• Title/Summary/Keyword: External quality control

Search Result 248, Processing Time 0.022 seconds

The Correlations among the Categorized Quality Cost Factors on Small & Medium-sized Enterprises (국내 중소 제조기업의 품질비용 행태에 관한 실증 연구)

  • Koo, Il-Seob;Lee, Sang-Choon;Jang, Kwang-Soon;Kim, Yong-Bum
    • Journal of the Korea Safety Management & Science
    • /
    • v.13 no.2
    • /
    • pp.185-193
    • /
    • 2011
  • The successful and sustainable growth of SMEs depends on their ability of strengthen their competitiveness in quality and cost and service more than anything else as a fundamental of operation. Among these key competitive factors of SMEs, quality is the most critical factor in manufacturing business fields. There are many different ways to improve the quality performance but it needs proper management decision to choose the best way what can maximize outputs with minimum inputs. And it needs effective measurement methods and some indicators to analysis the quality performance properly. The quality cost is one of the simplest key indicators to measure the quality performance and the effectiveness of quality related management decisions. In this study, through survey on local SMEs, we found that their average annual quality cost ratio versus turnover - total amount of annual quality cost divided by annual turnover - is around 3.69% excluded some SME's performances what have different quality control measures with others. And we found some results what corresponded with the early studies on the correlations between those categorized quality costs factors and some discrepancies between some of the literature model and the early case study results as follows. There were negative correlations between the Prevention costs and the External failure costs, and the Appraisal costs and the External failure costs, and there was positive correlation between the Appraisal costs and Internal failure costs same as early studies. But, we couldn't found any strong negative correlations between the Cost of control - Prevention costs & Appraisal costs - and the Cost of Failure of control - Internal & External failure costs -.

A Study on the Establishment of Acceptable Range for Internal Quality Control of Radioimmunoassay (핵의학 검체검사 내부정도관리 허용범위 설정에 관한 고찰)

  • Young Ji, LEE;So Young, LEE;Sun Ho, LEE
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.26 no.2
    • /
    • pp.43-47
    • /
    • 2022
  • Purpose Radioimmunoassay implement quality control by systematizing the internal quality control system for quality assurance of test results. This study aims to contribute to the quality assurance of radioimmunoassay results and to implement systematic quality control by measuring the average CV of internal quality control and external quality control by plenty of institutions for reference when setting the laboratory's own acceptable range. Materials and Methods We measured the average CV of internal quality control and the bounce rate of more than 10.0% for a total of 42 items from October 2020 to December 2021. According to the CV result, we classified and compared the upper group (5.0% or less), the middle group (5.0~10.0%) and the lower group (10.0% or more). The bounce rate of 10.0% or more was compared by classifying the item of five or more institutions into tumor markers, thyroid hormones and other hormones. The average CV was measured by the overall average and standard deviation of the external quality control results for 28 items from the first quarter to the fourth quarter of 2021. In addition, the average CV was measured by the overall average and standard deviation of the proficiency results between institutions for 13 items in the first half and the second half of 2021. The average CV of internal quality control and external quality control was compared by item so we compared and analyzed the items that implement well to quality control and the items that require attention to quality control. Results As a result of measuring the precision average of internal quality control for 42 items of six institutions, the top group (5.0% or less) are Ferritin, HGH, SHBG, and 25-OH-VitD, while the bottom group (≤10.0%) are cortisol, ATA, AMA, renin, and estradiol. When comparing more than 10.0% bounce rate of CV for tumor markers, CA-125 (6.7%), CA-19-9 (9.8%) implemented well, while SCC-Ag (24.3%), CA-15-3 (26.7%) were among the items that require attention to control. As a result of comparing the bounce rate of more than 10.0% of CV for thyroid hormones examination, free T4 (2.1%), T3 (9.3%) showed excellent performance and AMA (39.6%), ATA (51.6%) required attention to control. When comparing the bounce rate of 10.0% or more of CV for other hormones, IGF-1 (8.8%), FSH (9.1%), prolactin (9.2%) showed excellent performance, however estradiol (37.3%), testosterone (37.7%), cortisol (44.4%) required attention to control. As a result of measuring the average CV of the whole institutions participating at external quality control for 28 items, HGH and SCC-Ag were included in the top group (≤10.0%), however ATA, estradiol, TSI, and thyroglobulin included in bottom group (≥30.0%). Conclusion As a result of evaluating 42 items of six institutions, the average CV was 3.7~12.2% showing a 3.3 times difference between the upper group and the lower group. Cortisol, ATA, AMA, Renin and estradiol tests with high CV will require continuous improvement activities to improve precision. In addition, we measured and compared the overall average CV of the internal quality control, the external quality control and the proficiency between institutions participating of six institutions for 41 items excluding HBs-Ab. As a result, ATA, AMA, Renin and estradiol belong to the same subgroup so we require attention to control and consider setting a higher acceptable range. It is recommended to set and control the acceptable range standard of internal quality control CV in consideration of many things in the laboratory due to the different reagents and instruments, and the results vary depending on the test's proficiency and quality control materials. It is thought that the accuracy and reliability of radioimmunoassay results can be improved if systematic quality control is implemented based on the set acceptable range.

Quality Control of Pharmacopuncture: A Comparative Study of Good Manufacturing Practice and External Herbal Dispensary Standards

  • Han, Ji-Eun;Park, Minjung;An, Tteul-E-Bom;Park, Jong-Hyun;Oh, Danny;Kim, Kyeong Han;Sung, Soo-Hyun
    • Journal of Pharmacopuncture
    • /
    • v.24 no.2
    • /
    • pp.59-67
    • /
    • 2021
  • Objectives: We aimed to compare the external herbal dispensary (EHD) evaluation criteria for pharmacopuncture and the Korea Good Manufacturing Practice (KGMP) sterile medicine standards to contribute to the establishment of quality control criteria for pharmacopuncture. Methods: We obtained the KGMP standards from the Ministry of Food and Drug Safety and the pharmacopuncture certification criteria from the Ministry of Health and Welfare of South Korea. The EHD evaluation items were classified into three categories: facilities, quality control, and validation. The evaluation items were compared with the KGMP sterile medicine criteria to determine their conformance with each other, followed by a discussion among the committee of six experts and their consensus to suggest the items to complement the EHD evaluation criteria. Results: Among the KGMP sterile medicine criteria, 44 were related to the management of the facilities, and 32 pharmacopuncture evaluation items corresponded to these KGMP items (66.7%). Fifty-eight KGMP criteria were related to quality management, and 42 pharmacopuncture evaluation items corresponded to these KGMP items (72.4%). Twentyfive KGMP sterile medicine criteria were related to validation, and 11 pharmacopuncture evaluation items corresponded to these KGMP items (44.0%). Sixteen items under the pharmacopuncture EHD criteria corresponded to the KGMP sterile medicine criteria based on the consent of the experts. Among these, 4 were related to facility management, 6 were related to quality control, and 6 were related to validation. Conclusion: For the safety and quality control of pharmacopuncture, there is a need to select the criteria for the mandatory items among the proposed pharmacopuncture-EHD criteria laws and systems to ensure that the pharmacopuncture materials are produced under the pharmacopuncture-EHD in compliance with the relevant requirements. More studies are needed to secure the safety level of pharmacopuncture materials corresponding to that of conventional medicine.

Adaptive Control of Denitrification by the Extended Kalman Filter in a Sequencing Batch Reactor (확장형칼만필터에 의한 연속회분식반응조의 탈질 적응제어)

  • Kim, Dong Han
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.6
    • /
    • pp.829-836
    • /
    • 2006
  • The reaction rate of denitrification is primarily affected by the utilization of organics that are usually limited in the anoxic period in a sequencing batch reactor. It is necessary to add an extemal carbon source for sufficient denitrification. An adaptive model of state-space based on the extended Kalman filter is applied to manipulate the dosage rate of extemal carbon automatically. Control strategies for denitrification have been studied to improve control performance through simulations. The normal control strategy of the constant set-point results in the overdosage of external carbon and deterioration of water quality. To prevent the overdosage of external carbon, improved control strategies such as the constrained control action, variable set-point, and variable set-point after dissolved oxygen depletion are required. More stable control is obtained through the application of the variable set-point after dissolved oxygen depletion. The converging value of the estimated denitrification coefficient reflects conditions in the reactor.

A Study of the Subjective Quality of Life, and Locus of Control of Caregiver Trainees (요양보호사 교육생의 주관적 삶의 질과 통제위 성격에 관한 조사연구)

  • Chung, Yeo-Sook
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.14 no.1
    • /
    • pp.117-126
    • /
    • 2008
  • Purpose: The aim of this study was to research caregiver trainees, and to understand the degree of subjective quality of life and internal and external locus control, and to examine the relationships between these variables. Method: The subjects of the research were 348 trainees at a Jeonju city caregiver training center. The subjective quality of life and the characteristics of locus control were used as measuring tools. The collected data was analyzed by the SAS 9.1 program. Result: The degree of subjective quality of life was significantly different according to the general characteristics of age (F=2.83, p=0.02), marital status (F=3.34, p=0.01), and willingness to work (F=3.94, p=0.05). The degree of internal locus control was significantly different according to the general characteristic of marital status (F=3.0 p=0.01). External locus control was significantly different according to the general characteristics of age (F=9.77, p=0.00), occupation (F=2.91, p=0.01), educational level (F=9.65, p=0.00), monthly income (F=3.81, p=0.00), educational institution (F=2.06, p=0.04), educational experience (F=4.15, p=0.00), and subjects willingness to work (t=8.71, p=0.00). A significant correlation was identified between the subjective quality of life and internal locus control (r=0.23, p=0.0001). Conclusion: A significant correlation was shown between subjective quality of life and internal locus control of the caregiver trainees.

Effects of Supplementing Organic Citrus in Making Rice Straw Silage (볏짚사일리지 제조를 위한 유기감귤 첨가효과)

  • Ahn, Jong-Ho
    • Korean Journal of Organic Agriculture
    • /
    • v.15 no.3
    • /
    • pp.309-318
    • /
    • 2007
  • The effects of supplementation of organic citrus on the quality of rice straw silage was investigated in this study. The aim of the study was to improve the quality of rice straw silage using agricultural by-products and therefore to secure the good quality forage sources. Firstly, looking at chemical composition of citrus added rice straw silage, crude protein content appeared improved with the addition of citrus to rice straw silage compared to control while NDF and ADF contents decreased. pH of the silages were different between control(4.39) and treatments$(3.47\sim3.53)$. Lactic acid content was higher in citrus added silage(4.87mM) than in control (3.65mM). External quality of the silages was also better in citrus added silage when citrus added at the equal ratio with rice straw(1 : 1). This trend was the same as with pH and lactic acid content. Propionate was significantly higher in citrus addd silage but butyrate was significantly lower. DM and NDF disappearance rates in the rumen were highest when citrus added at the equal ratio with rice straw(1:1). In conclusion, supplementation of citrus to rice straw silage with equal ratio contributed the best to the improvement of the quality of silage and it may have been due mainly to abundant content of non-structural carbohydrate in citrus.

  • PDF

Determination of Quality Cost Policy under Multiple Assignable Causes (다중이상원인하의 경제적 품질비용 정책결정)

  • 김계완;김용필;박지연;윤덕균
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.26 no.1
    • /
    • pp.7-16
    • /
    • 2003
  • At present, company has to produce a product that consumer like with a competitive price, a good quality, and a fitting time to supply. Process control and quality control are very important to supply with a product uniformly and inexpensively. Process control is given much weight in the quality control in manufacturing system. Statistical process controls(SPC) that are used in process generally have major impact on manufacturing, product design activities, and process development potentially. Control charts in statistical process control method can be interpreted the data from quality characteristics in production process and discriminated between chance variation and assignable variation in process. In addition, control chart can be used to monitor the process output and detect when changes in the inputs are required to bring the process back to an in-control state. The models that relate the influential inputs to process outputs help determine the nature and magnitude of the adjustments required. In this paper, the characteristic of product quality is monitored by control chart during the machining process and construction of quality control cycle is considered to divide into two types in this case that different assignable causes lead to shifts having different magnitudes. Then we are intended to find a process shift magnitude which has economical quality cost policy and are considered to quality cost functions to find a process shift magnitude. Those costs are categorized into the well-known categories of prevention, appraisal, and internal failure and external failure. This paper ends with numerical examples that demonstrate the usefulness of the model.

Determination of Quality Cost Policy under the Multiple Assignable Causes (다중이상원인하의 경제적 품질비용 정책결정)

  • Kim Kyewan;Park Ji Yeon;Yun Deok Kyun
    • Proceedings of the Society of Korea Industrial and System Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.1-8
    • /
    • 2002
  • At present, company has to produce a product that consumer like with a competitive price, a good quality, and a fitting time to supply. Process control and qualify control are very important to supply with a product uniformly and inexpensively In this paper, the characteristic of product quality is monitored by control chart during the machining process and construction of quality control cycle is considered to divide into two types in this case that different assignable causes lead to shifts having different magnitudes. Then we are intended to find a process shift magnitude which has economical quality cost policy and are considered to quality cost functions to find a process shift magnitude. Those costs are categorized into the well-known categories of prevention, appraisal, and internal failure and external failure. This paper ends with numerical examples that demonstrate the usefulness of the model.

  • PDF

A study of external applications for cancer treatment (외부법의 종양치료활용에 대한 고찰)

  • Lee, Yong-Yeon;Song, Kee-Cheol;Choi, Byung-Lyul;Seo, Sang-Hoon;Choi, Woo-Jin;Cho, Jung-Hyo;Lee, Yeon-Weol;Son, Chang-Gue;Cho, Chong-Kwan;Yoo, Hwa-Seung
    • The Journal of Internal Korean Medicine
    • /
    • v.22 no.4
    • /
    • pp.659-667
    • /
    • 2001
  • Objectives: The purpose of this study was to explore some new therapies to control clinical symptoms of patients with terminal cancer by using external applications. Methods: We investigated some literatures on the external applications for cancer patients and made diagrams. Results: The results are summarized as follows. External applications are one of the traditional oriental medical methods and these are effective for pain control, ascites & pleural effusion and palpitable mass. It has some characteristics which are simple, safe and popular, but we must pay attention carefully to allergic reaction and toxicity in using external applications. The therapeutic portion of external applications are decided by discipline of syndrome and disease differentiation, and the prescriptions are composed of antitumor herb medicines. Conclusions: From the above results, it is expected that external applications are useful to improve clinical symptoms and quality of life(QOL) for patients with terminal cancer who cannot intake foods or medicines.

  • PDF

Quality Control of Diagnostic X-ray Units for Animal Hospital (동물병원의 방사선발생장치 정도관리에 대한 연구)

  • Kim, Sang-Woo;Lee, Ji-Hoon;Park, Yei-Seul;Rhim, Jea-Dong;Seoung, Youl-Hun
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2010.04a
    • /
    • pp.231-237
    • /
    • 2010
  • The purpose of this study was to investigate the actual conditions of radiation safety supervision in animal clinics using quality assurance (QA) and quality control (QC) of diagnostic X-ray units. The surveys for QA/QC, equipment condition, and safety supervision were carried out in 18 animal clinics randomly. The QA/QC included reproducibility of dose exposure, kVp, mAs, collimator accuracy test, collimator luminance test, X-ray view box luminance test, grounding system equipment test and external leakage current test. As a result, 44.44% of reproducibility of dose exposure was proper, 81. 25% of kVp test was good, and 100% of mAs test was appropriate. Also, 66.66% of collimator accuracy test was proper, 61.11% of collimator luminance test was good, 53.13% of X-ray view box luminance test was suitable. In addition, only 5.55% of grounding system equipment and ground resistance was proper, 63.64% of external leakage current test was appropriate in grounding system equipment test.

  • PDF