실리콘 고무의 부분방전 특성에 관한 연구 (A Study on Properties of Partial Discharge in Silicone Rubber)

  • 이성일;권영천
    • 한국전기전자재료학회논문지
    • /
    • 제24권11호
    • /
    • pp.890-894
    • /
    • 2011
  • In this thesis, the silicone filler with a sample size of 0~75 phr and void size of 2~4.5 mm is prepared in order to diagnose the defect of void which exists in widely used insulation material, silicone rubber. In this silicone rubber sample, electrodes are connected and whilst the voltage changes, applied voltage 7 kV~9 kV is increased constantly over time and discharge quantity, discharge frequency and applied voltage (T-QNV) were measured. The discharge quantity of the applied voltage (VQ) is measured to estimate inception voltage and extinction voltage. In addition, under the condition of maintaining constant applied voltage, discharge quantity and discharge frequency (QN) are measured, and its characteristics are analyzed.

초전도 코일의 유도성 에너지에 의한 아크현상과 유기 과전압 (Arc Phenomena and Induced Voltage due to Inductive Energy of Superconducting Coil)

  • 최병주;류경우;성기철;김해종
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제2권1호
    • /
    • pp.24-30
    • /
    • 2000
  • This paper present the characteristics of the internal induced voltage and arc phenomena in liquid helium at the energy transfer from a superconducting magnet to a load resistor. Especially generation mechanism of the oscillated wave from of the coil terminal voltage is analyzed by considering circuit constant of the superconducting magnet, load condition and arc resistance of the mechanical opening switch. The wavefront and peak portion of the voltage are strongly influenced by arc discharge triggered by the switch separation in liquid helium. Abrupt arc extinction leads to voltage oscillation with an enormous peak. It is suggested that the superconducting magnet should be designed to ensure the internal surge when arc is possibly formed by switch opening or coil short circuit between turns or layers. Finally, a suppression method of the oscillating surge is proposed based on the load condition.

  • PDF

Investigation of Interplay between Driving Voltage of MZ Modulators and Bandwidth of Low-pass Filters in Duobinary Modulation Formats

  • Lee, Dong-Soo
    • 조명전기설비학회논문지
    • /
    • 제20권9호
    • /
    • pp.11-17
    • /
    • 2006
  • We have theoretically investigated the effects of the interplay between the driving voltage of Mach-Zehnder(MZ) modulators and the bandwidth of low-pass filters(LPF) in 10[Gb/s] duobinary modulation systems. For the change of driving voltage ratios(driving voltage/switching voltage), the transmission performance has been evaluated over 200[km] of single-mode fiber(SMF) systems. For driving voltage ratios with smaller than 100[%], the transmission performance has been maintained and greatly affected by the bandwidth of LPFs than the driving voltage. For driving voltage ratios with larger than 100[%], the transmission performance has been degraded and is not sensitive to the bandwidth of LPFs. To see the limitation of driving voltage, we have reduced the driving voltage ratio to 50[%]. Our results suggest that 10[Gb/s] duobinary signals with driving voltage ratio with smaller than 100[%] have been transmitted over 200[km] SMF within 2[dB] power penalty without dispersion compensation. For the driving voltage ratio with 50[%], we have verified that the transmission performance was maintained.

미분무수 분사의 제연효과 (Smoke Removal Effect by Water Mist Spraying)

  • 박태성;공하성;김명철
    • 한국화재소방학회논문지
    • /
    • 제29권3호
    • /
    • pp.43-47
    • /
    • 2015
  • 구획된 소규모 공간내부에 각 경우별로 서로 다른 두 종류의 가연물로부터 발생된 연기(smoke)를 채운 후 미분무 헤더를 통해 분사압력과 분사시간을 서로 달리하면서 미분무를 분사하였으며, 이후 시간경과에 따른 광소멸상수의 변화 값을 측정하였다. 미분무가 구획된 공간내부에서 분사될 경우 각각의 실험조건에 따른 연기제거효과의 패턴과 차이점은 감광식 연기농도계를 통해 고찰하였다. 실험에 이용된 감광식 연기농도계를 통해 시간변화에 따른 연기밀도의 변화값을 직류전압(DC voltage)의 변화값으로 확보할 수 있었으며, 이를 통해서 광소멸상수의 변화를 알 수 있었다. 훈소(glowing)에서 발생한 연기가 불꽃연소(flaming combustion)에서 발생한 연기보다 연기의 제거효과가 컸으며, 분사압력이 높을수록, 분사시간이 길수록 연기제거효과는 크게 나타났다.

교류 피복 아크 용접에 있어서 아크 안정성의 정량적 평가에 관한 연구 (A Study on the Quantitative Evaluation of Arc Stability in AC SMAW)

    • Journal of Welding and Joining
    • /
    • 제16권4호
    • /
    • pp.125-135
    • /
    • 1998
  • The shielded metal arc welding (SMAW) by AC power source was performed to evaluate the arc stability by arc monitoring and analysing. In this study, the arc stability index was evaluated quantitatively by using he coefficient of resistance variation for welding time. This coefficient was obtained for the long time (20sec.) by analysing the waveforms of welding current, voltage and resistance. The coefficient was applied to indicate numerically the variation level of arc length and the degree of arc extinction. Using the coefficient of resistance variation in practical welding, the arc stability of the high titanium oxide electrode (KS E4313) turned out to be better than that of the low hydrogen electrode (KS E4316). In evaluating the skill level of welders by the coefficient, the horizontal fillet weaving welding became clear to be very discriminating because the higher level welder could weave in keeping constant arc length, but the lower level welder showed the characteristics of weaving with the unstable arc length. And it was confirmed that the welding defects as blow holes was formed when the arc stability index were high.

  • PDF

SF6, g3 및 Dry Air 절연에서 PD 특성 비교 분석 (Comparative Analysis of PD Characteristics Under SF6, g3 and Dry Air Insulation)

  • 신한신;김남훈;김성욱;길경석
    • 한국전기전자재료학회논문지
    • /
    • 제33권6호
    • /
    • pp.490-494
    • /
    • 2020
  • Sulphur hexafluoride (SF6) is mostly used as a current-insulating medium in gas-insulated switchgears (GIS), owing to its excellent dielectric strength and arc-extinguishing performance. The global warming potential (GWP) of SF6, however, is 23,900 times that of CO2, and its life time in the atmosphere is 3,200 years. For these reasons, new eco-friendly gases to replace SF6 are required. In this study, the partial discharge (PD) characteristics of green gas for grid (g3) and dry air (N2/O2) were analyzed to compare with those of SF6. A PD electrode system was designed to simulate the protrusion defect in GISs and fabricated for experimentation. To compare the PD characteristics of each gas, the discharge inception voltage (DIV), discharge extinction voltage (DEV), discharge magnitude, discharge pulse number, and phase pattern were analyzed. Results from this study are expected to provide fundamental materials for the design of eco-friendly GISs.

고압전동식용 진단차식기의 스위칭써지 해석 및 연구 (A Study on the Reduction Method and the Analysis of VCB Switching Surge for High Voltage Induction Motor)

  • 이은웅;김종겸;김택수;이성철
    • 대한전기학회논문지
    • /
    • 제43권5호
    • /
    • pp.761-769
    • /
    • 1994
  • VCB (Vacuum Circuit Breaker), with the strong arc extinction capability in switching the source of an induction motor, occurs the severe switching surge voltage which can cause the breakdown or the deterioration of motor insulation. Therefore, a method which reduces surge voltage across motor windings is necessary. So, it is analyzed that fast-rise-time surges resulting from VCB switching operations give rise to severe voltage stress on turn insulation. Additionally, the switching surge simulation algorithms using EMTP are developed, and C, R values of surge suppressor minimizing the steep-fronted stress in winding insulation surges are calculated.

공진특성을 가지는 온도제어시스템의 스위칭 기법 연구 (A Study for the Switching Method of the Temperature Control System with the Resonance Feature)

  • 박활곤;박철우;최연호;구본호;권우현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 A
    • /
    • pp.87-90
    • /
    • 2003
  • There are generally two temperature control methods using ac voltage regulators - the phase control method and the on-off control method. The phase control method uses thyristor's angles of extinction for the output power regulation and the on-off control method uses the control of on and off times for the output power regulation. Both of methods have the problems that are the unbalance of the three phase and surge current caused system's destruction. The main object of this study proposes a solution of problems of surge currents and unbalance of three phase when thyristor voltage regulator is switching. To solve the problem, It is proposes that the solution of surge currents is using a tap transformer and an additional switch with adjustable resistance and applies zero crossing of switching voltage of two input line to power load. This method is discuss and verified by computer simulations and experiments.

  • PDF

AC-AC Voltage Regulator Conditioning Converter with Three Control Schemes

  • Ahmed, Nabil A.;Miyatake, Masafumi;Kang, Ju-Sung;Lee, Hyun-Woo;Nakaoka, Mutsuo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.169-173
    • /
    • 2005
  • In this paper, a comparative study of modified phase-angle, extinction-angle, and pulse width modulation control techniques for the purpose of power factor improvement of single-phase AC-AC voltage regulators have been illustrated as applied to a single-phase ac voltage converter by an example of the widely used single-phase induction motor as a dynamic load. Observations on power factor, displacement factor and total harmonic distortion factor are described and discussed on the basis of the simulated and measured results of this work.

  • PDF

초전도 마그네트 시스템 내부 아크방전에 의한 발생 서어지의 전파특성 (Propagation Characteristics of Surge Generated due to Internal Arc Discharge in Superconducting Magnet)

  • 최병주;말광 순야;원아칙
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1904-1906
    • /
    • 1996
  • Transient voltage distribution tests are carried out to evaluate effects of a high frequency oscillating voltage generated in a superconducting magnet as a result of the arc discharge extinction. Especially, the effects of temperature and conduction state of the magnet conductor on surge behavior are carefully investigated. Based on the results of simulation tests, it is shown that internal voltage waveforms are influenced by its transmission along the superconducting wire and reflection at the terminal and that attenuation process of the waveforms depends considerably on the conductor resistance which decreases with lowering the temperature.

  • PDF