• Title/Summary/Keyword: External temperature

Search Result 1,494, Processing Time 0.031 seconds

Effects of Shading Rate and Method of Inside Air Temperature Change in Greenhouse (차광율 및 차광방법이 온실내부의 온도변화에 미치는 영향)

  • 이석건;이현우;김길동;이종원
    • Journal of Bio-Environment Control
    • /
    • v.10 no.2
    • /
    • pp.80-87
    • /
    • 2001
  • This study was conducted to provide basic data for the design of shading facility of greenhouse. The proper distance between external shading screen and roof surface, transmissivity of shading materials, and shading effects of external and internal shadings were analyzed. About a distance of 10 cm between inclined external shading screen and roof surface was enough to guarantee the external shading effect in the greenhouse without roof vent. The inside temperature of greenhouse installed with 85% internal shading screen was lower the maximum of 4$^{\circ}C$ and mean of 2$^{\circ}C$ than that with 55% internal shading screen in both natural ventilation and no ventilation condition. The difference of soil temperature between shading and no shading greenhouse was great, but the difference by shading rate or shading method was small. The performance of external shading for controlling inside temperature down was superior to that of the internal shading. The externally inclined shading screen parallel to the roof surface of greenhouse was more effective than the externally horizontal shading screen in controlling inside temperature of greenhouse without roof vent.

  • PDF

[Mössbauer] Spectroscopic Study of La1/3Sr2/3FeO2.96 under the External Magnetic Field (산소결핍 페롭스카이트 La1/3Sr2/3FeO2.96의 외부 자기장 하에서의 Mössbauer분광학적 연구)

  • Yoon, Sung-Hyun;Jung, Jong-Yong
    • Journal of the Korean Magnetics Society
    • /
    • v.15 no.2
    • /
    • pp.81-84
    • /
    • 2005
  • The origin for the charge disproportionation (CD) transition in polycrystalline $La_{1/3}Sr_{2/3}FeO_{2.96}$ was examined using X-ray diffraction and the external field $M\ddot{o}ssbauer$ssbauer spectroscopy. In order to see how the external magnetic field affects the CD state above its transition temperature, an external magnetic field of up to 6 T was applied either parallel or perpendicular to the $\gamma-ray$ direction with the sample temperature fixed at 225 K, which was above the CD transition temperature. Without an external magnetic field, a completely paramagnetic singlet was obtained in the temperature range of the averaged valence state above the transition temperature, which was interpreted as coming from the average valence $Fe^{3.6+}$. In the longitudinal geometry, a magnetic Zeeman with its intensity ratio 3:0:1:1:0:3 is superimposed to the central singlet. In the transverse geometry, however, the central singlet disappears and only a magnetic component with its intensity ratio 3:4:1:1:4:3 emerges. The existence of a singlet is understood as an evidence of the fast electron-transfer among Fe ions. Since the singlet still exists under the magnetic field, the application of an external field has little effect on the conduction mechanism of hopping electrons.

Observation of External Injury and Morphological Movement for Analysis of Recovery Possibility after Storage of the Juvenile Sea Cucumber, Apostichopus japonicus (돌기해삼(Apostichopus japonicus)의 보관 후 회복 가능성 파악을 위한 외상 및 형태학적 변화의 관찰)

  • KIM, Tae-Ik;SON, Maeng-Hyun;CHO, Jae-Kwon;JIN, Young-Guk
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.28 no.4
    • /
    • pp.1006-1013
    • /
    • 2016
  • The observed external injury, movement and survival rate according to storage and recovery of the juvenile sea cucumber, Apostichopus japonicus(wet weight $1.0{\pm}0.2g$). The investigated application possibility of external injury(grade I~IV) and movement variation(buccal tentacle, motion, obversion, movement) for estimate of survival rate. The survival rate was observed through the recovery after storage of the sea cucumber in various water temperature(10, 15, 20, $25^{\circ}C$) and hours(3, 6, 12, 24 hour). Grade of external injury lower in the 24 hour experiment group of $20^{\circ}C$ water temperature and 12 hour experiment group of $25^{\circ}C$ water temperature. Buccal tentacle and movement strong related survival rate and external injury. In the case of $20^{\circ}C$ water temperature, survival rate was observed decrease 24 hours experiment. $25^{\circ}C$ water temperature was high to 6 hours but 12 hours experiment group observed decrease of the survival rate. The lethal time(LT10) of the juvenile sea cucumber was 15.73 hours($20^{\circ}C$) and 5.57 hours($25^{\circ}C$). The results of this study provided various measurement method of survival rate according to transportation of the juvenile sea cucumber for release.

Control Performance Investigation of Piezoelectric Actuators under Variation of External Heat Environment (외부 열적 환경 변화에 따른 압전작동기 제어성능 열화 고찰)

  • Han, Young-Min;Moon, Byung Koo;Choi, Seung-Bok
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.10
    • /
    • pp.707-713
    • /
    • 2015
  • This paper proposes experimental results for control performance deterioration of a piezoelectric actuator under high temperature conditions due to external heat environment. In this work, a heat environment from 30 ℃ to 190 ℃ is established by a heat chamber which is capable of high temperature of heat environment. Inside the heat chamber, an experimental apparatus consisting of the stack type of piezoelectric actuator, laser sensor, gap sensor and temperature sensor is established. After evaluating temperature dependent blocking force, displacement and time response of a piezoelectric actuator inside the heat chamber, tracking control performances are evaluated under various temperature conditions via proportional-integral-derivative(PID) feedback controller. The desired position trajectory has a sinusoidal wave form with a fixed frequency. Control performances are experimentally evaluated at both room temperature and high temperature and presented in time domain.

A Clinical Research of Atopic Dermatitis treated by Yeongyuseungmatang in cosmetics (연교승마탕(連翹升麻湯)이 함유된 한방화장품이 아토피 피부염에 미치는 임상 연구)

  • Kim, Sung-Ho;Yun, Dae-Chul;Kim, Hee-Taek;Ho, Dong-Su;Yoon, Kyung-Sup
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.21 no.2
    • /
    • pp.126-141
    • /
    • 2008
  • Objective : This clinical research was conducted to test patients with Atopic Dermatitis by external application with Yeongyuseungmatang in cosmetics. Methods : We gave scores to 33 patients who visited the Dept. of Oriental Medical Opthalmology & Otolaryngology & Dermatology of Semyung Jecheon Oriental Medical Hospital from April 17th, 2008 to June 12th. Seventeen patients were treated with Yeongyuseungmatang(Experimental group) and sixteen patients were treated with Atopico skin care cream(Control group) for 4weeks. We observed change of total IgE, eosinophil count, Skin Temperature, Transepidermal Water Loss(TEWL), Skin Hydration and Skin pH. Also Clinic Index of Atopic Dermatitis(SCORAD Index) and global assesment of efficacy were used to evaluate the effects of Yeongyuseungmatang. Statistical analysis was performed by using frequency analysis and descriptive analysis. Statistical significance was achieved if the probability was less than 5%(p<0.05). Results : 1. After 4 weeks of external application treatment, SCORAD Index in Yeongyuseungmatang was significant statistically decreased compared with control group. 2. After 4 weeks of external application treatment, eosinophil count in Yeongyuseungmatang was significant statistically decreased compared with control group but total IgE was very increased both Yeongyuseungmatang and control group. 3. Statistically, Yeongyuseungmatang and control group didn't showed significant effect on Skin Temperature was measured by Thermometer SM815. 4. Transepidermal Water Loss(TEWL) in Yeongyuseungmatang was significant statistically decreased compared with control group measured by Tewameter TM300. 5. Skin Hydration in Yeongyuseungmatang was significant statistically increased compared with control group measured by Corneometer CM825. 6. Statistically, Yeongyuseungmatang and control group didn't showed significant effect on Skin pH was measured by Skin-pH-Meter PH905. 7. After 4 weeks of external application treatment, Yeongyuseungmatang showed significant effect on global assesment of efficacy. Conclusion : Considering the above results, we can speculate that cosmetics with Yeongyuseungmatang has some therapeutical effects in mitigating the symptoms of atopic dermatitis.

  • PDF

Study of Cure Behavior of the External and Internal of Composite Parts (경화공정에 따른 복합재 부품 외부와 내부의 경화 거동 차이에 대한 연구)

  • Hyun, Dong Keun;Lee, Dong Seung;Shin, Do Hoon;Kim, Ji Hoon
    • Composites Research
    • /
    • v.33 no.5
    • /
    • pp.302-308
    • /
    • 2020
  • We measured the thermal conductivity of composite materials manufactured by the autoclave and vacuum bag only processes and predicted the cure behavior of the external and internal of composite parts with a cure kinetics model. The temperature difference between the external and internal depends on the processes because of the change of thermal conductivity. In the autoclave process, the temperature and cure behavior of the internal were similar to those of the external because of the high thermal conductivity. However, the temperature of the internal of the vacuum bag only process was different from that of the external. The difference can influence the part quality and evacuation of air. Compression tests were performed to find the mechanical property using 0° unidirectional specimens. The composite of the vacuum bag only process was found to have a lower compressive strength than that of the autoclave process.

Performance Characteristics with Various Fuel Composition and Temperature for an External Type Fuel Pump in LPLi System (LPLi 시스템에서 외장형 펌프의 연료조성 및 온도에 따른 성능특성 연구)

  • Nam, Deok-Woo;Yoon, Jun-Kyu;Lim, Jong-Han
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.5
    • /
    • pp.566-575
    • /
    • 2011
  • Since LPG (Liquefied petroleum gas) fuel supply system has an advantage of low emission characteristics, many studies have been conducted. In spite of the advantage of LPG supply system, a higher vapor pressure and lower viscosity than diesel or gasoline fuel may cause unstable running of fuel pump by the deterioration in lubrication performance and chemical reaction with rubber parts than that of diesel and gasoline fuel. Therefore its physical properties can cause the deterioration of durability. In this research, we developed an external type LPG pump which has the advantage of the price competitiveness and the convenient maintenance for LPLi system. The experiments were carried out in order to assess characteristics of the external type fuel pump at different fuel composition and temperature. As a result, there aren't any differences between internal and external type pump performance. It is observed that the same level of efficiency was maintained for both pumps as flow rate was increased with higher fuel temperature and more contents of propane in the fuel. And the pressure difference in LPLi system is maintained at constant with the various fuel compositions and temperatures due to their own characteristics of fuel supply system.

Effect of Acupuncture and High Frequency Therapy Applied to the Region Branching to the External Carotid Artery on Reduction of Facial Edema in Patients with Sequelae of Peripheral Facial Palsy: A Case Report (말초성 안면마비 후유증 환자에서 침 치료와 바깥목동맥으로의 분지 영역에 시행한 고주파 병행 치료의 안면부종 감소 효과: 증례보고)

  • An, Sunjoo;Choi, Seonghwan;Kang, Shinwoo;Park, Seohyun;Keum, Dongho
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.30 no.4
    • /
    • pp.233-241
    • /
    • 2020
  • This study was performed to evaluate the effect of high frequency therapy applied to the region branching to the external carotid artery for peripheral facial paralysis sequelae. A patient suffering with facial edema due to facial paralysis sequelae had been treated with acupuncture, high frequency therapy on the branch area to the external carotid artery for 7 weeks. The evaluation of clinical outcome was done by degree of swelling by measuring the distance of the face and skin temperature of face through digital infrared thermographic imaging. After treatment, the patient's degree of swelling and the temperature difference between the affected side and normal side was decreased. In addition, the temperature was changed in the entire facial area as well as the treatment point of high frequency therapy. This result shows that acupuncture combined with high frequency therapy at the region branching to the external carotid artery could be an effective way to improve facial blood flow, although further clinical studies will be needed.

Design of a Concrete Mix Considering Curing Temperature and Delay Time in Concrete Placement (현장 콘크리트 타설시 양생온도와 대기시간을 고려한 배합설계 결정)

  • Moon, Sungwoo;Lee, Seong-Haeng;Choi, Hyun-Uk
    • Korean Journal of Construction Engineering and Management
    • /
    • v.20 no.1
    • /
    • pp.133-140
    • /
    • 2019
  • The concrete mix should be designed and produced to reflect the specific site conditions during concrete placement. That is, the concrete mix design should be planned considering temperatures, work environments, pouring methods, etc. The objective of this research is to understand the external factors of curing temperature and delay time that influence concrete strengths during pouring work, and provide concrete mix design that can be most robust to the effects of external factors. The Taguchi's robust method is used in preparing the concrete mix design to achieve the research objective. In a case study, an indoor concrete test was performed to find the optimal combination of concrete mixes with external factors of curing temperature and delay time. Concrete test cylinders were made to test concrete strengths given different external factors. The study results showed that the optimal performance of concrete strength can be achieved by applying the robust method when preparing a concrete mix design.

Dynamic Response Analysis of Rotating Functionally Graded Thin-Walled Blades Exposed to Steady Temperature and External Excitation (고온에서 외부 가진력을 받는 회전하는 경사기능 박판 블레이드의 동적응답 해석)

  • Oh, B.Y.;Na, Sung-Soo
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.643-648
    • /
    • 2004
  • This paper is dedicated to the thermoelastic modeling and dynamic response of the rotating blades made of functionally graded ceramic-metal based materials. The blades modeled as non-uniform thin walled beams fixed at the hub with various selected values of setting angles and pre-twisted angles. In this study, the blade is rotating with a constant angular velocity and exposed to a steady temperature field as well as external excitation. Moreover, the effect of the temperature gradient through the blade thickness is considered. Material properties are graded in the thickness direction of the blade according to the volume fraction power law distribution. The numerical results highlight the effects of the volume fraction, temperature gradient, taper ratio, setting angle and pre-twisted angle on the dynamic response of bending-bending coupled beam characteristics are provided for the case of a biconvex cross section and pertinent conclusions are outlined.

  • PDF