• 제목/요약/키워드: Extracorporeal circulation system

검색결과 20건 처리시간 0.027초

개심술중 섬유소융해계의 활성화에 관한 연구 (Activation of Fibrinolytic System during Open Heart Surgery)

  • 박이태;서경필;이정상
    • Journal of Chest Surgery
    • /
    • 제22권4호
    • /
    • pp.525-547
    • /
    • 1989
  • Hemorrhagic tendency observed in open heart surgery patients has been attributed, among other causes, to increased fibrinolytic activity during extracorporeal circulation. But the exact mechanism of enhanced fibrinolytic activity which occurs during extracorporeal circulation is still unknown. So, we studied and compared the changes of parameters of fibrinolytic and protein C system according to time obtained from the plasma of 31 adult open heart surgery patients[EGG group] and 10 adult general thoracic surgery patients[control group], in order to confirm the hypothesis that the activated protein C system might affect the fibrinolytic system during extracorporeal circulation. In ECC group, the nature of the enhanced fibrinolytic activity that evolved during extracorporeal circulation was characterized by significant increase in fibrin degradation products[P < 0.01] and significant decrease in plasminogen and alpha2-antiplasmin[P < 0.05, P < 0.01] in spite of adequate amount of heparin administration. These changes were most pronounced in the early phase of extracorporeal circulation and normalized after termination of extracorporeal circulation. The results of these observations were the same after volume correction with the value of hematocrit. The change of volume corrected protein C ratio during extracorporeal circulation revealed similar pattern to those of plasminogen and alpha2-antiplasmin [P < 0.01], but volume corrected ratio of free protein S showed significant increase after the commencement of extracorporeal circulation then decreased after extracorporeal circulation. Although the above mentioned changes occur similarly in both bubble type oxygenator-used and membrane oxygenator-used patients groups, but the degree of decrease was more severe in membrane oxygenator-used patients group [P < 0.01] and showed much slower recovery to reach to the preextracorporeal circulation level. These results confirm the hypothesis that the enhanced fibrinolysis during extracorporeal circulation might be caused by the activation of protein C system and the activation is possibly linked to the appearance of thrombin from contact activation of blood after wide exposure to the synthetic surfaces of extracorporeal circuit. Key words: Extracorporeal circulation, Enhanced fibrinolysis, Protein C system.

  • PDF

The Concept of Artificial Liver Support by Using the Extracorporeal Circulation System

  • Cheon, Min-Woo
    • Transactions on Electrical and Electronic Materials
    • /
    • 제16권1호
    • /
    • pp.25-28
    • /
    • 2015
  • In this study, a basic research on artificial liver was performed for its application to people on the waiting list of liver transplant or patients with hepatic insufficiency. Artificial livers are generally classified into mechanic type, bioartificial type, and hybrid type. An extracorporeal circulation device was examined herein, which is indispensable in the application of an artificial liver, for its effectiveness in supporting the recovery of liver functions. Extracorporeal circulation system is a treatment and life-support system which sends out the patient's blood, removes toxicity by various methods, and then sends the blood back to the interior of the body. This study used an extracorporeal circulation system which enables the Plasma Perfusion by CVVH method, and applied the program of Bioateco corp. Animals with acute hepatic insufficiency were produced to apply the extracorporeal circulation device. As a result, their ammonia, bilirubin, SGOT, SGPT, and bile acid levels rose, confirming the liver function restoration in the experimental animals.

장시간의 체외순환이 생체에 미치는 영향 (Influences of Prolonged Extracorporeal Circulation on Organ Function in Dogs)

  • 김의윤
    • Journal of Chest Surgery
    • /
    • 제7권1호
    • /
    • pp.73-78
    • /
    • 1974
  • Influences on organ function were studied in animals during prolonged extracorporeal circulation with a bubble type of oxygenator. More than six hours of total cardiopulmonary bypass was performed under mild hypothermia by means of an extracorporeal circulation system in five dogs. Obtained results were summarized as follows. 1. The renal function was not so impaired seriously until four hours of extracorporeal circulation. However, there was more serious impairment of renal function in this study when extracorporeal circulation was carried out for a period of five hours or more. 2. There was gradual hepatic damage during extracorporeal circulation and the damage was more significant after bypass for a period of five to six hours. 3. There was a significant decrease in serum K during bypass, irrespective of the pump oxygenator prime with a high K solution. The reason for this is complex and due to many factors, however, it was evidently related to serum glucose levels during extracorporal circulation.

  • PDF

ECMO 시스템 적용을 위한 최적화 조건에 관한 연구 (A study on the Optimal Condition for Application with Extracorporeal Membrane Oxygenation)

  • 김재열;송민종;유신;마상동;김창현
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 기술교육위원회 창립총회 및 학술대회 의료기기전시회
    • /
    • pp.13-18
    • /
    • 2001
  • The ECMO system, including umbilical cord and membrane type oxygenator was connected with extracorporeal circulation unit, was applied to the fetus growth model of goat. The maximum survival time of goat fetus was 48 hours. Average blood rate for the extracorporeal circulation was $223{\pm}15.2 ml/min.$ The survival time of fetus was deeply related to body temperature, blood circulation and water temperature, anesthetized time, and fetus weights. Extern variables that are composed of anesthetized time, fetus weights, change of hemoglobin, circuit pressure, related to the survival time for fetus corrected the problem of previous ECMO model that is controlled by roller pump. It is directly delivered to heart on load. Applying the results from new ECMO model, further research will provide to the system of ECMO for human.

  • PDF

체외 순환 보조 장치 위한 공기방울 감지 장치 개발 (Development of Bubble Detector for Extracorporeal Circulation Support System)

  • 이혁수
    • 융합신호처리학회논문지
    • /
    • 제11권4호
    • /
    • pp.298-302
    • /
    • 2010
  • 체외 순환 보조 장치는 호흡부전 및 심부전 등에 사용하는 장치이며 세계적으로 많은 연구 개발과 임상에의 사용이 계속되고 있다. 이 장치들을 사용할 때 주의해야할 사항중 하나는 공기 색전증이다. 공기 색전증은 정맥혈내로 공기가 들어갈 수 있는 여러 가지 수술 과정 및 진단 과정의 합병증으로 일어날 수 있으며, 수술부위가 심장보다 위치, 수술 과정 중 체강, 체외 순환 보조 장치를 사용할 때 공기의 유입이 생길 수 있다. 이러한 문제를 해결하기위해 비유전율 상수의 변화를 이용한 공기방울 감지 장치를 개발했다. 모의순환 장치에서 실험해본 결과 튜브 안의 공기 양에 따라 신호의 차를 분명하게 보여주어 공기방울을 감지할 수 있었다.

체외순환후 혈청내 Immunoglobulin 과 보체의 변화에 관한 연구 - 막형 인공산화기와 기포형 인공산화기의 비교 - (Changes of Plasma Immunoglobulins and Complements after Extracorporeal Circulation)

  • 이철주
    • Journal of Chest Surgery
    • /
    • 제21권4호
    • /
    • pp.613-618
    • /
    • 1988
  • The exposure of blood to foreign materials can cause the denaturation of plasma protein components such as immunoglobulins and complements. And those phenomena increase the morbidity and mortality after intracardiac operations through the cardiopulmonary bypass. From April, 1987 to September, 1987, we had observed the serial changes of plasma total protein IgG, IgA, IgM, complements[C3, C4] in bubble oxygenator group[n=5] and membrane oxygenator group[n=5]. Statistically significant difference between two groups were present in total protein and C3. We conclude that using membrane oxygenator in long extracorporeal circulation can reduce the activation of alternative pathway of complement system, and which can reduce post-perfusion complications of the lung though we can`t prove it in mass populations.

  • PDF

체외순환에서 박동 혈류와 비박동 혈류가 신장의 조직관류에 미치는 영향 (Effect of Pulsatile Versus Nonpulsatile Blood Flow on Renal Tissue Perfusion in Extracorporeal Circulation)

  • 김현구;손호성;방영호;박성영;김광택;김학제;선경
    • Journal of Chest Surgery
    • /
    • 제38권1호
    • /
    • pp.13-22
    • /
    • 2005
  • 배경 : 심장수술과 같은 체외순환(Extracorporeal circulation)이 요구되는 상황에서 조직관류에 우월할 것으로 보이는 박동성 혈류장치를 이용하려는 시도가 계속되어 왔다. 본 연구에서는 체외순환 조건에서 박동 혈류가 비박동 혈류보다 조직관류에 우월하다는 가설을 직접 증명하기 위해 치근 개발된 조직관류측정기($QFlow^{TM}-500$ Perfusion Measurement System, Thermal Technologies Inc.,Cambridge, MA, USA)의 열확산 탐침(Thermal Diffusion Probe)으로 조직 관류량을 실시간 및 연속적으로 직접 측정함으로써, 체외순환에서 박동 혈류와 비박동 혈류가 신장에 미치는 영향을 직접 관찰하고자 하였다. 대상 및 방법: 몸무게가 25 kg에서 40 kg 사이의 돼지를 암수 구별 없이 총 12마리를 각각 6마리씩 두개 군으로 나누어 실험을 진행하였다. 동물의 심장을 노출시킨 후, 좌측 측하복부를 절개하여 좌신장을 노출하여 관류측정기의 열확산 탐침을 신장의 피질내에 $2\~3$ cm 깊이로 거치하였다. 9볼트의 배터리로 심정지를 유도하면서 대동맥 차단을 하여 총심폐우회술을 시행한 후, 1군(n=6)은 Biopump에, 2군(n=6)은 박동식 혈류를 제공하는 T-PLS (Twin-Pulse Life Support System)에 연결하였다. 실험 동안 pump flow는 2 L/min로 유지하였다. 체외순환 전과 시작 후 10분마다 심박수, 혈압, 및 신장 관류치를 측정하여 60분까지 측정하고, 동맥혈가스분석, 전혈구 계산, 혈액 뇨질산, 크레아티닌 및 혈장 용혈헤모글로빈을 체외순환 시작 전과 60분 후에 측정하였다. 결과: 두 군 사이에 기초치는 유사하였다. 평균 혈압은 체외순환 전에는 두 군 간에 차이가 없었으나, 체외순환 20분 이후부터는 2군에서 높은 경향이 있었고(1군 $39.84\~45.5$ mmHg, 2군 $48.7\~52$ mmHg), 특히 60분에서의 평균혈압은 통계적으로 유의한 차이를 보였다(1군$\;41.2{\pm}4.3\;mmHg,\;48.7{\pm}5.4\;mmHg,\;p=0.023$). 체외순환 전 측정한 신장 관류치는 두 군간에 차이가 없었으나, 체외순환을 시작한 이후부터는 2군에서 지속적으로 더 높은 경향이 있었으며(1군 $48.5\~64$ mL/min100 g, 2군 $65.8\~88.3$ mL/min/100 g), 특히 30분에서의 측정값은 통계적으로 유의한 차이를 보였다(1군$47.5{\pm}18.3\;mL/min100\;g,$ 2군$83.4{\pm}28.5\;mL/min100\;g,\;p=0.026$). 혈액 뇨질산, 크레아티닌, 그리고 혈장 용혈헤모글로빈의 변화는 두 군간에 차이가 없었다. 결론: 일정한 펌프 혈류 조건에서 박동성 혈류의 평균 혈압이 더 높다는 것은, 비박동성 혈류보다 조직관류압(Tissue Perfusion Pressure) 측면에서 우수하여 말초장기의 조직관류 효과에 유리한 요인이라고 볼 수 있다. 본 연구를 토대로 장시간의 체외순환에서는 신장기능을 대표하는 수치들에도 영향을 미칠 수 있으리라 예상되며, 신장 이외에 다른 주요 장기에 미치는 영향에 대한 연구를 더 진행할 필요가 있을 것으로 생각한다.

Sarns 심폐기의 혈희석 체외순환에 관한 실험적 연구 (Experimental Studies on Extracorporeal Circulation by Sarns Heart-Lung Machine with Total Prime of Hartman's Solution)

  • 김근호
    • Journal of Chest Surgery
    • /
    • 제8권2호
    • /
    • pp.135-142
    • /
    • 1975
  • Total body perfusion using Sarns Heart-Lung-Machine, five head pump motor system with Travenol disposable bubble oxygenator was attempted in the dogs by the hemodilution method with total prime of buffered Hartman`s solution under moderate hypothermia. The first of all, the functions of Sarns Heart-Lung-Machine and effects of the hemodilution perfusion by buffered Hartman`s solution was studied. At the same time the changes of pressure of artery and vein, gas contents of the blood, and influence on the blood pictures were observed before, during, and after perfusion in 1-2 days. Hemodilution rates were the ranges of 85.0ml/kg to 97.3ml/kg and perfusion flow rates were maintained with the average 80. 5ml/kg/min [the ranges of 73.3ml/kg/min to 92.8ml/kg/min]. Hypothermia was employed between $35^{\circ}C$ and $31^{\circ} of the esophageal temperature. The total body perfusion was continued for 50-60 minutes. In the total cardiopulmonary bypass, atriotomy, ventriculotomy, and atrioventriculotomy were performed respectively. Arterial pressure was ranged approximately between 50 mmHg and 140 mmHg, but generally, it was maintained over 75 mmHg. Venous pressure was measured between 3.8 cm$H_2O$ and 16.0 cm$H_2O$. Optimum oxygenation could be achieved when oxygen flow into the oxygenator was maintained approximately at 5. 5L/min. In this way, the $pO_2$, $pCO_2$, and oxygen saturation were measured before, during, and afterperfusion in 1-2 days. The $pCO_2$ ranged approximately between 26.0 mmHg and 38.5 mmHg, but generally, it was maintained in the average 30.9-32.5mmHg. The $pO_2$ was ranged between 73.0mmHg and 332.2 mmHg, but it was maintained in the average 103.0-219.0 mmHg. Oxygen saturation was measured over 95. 0% during and after extracorporeal circulation respectively. Erythrocyte count, hemoglobin, hematocrit, and leucocyte count were decreased to 49.2%, 49.0%, 49.4%, and 21. 1% of the preoperative value during extracorporeal circulation respectively and these reductions were not recovered until 1-2 days after perfusion. These. resulted from relatively high degree of hemodilution rate and operative bleeding during these experimental studies. The platelets count was also decreased about to 71% during perfusion, on the contrary, it was increased progressively after perfusion and in 1-21 days after perfusion, the value was returned to preoperative contro1 level. Three dogs were all recovered after extracorporeal circulation.

  • PDF

이중 박동성 인공심폐기(Twin-Pulse Life Support, T-PLS)를 이용한 심폐순환보조 (Extracorporeal Life Support with a Twin-pulse Life Support (T-PLS) System)

  • 이동협;이장훈;정태은
    • Journal of Chest Surgery
    • /
    • 제40권7호
    • /
    • pp.512-516
    • /
    • 2007
  • 기계적인 순환보조장치는 급성호흡부전이나 심부전에서 생명을 구할 수 있는 방편의 하나이다. 현재 여러 가지 형태의 순환 보조장치가 있으며 Twin-Pulse Life Support (T-PLS) system은 박동형 펌퍼의 한 종류다. 3예의 심한 심폐기능부전 상태 환자에게 순환보조장치로 T-PLS system을 사용하였다. 적응증은 인공호흡기와 강심제를 최대한 사용함에도 불구하고 지속되는 호흡부전이나 심부전이었다. 감염에 의한 호흡부전환자가 2예, 심근염에 의한 심부전 환자가 1예였다. 각각 한 명의 호흡부전환자와 신부전 환자가 생존하였는데 보조장치의 사용시간은 각각 3일과 5일이었다. T-PLS system은 순환보조장치로 유용하게 사용할 수 있으며 다발성 장기부전이 오기 전에 적용하여야 할 것으로 생각된다.

원심형 혈액펌프의 최적화 수력설계 및 성능해석 (Hydraulic Design Optimization and Performance Analysis of a Centrifugal Blood Pump)

  • 박무룡;유성연;오형우;윤의수
    • 대한기계학회논문집B
    • /
    • 제30권1호
    • /
    • pp.87-94
    • /
    • 2006
  • This paper presents the hydrodynamic design and performance analysis method for a miniaturized centrifugal blood pump using three-dimensional computational fluid dynamics (CFD) code. In order to obtain the hydraulically high efficient configuration of a miniaturized centrifugal blood pump for cardiopulmonary circulation, a well-established commercial CFD code was incorporated considering detailed flow dynamic phenomena in the blood pump system. A prototype of centrifugal blood pump developed by the present design and analysis method has been tested in the mock circulatory system. Predicted results by the CFD code agree very well with in vitro hydraulic performance data for a centrifugal blood pump over the entire operating conditions. Preliminary in vivo animal testing has also been conducted to demonstrate the hemodynamic feasibility for use of centrifugal blood pump as a mechanical circulatory support. A miniaturized centrifugal blood pump developed by the hydraulic design optimization and performance prediction method presented herein shows the possibility of a good candidate for intra and extracorporeal cardiopulmonary circulation pump in the near future.