• 제목/요약/키워드: External Element

검색결과 1,018건 처리시간 0.025초

Buckling behaviours of functionally graded polymeric thin-walled hemispherical shells

  • Uysal, Mine U.
    • Steel and Composite Structures
    • /
    • 제21권4호
    • /
    • pp.849-862
    • /
    • 2016
  • This paper investigates the static buckling behaviours of Functionally Gradient Polymeric Material (FGPM) shells in the form of hemispherical segment. A new FGPM model based on experimental was considered to investigate the buckling problem of thin-walled spherical shells loaded by the external pressure. The spherical shells were formed by FGPM which was produced adding the two types of graphite powders into epoxy resin. The graphite powders were added to the epoxy resin as volume of 3, 6, 9, and 12%. Halpin-Tsai and Paul models were used to determine the elastic moduli of the parts of FGPM. The detailed static buckling analyses were performed by using finite element method. The influences of the types and volume of graphite powders on the buckling behaviour of the FGPM structures were investigated. The buckling loads of hemispherical FGPM shells based on Halpin-Tsai and Paul models were compared with those determined from the analytical solution of non-graphite condition existing for homogeneous material model. The comparisons between these material models showed that Paul model was overestimated. Besides, the critical buckling loads were predicted. The higher critical buckling loads were estimated for the PV60/65 graphite powder due to the compatible of the PV60/65 graphite powder with resin.

Probabilistic structural damage detection approaches based on structural dynamic response moments

  • Lei, Ying;Yang, Ning;Xia, Dandan
    • Smart Structures and Systems
    • /
    • 제20권2호
    • /
    • pp.207-217
    • /
    • 2017
  • Because of the inevitable uncertainties such as structural parameters, external excitations and measurement noises, the effects of uncertainties should be taken into consideration in structural damage detection. In this paper, two probabilistic structural damage detection approaches are proposed to account for the underlying uncertainties in structural parameters and external excitation. The first approach adopts the statistical moment-based structural damage detection (SMBDD) algorithm together with the sensitivity analysis of the damage vector to the uncertain parameters. The approach takes the advantage of the strength SMBDD, so it is robust to measurement noise. However, it requests the number of measured responses is not less than that of unknown structural parameters. To reduce the number of measurements requested by the SMBDD algorithm, another probabilistic structural damage detection approach is proposed. It is based on the integration of structural damage detection using temporal moments in each time segment of measured response time history with the sensitivity analysis of the damage vector to the uncertain parameters. In both approaches, probability distribution of damage vector is estimated from those of uncertain parameters based on stochastic finite element model updating and probabilistic propagation. By comparing the two probability distribution characteristics for the undamaged and damaged models, probability of damage existence and damage extent at structural element level can be detected. Some numerical examples are used to demonstrate the performances of the two proposed approaches, respectively.

비자성체 이중관의 원격장 에너지 전달 경로 (Remote Field Energy Flow Path at Nonmagnetic Coaxial Tubes)

  • 이재경
    • 비파괴검사학회지
    • /
    • 제21권5호
    • /
    • pp.526-531
    • /
    • 2001
  • 공통축 형태로 배치된 비자성체 이중관에 있어서 유한요소해석 상용 소프트웨어와 실험적인 방법을 각각 이용하여 원격장 와전류 에너지의 전달 경로를 연구하였다. 연구결과 이중관에 있어서 원격장 와전류 에너지는 두 관 사이의 공간을 따라 흐르는 것이 아니라, 단일 튜브의 경우와 마찬가지로 외측 튜브의 외면을 따라 흐름을 확인하였다. 이는 원격장 와전류 효과의 관벽투과 특성이 이중관에 있어서도 유효함을 보여주는 것이다. 따라서, 중수로형 핵연료 채널과 같은 이중관 형태를 대상으로 내관 및 외관의 내 외부 결함 탐상, gap 분포 및 지지대의 위치 확인 등에 원격장 와전류 방법의 관벽투과 특성이 응용될 수 있음을 보였다.

  • PDF

단면감소를 고려한 파이프의 좌굴에 관한 연구 (Buckling Analysis of Pipelines with Reduced Cross Section)

  • 최동호;고영찬;권순길;이종선
    • 대한토목학회논문집
    • /
    • 제33권3호
    • /
    • pp.865-873
    • /
    • 2013
  • 본 연구에서는 부식이나 보강재가 고려된 비균일한 두께를 가지는 파이프라인에 대하여 일정한 외압을 받을 때의 탄성 좌굴하중을 이론적으로 산정하였다. 길이가 매우 긴 원통형 쉘 구조물인 파이프라인을 단순한 링 구조물로 가정하였고, 고유함수를 유도하여 좌굴 임계하중을 산정하였다. 또한, 두께 변화와 두께가 감소된 구간의 범위에 따른 변수해석을 수행하였다. 이론식에 의해 산정된 좌굴 임계하중 결과를 유한요소해석 결과와 비교하여 검증하였고, 두 결과는 잘 일치함을 알 수 있었다.

가스터빈 차폐막의 소음 저감효과에 관한 연구 (The Noise Reduction Effect by the Enclosure of Gas Turbines)

  • 박대훈;신유인;박성규;김강일;송철기
    • 한국정밀공학회지
    • /
    • 제34권4호
    • /
    • pp.287-292
    • /
    • 2017
  • A gas turbine is the main equipment used in a combined heat and power plant. It generates a high sound pressure noise level. To reduce the noise level, an enclosure is installed around the turbine. The sound insulation performance of the enclosure affects the amount of external noise reduction. In this study, a sound transmission loss analysis is performed using the boundary element method to predict sound insulation performance according to the numbers and shapes of the supporter. Radiated noise analysis is also performed for the main external points of the enclosure using ray-acoustics. The results of these analyses are presented and a design plan is proposed that reduces the sound pressure noise level of the enclosure.

상수도용 도복장강관의 용접 및 외부하중에 의한 응력 특성에 관한 연구(I) - 후열처리에 의한 용접부의 잔류응력 특성 - (A Study on the Stress Distribution of Steel Water Pipes(I) - Characteristics of Residual Stress Distribution by PWHT -)

  • 윤석환;이승기;나석주;고명환
    • Journal of Welding and Joining
    • /
    • 제19권3호
    • /
    • pp.285-291
    • /
    • 2001
  • Large steel water pipes are joined prevalently by the bell end method, and are welded both at inside and outside of lapped parts. In practice, welded joints of water pipes are very critical, because in most cases failure of pipes causing leakage occurs at the welded joint. Therefore some methods have been developed to ensure the soundness of welded joints of water pipes, like leakage tests and nondestructive tests (NDTs). But one of the major characteristics that affects the soundness of welded Joints is the stress distribution caused by welding and external forces. Some studies have been carried out on the residual stress of steel water popes, but complex stress distributions by welding and external forces are rarely studied. In this study, temperature and stress distributions in steel water pipes produced by welding are predicted by a three-dimensional finite element method(FEM). Also, stress values are measured from real steel water pipes by the hole-drilling methods, and compared with predicted ones. The influence of some typical post weld treatments on residual stress distribution was also investigated by residual stress measurements.

  • PDF

블록식 보강토 옹벽 설계프로그램 개발 (Development of Design Program for Block-type Reinforced Earth Retaining Wall)

  • 이충원;유지훈;민연식;장동수;임현택;문용배;김승태;김용성
    • 한국농공학회논문집
    • /
    • 제56권6호
    • /
    • pp.75-84
    • /
    • 2014
  • This study aims to develop the program for design of a reinforced earth retaining wall. For this purpose, the external stability such as overturning, sliding and bearing capacity and the internal stability such as pull-out failure and tensile rupture of the reinforced earth retaining wall with the reinforcement spacing and the backfill inclination were examined. In addition, the calculated results from the developed program were verified by comparing with the simulated results based on the three-dimensional finite element analysis. It is expected that this program contributes to effective design of the reinforced earth retaining wall.

슬림형 광 디스크 드라이브의 방진설계 (An Anti-vibration Design of Slim-type Optical Disk Drive)

  • 김남웅;김국원;홍구;정문채;김외열
    • 소음진동
    • /
    • 제9권2호
    • /
    • pp.324-330
    • /
    • 1999
  • With the increase of track density, high rotational speed and the compatibility for various media such as CD-ROM, CD-R/RW, DVD-ROM/RAM/RW etc. in optical disk drive, the effective anti-vibration design is so crucial for robust operaton. Especailly when the drive is self-excited by unbalanced disk, internal sled base vibration and its external transmission to the case bring about so severe problem. Generally these two consideration points the practical anti-vibration design process to control thses two conflictive properties using finite element analysis. As an example of the design process, Duro 25 and 40 visco-elastic rubber mount was selected and analyzed. The stiffness obtained from FEM rubber model was well matched with the experiments. Also it was confirmed that the internal and external vibration induced from unbalanced disk have good agreement with experimental results. The proposed design process is adopted to the slim-type optical disk drive.

  • PDF

Modeling fire performance of externally prestressed steel-concrete composite beams

  • Zhou, Huanting;Li, Shaoyuan;Zhang, Chao;Naser, M.Z.
    • Steel and Composite Structures
    • /
    • 제41권5호
    • /
    • pp.625-636
    • /
    • 2021
  • This paper examines the fire performance of uninsulated and uncoated restrained steel-concrete composite beams supplemented with externally prestressed strands through advanced numerical simulation. In this work, a sequentially coupled thermo-mechanical analysis is carried out using ABAQUS. This analysis utilizes a highly nonlinear three-dimensional finite element (FE) model that is specifically developed and validated using full-sized specimens tested in a companion fire testing program. The developed FE model accounts for nonlinearities arising from geometric features and material properties, as well as complexities resulting from prestressing systems, fire conditions, and mechanical loadings. Four factors are of interest to this work including effect of restraints (axial vs. rotational), degree of stiffness of restraints, the configuration of external prestressed tendons, and magnitude of applied loading. The outcome of this analysis demonstrates how the prestressing force in the external tendons is primarily governed by the magnitude of applied loading and experienced temperature level. Interestingly, these results also show that the stiffness of axial restraints has a minor influence on the failure of restrained and prestressed steel-concrete composite beams. When the axial restraint ratio does not exceed 0.5, the critical deflection of the composite beam is lower than that of the composite beam with a restraint ratio of 1.0.

Strengthening of T-beams using external steel clamps and anchored steel plates

  • Yunus Dere;Yasin Onuralp Ozkilic;Ali Serdar Ecemis;Hasan Husnu Korkmaz
    • Steel and Composite Structures
    • /
    • 제48권4호
    • /
    • pp.405-417
    • /
    • 2023
  • In order to strengthen the reinforced concrete T-beams having insufficient shear strength, several strengthening techniques are available in the literature. In this study, three different strengthening strategies were numerically studied. First one is affixing steel plates to the beam surfaces. Second one includes tightening external steel bars vertically similar to beam stirrups. The last one is simultaneous application of these two strengthening procedures which is particularly proposed in this work. Available experimental test series in the literature were handled in the study. Finite element (FE) models of reinforced concrete beam specimens having sufficient (Beam-1) and low shear capacity (Beam-2) were created within ABAQUS environment. Strengthened beams with different techniques were also modelled to reflect improved shear capacity. FE simulations made it possible to investigate parameters that were not examined during the previous experimental studies. The results of the analyses were then compared and found consistent with the experimentally obtained data. Experimental and FEM analysis results are in agreement between 1% (closest) and 6%. (maximum). Beam-2 was stregthened with 5 new porposed methods. The rate of increase in shear strength varies between 33% and 64%. It was found that, the strengthening techniques were fairly useful in improving the shear capacity of the considered girder. The model with the proposed strengthening alternative has accomplished a higher load carrying capacity, ductility and stiffness than all of the other models.