• 제목/요약/키워드: External ac magnetic field

검색결과 44건 처리시간 0.026초

Crystal growth from melt in combined heater-magnet modules

  • Rudolph, P.;Czupalla, M.;Dropka, N.;Frank-Rotsch, Ch.;KieBling, F.M.;Klein, O.;Lux, B.;Miller, W.;Rehse, U.;Root, O.
    • 한국결정성장학회지
    • /
    • 제19권5호
    • /
    • pp.215-222
    • /
    • 2009
  • Many concepts of external magnetic field applications in crystal growth processes have been developed to control melt convection, impurity content and growing interface shape. Especially, travelling magnetic fields (TMF) are of certain advantages. However, strong shielding effects appear when the TMF coils are placed outside the growth vessel. To achieve a solution of industrial relevance within the framework of the $KRISTMAG^{(R)}$ project inner heater-magnet modules(HMM) for simultaneous generation of temperature and magnetic field have been developed. At the same time, as the temperature is controlled as usual, e.g. by DC, the characteristics of the magnetic field can be adjusted via frequency, phase shift of the alternating current (AC) and by changing the amplitude via the AC/DC ratio. Global modelling and dummy measurements were used to optimize and validate the HMM configuration and process parameters. GaAs and Ge single crystals with improved parameters were grown in HMM-equipped industrial liquid encapsulated Czochralski (LEC) puller and commercial vertical gradient freeze (VGF) furnace, respectively. The vapour pressure controlled Czochralski (VCz) variant without boric oxide encapsulation was used to study the movement of floating particles by the TMF-driven vortices.

전류에 의한 철단결정의 교류 자기감수율 : 전류 변화에 의한 효과 (AC susceptibility of current-carrying iron whiskers : Effect of current variation)

  • Jae-Gwang Lee
    • 한국자기학회지
    • /
    • 제5권3호
    • /
    • pp.179-184
    • /
    • 1995
  • {100} 철단결정에 자기장을 가해주거나 혹은 자기장 없이 전류만을 변화 시킬 때의 교류 자기감수율에 관하여 연구 하였다. 작은 자기장과 전류를 철단결정에 걸어줄때, 단결정의 단연적 중앙끈처에는 정사각형 자구가 형성된다. 실험을 통하여 이 자구의 자기화 방향으로 자장을 걸어주변 걸어주는 전류크기와 전류방향의 영향을 받음을 보인다. 이 실험 결과는 전류에의해 중앙에 형성된 자구가 전류의 증감함에따라 변화하는 자구크기로 설명할 수 있다. 실험으로 측정된 자기강수율을 설명하기 위하여 미세 자기이론을 사용하였으며, energy 값을 구히기 위하여 간단한 model을 설정하였다. 이 model로부터 교류 자기감수율을 구할 수 있었으며, 이때 계산한 교류 자기감수율은 한 안정된 구조에서 다른 안정된 구조로 변화하는 전류를 제외한 거의 대부분 전류에 대하여 정량적으로 설명할 수 있었다.

  • PDF

Thermo-sensitive Electrospun Fibrous Magnetic Composite Sheets

  • Choi, Jungsu;Kim, Jinu;Yang, Heejae;Ko, Frank K.;Kim, Ki Hyeon
    • Journal of Magnetics
    • /
    • 제20권3호
    • /
    • pp.215-220
    • /
    • 2015
  • The PVDF fibrous composite filled with iron oxide nanoparticles were prepared by using the electrospinning technique. The electrospun composite have the thickness in the range of $60-80{\mu}m$ with the average fibrous diameters of 500-900 nm. The magnetizations of PVDF fibrous composite filled with iron oxide nanoparticles showed 4.5 emu/g, 3.1 emu/g and 1.6 emu/g at 1.5 T of external magnetic field for 20 wt.%, 10 wt.% and 5 wt.% iron oxide nanoparticles, respectively. The heat elevation of the magnetic composite were measured under various AC magnetic fields, frequency and the ambient temperatures. The temperature reached up to $46.3^{\circ}C$ from $36^{\circ}C$ at 128 Oe and 355 kHz for 20 wt.% iron oxide nanoparticles filled in PVDF fibrous composite sheet. The specific absorption rate of theses sheets increased from 0.041 W/g to 0.236 W/g with the increment of AC magnetic field from 90 Oe to 167 Oe at 190 kHz, respectively.

Test result of striated HTS compact cables for low AC loss

  • Kim, Y.;Kim, W.S.;Lee, J.K.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제15권2호
    • /
    • pp.44-47
    • /
    • 2013
  • Large AC loss from the second generation (2G) high temperature superconducting (HTS) wires has been one of the major bottlenecks in power applications with HTS materials. Moreover, the large power applications also require the large current capacity from the HTS wires, which makes them produce larger AC losses. In order to reduce the AC loss from the HTS conductors with large current capacity, an HTS compact cable with some striations on the superconducting layers has been proposed. In this paper, we prepared some sample HTS compact conductors with striations, and measured their magnetization loss from the external magnetic field. We also made some slits on the superconducting layer of the HTS wire by laser cutting to reduce the aspect ratio of the superconducting layers. It would make the low eddy current loss and magnetic decoupling. Finally, the magnetization losses of the sample HTS compact conductors were measured and analyzed.

Experimental and numerical approaches for AC loss estimation in high $T_{c}$ superconductors

  • Amemiya, Naoyuki
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제6권2호
    • /
    • pp.1-6
    • /
    • 2004
  • It is important to estimate the total AC loss which is the total energy, or power, dissipated in the superconductor in the simultaneous application of AC transport current and an AC external magnetic field. Experimental and numerical works on AC loss estimation of high $T_c$ superconductors in the author's group are reviewed. The method and the set-up for total AC loss measurements are described. The experimental results for a twisted Bi-2223 multifilamentary tape and a Y-123 mm conductor are given. A general theory for numerical electromagnetic field analysis of superconductor by the finite element method is explained. The numerical results for twisted Bi-2223 multifilamentary tapes and a rectangular superconductor simulating coated conductors are presented.

RELATIONSHIP BETWEEN STATIC AND DYNAMIC MAGNETORESISTANCE BEHAVIOR OF METALLIC ARTIFICIAL SUPERLATTICES

  • Song, Yong-Jin;Joo, Seung-Ki
    • 한국자기학회지
    • /
    • 제5권5호
    • /
    • pp.567-569
    • /
    • 1995
  • By using the ac field source which can change the applied field magnitude, frequency and dc offset field, the dynamic magnetoresistance characteristics of permalloy based multilayers which have different R-H(resistance-magnetic field) curves were monitored and compared with static magnetoresistance curves that were measured with electromagnet of VSM. Output of each sample according to the external field strength was identified and optimum bias position could be obtained.

  • PDF

미소 교류 자기장 측정을 위한 Mach-Zehnder 광섬유 간섭계 자기센서 특성분석 (Fiber-optic Mach-Zehnder Interferometer for the Detection of Small AC Magnetic Field)

  • 김대연;안준태;공홍진;김병윤
    • 한국광학회지
    • /
    • 제2권3호
    • /
    • pp.139-148
    • /
    • 1991
  • 광섬유를 사용하여 미소 교류자기장 (200Hz-2kHz) 감지를 위한 광섬유 간섭계 자기센서시스템을 구성하였다. 자왜효과(magnetostriction effect)가 큰 비정질 metallic glass(2605SC)를 광섬유에 부착하여 자기장 감지부를 제작하고 방향성 결합기 metallic glass(2605SC)를 광섬유에 부착하여 자기장 감지부를 제작하고 방향성 결합기(directional coupler)를 사용한 광섬유 일체식(all-fiber type)으로 Mach-Zehnder 간섭계를 구성하여 외부 자기장의 변화를 간섭계의 위상변화로 변환시켜 그 크기를 측정하였다. 온도변화, 진동 등 주위환경에서 오는 불규칙한 신호에 의한 간섭계의 신호소멸(signal fading) 문제는 능동 위상추적방법(active phase tracking method)으로 간섭계의 기준 광통로(reference arm)에 위치한 위상 변조기에 보상신호를 되먹임으로써, 직각조건(quadrature condition)을 이루어 안정시켰다. 측정 결과 metallic glass의 주파수 반응특성은 900Hz-2kHz 대역에서 거의 비슷한 경향을 보였으며 최대 감도를 나타내는 직류 바이어스 자기장은 3.5 Oe 였다. 미소 교류자기장에 대한 간섭계의 출력은 $\pm$0.5 Oe 범위 안에서 좋은 선형성을 보였다. 1 kHz 교류자기장에 대한 scale factor S는 8.0 rad/Oe 이었으며 최소감지자기장은 $3X10^{-6} Oe/\sqrt{Hz}$(1Hz detection bandwidth)이었다.

  • PDF

교류용 초전도선의 결합손실해석 (Numerical Analysis of The Coupling Loss in AC Superconducting Wires)

  • 심정욱;차귀수;이지광;최경달;한송엽
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 A
    • /
    • pp.291-293
    • /
    • 1997
  • The external magnetic field which is applied to the superconducting wire generates coupling loss. Analytical method has been used for the calculation of the coupling loss. This paper calculates the coupling loss that is generated in the matrix by the external magnetic field. Two-dimensional Finite Element Method has been used for the calculation.

  • PDF

고온초전도선재의 교류손실 해석 및 실험 (AC loss analysis and experimental evaluation of a high temperature superconductor)

  • 류경우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.96-100
    • /
    • 2001
  • Bi-2223 tapes have been developed for low-field power applications at liquid nitrogen temperature. When the Bi-2223 tapes are used in an application such as a power transmission cable or a power transformer, they are supplied with an AC transport current and exposed to an external magnetic field generated by neighboring tape's AC currents simultaneously. AC loss taking into account such real applications is a crucial issue for power applications of the Bi-2223 tapes to be feasible. In this paper, the transport losses for different AC current levels and arrangements of the neighboring tapes have been measured in a 1.5 m long Bi-2223 tape. The significant increase of the transport losses due to neighboring tape's AC currents is observed. An increase of the transport losses caused by a decrease of the Bi-2223 tape's critical current is a minor effect. The measured transport losses could not be explained by a dynamic resistance loss based on DC voltage-current characteristics in combination with the neighboring tape's AC currents. The transport losses do not depend on the frequency of the neighboring tape's AC currents but its arrangements in the range of small current especially.

  • PDF

외부자장인가 방향에 따른 YBCO CC의 자화 손실 특성 (Magnetization Losses in YBCO Coated Conductors According to Angles of External Magnet Field)

  • 임형우;이상수;이희준;차귀수;이지광
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1222-1224
    • /
    • 2005
  • AC loss is an important factor in the development of superconducting tapes and superconducting power applications. In this paper, magnetization loss in YBCO coated conductor have been measured and compared with Brandt equation. Measurements of magnetization loss were performed under various angles of external magnetic field to consider the anisotropic characteristics of YBCO coated conductors. The results show that measured values of magnetization loss agreed well with the calculated value by using Brandt equation, especially at large degrees of incidence angle. The magnetization losses were strongly influenced by the direction of external magnet field as were expected.

  • PDF