• 제목/요약/키워드: External wall fire

검색결과 27건 처리시간 0.023초

건축물 외단열재의 열전달평가를 통한 화재 억제 방안 연구 (Study on the Fire Suppression by Heat Transfer of Thermal Insulation Materials)

  • 류화성;신상헌;송성용;김득모
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 춘계 학술논문 발표대회
    • /
    • pp.277-278
    • /
    • 2018
  • Improvement of insulation performance of buildings is a major part. Adiabatic method The adiabatic method minimizes the heat loss of the building. External insulation uses insulation to prevent fire. Ambient air hazards are less prone to fire. When a fire occurs, a phenolic pattern is formed and bond strength with the wall increases. EPS insulation and phenol foam were used to compare external heat transfer and external heat transfer. The heat transfer properties of phenolic foam and styrofoam were evaluated as follows. In the mortar and styrofoam structure, the problem of styrofoam reaching the burning point occurred before the collapse of the mortar, and the phenol foam had a problem in that when the direct fire was continued on the phenol foam. The characteristics of continuous infiltration appeared. In the case of mortar and phenol foam + styrofoam, the heat penetrated into the interior due to the shrinkage due to the shrinkage of the carbon screen on the phenol foam. However, when reinforced with glass mesh on the outer surface, And to reduce infiltration.

  • PDF

내화유리를 적용한 강재 유리벽의 내화성능 평가 (The Evaluation of Fire-Resistant Performance of the Non-bearing Steel Wall Using Fire Resistant Glass)

  • 이재승;임현창;양승조
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제22권5호
    • /
    • pp.72-81
    • /
    • 2018
  • 방화구획 내 벽체에는 콘크리트, 조립식 패널, 건식벽체 등을 사용한 내화구조가 주로 적용되고 있으나 근래에 들어 시야 확보 및 미적 관점에 대한 관심이 증가하여 유리로 구성된 벽체의 수요가 발생하고 있다. 본 연구에서는 차열 유리를 적용한 스틸 내화벽체에 관한 것으로써 내부 방화구획에 적용 가능한 60분 내화벽체와 외부 벽체 및 커튼월에 적용 가능한 90분 내화벽체에 대하여 내화시험 및 성능분석을 수행하였다. 시험 결과, 각 시험체의 요구 내화성능을 충족하는 것으로 나타났으며, 추가적으로 유한요소해석을 통한 유리벽체의 내화성능을 평가하였으며 그 결과 1차적으로 시험체의 내화성능을 예측하는 것이 가능한 것으로 판단되었다.

Calculation of Adequate Remodeling Period for The Improvement of Thermal Insulation Performance of External Walls in Deteriorated Apartments

  • Choi, Doo-Sung;Lee, Myung-Eun
    • KIEAE Journal
    • /
    • 제17권2호
    • /
    • pp.5-12
    • /
    • 2017
  • Purpose: Under the purpose of presenting the adequate remodeling period for the improvement of thermal insulation performance of external walls in deteriorated buildings, the change in external wall and residential environment problem(dew condensation) due to aged deterioration after the apartments were constructed in Korea were analyzed. Method: Temperature Difference Ratio Outside(TDRo) and Heat Flow Meter(HFM) were used as measurement methods to evaluate the thermal insulation performance of deteriorated buildings. For TDR evaluation, thermo-graphic camera was used to measure and analyze the surface temperature of external wall. Also, dew condensation evaluation was analyzed using the Temperature Difference Ratio Inside(TDRi). Result: As a result of analyzing thermal performance through TDRo, the first decline point of thermal insulation performance began after 14-16 years have passed since construction was completed, and after 20 years have passed the decline point of thermal insulation performance reappeared. As a result of analyzing U-value with HFM measurement method, the decline rate of external wall's thermal insulation performance is lower than 2% in average at around 5 years after completion, and 8.7% in average at 10-15 years, and over 10.2% in average at 20 years.

UPWARD FLAME SPREAD ON PRACTICAL WALL MATERIALS

  • Kim, Choong-Ik;Ellen G. Brehob;Anil K. Kulkarni
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1997년도 International Symposium on Fire Science and Technology
    • /
    • pp.138-145
    • /
    • 1997
  • Models of upward flame spread have been attempted in the past, but in the current work an emphasis has been placed on developing a practical model that will be useful across a broad range of materials. Some of the important aspects of the model we: the addition of external radiation to simulate a wall that is a part of an enclosure fire and has flaming walls radiating to it, the use of a correlation for flame heat feedback distribution to the sample surface based on data available in the literature, and the use of an experimentally measured mass loss rate for the sample material, In this paper, the development of the numerical model is presented along with predictions of flame spread for three materials: hardboard, a relatively homogeneous wood-based material; plywood, which is made of laminated wood bonded by adhesives; and a composite material made of fiberglass matrix embedded in epoxy. Predictions are compared with measured data at several levels of external radiation for each material. For the materials tested, the model correctly predicts trends and does a reasonable job predicting flame heights. The need for thermal property data for practical materials, which would be appropriate for flame spread models, is indicated by this work.

  • PDF

건축물 외벽화재시 Flame Trajectory 추정을 위한 실험적 연구 (Experimental Study on Flame Trajectory in Building External Walls Fire)

  • 신이철;박계원;정재군
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2016년도 춘계 학술논문 발표대회
    • /
    • pp.79-80
    • /
    • 2016
  • In the event of a fire on the outer walls of an architectural structure, through real scale experiments with the purpose of estimating the Flame Trajectory, the behavior and risks of expanded combustion to an upper architectural compartment of the Fire Plume Ejected from an Opening according to changes in the aspect ratio of the opening were examined. The results showed that the more the heat release rate of the fire source increased, the heat capacity of the Fire Plume Ejected from the Opening also increased, and for the case of heptane when compared with methanol or ethanol, the results showed a trend for a significant amount of unburned gas to remain. The results also showed that the larger the aspect ratio was, the more likely it was for the Flame Trajectory to approach the outer walls and rise up. In each of the experiment conditions, as the flame rose from the lower part of the wall to the upper part of the wall, a steady decrease was shown for the temperature distribution. Also by quantitatively analyzing the amount of unburned gas that remained, a method to estimate the temperature of the Fire Plume Ejected from an Opening for a traverse opening was implemented.

  • PDF

외벽 마감재료의 수직화재 확산 연구를 위한 실물화재 실험 (The Real Scale Fire Tests for Vertical Fire Spread Study of External Finishing Material)

  • 권오상;유용호;김흥열;김정현;민세홍
    • 한국화재소방학회논문지
    • /
    • 제26권6호
    • /
    • pp.85-91
    • /
    • 2012
  • 건축물에서 화재 시 인명과 재산의 피해를 줄이기 위해서는 초기의 화염의 확산을 억제하는 것이 우선되어야 한다. 화염의 확산을 방지하기 위한 화재확산방지 대책은 일반적으로 방화구획에서의 구조부재의 내화 성능 확보, 마감재료의 연소 성능에 따른 사용 제한 등이 있다. 마감재료의 연소 성능 판단은 화염의 확산을 판단하기 위해 가장 기초적인 화재 안전 설계이지만 국내의 연소 시험은 시편 크기의 화재 시험 방법으로 연소 성능을 판단하고 있어 샌드위치패널 등과 같은 복합재료의 연소 성능을 판단하기에는 많은 제약을 가지고 있다. 특히 외벽 마감재료의 경우 내부 마감재료에 비해 드라이비트, 알루미늄복합패널, 메탈패널 등과 같은 다양한 복합재료 등이 사용되고 있기 때문에 본 연구에서는 외벽 마감재료의 국제시험규격인 ISO 13785-2 시험방법을 통해 외벽 마감재료의 실물 화재 실험을 통해 외벽 마감재료의 수직화재 확산 특성을 판단하고자 하였다.

고층건물의 수직방향 연기거동에 미치는 발코니의 영향에 관한 실험적 연구 (An Experimental Study on the Effect of the Balcony on the Vertical Smoke Movement of the High Rise Building)

  • 양승신;김성찬;유홍선;심상훈
    • 한국안전학회지
    • /
    • 제20권1호
    • /
    • pp.42-48
    • /
    • 2005
  • The present study investigates the effect of balcony on external smoke movement of high rise building through the fire tests of the 1/10 reduced model scale using Froude scaling. A hexane pool fire is used to examine the smoke movement for various opening sizes of balcony and temperature distributions are measured by T-type thermocouples. Also, hydrogen bubble technique is applied to visualize the smoke movement near the balcony. Measured temperatures of the closed balcony is 2.5 times higher than those of the open balcony because the external smoke in case of the closed balcony rise along the vertical wall. The maximum vertical temperature of partially closed balcony is similar with fully closed balcony and mean temperature inside of balcony increases as opening size of balcony decreases. The experimental results show that the balcony space plays an important roles in preventing fire propagation and cooling of smoke layer. In order to ensure the fire safety in high rise building design, a series of systematic researches are required to examine the various type of balconies.

옥내용 비닐코드 및 고무코드의 화재확산특성 분석 (The Analysis of Fire Dispersion Characteristics of Vinyl and Rubber Cords Used Indoors)

  • 최충석;송길목;김동욱;김동우;김영석
    • 조명전기설비학회논문지
    • /
    • 제19권1호
    • /
    • pp.130-135
    • /
    • 2005
  • 일체형 코드에서는 접촉 불량, 기계적 충격 등의 부주의한 사용에 의해 전기화재가 자주발생하고 있다. 본 논문에서는 비닐코드 및 고무코드 등의 일체형 코드의 화재확산 패턴을 조사하기 위해 벽면모델을 모의하였다. 화재진행과 확산패턴은 고속카메라를 이용하여 측정하였다. 실험결과로부터, 일체형 코드의 화재패턴은 섬광, 비산 그리고 완전이탈 순으로 진행하였다. 외부화염에 의해 비닐코드가 고무코드보다 단락이 쉽게 발생하였다. 일체형 코드가 완전 이탈이 된 경우, 비닐코드는 착화에너지가 감소함에 따라 더 이상의 화재 진전은 이루어지지 않았지만, 고무코드는 연속적으로 화재가 진행하는 것을 알 수 있었다.

내, 외단열 공동주택의 축열체 위치 차이에 따른 동단위 연간 냉난방부하 비교평가 (Comparison of Annual Heating and Cooling Loads of Internally and Externally Insulated Apartment Buildings According to the Location of Thermal Mass)

  • 구보경;이병인;최두성;송승영
    • 한국태양에너지학회 논문집
    • /
    • 제30권1호
    • /
    • pp.42-49
    • /
    • 2010
  • The IIS(Internal Insulation System) is applied in most Korean apartment buildings which are the most common type of residential buildings. Consequently, there are many cases in which the layer of insulation is disconnected by the structural components at the wall-slab and wall-wall joints in the envelope. These joints become thermal bridges where the risk of heat loss increases. It is expected that the EIFS(External Insulation and Finish System) is the solution to this problem. In this study, annual heating and cooling loads of apartment buildings with IIS and EIFS were compared using Design Builder program in order to evaluate the thermal storage effect of EIFS where the concrete thermal mass is located inside of the insulation material. As results, the apartment building with EIFS could reduce annual heating and cooling loads by 2.4% and 4.1%, respectively.

골조 외부에 부착한 강재댐퍼의 성능 평가 (Capacity Evaluation of Steel Damper Attached to Outside of Frame)

  • 이현호
    • 한국건설순환자원학회논문집
    • /
    • 제5권4호
    • /
    • pp.382-388
    • /
    • 2017
  • 본 연구에서는 공공건물에 보강이 가능하도록 건물 외부에 록킹 월을 설치하고 이를 본 구조에 강재댐퍼로 연결하는 외부 보강 내진공법에 대한 기초 연구를 시행하였다. 2개의 실험체를 제작하였으며, 댐퍼 비보강 실험체는 기존 결과를 활용하였다. 포락선, 강도, 강성저하 및 에너지 소산능력을 평가한 결과, 플레이트 댐퍼를 외부 보강한 RW_P 실험체의 강도 증진이 우수한 것으로 평가되었다. 또한 S형 댐퍼를 외부 부착한 RW_S 실험체는 최대하중 이후에 완만한 포락곡선을 보여 댐퍼가 하중을 적절히 소산하는 것을 확인할 수 있었다.