• Title/Summary/Keyword: Extinguishing Test

Search Result 104, Processing Time 0.026 seconds

Development for the Water Mist Package Having a Low Pressure Nozzles on Wooden Cultural Properties and Temples (중저압 노즐을 이용한 사찰 및 목조 문화재용 미분무 패키지 소화설비 개발)

  • Kim, Tae-Hwan;Myeong, Sang-Yeong
    • Fire Science and Engineering
    • /
    • v.24 no.4
    • /
    • pp.62-68
    • /
    • 2010
  • The present study purposed to develop the water mist package system for the cultural properties fire prevention and fire suppression system through analyzing fire protection system and cultural property's characteristic, and to suggest directions for the development of cultural property fire prevention system in the future. Maximum safety with minimum damage has issued a main objective in fire protection of the cultural property in Korea. Two types of the water mist nozzles having a low pressure had been developed by KEI. The one is for inside using in wooden cultural properties, the flow rate is 30~35 l/min and the discharging pressure is 13~14 bar. The other one is for out-side of wooden properties, the flow rate is 25~30 l/min and the discharging pressure is 14~15 bar. To evaluate the nozzles performance test, we made the fire scenario and full-scale model of wooden cultural properties for fire test. The size of full-scale model was 4.9 m length, 4 m wide, 6.6 m height, all was made by wooden. This real fire test results showed that the low pressure water mist nozzles having a $200{\mu}m$ dour size were very effectively fire extinguishing and suppression on wooden cultural properties fire. Even though the oil fuel fire was not extinguished, the fire suppression effects for the during mobilization of fire brigade was enough.

Study of Insam-Buja-Tang (IBT) on MRL/MpJ-Faslpr lupus-prone mice (루푸스 동물 모델에서 인삼부자탕(人蔘附子湯)이 미치는 영향)

  • Kim, Kyoung-Shin;Moon, Sung-Sikm;Kim, Byoung-Soo;Kang, Jung-Soo
    • Journal of Haehwa Medicine
    • /
    • v.20 no.1
    • /
    • pp.11-23
    • /
    • 2011
  • Systemic Lupus Erythematosus(SLE) is an autoimmune disease invading the skin, joint, kidney, intestinal membrane, neurosystem and other organs. SLE is an autoimmune disease characterized by immune dysregulation resulting in the production of antinuclear antibodies(ANA), generation of circulating immune complexes, and activation of the complement system. In Korean medicine, lupus can be classified as acute arthritis, reddish butterfly erythema, asthenic disease, edema and so on. The cause and procedure of the diseases are flourishing noxious heat, excessive fire due to deficiency of yin, blood stasis due to stagnation of qi, internal movement of the liver-wind, congenital deficiency, exhausted vital-qi, which are treated by clearing away heat and cooling the blood, nourshing yin and extinguishing fire, treating flatulence and activating blood circulation, nourishing the blood to expel wind, invigorating the liver and kidney, invigorating qi and replenishing the blood. To experimentally examine the influence of Insam-Buja-Tang (Ginseng & Aconiti Extract, IBT) on the outbreak and development of lupus, lupus induce MRL/MpJ-Faslpr lupus-prone mice model was used. As IBT was orally administrated to a lupus model mouse, various tests such as the weight, urine protein, renal function, Lymph cell test of the spleen, Cytokine expression, histopathological analysis of kideny were performed to see the influence on the kidney and whether it work effectively on the immune function. The main purpose of this study is to evaluate the effect of IBT on MRL/MpJ-Faslpr lupus-prone mice model. The effect of IBT on MRL/MpJ-Faslpr lupus-prone mice that can have autoimmune disease similar to SLE in human was evaluated after IBT per oral in the present study.

SLI, AC Breakdown Voltage Characteristics of $SF_6/CF_4$ Mixtures Gas in Nonuniform Field (불평등전계에서 $SF_6/CF_4$ 혼합 가스의 SLI, AC 절연내력 특성)

  • Hwang, Cheong-Ho;Sung, Heo-Gyung;Huh, Chang-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.2
    • /
    • pp.245-251
    • /
    • 2008
  • Although many studies have been carried out about binary gas mixtures with $SF_6$, few studies were presented about breakdown characteristics of $SF_6/CF_4$ mixtures. At present study the breakdown characteristics of $SF_6/CF_4$ mixtures in non-uniform field was performed. The experiments were carried out under AC voltage and standard lightning impulse(SLI) voltage. Breakdown characteristics were investigated for $SF_6/CF_4$ mixtures when AC voltages and standard lighting impulse voltage was applied in a needle-plane. The needle-plane electrode whose gap distance was 3 mm were used in a test chamber. $SF_6/CF_4$ mixtures contained from 0 to 100% $SF_6$ and the experimental gas pressure ranged from 0.1 to 0.5 MPa. The breakdown characteristics of $SF_6/CF_4$ mixtures in non-uniform field may be influenced by defects like needle-shaped protrusions. In case of slowly rising SLI voltage and AC voltage it is enhanced by corona-stabilization. This phenomena caused by the ion drift during streamer development and the resulting space-charge is investigated. In non-uniform field under negative SLI voltage the breakdown voltage was increase linearly but under positive SLI voltage the breakdown voltage increase non-linearly. The breakdown voltage in needle-plane electrode displayed N shape characteristics for increasing the content of $SF_6$ at AC voltage. $SF_6/CF_4$ mixture has good dielectric strength and arc-extinguishing properties than pure SF6. This paper presents experimental results on breakdown characteristics for various mixtures of $SF_6/CF_4$ at practical pressures. We could make an environment friendly gas insulation material with maintaining dielectric strength by combing $SF_6\;and\;CF_4$ which generates a lower lever of the global warming effect.

An Forest Ecological Environment Impact Assessment of Forest Fire Suppression Chemicals - To Plants & Soil Organism - (산불 진화용 소화약제의 산림생태환경 영향 평가 - 식물 및 토양생물독성에 대하여 -)

  • Kim, Dong-Hyun;Lee, Myung-Bo;Yoo, Se-Kuel;Na, Young-Eun;Choi, Won-Il;Kim, Eung-Sik;Jung, Ki-Chang
    • Fire Science and Engineering
    • /
    • v.22 no.5
    • /
    • pp.48-54
    • /
    • 2008
  • Forest fires occur the world over, with large-scale fires constantly breaking out. A suppressant a type of forest fire chemical is widely used to respond to fires rapidly and effectively. In general, suppressants used for fires have been divided into dry powder, liquid, foam, and gel type, according to physical form and use. This study has conducted toxicity tests relating to phytotoxicity(Pinus densiflora seed germination rate and mortality of containerized seedling), and soil organism toxicity(earthworm acute toxicity tests), of these suppressants, with the loaded stream suppressant for direct forest fire extinguishing a Loaded Stream and foam concentrates generally being used in Korea. From the results of the tests, the loaded stream and the foam concentrate had an effect on the toxicity levels. In the case of the loaded stream type, it was observed that toxicity indicating a 100% lethality rate was found among all toxicity test methods. Therefore, it is determined that forest ecology environmental toxicity impact assessments related to the suppressant used to extinguish forest fires are necessary in the near future.

Evaluation of Design Fire Curves for Single Combustibles in a Cinema Complex (복합영상관 단일 가연물의 디자인 화재곡선 평가)

  • Jang, Hyo-Yeon;Hwang, Cheol-Hong;Oh, Chang Bo;Nam, Dong-Gun
    • Fire Science and Engineering
    • /
    • v.34 no.3
    • /
    • pp.18-27
    • /
    • 2020
  • An actual fire test was performed on single combustibles placed in a local cinema complex, and quantitative differences in the maximum heat release rate (HRR) and fire growth rate were investigated based on the design fire curve methods (i.e., the general and 2-stage methods). In terms of combustible use and fire load, a total of 12 combustibles were selected, classified into cinema lounge and movie theater. It was found that the maximum HRR and fire growth rate determined using the two-stage method were quantitatively different from those of the general method. The application of the two-stage method, which can be used to determine the fire growth rate of the initial fire stage more precisely, could be useful in accurately predicting the activation time of fire detectors and fire-extinguishing facilities, as well as the available safe egress time (ASET) and required safe egress time (RSET).

A Commodity Classification Method of Domestic Rack-Type Warehouse for Sprinkler System Design (스프링클러 설계를 위한 국내 적층형 물류창고의 수용물품 등급분류 방법)

  • Yang, So-Jin;Lee, Young-Jae;Kim, Woon-Hyung;Dewey, James M.;Ham, Eun-Gu
    • Journal of the Society of Disaster Information
    • /
    • v.15 no.4
    • /
    • pp.531-539
    • /
    • 2019
  • Purpose: The purpose of this study is to present the commodity classification method of domestic rack-type warehouse for sprinkler system design. Method: On-site surveys and classification criteria of the NFPA, FMDS, EN and Japan were analysed and ISO 12949 test were carried out with proposed each classification commodity. Result: Based on a heat of combustion, a classification method for extra high, high, medium and low are proposed. Conclusion: Sprinkler design criteria to secure the maximum extinguishing strength for each class of commodity need to be applied.

A Numerical Study on the Design of Water Mist Lance for Fire Suppression in Container (컨테이너 내부 화재진압을 위한 물분무창 설계에 관한 수치적 연구)

  • Han, Sang-goo;Choi, Jae-hyuk;Lee, Won-Ju
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.23 no.7
    • /
    • pp.941-947
    • /
    • 2017
  • Increasing marine transportation of dangerous goods using containers causes fire accidents on ships due to leakage of dangerous materials. In IMO (MSC.93), all vessels that are to be loaded five or more containers on weather deck area after 1 January 2016 are required to have a fire extinguishing system called Water Mist Lance (WML) on board. In this study, numerical analysis is performed to design WML with optimal edge radius of curvature using LS-DYNA. The analysis results for the three models with 10 mm, 15 mm and 20 mm lengths of the edge part showed that the only model with 15 mm length penetrated the wall of the container and did not cause damage to the edge of the WML. In the future, based on the results of this study, we will make a WML of prototype and conduct a performance test. And we will continue to improve the problems.

Development and Field Test of a Smart-home Gas Safety Management System (스마트 홈 가스안전관리 시스템 개발 및 현장시험)

  • Park, Gyou-Tae;Kim, Eun-Jung;Kim, In-Chan;Kim, Hie-Sik
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.6
    • /
    • pp.128-135
    • /
    • 2012
  • In this paper, we proposed a system and a scenario to raise efficiency of gas safety management by developing wireless ZigBee communication modules, smart-home gas safety appliances and the system suitable for gas safety. Our designed system consists of a micom gas meter, an automatic extinguisher, sensors, and a wall-pad. A micom-gas-meter monitors gas flow, gas pressure, and earthquake. An automatic fire extinguisher checks combustible gas leaks and temperature of $100^{\circ}C$(cut off) and $130^{\circ}C$(fire). Sensors measure smoke and CO gas. In our novel system, a micom-gas meter cut off inner valve with warnings, an automatic fire extinguisher cut off middle valve and spray extinguishing materials, and sensors generate signals when detecting smoke and CO and then take a next action. Gas safety appliances and sensors automatically takes measures, and transmit those information to a wall-pad. The wall-pad again transmits real time information to server. Users can check and manage gas safety situations by connecting BcN server through web or mobile application. We hereby devised scenarios for gas safety and risk management based on the smart, and demonstrated their efficiency through test applied to filed.

An Experimental Study on a Discharge Pressure, Flow Rate and Foam Discharge Concentration through the Nozzle According to the Foam Suction Nipple Diameter (노즐 구경에 따른 포 수용액의 압력과 유량 및 농도 변화에 관한 실험적 연구)

  • Jang, Kyung-Nam;Lee, Maing-Ro;Park, Bong-Rae;Yun, Ki-Jo;Baek, Eun-Sun
    • Fire Science and Engineering
    • /
    • v.29 no.2
    • /
    • pp.84-91
    • /
    • 2015
  • The purpose of this study is to suggest the reasonable model of the caliber in suction nozzle, the pressure of suction nozzle, and the flow rate about foam system of line proportioner type using in the pumpcar. To test this, the experimental study was accomplished on the ground of the standards for the Performance Certification and Product Inspection of Foam Fire-extinguishing Chemical Mixing Machine. Aqueous Film Forming Foam in 3% and pipe type air foam nozzle with line proportioner FE 40 type were used. Test result showed that the pressure of suction nozzle within the limits between 0.25 MPa and 0.35 MPa was appropriate when the caliber in suction nozzle is 4 mm. Also, the pressure of suction nozzle within the limits between 0.45 MPa and 0.60 MPa was appropriate in the higher pressure than 4 mm when the caliber in suction nozzle is 5 mm.

A Study on the Confirmation of non-flammabikity of the Cast Resin Mold Transformer in Subway Substation (지하철 변전실용 진공주형형 몰드변압기의 난연성 확인에 관한 연구)

  • 정용기;장성규;곽희로
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.2
    • /
    • pp.99-107
    • /
    • 1998
  • This dissertationhas confirmed the non-flam mability of cast mold transformer that is increasingly used lately. As a research progress, the investigation has been performed on the installation status and each line of the subway system which have the most mold transformer accidents, and the impediment status of the transformer for rectifier and the high-voltage distribution transformer per each manufacturer. Then, a high voltage mold of the actual mold transformer has been installed in the horiwntal heating furnace and the heat has been applied by the standard heating temperature curve of KSF 2257(Fireproof testing meth od of the construction structures: 1993). Accordingly, the combustibility of the mold transformer based on the test results has been found that 78 minutes has been required for the complete burning per the KSF 2257 combustion test curve and that, after stopping the heat application of the horizontal furnace after ignition, the flame progress has not been made but shown as the self-extinguishing characteristics when the flame progress has been checked. Thus, the non-flammability and self-extinguishability of the mold transformer have been confirmed. The result of this dissertation has indicated that the accident involving mold transformer has been progressed and expanded by the dielectric breakdown or void due to the crack in the mold rather than a fire accident caused by a short-circuit or an overload.r an overload.

  • PDF