• 제목/요약/키워드: External temperature

검색결과 1,492건 처리시간 0.029초

원통형 용기의 비정상온도해석 (Analysis of unsteady temperature distribution in a cylinder for rifle barrel disign)

  • 조성환;전운학;이흥주
    • 대한기계학회논문집
    • /
    • 제3권4호
    • /
    • pp.173-180
    • /
    • 1979
  • Temperature distriburion in a hollow chlinder has been analyzed mathematically. Unsteady condition considered assumed a constant heat flux input from the inside. The results are compared with experimental results of surface temperature rise of a gun barrel during continuous firing. Their agreements are acceptable. Effects of various dimensionless parameters on the surface temperature rise are discussed. For small Biot numbers, the external survface temperature approaches more rapidly to the steady temperature. Temperature difference between internal and external surfaces becomes greater for small Biot number. Steady solution assumed that the gas temperature inside the cylinder varies periodically. Relative amplitude and phase angles between the gas temperature and the internal or external surface temperature are obtained. Phase angles become smaller for large radiancy of gas temperature variation, small external Biot number, or large internal biot number. Relative amplitudes become samller as radiancy of gas temperature variation and internal Biot number become smaller. or external Biot number becomes larger. The solution obtained in this paper can be applied to gun barrels, heat pipes used in heat excangers, and reciprocation engines.

Temperature and Electric Field Effect on Proton Transfer in Adenine-thymine

  • Zhang, Guiqing;Xie, Shijie
    • Bulletin of the Korean Chemical Society
    • /
    • 제35권12호
    • /
    • pp.3532-3534
    • /
    • 2014
  • In theoretical simulations of proton transfer in DNA, environmental factors nearly have not been considered. In our calculations, using QM/MM method on the basis of CP2K, proton transfer on adenine-thymine base pair is studied in water, at wide scope temperature, and under the external electric field. Our results indicate that the external electric field induces the proton transfer at room temperature, and its intensity and temperature have some effect on hole localization and proton transfer.

인듐틴옥사이드와 몰리브데늄을 이용한 외부 기준 저항이 필요 없는 온도센서 (Temperature sensor without reference resistor by indium tin oxide and molybdenum)

  • 전호식;배병성
    • 센서학회지
    • /
    • 제19권6호
    • /
    • pp.483-489
    • /
    • 2010
  • Display quality depends on panel temperatures. To compensate it, temperature sensor was integrated on the panel. The conventional temperature sensor integrated on the panel needs external reference resistor. Since the resistance of external resistor can vary according to the variation of the environment temperature, the conventional temperature sensor can make error in temperature sensing. The environmental temperatures can change by the back light unit, driving circuits or chips. In this paper, we proposed a integrated temperature sensor on display panel which does not need external reference resister. Instead of external reference resistor, we used two materials which have different temperature coefficient in resistivity. They are connected serially and the output voltage was measured at the point of connection with the applied voltage to both ends. The proposed sensor was fabricated with indium tin oxide(ITO), and Mo metal electrode temperature sensor which were connected serially. We verified the temperature senor by the measurements of sensitivity, lineality, hysteresis, repeatability, stability, and accuracy.

차광 방법에 따른 온실내부의 온도 변화(농업시설) (Variations of the Inside Temperature of Greenhouse According to Shading Methods)

  • 이현우;이석건;김길동;이종원
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2000년도 학술발표회 발표논문집
    • /
    • pp.321-326
    • /
    • 2000
  • This study was performed to analyze the variation of inside temperature of greenhouse according to shading methods. We used two shading method of external and internal method. The shading effect of external screen was superior to internal screen. Soil temperature of greenhouse without screen was higher than outside soil temperature, but the value of greenhouse with internal and external screen was lower than outside.

  • PDF

Design of Tissue-Transfer Container Using Thermoelectric Element Module

  • Park, Yong Pil;Cheon, Min-Woo
    • Transactions on Electrical and Electronic Materials
    • /
    • 제18권2호
    • /
    • pp.66-69
    • /
    • 2017
  • The internal temperature of human-tissue transfers must be steadily maintained regardless of the external environmental changes. An ice pack and dry ice are the coolants for the transfer containers for which heat-insulating materials such as EPP (expended polypeopylene and EPS (expended polystrene) are used; however, changes of the external temperature/pressure and the melting of the coolants that is due to a long carriage result in changes of the internal temperature, and this makes it difficult to maintain the temperature. Accordingly, the thermoelectric element was used to design/manufacture a transfer container to maintain the internal temperature regardless of the external environmental changes. As a result of the measurement of the changes of the internal temperatures of the manufactured thermoelectric-element container and the EPS container over time, the internal temperature of the EPS container was increased, whereas the internal temperature of the thermoelectric-element container was maintained. The temperature of the distilled water that was poured into the containers indicated a pattern identical to that of the internal temperature.

애주 연소 과정에서 발생하는 애주의 표면 및 중심부의 온도변화 특성 연구 (A Comparative Study of External & Central Temperature Characteristics during the Moxibustion Period)

  • 홍덕;권오상;김영진;김유리;김재효;안성훈;손인철
    • Korean Journal of Acupuncture
    • /
    • 제27권3호
    • /
    • pp.47-56
    • /
    • 2010
  • Objectives : The moxibustion is the method using the heat stimulation done by attached and burned a moxa on a healing point or acupuncture point with chemical stimulation of a resin made from burning them. The purpose of this study is to find the physical and thermal characteristics of moxibustion in order to standardize the moxa therapy method. Methods : In this study, the thermal changes were observed by means of a testo 845 device, which is an infra-red thermometer to measure the thermal changes. Results & Conclusions : 1. The thermal changes on the external surface of moxibustion did not depend on the weight of the moxa; the external surface temperature was about $500^{\circ}C$. 2. The central thermal changes depend on the weight of moxa; the central temperatures ranged from $500^{\circ}C$ to $700^{\circ}C$. 3. The burning duration of moxibustion depend on the weight of moxa but that of external surface temperature did not depend on the weight of moxa in high degree : about $400^{\circ}C$. 4. The integral values of central and external temperature curves were proportional to the weight of moxa; that is central temperature curves were higher than that of external.

A new model for transient heat transfer model on external steel elements

  • Chica, J.A.;Morente, F.
    • Steel and Composite Structures
    • /
    • 제8권3호
    • /
    • pp.201-216
    • /
    • 2008
  • The Eurocode system provides limited information regarding the structural fire design of external steel structures. Eurocode 1 provides thermal action for external member but only in steady-state conditions. On the other hand, Eurocode 3 provides a methodology to determine heat transfer to external steelwork, but there is no distinction in cross section shapes and, in addition, the calculated temperature distribution is assumed to be uniform in the cross section. This paper presents the results of a research carried out to develop a new transient heat transfer model for external steel elements to improve the current approach of the Eurocodes. This research was carried out as part of the project EXFIRE "Development of design rules for the fire behaviour of external steel structures", funded by the European Research Programme of the Research Fund for Coal and Steel (RFCS).

기후변화 대응 건축물 기화냉각시스템 적용에 따른 외부 열환경 변화 연구 (Changes in the External Heat Environment of Building Evaporative Cooling Systems in Response to Climate Change)

  • 윤용한;권기욱
    • 한국환경과학회지
    • /
    • 제27권12호
    • /
    • pp.1261-1269
    • /
    • 2018
  • The purpose of this study was to investigate changes in the external thermal environment, following the application of evaporative cooling systems in buildings, in response to climate change. In order to verify changes in the external thermal environment, a T-test was performed on the microclimate, Thermal Comfort Index (TCI), and building surface temperature. Differences in microclimate, following the application of the evaporative cooling system in the building, were significant in terms of temperature and relative humidity. In particular, temperature decreased by more than 7% when the evaporative cooling system was applied. According to the results of the Thermal Comfort Index analysis, the Wet-Bulb Globe Temperature (WBGT) was below the limit of outdoor activities, indicating that outdoor activities were possible. The Universal Thermal Climate Index (UTCI) values were within the very strong heat stress range when the evaporative cooling system was not applied, When the system was applied, the UTCI values were within the strong heat stress range, indicating that they were lowered by one level. The building surface temperature decreased by ~10% or more when the evaporative cooling system was applied, compared to when it was not applied. Finally, the outside surface temperature of the building decreased by ~12% or more when the system was applied, compared to when it was not applied. We conclude that the energy saving effect of the building was significant.

넙치(Paralichthys olivaceus) 산소 소비율에 미치는 Pop-up Satellite Archival Tag (PSAT) 체외 부착과 수온의 영향 (External Attachment of Pop-up Satellite Archival Tag (PSAT) and Water Temperature Affect Oxygen Consumption Rate of the Olive Flounder Paralichthys olivaceus)

  • 이근수;강필준;박혜미;오승용
    • 한국수산과학회지
    • /
    • 제56권5호
    • /
    • pp.660-666
    • /
    • 2023
  • This study aimed to examine the effect of external pop-up satellite archival tags (PSATs) attachment and water temperature on the oxygen consumption rate (OCR) of the olive flounder (mean body weight 2281.7 g). The OCRs of fish were measured under conditions of three different water temperature conditions (15, 20, and 25℃) and two different tagging methods [non-tagging, control; bio-logger external attachment with a miniature PSAT (dummy mrPAT), BEA] using a closed flow-through respirometer. The OCRs of fish linearly increased with the increase in water temperature in both the control and BEA (P<0.001); however, the OCRs of BEA were approximately 1.8-1.9 times lower than those of the control at each water temperature (P<0.001). The Q10 values of the control and BEA were the highest in the water temperature range of 15 to 20℃, but sensitivity to water temperature changes was higher in BEA than in the control. The metabolic energy loss rate (MEL) of fish increased with increasing water temperature regardless of external tagging, but the MEL of the control was higher than that of BEA (P<0.001). These results demonstrate that OCR, thermal sensitivity, and energy expenditure are all affected in adult olive flounder with external PSAT attachment.

외부 유동을 고려한 1.2[kW] BLDC 모터의 열 전달 해석 (The Heat Transfer Analysis of 1.2[kW] BLDC Motor on the Condition of the External Flow)

  • 황하영;정태욱;이동연;황평;심재술
    • 조명전기설비학회논문지
    • /
    • 제26권2호
    • /
    • pp.27-33
    • /
    • 2012
  • In this paper, we researched the heat transfer analysis of 1.2[kW] BLDC motor on the condition of the external flow. The BLDC motor is fallen under influence of some heat generated by rotationg motor speed and it changes the life and confidence of motor. The heat makes to reduce the life of insulation and the magnetization. So motor can't make own performance. Therefore we calculated the losses about number of revolutions of motor. And then, we analyzed the heat transfer of BLDC motor by using the results when a fan attached to motor makes the external flow or not. The results showed that the temperature of motor increased constant values irrespective of external air temperature. The temperature of motor decreased very lower values than prior researches when the fan makes the external flow. In this method we can analyze the performance, losses and heat transfer of motor applied in the many industries.