• 제목/요약/키워드: External ultrasound

검색결과 113건 처리시간 0.033초

The Effect of Real-time Ultrasound Imaging Feedback during Abdominal Hollowing in Four Point Kneeling to Healthy Men

  • Park, Du-Jin
    • The Journal of Korean Physical Therapy
    • /
    • 제22권6호
    • /
    • pp.1-6
    • /
    • 2010
  • Purpose: This study investigated the effects of visual feedback during abdominal hollowing (AH) in four point kneeling position, using real-time ultrasound imaging through measurement of the changes in the thickness of transversus abdominis (TrA), internal abdominal oblique (IO), and external abdominal oblique (EO). Methods: The subjects of this study were 32 healthy males who were divided intothe experimental group of 16 subjects and the control group of 16 subjects. The real-time ultrasound feedback was applied to the experimental group while they were educated on the AH exercise in four point kneeling whereas only general education and training were given to the control group. After the training, the changes in the thickness of abdominal muscles during AH in four point kneeling were compared between the experimental group and the control group. Results: The differences of the changes in the thickness of TrA and EO between the two groups were statistically significant. Conclusion: The experimental group experienced a higher increase in the thickness of TrA than the control group while the thickness of IO and EO of the experimental.

작은관코박쥐(Murina ussuriensis)의 외부형태 및 초음파 특성에 관한 기초 연구 (External Morphology and Ultrasound Characteristics of the Ussurian Tube-nosed Bat (Murina Ussuriensis))

  • 정철운;한상훈;김성철;이화진
    • 한국환경과학회지
    • /
    • 제23권3호
    • /
    • pp.521-525
    • /
    • 2014
  • The Ussurian tube-nosed bat (Murina ussuriensis) is a registered endangered species that has not been observed in South Korea since 1960. We were able to capture three individuals of M. ussuriensis between 2011 and 2013 at Sobaeksan National Park. The discovery of this species was the first time within 50 years. To collect basic data on the M. ussuriensis, we analyzed the external morphology and ultrasound characteristics of the captured bats. The results indicated that M. ussuriensis weigh approximately 5.2 g, which is less than that of a typical small bat such as Pipistrellus abramus. The bat's wing-type ratio was determined to be 1.22 and classified as a broad and short wingspan type. The bat uses FM signals for ultrasound with a peak frequency of 92 kHz. The M. ussuriensis seems to be a forest-dwelling bat that preys on insects by maneuvering expertly within the complex mazelike structure of forests. In the future, further research on the hibernation and foraging sites of the bats is necessary to protect and monitor the species.

할로잉 운동 시 시각적 피드백 방법에 따른 복근 두께에 미치는 영향 비교 (Comparison of the Abdominal Muscle Thickness during Abdominal Hollowing Exercise According to the Visual Feedback Method)

  • 김하림;손호희
    • 대한물리의학회지
    • /
    • 제16권3호
    • /
    • pp.107-113
    • /
    • 2021
  • PURPOSE: Selective strengthening of the transverse abdominis muscle (TrA) during abdominal hollowing makes an important contribution to the stability and control of the spine. This study examined the effects of abdominal hollowing exercise (AHE) according to the visual feedback method on the external oblique, internal oblique, and transverse abdominis muscles. METHODS: Twenty healthy subjects were assigned randomly to an AHE with visual feedback from real-time ultrasound image (group A, n = 10), AHE with visual feedback with pressure biofeedback unit (group B, n = 10). Both groups underwent 20 min of AHE with visual feedback once daily, five days/week for two weeks. The changes in the muscle thickness of the TrA, internal oblique abdominal muscle (IO), and external oblique abdominal muscle (EO) were measured by ultrasonography. RESULTS: The thickness of TrA was changed significantly in both groups (p < .05). However, the lowest minimal detectable changes were achieved in Group A. The thickness of the IO and EO muscles in group A was changed significantly, but there were no significant changes in group B. CONCLUSION: Both visual feedback methods were effective for strengthening the TrA muscles selectively. Nevertheless, AHE with visual feedback using real-time ultrasound images may be more useful in trA muscle contraction.

딥러닝을 활용한 3차원 초음파 파노라마 영상 복원 (3D Ultrasound Panoramic Image Reconstruction using Deep Learning)

  • 이시열;김선호;이동언;박춘수;김민우
    • 대한의용생체공학회:의공학회지
    • /
    • 제44권4호
    • /
    • pp.255-263
    • /
    • 2023
  • Clinical ultrasound (US) is a widely used imaging modality with various clinical applications. However, capturing a large field of view often requires specialized transducers which have limitations for specific clinical scenarios. Panoramic imaging offers an alternative approach by sequentially aligning image sections acquired from freehand sweeps using a standard transducer. To reconstruct a 3D volume from these 2D sections, an external device can be employed to track the transducer's motion accurately. However, the presence of optical or electrical interferences in a clinical setting often leads to incorrect measurements from such sensors. In this paper, we propose a deep learning (DL) framework that enables the prediction of scan trajectories using only US data, eliminating the need for an external tracking device. Our approach incorporates diverse data types, including correlation volume, optical flow, B-mode images, and rawer data (IQ data). We develop a DL network capable of effectively handling these data types and introduce an attention technique to emphasize crucial local areas for precise trajectory prediction. Through extensive experimentation, we demonstrate the superiority of our proposed method over other DL-based approaches in terms of long trajectory prediction performance. Our findings highlight the potential of employing DL techniques for trajectory estimation in clinical ultrasound, offering a promising alternative for panoramic imaging.

A Randomized Comparative Study of Blind versus Ultrasound Guided Glenohumeral Joint Injection of Corticosteroids for Treatment of Shoulder Stiffness

  • Lee, Hyo-Jin;Ok, Ji-Hoon;Park, In;Bae, Sung-Ho;Kim, Sung-Eun;Shin, Dong-Jin;Kim, Yang-Soo
    • Clinics in Shoulder and Elbow
    • /
    • 제18권3호
    • /
    • pp.120-127
    • /
    • 2015
  • Background: We prospectively compared the response to blind and ultrasound-guided glenohumeral injection of corticosteroids for treatment of shoulder stiffness. Methods: A total of 77 patients with shoulder stiffness between April 2008 and March 2012 were recruited. Patients were randomized to receive either a blind (group 1, n=39) or ultrasound-guided (group 2, n=38) glenohumeral injection of 40 mg triamcinolone. The clinical outcomes and shoulder range of motion (ROM) before injection, at 3, 6, and 12 months after injection and at the last follow-up were assessed. The same rehabilitation program was applied in both groups during the follow-up period. Results: There was no significant difference in demographic data on age, sex, ROM, and symptom duration before injection between groups (p>0.05). There were no significant differences in ROM including forward flexion, external rotation at the side, external rotation at $90^{\circ}$ abduction, and internal rotation, visual analogue scale for pain and functional outcomes including American Shoulder and Elbow Surgeons score, Simple Shoulder test between the two groups at any time point (p>0.05). Conclusions: Based on the current data, the result of ultrasound-guided glenohumeral injection was not superior to that of blind injection in the treatment of shoulder stiffness. We suggest that ultrasound-guided glenohumeral injection could be performed according to the patient's compliance and the surgeon's preference. Once familiar with the non-imaging-guided glenohumeral injection, it is an efficient and reliable method for the experienced surgeon. Ultrasound could be performed according to the surgeon's preference.

초음파 영상을 이용한 교각운동 시 복부 드로잉-인 운동이 복부 근육의 두께에 미치는 영향 (The Effect of Abdominal Muscle Drawing-In Exercise During Bridge Exercise on Abdominal Muscle Thickness, using for Real-time Ultrasound Imaging)

  • 하유;이건철;배원식;조영재
    • 대한물리의학회지
    • /
    • 제8권2호
    • /
    • pp.231-238
    • /
    • 2013
  • PURPOSE: The purpose of this study is to find out the thickness variation of the superficial and deep abdominal muscles by measuring the thickness of the abdominal muscles. METHODS: 35 young, healthy adults(24 mens and 11 womens) participated in this study. The first, when only bridge exercise we had measured the thickness of their abdominal muscles by the ultrasound. The second, when the abdominal drawing-in during maintaining the bridge exercise we had measured the thickness of their abdominal muscles by the ultrasound. A pared t-test was used to determine a statistical significance for the thickness variation of the superficial and deep abdominal muscles. RESULTS: Results of before and after comparative analysis. The surperficial muscles(rectus abdominis, external obilique) statistically significantly reduced in the thickness and the deep muscle(transeverse abdominis) statistically significantly increased in the thickness. CONCLUSION: We have shown that the abdominal drawing-in exercise during maintaining the bridge exercise was effective to increase in strengthening abdominal deep muscle selectively.

고강도 집속 초음파에 의한 온도민감성 리포솜으로부터 약물 방출 (Drug Release from Thermosensitive Liposomes by High-Intensity Focused Ultrasound)

  • 전예원;조선행;한희동;신병철
    • 대한화학회지
    • /
    • 제58권6호
    • /
    • pp.575-579
    • /
    • 2014
  • 종양 조직으로 약물을 효과적으로 전달하기 위하여 리포솜의 개발이 활발이 연구되고 있다. 그러나 리포솜이 종양조직에 효과적으로 축적됨에도 불구하고, 낮은 약물 방출 때문에 리포솜의 치료 효과가 제한적이다. 따라서 우리는 외부 자극에 의하여 약물방출을 최대화 시킬 수 있는 온도민감성 리포솜을 개발하였다. 모델약물인 독소루비신은 pH 전위차 방법에 의하여 리포솜 내부에 봉입하였다. 리포솜의 입자 크기는 $142.0{\pm}6.24nm$ 이었고, 표면전하는 $-10.55{\pm}1.12mV$ 이었다. 온도민감성 리포솜으로부터 약물의 방출은 형광광도계로 측정하였으며 $42^{\circ}C$ 이상에서 5분 이내에 80% 이상의 방출률을 나타냈다. 초음파에 의해 온도민감성 리포솜으로부터 방출된 독소루비신의 세포독성은 초음파를 조사하지 않은 온도민감성 리포솜보다 월등히 우세하였다. 이번 연구에서 우리는 초음파에 의하여 온도민감성 리포솜으로부터 온도에 민감한 약물방출을 증명하였고, 이것은 외부 자극에 의한 종양조직의 약물 농도를 증가시킬 수 있는 암치료에 효과적일 것이다.

방사선사의 초음파검사 시 체감하는 직무만족도의 구조적 관계 해석 (Analysis of Structural Relationship of Job Satisfaction Levels Felt in Ultrasound Examination by Radiological Technologists)

  • 김혜진;성열훈
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제46권4호
    • /
    • pp.325-336
    • /
    • 2023
  • The purpose of this study was to analyze the structural relationship between job satisfaction levels felt during ultrasound examination of radiological technologists (RTs) using a structural equation model. The subjects were a total of 203 RTs currently working in medical institutions. The method was conducted as a survey study using a questionnaire consisting of a total of 29 questions consisting of demographic characteristics and job satisfaction levels that were self-efficacy, job competency, extrinsic compensation, and job satisfaction. The reliability was secured with the Cronbach's alpha coefficient of 0.6 or higher. For statistical analysis, a significant difference between the frequency analysis of demographic characteristics and the mean of the job satisfaction levels were performed by independent sample T-test and one-way analysis of variance (ANOVA) followed by Scheffe's post hoc test. The correlation analysis between variables was tested with Spearman's and Pearson's correlation coefficient. We analyzed the structural relationships between variables by structural equations. As a result, first, job competency and extrinsic compensation had a positive effect on job satisfaction on ultrasound examination of RTs. Second, the self-efficacy of ultrasound examination RTs showed a high correlation with job competency. Third, the job satisfaction levels showed in the order of job competency, job satisfaction, self-efficacy, and extrinsic compensation. In conclusion, this study are expected to be provided as data to identify factors that could improve job satisfaction during ultrasound examination of RTs by empirically analyzing the structural relationship of self-efficacy, job competency, and external compensation.

견부손상환자의 팔의 자세에 따른 초음파 영상을 이용한 견봉하공간 거리의 비교 (Comparison of Distance of Subacromial Space Using Ultrasonographic Measurement on Arm Positions of Shoulder Injured Patients)

  • 지은미;김선엽;박지환
    • 대한물리의학회지
    • /
    • 제6권4호
    • /
    • pp.397-406
    • /
    • 2011
  • Purpose : Recently ultrasound images has been used to measure the subacromial space with a linear measurement of the acromiohumeral distance. The purpose of this study was to comparison of distance of subacromial space using ultrasonographic measurement on arm positions of shoulder injured patients. Methods : The subjects were 30 shoulder injured patients (19 males and 11 females). Ultrasonography was performed to measure subacromial space during each shoulder resting position, $45^{\circ}$ abduction, internal rotation with $45^{\circ}$ abduction and external rotation with $45^{\circ}$ abduction. Results : Subacromial space was a significantly difference between injured arm and normal arm at shoulder resting position. At $45^{\circ}$ abduction, subacromial space was narrowing significantly between injured arm and normal arm. At external rotation with $45^{\circ}$ abduction, subacromial space were wider in normal arm than in injured arm but it was not significantly. Intra-observer reliability for ultrasonography measurement of subacromial distance was excellent (.96~.99). Conclusion : These results identified that positions of injured shoulder was related to subacromion space.

지지면과 무릎관절 각도에 따른 교각운동이 복부근육의 두께에 미치는 영향 (Effect of Bridge Exercise on the Thickness of Abdominal Muscle according to Support and Knee Angle)

  • 문달주;박재철;최석주
    • 대한물리치료과학회지
    • /
    • 제25권3호
    • /
    • pp.25-31
    • /
    • 2018
  • Background: The purpose of this study was to find out how changes in knee angles in stable and unstable support surfaces affect the muscle thickness of core muscles. Methods: The subjects of this study were 25 male adult. Each knee angle of 120, 90 and 60 degrees, they were performed bridge exercise on the stabilized surface and on the unstable support surface using TOGU, and measured the muscle thickness of the external and internal oblique muscle and the abdominal muscles through ultrasound images. Results: There was no significant difference between the thickness of the rectus abdominis and the internal oblique muscle depending on the support surface and the knee joint bending angles. However, there was a significant difference between the external oblique muscle and the transverse abdominis muscle by knee joint flexion angle. Conclusion: While the muscle thickness of the core muscle was not significantly affected by each support surface during the bridge exercise, there were significant changes in the core muscle as a result of changes in knee angle.