rather an Effective Incident Fluence EIF(x,y). We numerically evaluate the EIF(x,y) from a given DMLC file by a coordinate transformation to the Target's Eye View (TEV). In the TEV coordinate system, the CTV itself is stationary, and the MLC is seen to execute a motion -z(t) that is superimposed on the DMLC motion. The resulting EIF(x,y)is inputted back into the dose calculation engine to estimate the 3D dose to a moving CTV. In this study, we model respiratory motion as a sinusoidal function with an amplitude of 10 mm in the superior-inferior direction, a period of 5 seconds, and an initial phase of zero.

  • PDF

Studies on Toxic Components of Auricularia polytricha (털목이버섯의 독성(毒性)에 관한 연구(硏究))

  • Kim, Ha-Won
    • Korean Journal of Pharmacognosy
    • /
    • v.16 no.4
    • /
    • pp.221-226
    • /
    • 1985
  • To screen biologically active components of the higher fungi of Korea, the dried carpophores of Auricularia polytricha were extracted with water. The extract was examined for acute toxicity in ICR mice. A low molecular weight toxin of this fungus was purified by acetone precipitation followed by cellulose, silica gel and LH-20 Sephadex column chromatography. Major symptoms of this toxin were eye extrusion, hair erection, trembling of head, paralysis, rapid running or moving before death and depression of respiration. The median lethal doses of the total extract were 1.25 g/kg and 4.18 g/kg by i.p. and p.o. administrations, respectively. The amounts of one mouse lethal unit (MLU) of the total extract and final fraction that killed a 20-g mouse within 30 minutes were 28.5 mg/mouse and 12 mg/mouse, respectively.

  • PDF

The Safety Evaluation of a Potent Antioxidant, Fructose 1,6-diphosphate(FDP), for the Skin Application (항산화력이 우수한 Fructose 1,6-diphosphate(FDP)를 피부적용제로 응용하기 위한 안전성 평가)

  • 김배환;이병석;정경미;안수미;안수선;심영철
    • Toxicological Research
    • /
    • v.18 no.3
    • /
    • pp.267-273
    • /
    • 2002
  • Fructose 1,6-diphosphate(FDP), a glycolytic metabolite, is reported to ameliorate inflammation and inhibit the nitric oxide production in murine macrophages stimulated with endotoxin. It is also reported that FDP has cytoprotective effects against hypoxia or ischemia/reperfusion injury in brain and heart, and may play a protective role in ultraviolet B (UVB, 280~320 nm)-injured keratinocyte by attenuating prostaglandin (PG)-E$_2$production and cyclooxygenase (COX)-2 expression, which are possibly through blocking the intracellular reactive oxygen species (ROS) accumulation. Therefore FDP is considered to act as a potent antioxidant especially in the skin. We conducted the several safety tests (single-dose toxicity, primary skin irritation test, eye irritation test, skin sensitization test, phototoxicity test, photosenitization test and human patch test) to see if FDP is safe in case used for the skin application. Our data obtained hitherto suggest that FDP is very safe if applied to the skin.

A Study on Sterilization of Medical Products by Gamma-irradiation. (Gamma선 조사에 의한 의류제품의 멸균연구)

  • 정해원;정문식;문석형
    • Journal of Environmental Health Sciences
    • /
    • v.5 no.1
    • /
    • pp.1-9
    • /
    • 1978
  • Biological safety, physico-chemical and microbiological experiments were carried out in order to study the possibility of radiation sterilization on medical products, such as polyethylene and polystyrene bottles, gauze sponges and surgical silk suture. Results are as follows: 1. Biological test on plastic samples as to acute systemic toxicity, eye irritation, skin irritation, pyrogen, haemolysis showed satisfactory results. But physico-chemically, the oxidizable matter, nonvolatile residues, residue on ignition seemed to be increased slightly in irradiated samples, though the experimental results were within the range of U.S.P. 19, N.F. and K.P. III. 2. After irradiation, both plastic and gauze sponges showed considerable decrease in pH. 3. Most medical products were sterilized by 1.5 Mard. For the sterilization of the suigical silk suture, 4.5 Mrad is required dul to its radiation resistant micro-organisms. 4. Biologically, total dose of 2.5 Mrad was safe enough to sterilize the medical products, and physico-chemically the results are acceptable according to U.S.P. 19 and K.P. III. However, better results may be expected when the quality of material and additives are improved.

  • PDF

Teratogenic and Embryotoxic Effects of Clomiphene Citrate in Developing Mice

  • Ara, Chaman;Asmatullah, Asmatullah
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.24 no.8
    • /
    • pp.1053-1059
    • /
    • 2011
  • The objective of this study was to assess the teratogenic and embryotoxic effects of clomiphene citrate in mice. The pregnant mice were administered a single dose of clomiphene citrate at different concentrations i.e 1.0, 2.0, 4.0 and 6.0 ${\mu}g/g$ BW on day 8 of gestation. Fetuses recovered on day 18 of gestation were analyzed on morphological, morphometric and histological basis. Morphological observations showed defects like open eyelids, anophthalmia, fore and hindlimb micromelia, meromelia, amelia, sacral hygroma, hydrocephaly, hemorrhagic spots, kyphosis and clubbed feet. Morphometric analysis indicated a significant (p<0.001) reduction in fetal body weight, crown rump length, head circumference, eye circumference, forelimb and hindlimb lengths and tail size against controls. The histological observations showed brain defects like hydrocephaly, enlarged ventricles and undifferentiated neuroglial cells in cerebellum. Cleft palate, underdeveloped pharynx and atrophy of jaw muscles were the common anatomical defects of pharyngeal region. It is concluded that the concentrations of clomiphene citrate used during the present study proved teratogenic in mice fetuses.

Diagnostic Role of Stroboscopy (후두 내시경의 진단적 역할)

  • Lee, Sang-Hyuk
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.21 no.1
    • /
    • pp.13-16
    • /
    • 2010
  • Diagnosis of a patient with dysphonia begins with a thorough history and physical examination. Larynx can be visualized either indirectly or directly with a rigid or flexible laryngoscope. One notable limitation of simple indirect laryngoscopy is that the examination dose not yields a recordable and reproducible image of the larynx and vocal tract. And unaided human eye is unable to visualize the vibratory patterns of the true vocal cord during phonantion. When available, stroboscopy provides useful information regarding vocal told closure, vibration, and mucosal wave which is useful to decide between microsurgery, vocal reeducation or a combined treatment Even there are some limitations, recognition of the advantages and disadvantages of stroboscopy allows for optimal appreciation and stroboscopy remains an essential diagnostic tool in the assessment of dysphonia.

  • PDF